Phase contrast, a new method for the microscopic observation of transparent objects
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Different symbols correspond to distinct RI changes that can be read using Zernike phase-contrast microscopy33 (Extended Data Fig. 3; see section ‘Phase read’).”
From Laser writing in glass for dense, fast and efficient archival data storage (2026) · cites this paper as [33]
Citations
Cites
XV. On the theory of optical images, with special reference to the microscope
Rayleigh (1896) · The London Edinburgh and Dublin Philosophical Magazine and Journal of Science · doi:10.1080/14786449608620902 · Cited by 386
Diffraction Theory of the Knife-Edge Test and its Improved Form, The Phase-Contrast Method
Zernike, F., & Stratton, F. J. M. (1934) · Monthly Notices of the Royal Astronomical Society · doi:10.1093/mnras/94.5.377 · Cited by 383
Self-citationDie Darstellung von Chromosomen mittels des Phasenkontrastverfahrens
Michel, K. (1941) · Die Naturwissenschaften · doi:10.1007/bf01476461 · Cited by 28
Optische Studien nach der Methode der Schlierenbeobachtung
Töpler, A. (1867) · Annalen der Physik · doi:10.1002/andp.18672070603 · Cited by 26
Das Phasenkontrastverfahren Nach Zernike als Biologisches Forschungs-Mittel
Loos, W. (1941) · Journal of Molecular Medicine · doi:10.1007/bf02327345 · Cited by 19
The Spierer Lens and what it reveals in Cellulose and Protoplasm
Seijriz, W. (1931) · The Journal of Physical Chemistry · doi:10.1021/j150319a010 · Cited by 10
Spierer Lens and Colloidal Structure
Seifriz, W. (1936) · Industrial & Engineering Chemistry · doi:10.1021/ie50313a034 · Cited by 9
Microscopy of Starch by the Spiere Lens
Woodruff, S. (1938) · Industrial & Engineering Chemistry · doi:10.1021/ie50348a013 · Cited by 4
Research works printed but not linked: 5
- F. Zernike, Ned. T. Natuurk. (in the press).
- Abbe, 1873, Arch. mikrosk. Anat., 9, 431
- Abbe, 1873, Ges. Abband. I, 45, 273
- Spierer, 1926, Arch. sc. phys. nat., 8, 121
- Zernike, 1937, Physik. Z., 38, 994
Cited by
Items 301–400 of 1,000
In-situ observation of crystal growth and the mechanism
Tsukamoto, K. (2016) · Progress in Crystal Growth and Characterization of Materials · doi:10.1016/j.pcrysgrow.2016.04.005 · Cited by 22
Enhanced optical edge detection based on a Pancharatnam–Berry flat lens with a large focal length
Li, T., Yang, Y., Liu, X., Wu, Y., Zhou, Y., Huang, S., Li, X., & Huang, H. (2020) · Optics Letters · doi:10.1364/ol.395879 · Cited by 22
Shaping of Electron Beams Using Sculpted Thin Films
Roitman, D., Shiloh, R., Lu, P., Dunin‐Borkowski, R. E., & Arie, A. (2021) · ACS Photonics · doi:10.1021/acsphotonics.1c00951 · Cited by 22
PHASE-BASED SEGMENTATION OF CELLS FROM BRIGHTFIELD MICROSCOPY
Ali, R., Gooding, M. J., Christlieb, M., & Brady, M. (2007) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2007.356787 · Cited by 22
“Zernike showed that slightly defocusing the microscope improves the image contrast by modifying the optical paths of out-of-phase diffracted light rays, bringing them into view on the imaging plane [ 2 ].”
BackgroundConstantinou, P., Nicklee, T., Hedley, D. W., Damaskinos, S., & Wilson, B. C. (2005) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2005.857708 · Cited by 22
“It was first described by Frits Zernike [6], [7].”
