Phase contrast, a new method for the microscopic observation of transparent objects
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Different symbols correspond to distinct RI changes that can be read using Zernike phase-contrast microscopy33 (Extended Data Fig. 3; see section ‘Phase read’).”
From Laser writing in glass for dense, fast and efficient archival data storage (2026) · cites this paper as [33]
Citations
Cites
XV. On the theory of optical images, with special reference to the microscope
Rayleigh (1896) · The London Edinburgh and Dublin Philosophical Magazine and Journal of Science · doi:10.1080/14786449608620902 · Cited by 386
Diffraction Theory of the Knife-Edge Test and its Improved Form, The Phase-Contrast Method
Zernike, F., & Stratton, F. J. M. (1934) · Monthly Notices of the Royal Astronomical Society · doi:10.1093/mnras/94.5.377 · Cited by 383
Self-citationDie Darstellung von Chromosomen mittels des Phasenkontrastverfahrens
Michel, K. (1941) · Die Naturwissenschaften · doi:10.1007/bf01476461 · Cited by 28
Optische Studien nach der Methode der Schlierenbeobachtung
Töpler, A. (1867) · Annalen der Physik · doi:10.1002/andp.18672070603 · Cited by 26
Das Phasenkontrastverfahren Nach Zernike als Biologisches Forschungs-Mittel
Loos, W. (1941) · Journal of Molecular Medicine · doi:10.1007/bf02327345 · Cited by 19
The Spierer Lens and what it reveals in Cellulose and Protoplasm
Seijriz, W. (1931) · The Journal of Physical Chemistry · doi:10.1021/j150319a010 · Cited by 10
Spierer Lens and Colloidal Structure
Seifriz, W. (1936) · Industrial & Engineering Chemistry · doi:10.1021/ie50313a034 · Cited by 9
Microscopy of Starch by the Spiere Lens
Woodruff, S. (1938) · Industrial & Engineering Chemistry · doi:10.1021/ie50348a013 · Cited by 4
Research works printed but not linked: 5
- F. Zernike, Ned. T. Natuurk. (in the press).
- Abbe, 1873, Arch. mikrosk. Anat., 9, 431
- Abbe, 1873, Ges. Abband. I, 45, 273
- Spierer, 1926, Arch. sc. phys. nat., 8, 121
- Zernike, 1937, Physik. Z., 38, 994
Cited by
Items 601–700 of 1,000
Pattern generation by inverse phase contrast
Arieli, Y. S., Eisenberg, N. P., & Lewis, A. (1997) · Optics Communications · doi:10.1016/s0030-4018(97)00065-5 · Cited by 5
Carrier Suppression and Restoration in Hologram Microscopy*
Anderson, W. L. (1969) · Journal of the Optical Society of America · doi:10.1364/josa.59.000224 · Cited by 5
Phase Contrast Observations of Flames
Saunders, M. J., & Smith, A. G. (1956) · Journal of Applied Physics · doi:10.1063/1.1722318 · Cited by 5
Black lipid membranes studied by x-ray phase contrast imaging
Beerlink, A. (2011) · Göttingen series in x-ray physics · doi:10.17875/gup2011-108 · Cited by 5
Anonymous, & Morgan, K. S. (2026) · Physical Review A · doi:10.1103/zsg4-f26q · Cited by 4
“Indeed, upon making the asymmetric first-order finite-difference approximation The contribution of the second line of the above equation may be spoken of as “out of focus contrast” [39–42] induced by the locally converging or diverging character of the flow.”
