The DOI matches its Crossref record.
COMPARATIVE ASSESSMENT OF PEDIATRIC TESTICULAR VOLUME: ORCHIDOMETER VERSUS ULTRASOUND
Abstract
PURPOSE: Testicular volume measurements obtained with the Prader and Rochester orchidometers were compared to those obtained using scrotal ultrasound. The ability of each orchidometer versus ultrasound in detecting volume differential between 2 testes and the accuracy of orchidometer measurement by a less experienced examiner to that of a urologist were compared. MATERIALS AND METHODS: A total of 65 males were examined by the attending urologist and urology nurse using the Prader and Rochester orchidometers, and scrotal ultrasound was subsequently performed by an attending radiologist. Statistical analysis of the results was performed to determine the correlation of orchidometer measurements between examiners, as well as with ultrasound, and sensitivity and specificity of orchidometer and ultrasound in detecting defined volume differentials between testes of 10%, 15%, 20% and 25%. RESULTS: There was a strong linear relationship between testicular volume measurements using either orchidometer and ultrasound. To detect a defined volume differential as determined by ultrasound orchidometer sensitivity was weak, whereas orchidometer specificity was better. There was a strong correlation between orchidometer measurements of the urology nurse and attending urologist. CONCLUSIONS: Although the orchidometer remains valuable in assessing size of the individual testis, it is too insensitive to volume differentials relative to ultrasound to be used routinely to determine growth impairment. For this reason observation of an adolescent with varicocele should include an annual ultrasound assessment of testicular volume.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Dorn, L. D., Dahl, R. E., Woodward, H. R., & Biro, F. (2006) · Applied Developmental Science · doi:10.1207/s1532480xads1001_3 · Cited by 477
Clinical Management of Congenital Hypogonadotropic Hypogonadism
Young, J., Xu, C., Papadakis, G. E., Acierno, J. S., Maione, L., Hietamäki, J., Raivio, T., & Pitteloud, N. (2019) · Endocrine Reviews · doi:10.1210/er.2018-00116 · Cited by 396
Ultrasound of the male genital tract in relation to male reproductive health
Lotti, F., & Maggi, M. (2015) · Human Reproduction Update · doi:10.1093/humupd/dmu042 · Cited by 365
Testicular Volume Measurement: Comparison of Ultrasonography, Orchidometry, and Water Displacement
Sakamoto, H., Saito, K., Oohta, M., Inoue, K., Ogawa, Y., & Yoshida, H. (2007) · Urology · doi:10.1016/j.urology.2006.09.012 · Cited by 257
Gonad evaluation in male systemic lupus erythematosus
Soares, P. M. F., Borba, E. F., Bonfa, E., Hallak, J., Corrêa, A. L., & Silva, C. A. A. (2007) · Arthritis & Rheumatism · doi:10.1002/art.22660 · Cited by 130
Metadata
- Authors
- DIAMOND, D. A., PALTIEL, H. J., DiCANZIO, J., ZURAKOWSKI, D., BAUER, S. B., ATALA, A., EPHRAIM, P. L., GRANT, R., & RETIK, A. B.
- Venue
- Journal of Urology
- Published
- 2000-09
- Volume
- 164
- Issue
- 3 Part 2
- Pages
- 1111-1114
- ISSN
- 0022-5347 (ISSN-L)
- 1527-3792
- OpenAlex
- W2039616440
- Cited by
- 218
- References
- 0
- FWCI
- 5.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: COMPARATIVE ASSESSMENT OF PEDIATRIC TESTICULAR VOLUME: ORCHIDOMETER VERSUS ULTRASOUND. https://app.cochat.ai/papers/10.1016/s0022-5347(05)67264-3
- The paper
- DIAMOND, D. A., PALTIEL, H. J., DiCANZIO, J., ZURAKOWSKI, D., BAUER, S. B., ATALA, A., EPHRAIM, P. L., GRANT, R., & RETIK, A. B. (2000). COMPARATIVE ASSESSMENT OF PEDIATRIC TESTICULAR VOLUME: ORCHIDOMETER VERSUS ULTRASOUND. Journal of Urology. https://doi.org/10.1016/s0022-5347(05)67264-3
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.