MethodNoninterferometric phase determination
Paganin, D. M., & Nugent, K. A. (2001) · Advances in imaging and electron physics · doi:10.1016/s1076-5670(01)80104-x · Cited by 23
A New Method of Light Microscopy
Wilska, A. P. (1953) · Nature · doi:10.1038/171353a0 · Cited by 22
�ber den Schraubenbau der meiotischen Chromosomen
Ruch, F. (1950) · Chromosoma · doi:10.1007/bf00319484 · Cited by 22
Image formation in optical and electron transmission microscopy
Barnett, M. E. (1974) · Journal of Microscopy · doi:10.1111/j.1365-2818.1974.tb03962.x · Cited by 22
“It was shown by Zernike (1935) that such an object could be rendered visible by introducing by means of a ‘phase plate’ a 7~12 phase shift between diffracted and undiffracted light. Now in electron microscopy, specimens are as a rule phase objects. For structures much larger than the resolution limit the most importan…”
BackgroundInformation in 4D-STEM: Where it is, and How to Use it
Ma, D., Li, G., Muller, D. A., & Zeltmann, S. E. (2026) · Ultramicroscopy · doi:10.1016/j.ultramic.2026.114351 · Cited by 21
“transmission electron microscopy to 4D-STEM and provides analytical models and insights into full-field iterative ptychography, which blindly exploits all above contrast mechanisms.”
Fukutake, N. (2020) · Scientific Reports · doi:10.1038/s41598-020-73584-1 · Cited by 21
Real-time imaging of cellular forces using optical interference
Meek, A. T., Kronenberg, N. M., Morton, A., Liehm, P., Murawski, J., Dalaka, E., Booth, J. H. H., Powis, S. J., & Gather, M. C. (2021) · Nature Communications · doi:10.1038/s41467-021-23734-4 · Cited by 21
Phase contrast, phase retrieval and aberration balancing in shift-invariant linear imaging systems
Paganin, D. M., & Gureyev, T. E. (2007) · Optics Communications · doi:10.1016/j.optcom.2007.10.097 · Cited by 21
Multimodal computational microscopy based on transport of intensity equation
Li, J., Chen, Q., Sun, J., Zhang, J., & Zuo, C. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.12.126003 · Cited by 21
Balberg, M., Levi, M., Kalinowski, K., Barnea, I., Mirsky, S. K., & Shaked, N. T. (2017) · Journal of Biophotonics · doi:10.1002/jbio.201600186 · Cited by 21
Path-separated electron interferometry in a scanning transmission electron microscope
Yasin, F. S., Harvey, T. R., Chess, J., Pierce, J., & McMorran, B. J. (2018) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/aabc47 · Cited by 21
Dual wavelength digital holographic imaging of layered structures
Khoo, T. C., Sharikova, A. V., & Khmaladze, A. T. (2019) · Optics Communications · doi:10.1016/j.optcom.2019.124793 · Cited by 21
Presby, H. M., & Finkelstein, D. (1967) · Review of Scientific Instruments · doi:10.1063/1.1720602 · Cited by 21
Observing single cells in whole organs with optical imaging
Yang, X., Jiang, T., Liu, L., Zhao, X., Yu, X., Yang, M., Liu, G., & Luo, Q. (2023) · Journal of Innovative Optical Health Sciences · doi:10.1142/s1793545823300021 · Cited by 22
Single-Pixel Phase Microscopy Without 4f System
Zhao, Y., Hou, H.-Y., Han, J., Gao, S., Cui, S., Cao, D.-Z., Liang, B. L., Liu, H., & Zhang, S.-H. (2022) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2023.107474 · Cited by 20
Controllable tomography phase microscopy
Xiu, P., Zhou, X. Y., Kuang, C., Xu, Y., & Liu, X. (2014) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2014.10.001 · Cited by 20
Poola, P. K., & John, R. (2017) · Journal of Biomedical Optics · doi:10.1117/1.jbo.22.10.106001 · Cited by 20
“Knowing the absorption coefficient μ of the sample for a particular wavelength (550 nm) band of illumination, the thickness of the sample t can be derived directly from the Lambert–Beer’s law EQ-TARGET;temp:intralink-;e001;326;686Iðr⊥; z ¼ 0Þ ¼ Iine−μtðr⊥;zÞ; (1) where tðr⊥Þ is the projected thickness of the homogeneo…”
Fan, X., Healy, J. J., O’Dwyer, K., & Hennelly, B. M. (2019) · Applied Optics · doi:10.1364/ao.58.003104 · Cited by 20
Isotropic and anisotropic edge enhancement with a superposed-spiral phase filter