InfluentialHanszen, K.-J. (2018) · Advances in imaging and electron physics · doi:10.1016/bs.aiep.2018.04.001 · Cited by 4
Generalised Cornu spirals: an experimental study using hard x-rays
Werdiger, F., Kitchen, M. J., & Paganin, D. M. (2016) · Optics Express · doi:10.1364/oe.24.010620 · Cited by 4
Xiong, M., Ma, Y., Wu, J., Su, R., Zhou, P., & Si, L. (2024) · Optics Express · doi:10.1364/oe.541467 · Cited by 4
Color-multiplexed 3D differential phase contrast microscopy with optimal annular illumination
Wang, J., Zhao, X., Wang, Y., & Li, D. (2024) · Optics Express · doi:10.1364/oe.545480 · Cited by 5
Kim, J., Barroso, Á., Ketelhut, S., Schnekenburger, J., Kemper, B., & Picazo-Bueno, J. Á. (2025) · Sensors · doi:10.3390/s25092675 · Cited by 4
“Methods like bright-field (BF) microscopy [1], Zernike phase contrast [2], differential interference contrast (DIC) [3], and digital holographic microscopy (DHM) [4] provide imaging of native cell populations without the requirement for external markers, which may alter the investigated sample.”
V. S. Ignatowsky: Diffraction by a Lens of Arbitrary Aperture
Braat, J. J. M., & Török, P. (2019) · Cambridge University Press eBooks · doi:10.1017/9781108552264.019 · Cited by 4
Ganoza-Quintana, J. L., Arce-Diego, J. L., & Fanjul-Vélez, F. (2022) · Sensors · doi:10.3390/s22239295 · Cited by 4
“Low contrast thin biological tissues are usually observed by phase-contrast microscopy (PCM), typical for cell cultures [18].”
BackgroundZhan, 仝. T., Xuesong, 任. R., Zihan, 张. Z., Yubin, 苗. M., & Guoxiang, 孟. M. (2024) · Laser & Optoelectronics Progress · doi:10.3788/lop232435 · Cited by 4
Laser-scanning optical-frequency-comb microscopy for multimodal imaging
Kajiwara, S., Hase, E., Nakano, S., Ootani, K., Okabe, T., Koresawa, H., Asahara, A., Yoshii, K., Yamamoto, H., Minoshima, K., et al. (2024) · Japanese Journal of Applied Physics · doi:10.35848/1347-4065/ad98d2 · Cited by 4
Barty, A., Hau‐Riege, S. P., Stearns, D. G., Clift, M., Mirkarimi, P. B., Gullikson, E. M., Chapman, H. N., & Sweeney, D. (2004) · Applied Optics · doi:10.1364/ao.43.006545 · Cited by 4
Study on the deformation of endothelial cells using a bio-inspired in vitro disease model
Seo, E., Seo, K. W., Park, J. W., Lee, T. G., & Lee, S. J. (2014) · Microvascular Research · doi:10.1016/j.mvr.2014.02.003 · Cited by 4
Quantitative theory of ideal phase‐contrast microscopy, taking object width into account
Goldstein, D. J. (1991) · Journal of Microscopy · doi:10.1111/j.1365-2818.1991.tb03198.x · Cited by 4
Enhancing entangled-state phase estimation by combining classical and quantum protocols
Shin, H., Magaña‐Loaiza, O. S., Malik, M., O’Sullivan, M. N., & Boyd, R. W. (2013) · Optics Express · doi:10.1364/oe.21.002816 · Cited by 4
Development and preliminary results of phase contrast imaging diagnostic on HL-2A
Gong, S. B., Yu, Y., Xu, M., Sun, A. P., Lan, T., Liu, H., Zhong, W. L., Shi, Z. B., Wang, H. J., Wu, Y. F., et al. (2019) · Fusion Engineering and Design · doi:10.1016/j.fusengdes.2019.01.015 · Cited by 4
Label-free color staining of quantitative phase images
Fan, X., Healy, J. J., O’Dwyer, K., & Hennelly, B. M. (2020) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2020.106049 · Cited by 4
Second Harmonic Imaging Enhanced by Deep Learning Decipher
Fan, W., Chen, T., Gil, E. M., Zhu, S., Yakovlev, V. V., Wang, D., & Zhang, D. (2021) · ACS Photonics · doi:10.1021/acsphotonics.1c00395 · Cited by 7
Non-interferometric accurate phase imaging via linear-convergence iterative optimization
Huang, J., Pan, A., Jin, H., Meng, G., & Ye, Q. (2021) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2021.106630 · Cited by 4
“spectrum [27].”
