Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 266

The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.

Efficacy and Safety of Sacral Nerve Stimulation for Urinary Urge Incontinence: A Systematic Review

Brazzelli, Miriam, Murray, Alison, Fraser, Cynthia·2006·Journal of Urology

Abstract

PURPOSE: We systematically reviewed the evidence on the efficacy and safety of sacral nerve stimulation (SNS) for severe urge incontinence. MATERIALS AND METHODS: A systematic review was performed of primary studies of SNS for urge incontinence published in English between 1966 and May 2003, and identified in major electronic databases. Two reviewers independently selected studies, assessed their methodological quality and extracted data. RESULTS: Four randomized controlled trials and 30 case series were identified. Evidence from the randomized controlled trials, involving approximately 120 patients, showed that about 80% achieved continence or greater than 50% improvement in their main incontinence symptoms after SNS compared with about 3% of controls receiving conservative treatments while waiting for an implant. While case series were larger, they were methodologically less reliable. However, they showed similar results with 67% of patients becoming dry or achieving a greater than 50% improvement in symptoms after implantation. Incontinence episodes, leakage severity, voiding frequency and pad use were significantly lower after implantation. Benefits were reported to persist 3 to 5 years after implantation. Adverse events were documented in 27 studies. Overall the reoperation rate in implanted cases was 33%. The most common reason for surgical revision was relocation of the generator because of pain and infection. Common complications were pain at the implant or lead site in 25% of patients, lead related problems such as lead migration in 16%, replacement and repositioning of the implanted pulse generator in 15%, wound problems in 7%, adverse effects on bowel function in 6%, infection in 5% and generator problems in 5%. Permanent removal of the electrodes was reported in 9% of patients. Technical changes with time have been associated with decreased complication rates. CONCLUSIONS: There is evidence indicating that SNS is effective for decreasing symptoms in patients with urge incontinence. Adverse events occurred in about half of the implanted cases and surgical revision was performed in 33%. No major irreversible complications were reported in the studies reviewed. Further research is required on the long-term effects of and quality of life in patients with SNS.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0022-5347(05)00326-5

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 18 references

Cited by

See all 266

Metadata

Authors
Brazzelli, M., Murray, A., & Fraser, C.
Venue
Journal of Urology
Published
2006-03
Volume
175
Issue
3
Pages
835-841
ISSN
  • 0022-5347 (ISSN-L)
  • 1527-3792
OpenAlex
W2064471798
Cited by
266
References
18
FWCI
1.48
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Efficacy and Safety of Sacral Nerve Stimulation for Urinary Urge Incontinence: A Systematic Review. https://app.cochat.ai/papers/10.1016/s0022-5347(05)00326-5
The paper
Brazzelli, M., Murray, A., & Fraser, C. (2006). Efficacy and Safety of Sacral Nerve Stimulation for Urinary Urge Incontinence: A Systematic Review. Journal of Urology. https://doi.org/10.1016/s0022-5347(05)00326-5

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.