The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Prediction and early detection of preterm labor
Abstract
Studies of cervical sonography, fetal fibronectin, and uterine contraction monitoring during pregnancy have improved our understanding of how preterm labor occurs, but their use in practice remains uncertain. This article reviews the use of these tests to improve the accuracy of diagnosis of preterm labor and to estimate the likelihood of preterm birth in women with historical risk factors. Because the clinical criteria for a diagnosis of preterm labor are inaccurate until labor is well established, over-diagnosis is common. A cervical length measurement of more than 30 mm or a negative fibronectin obtained from a patient with possible preterm labor can avoid over-diagnosis and unnecessary treatment. There is no role for routine use of either cervical sonography or fibronectin to screen pregnant women for preterm birth risk, but women thought to be at increased risk may be reassured by negative test results. Uterine contraction monitoring has low sensitivity for detecting women at risk of preterm birth. Current use of cervical length and fetal fibronectin in pregnancy is limited to situations where a negative result can avoid unnecessary interventions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The length of the cervix and the risk of spontaneous premature delivery
Iams, J. D., Goldenberg, R. L., Meis, P. J., Mercer, B. M., Moawad, A., Das, A., Thom, E., McNellis, D., Copper, R. L., Johnson, F., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199602293340904 · Cited by 1,894
Self-citationFrequency of uterine contractions and the risk of spontaneous preterm delivery
Iams, J. D., Newman, R. B., Thom, E. A., Goldenberg, R. L., Mueller-Heubach, E., Moawad, A., Sibai, B. M., Caritis, S. N., Miodovnik, M., Paul, R. H., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa002868 · Cited by 205
Self-citationLeitich, H., Brunbauer, M., Kaider, A., Egarter, C., & Husslein, P. (1999) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(99)70407-2 · Cited by 178
Cited by
Hendler, I., Goldenberg, R. L., Mercer, B. M., Iams, J. D., Meis, P. J., Moawad, A. H., MacPherson, C. A., Caritis, S. N., Miodovnik, M., Menard, K. M., et al. (2005) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2004.09.021 · Cited by 327
Self-citationFele-Žorž, G., Kavšek, G., Novak-Antolič, Ž., & Jager, F. (2008) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-008-0350-y · Cited by 255
Biochemical predictors of preterm labor: fetal fibronectin and salivary estriol
Ramsey, P. S., & Andrews, W. W. (2003) · Clinics in Perinatology · doi:10.1016/s0095-5108(03)00109-x · Cited by 44
Sprague, A. E., O’Brien, B., Newburn-Cook, C., Heaman, M., & Nimrod, C. (2008) · Journal of Obstetrics and Gynaecology Canada · doi:10.1016/s1701-2163(16)32800-6 · Cited by 24
Metadata
- Authors
- Iams, J.
- Venue
- Obstetrics & Gynecology
- Published
- 2003-02
- Volume
- 101
- Issue
- 2
- Pages
- 402-412
- ISSN
- 0029-7844 (ISSN-L)
- OpenAlex
- W1981713568
- Cited by
- 241
- References
- 3
- FWCI
- 10.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Prediction and early detection of preterm labor. https://app.cochat.ai/papers/10.1016/s0029-7844(02)02505-x
- The paper
- Iams, J. (2003). Prediction and early detection of preterm labor. Obstetrics & Gynecology. https://doi.org/10.1016/s0029-7844(02)02505-x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.