Complex wave and phase retrieval from a single off-axis interferogram
Luo, G., He, Y., Shu, X. J., Zhou, R., & Blu, T. (2022) · Journal of the Optical Society of America A · doi:10.1364/josaa.473726 · Cited by 4
Simulation of Phase Effects in Imaging for Mesoscale NDE
Aufderheide, M. B. (2005) · AIP conference proceedings · doi:10.1063/1.1916739 · Cited by 4
Novel free-form optical pairs for tunable focalizers
Ojeda‐Castañeda, J., Gomez-Sarabia, C. M., & Ledesma, S. (2014) · Journal of Optics · doi:10.1007/s12596-014-0194-9 · Cited by 4
“Third, we combine our two previous results for describing a tunable version of a radial Schlieren technique [11–14], and a tunable version of the phase contrast technique [15].”
MethodPhase contrast microscopy with fringe contrast adjustable by using grating-based phase-shifter
Zheng, J., Yao, B., Gao, P., & Ye, T. (2012) · Optics Express · doi:10.1364/oe.20.016077 · Cited by 4
Progress of plasma density fluctuation measurements with phase contrast imaging on HL-2A tokamak
Gong, S., Yu, Y., Xu, M., Sun, A. P., Lan, T., Nie, L., Ke, R., Long, T., Liu, H., Wu, Y. F., et al. (2019) · Plasma Science and Technology · doi:10.1088/2058-6272/ab0054 · Cited by 4
Dohet‐Eraly, J., Méès, L., Olivier, T., Dubois, F. P. B., & Fournier, C. (2020) · Unconventional Optical Imaging · doi:10.1117/12.2557852 · Cited by 4
On the Basic Approximation in the Theory of the Phase Contrast Microscopy
Kahn, F. D. (1955) · Proceedings of the Physical Society Section B · doi:10.1088/0370-1301/68/12/312 · Cited by 4
La cinétique de la vacuole contractile chez Amoeba proteus: effets de la lumière panchromatique
Forget, J., & Couillard, P. (1983) · Canadian Journal of Zoology · doi:10.1139/z83-068 · Cited by 4
Hirsch, T., & Hager, H. (1955) · European Archives of Psychiatry and Clinical Neuroscience · doi:10.1007/bf00342794 · Cited by 4
OBSERVATIONS ON MICROSCOPE CONDENSERS, OBJECTIVES, AND EYEPIECES
Payne, B. O. (1950) · Journal of the Royal Microscopical Society · doi:10.1111/j.1365-2818.1950.tb04441.x · Cited by 4
Dark-field (Diffrimoscopic) Images of Periodic Objects (Coherent Illumination)
Gupta, S. V., & Sen, D. (1972) · Optica Acta International Journal of Optics · doi:10.1080/713818540 · Cited by 4
Scheid, A., Song, Q., Ribet, S. M., Ophus, C., Suyolcu, Y. E., Schlom, D. G., Heil, T., & van Aken, P. A. (2025) · Advanced Materials Interfaces · doi:10.1002/admi.202500218 · Cited by 3
Physics-informed generative real-time lens-free imaging
Liu, R. B., Liu, Z., Wolf, M. G. A., Purohit, K. P., Fritz, G., Feng, Y., Hansen, C. G., Bagnaninchi, P., Solvas, X. C. I., & Yang, Y. (2025) · Cell Reports Physical Science · doi:10.1016/j.xcrp.2025.102792 · Cited by 3
Multiparametric quantification of bacterial cells using digital holographic microscopy
Cano, Á., Sanz-Jiménez, A., Malvar, Ó., Ruz, J. J., Kosaka, P. M., García‐López, S., Calleja, M., & Tamayo, J. (2025) · Scientific Reports · doi:10.1038/s41598-025-24917-5 · Cited by 3
“For instance, phase contrast, proposed by Zernike 12 , and differential interference contrast 13 , significantly enhance contrast and allow imaging of transparent samples; however, these techniques still cannot quantify the dry mass.”