Li, Z., Zhao, S., & Wang, L. (2021) · Optics Express · doi:10.1364/oe.435927 · Cited by 22
Kheireddine, S., Smith, Z. J., Nicolau, D. V., & Wachsmann‐Hogiu, S. (2019) · Biomedical Optics Express · doi:10.1364/boe.10.004369 · Cited by 20
Rastogi, V., Agarwal, S., Dubey, S. K., Khan, G. S., & Shakher, C. (2020) · Applied Optics · doi:10.1364/ao.387620 · Cited by 20
Some Applications of Phase-contrast Microscopy
Barer, R. (1947) · Journal of Cell Science · doi:10.1242/jcs.s3-88.4.491 · Cited by 20
A Note on the Theory of Phase-Contrast Images
Hopkins, H. H. (1953) · Proceedings of the Physical Society Section B · doi:10.1088/0370-1301/66/4/411 · Cited by 20
Methods for visualization of peptidoglycan biosynthesis
Hsu, Y., Meng, X., & VanNieuwenhze, M. S. (2016) · Methods in microbiology · doi:10.1016/bs.mim.2016.10.004 · Cited by 21
Elektronenoptische Abbildung auf Grund der Wellenmechanik. I
Glaser, W., & Schiske, P. (1953) · Annalen der Physik · doi:10.1002/andp.19534470408 · Cited by 20
Compact, common path quantitative phase microscopic techniques for imaging cell dynamics
ANAND, A., Vora, P., Mahajan, S., Trivedi, V., Chhaniwal, V. K., SINGH, A., Leitgeb, R. A., & Javidi, B. (2014) · Pramana · doi:10.1007/s12043-013-0644-y · Cited by 19
Quantitative cell imaging using single beam phase retrieval method
Anand, A., Chhaniwal, V. K., & Javidi, B. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3589090 · Cited by 19
Sommargren, G. E., & Thompson, B. J. (1973) · Applied Optics · doi:10.1364/ao.12.002130 · Cited by 19
PHASE‐CONTRAST MICROSCOPY IN LIVING CELLS*
Rose, G. G. (1964) · Journal of the Royal Microscopical Society · doi:10.1111/j.1365-2818.1964.tb00517.x · Cited by 19
Tunable meta‐device for large depth of field quantitative phase imaging
Cheng, J., Geng, Z., Zhou, Y., Luo, Z., Liu, X., Xiang, Y., Zhou, J., & Chen, M. K. (2025) · Nanophotonics · doi:10.1515/nanoph-2024-0661 · Cited by 18
“Qualitative phase imaging methods, such as Zernike phase contrast [2] and differential interference contrast (DIC) [3], typically provide only a rough estimate of the phase information, which aids in visual observation but lacks the speci-ficity required for further research analysis.”
Zheng, C., Wang, T., Li, Z., Sun, R., Yang, D., Wang, S., Ouyang, B., Liu, F., Xiang, M., Hao, Q., et al. (2025) · Advanced imaging. · doi:10.3788/ai.2025.20001 · Cited by 18
Image-based polarization detection and material recognition
Lin, Y., Huang, H., Wang, Y.-J., Hsieh, H.-A., & Chen, P.-L. (2022) · Optics Express · doi:10.1364/oe.463332 · Cited by 18
Immersion liquid techniques in solid particle characterization: A review
Niskanen, I., Hibino, K., & Räty, J. A. (2015) · Talanta · doi:10.1016/j.talanta.2015.11.051 · Cited by 18
Light-neuron interactions: key to understanding the brain
Go, M. A., & Daria, V. R. (2017) · Journal of Optics · doi:10.1088/2040-8986/19/2/023002 · Cited by 18
“The invention of phase contrast microscopy (Zernike 1942) and other phaseimaging techniques (Nomarski 1955) which generate contrast for viewing otherwise poorly defined features enabled imaging of live unstained, transparent samples.”
BackgroundPreparing photographic plates of palynomorphs in the digital age
Riding, J. B., & Head, M. J. (2017) · Palynology · doi:10.1080/01916122.2017.1364052 · Cited by 18
Noise-robust pixel-super-resolved multi-image phase retrieval with coherent illumination
Shen, C., Guo, C., Geng, Y., Tan, J., Liu, S., & Liu, Z. (2018) · Journal of Optics · doi:10.1088/2040-8986/aae547 · Cited by 18
Condenser‐free contrast methods for transmitted‐light microscopy
Webb, K. F. (2014) · Journal of Microscopy · doi:10.1111/jmi.12181 · Cited by 18
“In standard (‘positive’) phase contrast, the phase ring is made optically thinner than the rest such that direct light is phase advanced at the image plane by λ/2 relative to light diffracted by the sample (dashed lines), most of which misses the phase ring (Zernike, 1942b).”
