Endometrial thickness as a test for endometrial cancer in women with postmenopausal vaginal bleeding
The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To assess the value of endometrial thickness measurement as a test for endometrial cancer in postmenopausal women with vaginal bleeding (symptomatic women). DATA SOURCES: We conducted a literature search using the MEDLINE database from 1991 to 1997, and the key words "vaginal ultrasonography" and "endometrial thickness measurement." The review was limited to original research reports written in English, concerning symptomatic women having vaginal ultrasonography before a diagnostic test and not receiving tamoxifen. STUDY SELECTION: A total of 48 studies were identified. A questionnaire was sent to the corresponding author of each paper requesting supplementary information. Data were included in our analysis if the corresponding author was able to supply information on the median endometrial thickness in unaffected symptomatic women and the endometrial thickness values in affected women. Nine studies were thus included in our meta-analysis, representing 3483 women without endometrial cancer and 330 women with endometrial cancer. TABULATION, INTEGRATION, AND RESULTS: The median endometrial thickness in women with endometrial cancer was 3.7 times that in unaffected women at the same center, and with the same menopausal status and same hormone replacement therapy use category. The detection rate was 63% (95% confidence interval 58, 69) for a 10% false-positive rate, or 96% (95% confidence interval 94, 98) for a 50% false-positive rate. CONCLUSION: Endometrial thickness measurement in symptomatic women does not reduce the need for invasive diagnostic testing because 4% of the endometrial cancers would still be missed with a false-positive rate as high as 50%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Endovaginal Ultrasound to Exclude Endometrial Cancer and Other Endometrial Abnormalities
Smith-Bindman, R., Kerlikowske, K., Feldstein, V. A., Subak, L., Scheidler, J., Segal, M., Brand, R., & Grady, D. (1998) · JAMA · doi:10.1001/jama.280.17.1510 · Cited by 736
Karlsson, B., Granberg, S., Wikland, M., Ylöstalo, P., Torvid, K., Marsal, K., & Valentin, L. (1995) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(95)90483-2 · Cited by 564
Relative frequency of primary ovarian neoplasms: A 10‐year review
Koonings, P. P., Campbell, K., Mishell, D. R., & Grimes, D. A. (1990) · International Journal of Gynecology & Obstetrics · doi:10.1016/0020-7292(90)90378-x · Cited by 412
Granberg, S., Wikland, M., Karlsson, B., Norström, A., & Friberg, L.-G. (1991) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(91)90622-x · Cited by 352
Goldstein, S. R., Nachtigall, M., Snyder, J. R., & Nachtigall, L. (1990) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(11)90683-8 · Cited by 291
Vaginosonography for early detection of endometrial carcinoma?
Osmers, R., Volksen, M., & Schauer, A. (1990) · The Lancet · doi:10.1016/0140-6736(90)91387-p · Cited by 205
Pipelle endometrial sampling in patients with known endometrial carcinoma.
Stovall, T., Photopulos, G. J., Poston, W., Ling, F., & Sandles, L. (1991) · PubMed · Cited by 195
Ferrazzi, E., Torri, V., Trio, D., Zannoni, E., Filiberto, S., & Dordoni, D. (1996) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.1469-0705.1996.07050315.x · Cited by 194
The Accuracy of Transvaginal Ultrasonography in the Diagnosis of Endometrial Abnormalities
Dijkhuizen, F. (1996) · Obstetrics & Gynecology · doi:10.1016/0029-7844(95)00450-5 · Cited by 194
Transvaginal sonography of the endometrium in postmenopausal women.
Varner, R. E., Sparks, J. M., Cameron, C., Roberts, L. L., & Soong, S.-J. (1991) · PubMed · Cited by 178
Cited by
Timmermans, A., Opmeer, B. C., Khan, K. S., Bachmann, L. M., Epstein, E., Clark, T. J., Gupta, J. K., Bakour, S. H., van den Bosch, T., van Doorn, H. C., et al. (2010) · Obstetrics & Gynecology · doi:10.1097/aog.0b013e3181e3e7e8 · Cited by 312
Smith‐Bindman, R., Weiss, E., & Feldstein, V. (2004) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.1704 · Cited by 276
(2018) · Obstetrics & Gynecology · doi:10.1097/aog.0000000000002631 · Cited by 264
Diagnostic strategies for postmenopausal bleeding.
Breijer, M. C., Timmermans, A., van Doorn, H. C., Mol, B. W. J., & Opmeer, B. C. (2010) · Obstetrics and Gynecology International · doi:10.1155/2010/850812 · Cited by 82
Metadata
- Authors
- Tabor, A.
- Venue
- Obstetrics & Gynecology
- Published
- 2002-04
- Volume
- 99
- Issue
- 4
- Pages
- 663-670
- ISSN
- 0029-7844 (ISSN-L)
- OpenAlex
- W2148282003
- Cited by
- 183
- References
- 32
- FWCI
- 10.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.