Li, Y., Zhou, W., Zhang, Y., Huang, X., Chen, Y., Yuan, M., & Yang, J. (2025) · Nanophotonics · doi:10.1515/nanoph-2025-0494 · Cited by 3
“Representative examples include Zernike phase-contrast imaging [8], [9] and differential interference contrast (DIC) imaging [10].”
Integrated light field sensors: From nanophotonic architectures to computational perception
Zheng, Z.-H., Chen, Y., Luo, S., Chen, Z., & Chen, J. (2026) · Applied Physics Reviews · doi:10.1063/5.0289443 · Cited by 3
Future directions in all-optical label-free single-molecule sensing
Masuda, K., Gordon, R., Kukura, P., Langhammer, C., Oh, S., Vollmer, F., & Zijlstra, P. (2026) · npj Biosensing · doi:10.1038/s44328-025-00069-4 · Cited by 4
“This approach has been originally popularized in the form of phase contrast microscopy 81 , and further re fi ned in various implementations such as re fl ection imaging 82,83 .”
Advancing quantum imaging: Electrical tunability enabled by versatile liquid crystals
Zhu, D., Sj, D., Sun, R., Li, Z., Chen, W., Zhang, Y., Liu, S.-J., Wang, Y.-M., Chen, F.-T., Chen, P., et al. (2026) · Science Advances · doi:10.1126/sciadv.adz8962 · Cited by 3
“Recently, it has witnessed sustained demands in machine vision ( 2 ), autonomous vehicles ( 3 ), and microscopy ( 4 ).”
Phase contrast tomography (PCT)
Ma, Y., Feng, W., Lei, Y., Li, Z., Ma, L., Zhou, S., Shu, Y., Tan, Q., Zuo, C., & Gao, P. (2026) · Optics Express · doi:10.1364/oe.588947 · Cited by 3
Property-driven analysis of glasses for data storage via femtosecond laser writing
Lawson, T., Drevinskas, R., Sakakura, M., Whittaker, C., Donnelly, A., Thomsen, B. C., & Black, R. (2026) · Optica · doi:10.1364/optica.592661 · Cited by 4
Gedde, U. W. (1999) · Springer eBooks · doi:10.1007/978-94-011-0543-9_11 · Cited by 3
Optophysiology of cardiomyocytes: characterizing cellular motion with quantitative phase imaging
Cordeiro, C., Abiliez, O., Goetz, G., Gupta, T., Zhuge, Y., Solgaard, O., & Palanker, D. (2017) · PubMed · doi:10.6084/m9.figshare.c.3819112.v1 · Cited by 3
Phase Microscopy to Enhance Contrast
Masters, B. R. (2020) · Springer series in optical sciences/SPringer series in optical sciences · doi:10.1007/978-3-030-21691-7_12 · Cited by 3
Tu, J., Brennan, P., Lewis, S. J., & Taba, S. T. (2021) · Journal of Medical Radiation Sciences · doi:10.1002/jmrs.536 · Cited by 3
Kashyap, Y. (2022) · Springer eBooks · doi:10.1007/978-981-16-6273-7_6 · Cited by 3
Common-path quantitative phase imaging by propagation through a sinusoidal intensity mask
Ayubi, G. A., Lakatos, M. F., Casaballe, N., & Frins, E. M. (2023) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2023.107805 · Cited by 3
Optical vortex coronagraphy for high-contrast imaging of femtosecond laser filaments
Liang, Q., Zhang, Q., Wang, M., Mou, Y., Zhang, E., Cheng, Q., Swartzlander, G. A., & Liu, Y. (2023) · Optics Letters · doi:10.1364/ol.504931 · Cited by 3
Nikolaeva, T. Y., & Petrov, N. V. (2015) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2179263 · Cited by 3
“There are cases when the particles in a volume almost completely overlap (Figure 4a) or exactly superpose (Figure 4d), then forklets can not be traced on holograms, but the inequality (12) will be satisfied.”