BackgroundInfluentialDetermining feulgen-DNA of individual chromosomes by fluorescence cytophotometry with incident light
Nitsch, B., Murken, J. D., & Br�ck, H. J. (1970) · Histochemistry and Cell Biology · doi:10.1007/bf00306427 · Cited by 18
Nomenclature of an image forming system
Mondal, P. (1975) · Applied Optics · doi:10.1364/ao.14.002319 · Cited by 18
Quantitative phase imaging for label‐free cytometry
Holden, E., Tárnok, A., & Popescu, G. (2017) · Cytometry Part A · doi:10.1002/cyto.a.23130 · Cited by 18
Advantages of Fresnel biprism-based digital holographic microscopy in quantitative phase imaging
Hayes-Rounds, C., Bogue-Jimenez, B., Garcia-Sucerquia, J. I., Skalli, O., & Doblas, A. (2020) · Journal of Biomedical Optics · doi:10.1117/1.jbo.25.8.086501 · Cited by 17
Spiral phase plate contrast in optical and electron microscopy
Juchtmans, R., Clark, L., Lubk, A., & Verbeeck, J. (2016) · Physical Review A · doi:10.1103/physreva.94.023838 · Cited by 19
Li, C., Chen, S., Klemba, M., & Zhu, Y. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.9.090501 · Cited by 21
“Tð2θSÞRðβ − φÞTðθBÞRðφ − αÞTðθCÞRðαÞ 1 0 ; (1)”
BackgroundPhysical significance of backscattering phase measurements
Hu, C., & Popescu, G. (2017) · Optics Letters · doi:10.1364/ol.42.004643 · Cited by 17
Shirkavand, A., Farivar, S., Mohajerani, E., Ataie‐Fashtami, L., & Ghazimoradi, M. H. (2019) · Lasers in Surgery and Medicine · doi:10.1002/lsm.23095 · Cited by 21
THE IMMERSION REFRACTOMETRY OF LIVING CELLS BY PHASE CONTRAST AND INTERFERENCE MICROSCOPY
Ross, K. F. A. (1961) · Elsevier eBooks · doi:10.1016/b978-0-12-395584-5.50005-6 · Cited by 17
Light Microscopy in Trypanosomes: Use of Fluorescent Proteins and Tags
Dean, S., & Sunter, J. D. (2020) · Methods in molecular biology · doi:10.1007/978-1-0716-0294-2_23 · Cited by 16
Quadri-wave lateral shearing interferometry: a versatile tool for quantitative phase imaging
Xie, J., Xie, H., Kong, C. Z., & Ling, T. (2024) · Journal of the Optical Society of America A · doi:10.1364/josaa.534348 · Cited by 16
Zhu, Y., Zhang, Z., & Barbastathis, G. (2014) · Optics Express · doi:10.1364/oe.22.028966 · Cited by 18
The Use of Hollow-Cone Illumination for Increasing Image Contrast in Microscopy
Mathews, W. W. (1953) · Transactions of the American Microscopical Society · doi:10.2307/3223521 · Cited by 16
Upconversion dark-field imaging with extended field of view at video frame rate
Junaid, S., Tidemand‐Lichtenberg, P., Pedersen, C., & Rodrigo, P. J. (2020) · Applied Optics · doi:10.1364/ao.384502 · Cited by 16
A modal approach for shape defect measurement based on global stereocorrelation
Etievant, D., Quinsat, Y., Thiébaut, F., & Hild, F. (2020) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2020.106030 · Cited by 16
Correlation-based Method for Automatic Mitotic Cell Detection in Phase Contrast Microscopy
Mirosław, Ł., Chorążyczewski, A., Buchholz, F., & Kittler, R. (2008) · Advances in soft computing · doi:10.1007/3-540-32390-2_74 · Cited by 16
Terahertz phonon polariton imaging
Wu, Q., Chen, Q., Zhang, B., & Xu, J. (2013) · Frontiers of Physics · doi:10.1007/s11467-013-0302-3 · Cited by 16
Anastasio, M. A., Chou, C., Zysk, A. M., & Brankov, J. G. (2010) · Journal of the Optical Society of America A · doi:10.1364/josaa.27.002648 · Cited by 18
“Well-known examples include in-line holography [1,2], analyzer-crystal-based phase-contrast imaging [3–5], Zernike phase-contrast imaging [6], and differential interference phase-contrast imaging [7].”
