Transvaginal Ultrasound in the Prediction of Preterm Delivery: Singleton and Twin Gestations
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To compare, in singleton and twin pregnancies, the effectiveness of transvaginal ultrasound versus digital examination in predicting preterm delivery in women with suspected preterm labor. METHODS: Transvaginal ultrasound and pelvic examinations were performed on patients admitted with suspected preterm labor between 23 and 33 weeks' gestation. Ultrasound assessment of cervical length and the presence of funneling with fundal pressure were recorded for each patient, and the results were compared with dilatation and effacement as assessed by digital examination for the prediction of preterm delivery in the two groups (singletons and twins). RESULTS: One hundred sixty-two subjects were recruited (136 singletons and 26 twin pregnancies), with no significant demographic differences between the groups. Overall, 33% of the participants delivered preterm (27% of singletons, 62% of twins). Using receiver operating characteristics curves, the best cutoff points were 30 mm for endocervical length at ultrasound, 50% for effacement, and 1.5 cm for dilatation. Of these, the best predictor was endocervical length, which was a better predictor in singleton than in twin pregnancies. Of the potential predictors, including endocervical length, funneling, dilatation, and effacement, only endocervical length was an independent predictor of preterm delivery at less than 34 weeks' gestation for both singletons and twins by multiple logistic regression. When analyzed for delivery at less than 37 weeks' gestation, this relation held true for singletons but not twins. Endocervical length less than 30 mm had a sensitivity of 81% and 75%, specificity of 65% and 30%, positive predictive value of 46% and 63%, and negative predictive value of 90% and 43% for singleton and twin pregnancies, respectively, in predicting spontaneous birth at less than 37 weeks' gestation. CONCLUSION: Between 23 and 33 weeks' gestation, transvaginal ultrasound assessment of endocervical length is superior to funneling and digital examination in predicting preterm delivery in patients who present with suspected preterm labor, and is a better predictor in singletons than in twins.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
[The length of the cervix and the risk of spontaneous premature delivery].
Blondel, B. (1996) · PubMed · Cited by 1,378
Prediction of risk for preterm delivery by ultrasonographic measurement of cervical length
Andersen, H. F., Nugent, C. E., Wanty, S. D., & Hayashi, R. H. (1990) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(90)91084-p · Cited by 463
Gomez, R., Galasso, M., Romero, R., Mazor, M., Sorokin, Y., Gonçalves, L., & Treadwell, M. (1994) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(94)90014-0 · Cited by 278
Cervical Sonography in Preterm Labor
(1994) · Journal of Diagnostic Medical Sonography · doi:10.1177/875647939401000529 · Cited by 195
Sonek, J., Iams, J. D., Blumenfeld, M. L., Johnson, F. F., Landon, M., & Gabbe, S. G. (1990) · PubMed · Cited by 150
Early prediction of preterm delivery by transvaginal ultrasonography
Okitsu, O., Mimura, T., Nakayama, T., & Aono, T. (1992) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.1469-0705.1992.02060402.x · Cited by 147
(1994) · Journal of Diagnostic Medical Sonography · doi:10.1177/875647939401000133 · Cited by 139
How Many Patients Are Necessary to Assess Test Performance?
Arkin, C. F. (1990) · JAMA · doi:10.1001/jama.1990.03440020109043 · Cited by 133
Preterm birth: A puzzle worth solving
Morrison, J. (1991) · International Journal of Gynecology & Obstetrics · doi:10.1016/0020-7292(91)90384-h · Cited by 103
Timor‐Tritsch, I. E., Boozarjomehri, F., Masakowski, Y., Monteagudo, A., & Chao, C. R. (1996) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(96)70338-1 · Cited by 95
Ayers, J. W. T., DeGrood, R. M., Compton, A. A., Barclay, M., & Ansbacher, R. (1988) · PubMed · Cited by 88
The length of the uterine cervix and its significance
Zemlyn, S. (1981) · Journal of Clinical Ultrasound · doi:10.1002/jcu.1870090603 · Cited by 63
Cited by
McIntosh, J., Feltovich, H., Berghella, V., & Manuck, T. (2016) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2016.04.027 · Cited by 265
Conde-Agudelo, A., Romero, R., Hassan, S. S., & Yeo, L. (2010) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2010.02.064 · Cited by 256
Prediction and early detection of preterm labor
Iams, J. (2003) · Obstetrics & Gynecology · doi:10.1016/s0029-7844(02)02505-x · Cited by 241
Markers of risk for preterm delivery
Lockwood, C. J., & Kuczynski, E. (1999) · Journal of Perinatal Medicine · doi:10.1515/jpm.1999.001 · Cited by 216
“Crane et al noted that a cervical length of < 3 cm was a poorer predictor of PTD in symptomatic patients with twin gestations, achieving a sensitivity of 75 %, specificity of 30 %, and positive and negative predictive values of 63 % and 43 %, respectively [19].”
BackgroundAccuracy of cervical transvaginal sonography in predicting preterm birth: a systematic review
Honest, H., Bachmann, L. M., Coomarasamy, A., Gupta, J. K., Kleijnen, J., & Khan, K. S. (2003) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.202 · Cited by 206
Metadata
- Authors
- CRANE, J., VANDENHOF, M., ARMSON, B., & LISTON, R.
- Venue
- Obstetrics & Gynecology
- Published
- 1997-09
- Volume
- 90
- Issue
- 3
- Pages
- 357-363
- ISSN
- 0029-7844 (ISSN-L)
- OpenAlex
- W2006734404
- Cited by
- 168
- References
- 12
- FWCI
- 8.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.