BackgroundPu, Y., Hsieh, C., Grange, R., & Psaltis, D. (2010) · Advances in imaging and electron physics · doi:10.1016/s1076-5670(10)60003-1 · Cited by 3
Advanced Label-Free Optical Methods for Spermatozoa Quality Assessment and Selection
Angelis, A. D., Ferrara, M. A., Coppola, G., & Luca, A. C. D. (2018) · InTech eBooks · doi:10.5772/intechopen.71028 · Cited by 3
“Respect to differential interference contrast (DIC) microscopy [29] or Nomarski/Zernike’s phase contrast [30], the QPM gives a quantitative measure of the optical path difference (OPD) at each point in the sample.”
BackgroundSato, M., Masuta, J., & Nishidate, I. (2020) · Applied Optics · doi:10.1364/ao.405226 · Cited by 3
Huang, J., Bao, Y., & Gaylord, T. K. (2021) · Journal of the Optical Society of America A · doi:10.1364/josaa.417407 · Cited by 3
Zdora, M. (2021) · Springer theses · doi:10.1007/978-3-030-66329-2_2 · Cited by 3
Claus, D., Hennenlotter, J., Liting, Q., Pedrini, G., Stenzl, A., & Osten, W. (2018) · Applied Sciences · doi:10.3390/app8112147 · Cited by 3
Basic Principles and Applications of Live Cell Microscopy Techniques: A Review
Mekuria, T. A., & Kinde, M. Z. (2022) · World s Veterinary Journal · doi:10.54203/scil.2022.wvj43 · Cited by 3
“Superimposition of these two light components later by the analyzer results in images having contrast (Zernike, 1942; Murphy and Davidson, 2012).”
BackgroundRefractive index and volume fractions of various cellular components of plankton
Kamowski, M., Mojica, K. D. A., Lange, K., & Zhang, X. (2023) · Optics Express · doi:10.1364/oe.502465 · Cited by 3
Sun, T., Ke, S., Sui, W., Zhang, W., Lu, P., Qi, D., Yang, B., Wei, J., Zhang, W., & Zheng, H. Y. (2024) · Journal of Laser Applications · doi:10.2351/7.0001360 · Cited by 3
Enhanced image transmission via four-wave mixing with assisted spiral phase contrast in hot atoms
Li, Z., Wang, Z., & Yu, B. (2024) · Optics Communications · doi:10.1016/j.optcom.2024.131084 · Cited by 4
Feature-Level Image Fusion Scheme for X-Ray Multi-Contrast Imaging
Zuo, Z., Luo, J., Liu, H., Zheng, X., & Zan, G. (2025) · Electronics · doi:10.3390/electronics14010210 · Cited by 3
Phase Imaging in Plant Cells and Tissues
Sarafis, V. (2012) · Elsevier eBooks · doi:10.1016/b978-0-12-415871-9.00004-1 · Cited by 3
Fourier Transform Light Scattering of Tissues
Kim, T., Sridharan, S., & Popescu, G. (2012) · Springer eBooks · doi:10.1007/978-1-4614-5176-1_7 · Cited by 3
On the Thompson-Wolf experiment: a study with laser sources
Paredes-Barato, D., & Calvo, M. L. (2010) · Journal of the European Optical Society Rapid Publications · doi:10.2971/jeos.2010.10051s · Cited by 3
“The key contribution was done by Frits Zernike who in 1938 published a seminal paper on the fundamentals of partial coherence [4].”