BackgroundBright-field TEM imaging of single molecules: Dream or near future?
Malac, M., Beleggia, M., Egerton, R. F., & Zhu, Y. (2006) · Ultramicroscopy · doi:10.1016/j.ultramic.2006.05.001 · Cited by 16
Phase retrieval low energy electron microscopy
Yu, R. P., Kennedy, S. M., Paganin, D. M., & Jesson, D. E. (2009) · Micron · doi:10.1016/j.micron.2009.10.010 · Cited by 16
Generalised phase contrast: microscopy, manipulation and more
Palima, D. Z., & Glückstad, J. (2010) · Contemporary Physics · doi:10.1080/00107510903462257 · Cited by 16
“For example, a widely known CPI implementation called the Zernike phase contrast method 1 , 2 uses the undiffracted or zero-order component to synthesise the reference wave.”
MethodProper Alignment and Adjustment of the Light Microscope
Salmon, E. D., & Canman, J. C. (2002) · Current Protocols in Immunology · doi:10.1002/0471142735.im2101s48 · Cited by 16
“The technique was discovered by Zernike, in 1942, who received the Nobel prize for his achievement (Zernike, 1942, 1955, 1958).”
MethodFourier phase in Fourier-domain optical coherence tomography
Uttam, S., & Liu, Y. (2015) · Journal of the Optical Society of America A · doi:10.1364/josaa.32.002286 · Cited by 16
“In microscopic imaging, where the media are often cells and tissue samples with low intrinsic contrast under bright-field imaging conditions, phase contrast [2,3] and differential interference phase contrast [4,5] microscopes are extensively used to noninvasively visualize the structure and dynamics of these unlabeled…”
BackgroundProper Alignment and Adjustment of the Light Microscope
Salmon, E. D., & Canman, J. C. (1998) · Current Protocols in Cell Biology · doi:10.1002/0471143030.cb0401s00 · Cited by 16
“The technique was discovered by Zernike, in 1942, who received the Nobel prize for his achievement (Zernike, 1942, 1955, 1958).”
MethodKim, B.-M., Park, S., & Kim, E. (2017) · Optics Express · doi:10.1364/oe.25.006151 · Cited by 16
Phase contrast imaging of red blood cells using digital holographic interferometric microscope
Kumar, V., Khan, G. S., & Shakher, C. (2017) · International Conference on Applications of Optics and Photonics · doi:10.1117/12.2276335 · Cited by 16
“* * 2 2 ) , ( RO O R O R Y X H + + + = (1)”
Mohsin, A. S. M., & Salim, M. B. (2018) · International Journal of Nanomedicine · doi:10.2147/ijn.s175523 · Cited by 16
“Qualitative techniques such as phase contrast microscopy 22 and differential interference microscopy 23 allow spatial distribution visualization of RIs for individual cells or intracellular organelles in high contrast cellular imaging.”
High-resolution transmission electron microscopy with an electrostatic Zach phase plate
Hettler, S., Dries, M., Zeelen, J., Oster, M. E., Schröder, R. R., & Gerthsen, D. (2016) · New Journal of Physics · doi:10.1088/1367-2630/18/5/053005 · Cited by 16
Effects of the pore-forming agent nystatin on giant phospholipid vesicles
Kristanc, L., Svetina, S., & Gomišček, G. (2011) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/j.bbamem.2011.11.036 · Cited by 17
Computational aberration determination and correction
Faulkner, H. M. L., Allen, L. J., Oxley, M. P., & Paganin, D. M. (2003) · Optics Communications · doi:10.1016/s0030-4018(02)02298-8 · Cited by 16
A New Single-control Micromanipulator
Barer, R., & Saunders-Singer, A. E. (1948) · Journal of Cell Science · doi:10.1242/jcs.s3-89.8.439 · Cited by 16
Piller, H. (1952) · Contributions to Mineralogy and Petrology · doi:10.1007/bf01112930 · Cited by 16
Quantum Limits of Transmission Electron Microscopy
Dwyer, C. (2023) · Physical Review Letters · doi:10.1103/physrevlett.130.056101 · Cited by 23
Ilo-Okeke, E. O., & Byrnes, T. (2016) · Physical Review A · doi:10.1103/physreva.94.013617 · Cited by 15
Tunable Ampere phase plate for low dose imaging of biomolecular complexes
Tavabi, A. H., Beleggia, M., Migunov, V., Savenko, A., Öktem, O., Dunin‐Borkowski, R. E., & Pozzi, G. (2018) · Scientific Reports · doi:10.1038/s41598-018-23100-3 · Cited by 15
Li, K., Sun, C., Klose, T., Irimia, J. M., Vago, F. S., Vidal, R., & Jiang, W. (2019) · Journal of Structural Biology · doi:10.1016/j.jsb.2019.03.007 · Cited by 15
“While the physical principle of phase plates has been well-established since 1942 (Zernike, 1942) and its application to light microscopy succeeded quickly, the implementation for TEM has proven to be very difficult.”
