Evaluation of Threatened Preterm Delivery by Transvaginal Ultrasonographic Measurement of Cervical Length
The DOI matches its Crossref record.
Abstract
OBJECTIVE: To establish a nomogram for the length of the uterocervical canal and to determine whether this can be used to predict preterm delivery. METHODS: Cervical length was measured by transvaginal ultrasonography in 32 women (21 primigravid, 11 multigravid) with threatened preterm delivery, and in 177 normal singleton pregnancies between 18-37 weeks' gestation. Regression analysis was used to create the nomogram. Student t test was used to compare the groups. RESULTS: A linear relationship was found between cervical length and gestational age (r = -0.4, P < .001). Comparison of cervical length on admission in the patients with threatened preterm delivery showed that 11 preterm deliveries occurred in women who had a mean cervical length of 23.2 mm (range 17-29), whereas 21 term deliveries occurred in women with a mean cervical length of 31.7 mm (range 21-42). The difference was significant (P < .001). A cervical length of less than 20 mm on admission had a positive predictive value of 100%. These patients had preterm delivery despite tocolytic therapy during hospitalization. CONCLUSION: The risk of preterm delivery is high in women whose cervical length on admission is less than 30 mm, and strict management is required for those with a cervical length of less than 20 mm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Iams, J. D., Johnson, F. F., Sonck, J., Sachs, L., Gebauer, C., & Samuels, P. (1995) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(95)91469-2 · Cited by 294
Gomez, R., Galasso, M., Romero, R., Mazor, M., Sorokin, Y., Gonçalves, L., & Treadwell, M. (1994) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(94)90014-0 · Cited by 278
Leitich, H., Brunbauer, M., Kaider, A., Egarter, C., & Husslein, P. (1999) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(99)70407-2 · Cited by 178
Krupa, F. G., Faltin, D., Cecatti, J. G., Surita, F. G. C., & Souza, J. P. (2006) · International Journal of Gynecology & Obstetrics · doi:10.1016/j.ijgo.2006.03.022 · Cited by 97
Metadata
- Venue
- Journal of Diagnostic Medical Sonography
- Publisher
- SAGE Publications
- Published
- 1994-01
- Volume
- 10
- Issue
- 1
- Pages
- 61-61
- ISSN
- 1552-5430 (ISSN-L)
- 8756-4793
- OpenAlex
- W190188936
- Cited by
- 139
- References
- 0
- FWCI
- 7.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of Threatened Preterm Delivery by Transvaginal Ultrasonographic Measurement of Cervical Length. https://app.cochat.ai/papers/10.1177/875647939401000133
- The paper
- Evaluation of Threatened Preterm Delivery by Transvaginal Ultrasonographic Measurement of Cervical Length. (1994). Journal of Diagnostic Medical Sonography. https://doi.org/10.1177/875647939401000133
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.