BackgroundClassification of Tumor cells in Phase-contrast Microscopy Image using Fourier Descriptor
Kang, M.-S., Lee, J.-E., Kim, H.-R., & Kim, M. (2012) · Journal of Biomedical Engineering Research · doi:10.9718/jber.2012.33.4.169 · Cited by 3
Bányász, I. (2004) · Optics Communications · doi:10.1016/j.optcom.2004.09.039 · Cited by 3
Phase and intensity control through diffractive optical elements in X-ray microscopy
Fabrizio, E. M. D., Cojoc, D., Cabrini, S., Altissimo, M., Kaulich, B., Wilhein, T., Susini, J., & Dhez, O. (2005) · Journal of Electron Spectroscopy and Related Phenomena · doi:10.1016/j.elspec.2005.01.262 · Cited by 3
Schlieren confocal microscopy for phase-relief imaging
Xie, H., Jin, D., Yu, J., Peng, T., Ding, Y., Zhou, C., & Xi, P. (2014) · Optics Letters · doi:10.1364/ol.39.001238 · Cited by 3
Aberration‐corrected microscopy for structural biology applications
Ziegler, A., Rockel, B., Hegerl, R., Freitag, B. H., Lücken, U., & Plitzko, J. M. (2009) · Journal of Microscopy · doi:10.1111/j.1365-2818.2008.03106.x · Cited by 3
“…such as a Zernike-type phase plate or an electrostatic phase plate that shifts the entire transfer function such that the CTF does not begin at zero but at maximum contrast transmission (Zernike, 1942; Unwin, 1971; Unwin, 1972; Nagayama, 2005; Daney & Nagayama, 2008; Yamaguchi et al., 2008).”
BackgroundVibrational phase contrast CARS microscopy for quantitative analysis
Jurna, M., Garbacik, E. T., Korterik, J. P., Otto, C., Herek, J. L., & Offerhaus, H. L. (2010) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.840178 · Cited by 3
Emulated super-resolution using quantitative phase microscopy
Nugent, K. A., & Bellair, C. J. (2003) · Micron · doi:10.1016/s0968-4328(03)00060-x · Cited by 3
Coronagraph-integrated wavefront sensing with a sparse aperture mask
Subedi, H. B., Zimmerman, N. T., Kasdin, N. J., Cavanagh, K., & Riggs, A. J. E. (2015) · Journal of Astronomical Telescopes Instruments and Systems · doi:10.1117/1.jatis.1.3.039001 · Cited by 3
High resolution quantitative phase imaging of live cells with constrained optimization approach
Pandiyan, V. P., Khare, K., & John, R. (2016) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2209289 · Cited by 3
“Zernike’s novel invention of phase contrast microscope [1] solves this problem by converting the phase change into amplitude to improve contrast but fails to quantify the phase.”
Low cost label-free live cell imaging for biological samples
Seniya, C., Towers, C. E., & Towers, D. P. (2017) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2246680 · Cited by 3
“INTRODUCTION The structural details and qualitative information of transparent biological cells and tissues are usually imaged with improved clarity by phase-contrast ([1]), and differential interference contrast microscopy [2] without special sample preparation.”
BackgroundOff-axis digital holography with multiplexed volume Bragg gratings
Puyó, L., Huignard, J., & Atlan, M. (2018) · Applied Optics · doi:10.1364/ao.57.003281 · Cited by 3
Interference phase-contrast imaging technology without beam separation
Nishiwaki, S., Narumi, K., & Korenaga, T. (2019) · Scientific Reports · doi:10.1038/s41598-018-38359-9 · Cited by 3
Foster, L. V. (1950) · Journal of the Optical Society of America · doi:10.1364/josa.40.000275 · Cited by 3
Vibrational phase contrast CARS microscopy
Jurna, M. (2010) · doi:10.3990/1.9789036530552 · Cited by 3
“The detection of the phase of the vibrational motion can be regarded as a vibrational extension of the linear (refractive index) phase contrast microscopy introduced by Zernike in 1933 [1].”