BackgroundLabel free optical transmission tomography for biosystems: intracellular structures and dynamics
Mazlin, V., Thouvenin, O., Alhaddad, S., Boccara, M., & Boccara, C. (2022) · Biomedical Optics Express · doi:10.1364/boe.453586 · Cited by 15
“By using one of the phase contrast techniques such as the classical one from Zernike [5,20], differential interference contrast (DIC) microscopy [21] or defocusing microscopy [22] it is possible to convert phase variations, caused by the light propagating through the thickness of the sample, into the intensity detecta…”
BackgroundMethodSun, T., Zhuo, Z., Zhang, W., Lu, J., & Lu, P. (2018) · Laser Physics · doi:10.1088/1555-6611/aae036 · Cited by 15
Quantitative Phase Imaging: Principles and Applications
Hu, C., & Popescu, G. (2019) · Biological and medical physics, biomedical engineering · doi:10.1007/978-3-030-21722-8_1 · Cited by 21
Troiani, F., Rotunno, E., Frabboni, S., Ravelli, R. B. G., Peters, P. J., Karimi, E., & Grillo, V. (2020) · Physical Review A · doi:10.1103/physreva.102.043510 · Cited by 15
III.—A VECTOR THEORY OF PHASE CONTRAST AND INTERFERENCE CONTRAST. III. NEGATIVE PHASE CONTRAST
Barer, R. (1953) · Journal of the Royal Microscopical Society · doi:10.1111/j.1365-2818.1953.tb02345.x · Cited by 15
“OPTICAL MEMBRANES”: A COMMON ARTEFACT
Oettlé, A. G. (1950) · Journal of the Royal Microscopical Society · doi:10.1111/j.1365-2818.1950.tb04432.x · Cited by 15
Self-calibrating common-path interferometry
Porras-Aguilar, R., Falaggis, K., Ramirez-San-Juan, J. C., & Ramos-Garcia, R. (2015) · Optics Express · doi:10.1364/oe.23.003327 · Cited by 14
Phase and fluorescence imaging with a surprisingly simple microscope based on chromatic aberration
Mandula, O., Kleman, J.-P., Lacroix, F., Allier, C. P., Fiole, D., Hervé, L., Blandin, P., Kraemer, D., & Morales, S. (2020) · Optics Express · doi:10.1364/oe.28.002079 · Cited by 14
Information transfer as a framework for optimized phase imaging
Koppell, S. A., & Kasevich, M. A. (2021) · Optica · doi:10.1364/optica.412129 · Cited by 16
“Zernike developed the first method for optically-generated phase contrast using a phase-shifting filter in the backfocal plane of the objective lens (or some conjugate plane) [7,8].”
MethodLee, D. J., Han, K., Lee, H. J., & Weiner, A. M. (2015) · Applied Optics · doi:10.1364/ao.54.005346 · Cited by 14
High-Resolution, Low-Noise Imaging in THz Polaritonics
Werley, C. A., Teo, S. M., Ofori-Okai, B. K., Sivarajah, P., & Nelson, K. A. (2013) · IEEE Transactions on Terahertz Science and Technology · doi:10.1109/tthz.2013.2250580 · Cited by 14
“Phase contrast imaging is a method that generates contrast in transparent samples with variations in thickness or refractive index [24], and is often used in biology to image cells.”
