The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Inflatable Penile Implant Infection: Predisposing Factors and Treatment Suggestions
Abstract
A retrospective review of 1,337 consecutive inflatable prosthesis implantations was done to detect predisposing factors for infection. Operations were performed by the same team during a 7-year period. Of the procedures 823 were primary implantations, while the remaining 514 were either revisions (mechanical failure, iatrogenic causes or patient dissatisfaction), salvage operations or removals for infection. The etiology of impotence as a predisposition for infection in primary implantations was significant for spinal cord injury (9% of the cases) and steroid use (50%). Diabetes had a statistically insignificant 3% risk of infection, with all other causes having a 1% infection rate. A total of 428 revisions was performed with an overall infection rate of 10%. Rates of infection ranged from 8% in nondiabetics to 18% in diabetics requiring revision. Staphylococcus species were the most commonly cultured organisms. Salvage operations (29 cases) of several types were attempted for infected prostheses. Our results with salvage were poor and we currently routinely remove the entire prosthesis for infection except in cases of urethral erosion of 1 cylinder.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adherence of slime-producing strains of Staphylococcus epidermidis to smooth surfaces
Christensen, G. D., Simpson, W. A., Bisno, A. L., & Beachey, E. H. (1982) · Infection and Immunity · doi:10.1128/iai.37.1.318-326.1982 · Cited by 1,410
Bacterial Biofilm in Persistent Penile Prosthesis-Associated Infection
Nickel, J. C., Heaton, J. P. W., Morales, Á., et al. (1986) · The Journal of Urology · doi:10.1016/s0022-5347(17)45747-8 · Cited by 101
Late Hematogenous Infection of Penile Prostheses
Carson, C. C., & Robertson, C. N. (1988) · The Journal of Urology · doi:10.1016/s0022-5347(17)42287-7 · Cited by 90
Rossier, A. B., & Fam, B. A. (1984) · The Journal of Urology · doi:10.1016/s0022-5347(17)50201-3 · Cited by 65
Risk Factors Associated with Penile Prosthesi Infection
Radomski, S. B., & Herschorn, S. (1992) · The Journal of Urology · doi:10.1016/s0022-5347(17)37243-9 · Cited by 61
Experience with Penile Prosthesis in Spinal Cord Injury Patients
Golji, H. (1979) · The Journal of Urology · doi:10.1016/s0022-5347(17)56756-7 · Cited by 50
Cited by
Tong, S. Y. C., Davis, J. S., Eichenberger, E., Holland, T. L., & Fowler, V. G. (2015) · Clinical Microbiology Reviews · doi:10.1128/cmr.00134-14 · Cited by 5,192
Treatment of Infections Associated with Surgical Implants
Darouiche, R. O. (2004) · New England Journal of Medicine · doi:10.1056/nejmra035415 · Cited by 2,257
Levine, L. A., Becher, E., Bella, A., Brant, W., Kohler, T., Martinez-Salamanca, J. I., Trost, L., & Morey, A. (2016) · The Journal of Sexual Medicine · doi:10.1016/j.jsxm.2016.01.017 · Cited by 318
Mulhall, J., Anderson, M., & Parker, M. (2005) · The Journal of Sexual Medicine · doi:10.1111/j.1743-6109.2005.20113.x · Cited by 135
Metadata
- Authors
- Wilson, S. K., & Delk, J. R.
- Venue
- Journal of Urology
- Published
- 1995-03
- Volume
- 153
- Issue
- 3
- Pages
- 659-661
- ISSN
- 0022-5347 (ISSN-L)
- 1527-3792
- OpenAlex
- W2084173045
- Cited by
- 262
- References
- 6
- FWCI
- 3.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Inflatable Penile Implant Infection: Predisposing Factors and Treatment Suggestions. https://app.cochat.ai/papers/10.1016/s0022-5347(01)67678-x
- The paper
- Wilson, S. K., & Delk, J. R. (1995). Inflatable Penile Implant Infection: Predisposing Factors and Treatment Suggestions. Journal of Urology. https://doi.org/10.1016/s0022-5347(01)67678-x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.