BackgroundA study of reversed shear Alfvén eigenmodes in Alcator C-Mod with phase contrast imaging
Edlund, E. M. (2009) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 3
Teoria elementare del microscopio a contrasto di fase
Ballerini, L. (1948) · Il Nuovo Cimento · doi:10.1007/bf02780830 · Cited by 3
Microscopic probing and manipulation of ultracold fermions
Müller, T. (2011) · Repository for Publications and Research Data (ETH Zurich) · doi:10.3929/ethz-a-006492339 · Cited by 5
Compact Soft X-Ray Microscopy : Sources, Optics and Instrumentation
Takman, P. A. C. (2007) · KTH Publication Database DiVA (KTH Royal Institute of Technology) · Cited by 4
A Crossed Laser Phase Plate for CryoEMPreprint
Yu, Y. E., Cheng, A., Montabana, E. A., Soldán, N. P., Cooper, E. S., Zhang, J. T., Axelrod, J. J., Petrov, P. N., Torkaman, A., Roof, D., et al. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.06.05.730245 · Cited by 3
Phase Contrast Alignment for All Polymer Optical Interconnect Devices
Ge, T., Yang, J., & Takashima, Y. (2014) · Frontiers in Optics · doi:10.1364/fio.2014.fw5a.4 · Cited by 2
Jiaqi, 姜. J., Xiu, 姚. Y., Chunyu, 李. L., Bo, 赵. Z., Baosen, 史. S., & Zhihan, 朱. Z. (2024) · Acta Optica Sinica · doi:10.3788/aos231646 · Cited by 2
Ultracompact Achromatic Spiral Phase Contrast Imager on a CMOS Chip
Wang, X., Wang, C., Ni, J., Liu, S., Wu, H., Tao, Y., Jin, Y., Wang, X., Li, J., Hu, Y., et al. (2025) · Laser & Photonics Review · doi:10.1002/lpor.202500239 · Cited by 3
Valentino, M., D’Agostino, M., Licitra, F., Pirone, D., Vitale, F., Micco, A. D., Pavone, L. M., Miccio, L., Bianco, V., & Ferraro, P. (2025) · Biomedical Optics Express · doi:10.1364/boe.566028 · Cited by 2
Optical diffraction tomographic microscopy: a cutting-edge label-free three-dimensional bioimaging
Min, J., Gao, P., Yuan, X. F., Xue, Y., Liu, R., Feng, Y., Wang, S., Li, Y. J., Wen, K., Yang, L., et al. (2025) · Biophysics Reports · doi:10.52601/bpr.2025.250026 · Cited by 2
“In both PCM and DICM, the image is formed by a complex interaction of the incoherent illuminating light with the specimen.”
Rogalski, M., Zdańkowski, P., Heto, M., Mierzejewska, J., Lenarcik, M., Li, Z., Sun, J., Zuo, C., & Trusiak, M. (2025) · Journal of Physics Photonics · doi:10.1088/2515-7647/ae236c · Cited by 2
“Quantitative phase imaging (QPI), that synergizes phase contrast [1] and holography [2] principles, has revolutionized label-free microscopy by mapping optical path–length variations, which directly correspond to physical thickness profile and refractive-index (RI) characteristics of transparent…”
Pirone, D., di Summa, M., Mosca, N., Giugliano, G., Schiavo, M., Agostino, M. D., Medina, D. L., Bianco, V., Miccio, L., Memmolo, P., et al. (2025) · Journal of Physics Photonics · doi:10.1088/2515-7647/ae2f86 · Cited by 2
“Given these limitations, phase-contrast microscopy (PCM) has been established as an alternative imaging technique for studying single live cells without the need for exogenous staining [4].”