MethodImpedance Sensing for Monitoring Neuronal Coverage and Comparison With Microscopy
Wiertz, R. W. F., Rutten, W. L. C., & Marani, E. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2055052 · Cited by 14
“The absolute values differ considerably, but also the detailed course over time, the IS-measured curve showing the most detail.”
BackgroundQuantitative polarized light microscopy using spectral multiplexing interferometry
Li, C., & Zhu, Y. (2015) · Optics Letters · doi:10.1364/ol.40.002622 · Cited by 17
Pandiyan, V. P., Khare, K., & John, R. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.10.106003 · Cited by 14
“EQ-TARGET;temp:intralink-;e001;326;608 Hðx; yÞ 1⁄4 jOðx; yÞj2 þ jRðx; yÞj2 þOðx; yÞR ðx; yÞ þ Rðx; yÞO ðx; yÞ: (1)”
Oriented Ring Cracks on Diamond
Tolansky, S., & Halperin, A. (1954) · Proceedings of the Physical Society Section B · doi:10.1088/0370-1301/67/6/304 · Cited by 14
Compact Zernike phase contrast x-ray microscopy using a single-element optic
von Hofsten, O., Bertilson, M. C., Lindblom, M., Holmberg, A., & Vogt, U. (2008) · Optics Letters · doi:10.1364/ol.33.000932 · Cited by 14
Harmonically-related diffraction gratings-based interferometer for quadrature phase measurements
Yaqoob, Z., Wu, J., Cui, X., Heng, X., & Yang, C. (2006) · Optics Express · doi:10.1364/oe.14.008127 · Cited by 14
Johnson, H. M., & Parsons, D. F. (1973) · Journal of Microscopy · doi:10.1111/j.1365-2818.1973.tb03799.x · Cited by 14
Image Contrast in Phase-Contrast Microscopy
Keck, P. H., & Brice, A. T. (1949) · Journal of the Optical Society of America · doi:10.1364/josa.39.000507 · Cited by 14
Local Optimization of Wave-fronts for optimal sensitivity PHase Imaging (LowPhi)
Juffmann, T., Sommer, A. D. L. R., & Gigan, S. (2019) · Optics Communications · doi:10.1016/j.optcom.2019.124484 · Cited by 13
“Since α is often fixed (e.g. in phase contrast microscopy [5]), this leads to a sensitivity that goes to zero for certain regions of the sample.”
BackgroundSilveira, A., Greving, I., Longo, E., Scheel, M., Weitkamp, T., Fleck, C., Shahar, R., & Zaslansky, P. (2024) · Journal of Synchrotron Radiation · doi:10.1107/s1600577523009852 · Cited by 13
Smart hybrid microscopy for cell-friendly detection of rare events
Stepp, W. L., Tortarolo, G., Landoni, J. C., Durmuş, E., Alvarez, S. N. R., Douglass, K. M., WEIGERT, M. G., & Manley, S. (2026) · Nature Communications · doi:10.1038/s41467-025-68168-4 · Cited by 13
“To assess phototoxicity, we also measured nuclear envelope integrity, a hallmark of cell death, and observed that it was compromised in 50% of cells after only 5 minutes of fluorescence imaging at 1 fps (Fig.”
Metadata
- Authors
- Zernike, F.
- Corresponding author
- Zernike, F.
- Venue
- Physica
- Publisher
- Elsevier BV
- Published
- 1942-07
- Volume
- 9
- Issue
- 7
- Pages
- 686-698
- ISSN
- 0031-8914 (ISSN-L)
- OpenAlex
- W1980774072
- Semantic Scholar
- e3d798588553ec88195a4ec61df3f175d9094154
- Cited by
- 1,068
- References
- 8
- Citations by year
- 2026: 58 · 2025: 48 · 2024: 41 · 2023: 33 · 2022: 52 · 2021: 58 · 2020: 50 · 2019: 89 · 2018: 62 · 2017: 56 · 2016: 46 · 2015: 56 · 2014: 43 · 2013: 19 · 2012: 34
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Physica (publishedVersion)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Digital Holography and Microscopy
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Optical measurement and interference techniques
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced optical system design
- Keywords
- phase contrast microscopy, phase gratings, transparent objects, diffraction theory, schlieren method, refractive index difference, diffraction halo
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.