Fasting plasma glucose test at the first prenatal visit as a screen for gestational diabetes
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To determine whether the fasting plasma glucose test administered at the first prenatal visit could serve as an efficient screen for gestational diabetes. METHODS: A total of 5557 women not known to have diabetes were offered a fasting plasma glucose test at their first prenatal visit. Results less than 100 mg/dL were blinded. A glucose tolerance test was requested immediately of those whose screening test result was 100-125 mg/dL and of all women not identified as having diabetes by their 23rd gestational week. RESULTS: A total of 4507 women (81%) complied with the protocol. Of the 302 women found to have gestational diabetes, 46 (15%) were detected before 24 weeks. A false-positive rate of 57% was found at a threshold fasting glucose concentration giving a sensitivity of 80% for the detection of gestational diabetes. CONCLUSION: The fasting plasma glucose screening test at the first prenatal visit has good patient compliance. However, its poor specificity (high false-positive rate) makes it an inefficient screening test for gestational diabetes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Screening criteria for high-risk gestational diabetic patients
O'Sullivan, J. B., Mahan, C. M., Charles, D., & Dandrow, R. V. (1973) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(16)33833-9 · Cited by 478 · cited 2×
“Although no convention has been established regarding appropriate sensitivity and specificity for a screening test for gestational diabetes, the original study which proposed the use of the 50-g, 1-hour glucose screening test selected a threshold glucose concentration that gave a sensitivity of 79% and a false-positiv…”
BackgroundToward universal criteria for gestational diabetes: the 75-gram glucose tolerance test in pregnancy
Sacks, D. A., Greenspoon, J. S., Abu-Fadil, S., Henry, H. M., Wolde-Tsadik, G., & Yao, J. F. F. (1995) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(95)90580-4 · Cited by 210 · cited 4×
“Another important distinction between the design of the current study and that of prior reports is that we administered the fasting plasma glucose screening test independent of the administration of the GTT.”
MethodInfluentialSelf-citationMills, J. L., Jovanovic, L., Knopp, R., Aarons, J., Conley, M., Park, E., Lee, Y. J., Holmes, L., Simpson, J. L., & Metzger, B. (1998) · Metabolism · doi:10.1016/s0026-0495(98)90290-6 · Cited by 199
Cited by
Rich-Edwards, J. W., Fraser, A., Lawlor, D. A., & Catov, J. M. (2014) · Epidemiologic Reviews · doi:10.1093/epirev/mxt006 · Cited by 417
Thompson, D., Berger, H., Feig, D., Gagnon, R., Kader, T., Keely, E., Kozak, S., Ryan, E., Sermer, M., & Vinokuroff, C. (2013) · Canadian Journal of Diabetes · doi:10.1016/j.jcjd.2013.01.044 · Cited by 377
Feig, D. S., Berger, H., Donovan, L., Godbout, A., Kader, T., Keely, E., & Sanghera, R. (2018) · Canadian Journal of Diabetes · doi:10.1016/j.jcjd.2017.10.038 · Cited by 344
Immanuel, J., & Simmons, D. (2017) · Current Diabetes Reports · doi:10.1007/s11892-017-0943-7 · Cited by 264
Hughes, R. C. E., Moore, M. P., Gullam, J. E., Mohamed, K., & Rowan, J. (2014) · Diabetes Care · doi:10.2337/dc14-1312 · Cited by 238
“the first trimester may have a normal later pregnancy OGTT (31,32).”
Background
Metadata
- Authors
- Sacks, D.
- Venue
- Obstetrics & Gynecology
- Published
- 2003-06
- Volume
- 101
- Issue
- 6
- Pages
- 1197-1203
- ISSN
- 0029-7844 (ISSN-L)
- OpenAlex
- W1965419100
- Cited by
- 79
- References
- 4
- FWCI
- 4.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fasting plasma glucose test at the first prenatal visit as a screen for gestational diabetes. https://app.cochat.ai/papers/10.1016/s0029-7844(03)00049-8
- The paper
- Sacks, D. (2003). Fasting plasma glucose test at the first prenatal visit as a screen for gestational diabetes. Obstetrics & Gynecology. https://doi.org/10.1016/s0029-7844(03)00049-8
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.