Directional dark field for nanoscale full-field transmission X-ray microscopy
Wirtensohn, S., Flenner, S., John, D., Qi, P., Dávid, C., May, M., Huber, P., Herzog, D., Tangl, S., Kampleitner, C., et al. (2026) · Light Science & Applications · doi:10.1038/s41377-026-02263-z · Cited by 2
“However, the limitations of attenuation-based X-ray imaging in detecting subtle sample features have driven the development of complementary imaging modalities such as phase-contrast imaging, which exploits the refractive properties of a sample to enhance image contrast [12–16].”
Tahara, T. (2026) · Journal of Physics Photonics · doi:10.1088/2515-7647/ae5382 · Cited by 2
Miccio, L., Grilli, S., Paturzo, M., Fińizio, A., Caprio, G. D., Coppola, G., Ferraro, P., Puglisi, R., Balduzzi, D., & Galli, A. (2010) · Springer series in surface sciences · doi:10.1007/978-3-642-15813-1_3 · Cited by 2
Pozzi, G. (2016) · Advances in imaging and electron physics · doi:10.1016/bs.aiep.2016.02.007 · Cited by 2
Implementation of a Raspberry-Pi-based LED array microscope for multi-contrast images
Watanabe, W., Maruyama, R., Shimada, T., Yokoe, R., & Arimoto, H. (2018) · Biomedical Imaging and Sensing Conference (BISC) · doi:10.1117/12.2319076 · Cited by 2
“Various transmitted light-based techniques including phase contrast, dark field, polarization and differential interference contrast are used [3-10].”
MethodAn iterative compensation solution to the transport-of-intensity equation
Zhang, J., Chen, Q., Sun, J., Tian, L., & Zuo, C. (2020) · Advanced Optical Imaging Technologies · doi:10.1117/12.2573960 · Cited by 2
Obermair, M., Hettler, S., Dries, M., Hugenschmidt, M., Spiecker, R., & Gerthsen, D. (2022) · Journal of Microscopy · doi:10.1111/jmi.13108 · Cited by 2
Shao, M., Wang, K., Wang, Z., Peng, T., Zhang, S., Zhang, J., Fang, S., Wang, F., Zhang, S., Zhong, M., et al. (2022) · Journal of Biophotonics · doi:10.1002/jbio.202200122 · Cited by 2
Application and progress of highcontent imaging in molecular biology
Boyang, H., Yangyanqiu, W., Wenting, R., Chenxin, Y., Chu, J., Zhanbo, Q., Yanjun, Y., Qiang, Y., & Han, S. (2023) · Biotechnology Journal · doi:10.1002/biot.202300170 · Cited by 2
Tiwari, S., Tayal, S., Trivedi, S., Kaur, H., & Mehta, D. S. (2024) · Journal of Biophotonics · doi:10.1002/jbio.202300499 · Cited by 2
Metadata
- Authors
- Zernike, F.
- Corresponding author
- Zernike, F.
- Venue
- Physica
- Publisher
- Elsevier BV
- Published
- 1942-07
- Volume
- 9
- Issue
- 7
- Pages
- 686-698
- ISSN
- 0031-8914 (ISSN-L)
- OpenAlex
- W1980774072
- Semantic Scholar
- e3d798588553ec88195a4ec61df3f175d9094154
- Cited by
- 1,068
- References
- 8
- Citations by year
- 2026: 58 · 2025: 48 · 2024: 41 · 2023: 33 · 2022: 52 · 2021: 58 · 2020: 50 · 2019: 89 · 2018: 62 · 2017: 56 · 2016: 46 · 2015: 56 · 2014: 43 · 2013: 19 · 2012: 34
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Physica (publishedVersion)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Digital Holography and Microscopy
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Optical measurement and interference techniques
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced optical system design
- Keywords
- phase contrast microscopy, phase gratings, transparent objects, diffraction theory, schlieren method, refractive index difference, diffraction halo
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.