Phase contrast, a new method for the microscopic observation of transparent objects
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Different symbols correspond to distinct RI changes that can be read using Zernike phase-contrast microscopy33 (Extended Data Fig. 3; see section ‘Phase read’).”
From Laser writing in glass for dense, fast and efficient archival data storage (2026) · cites this paper as [33]
Citations
Cites
XV. On the theory of optical images, with special reference to the microscope
Rayleigh (1896) · The London Edinburgh and Dublin Philosophical Magazine and Journal of Science · doi:10.1080/14786449608620902 · Cited by 386
Diffraction Theory of the Knife-Edge Test and its Improved Form, The Phase-Contrast Method
Zernike, F., & Stratton, F. J. M. (1934) · Monthly Notices of the Royal Astronomical Society · doi:10.1093/mnras/94.5.377 · Cited by 383
Self-citationDie Darstellung von Chromosomen mittels des Phasenkontrastverfahrens
Michel, K. (1941) · Die Naturwissenschaften · doi:10.1007/bf01476461 · Cited by 28
Optische Studien nach der Methode der Schlierenbeobachtung
Töpler, A. (1867) · Annalen der Physik · doi:10.1002/andp.18672070603 · Cited by 26
Das Phasenkontrastverfahren Nach Zernike als Biologisches Forschungs-Mittel
Loos, W. (1941) · Journal of Molecular Medicine · doi:10.1007/bf02327345 · Cited by 19
The Spierer Lens and what it reveals in Cellulose and Protoplasm
Seijriz, W. (1931) · The Journal of Physical Chemistry · doi:10.1021/j150319a010 · Cited by 10
Spierer Lens and Colloidal Structure
Seifriz, W. (1936) · Industrial & Engineering Chemistry · doi:10.1021/ie50313a034 · Cited by 9
Microscopy of Starch by the Spiere Lens
Woodruff, S. (1938) · Industrial & Engineering Chemistry · doi:10.1021/ie50348a013 · Cited by 4
Research works printed but not linked: 5
- F. Zernike, Ned. T. Natuurk. (in the press).
- Abbe, 1873, Arch. mikrosk. Anat., 9, 431
- Abbe, 1873, Ges. Abband. I, 45, 273
- Spierer, 1926, Arch. sc. phys. nat., 8, 121
- Zernike, 1937, Physik. Z., 38, 994
Cited by
Items 401–500 of 1,000
One-Shot Phase Image Distinction of Plasmonic and Dielectric Nanoparticles
Saemisch, L., van Hulst, N. F., & Liebel, M. (2021) · Nano Letters · doi:10.1021/acs.nanolett.1c00866 · Cited by 13
Optical spatial filtering with plasmonic directional image sensors
Liu, J., Wang, H., Kogos, L. C., Li, Y., Li, Y., Tian, L., & Paiella, R. (2022) · Optics Express · doi:10.1364/oe.460556 · Cited by 14
Optical Sensing of Red Blood Cell Dynamics
Park, Y., Best-Popescu, C. A., & Popescu, G. (2011) · Springer eBooks · doi:10.1007/978-1-4419-8083-0_13 · Cited by 13
A phase-shifting Zernike wavefront sensor for the Palomar P3K adaptive optics system
Wallace, J. K., Crawford, S. L., Loya, F. M., & Moore, J. D. P. (2012) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.927041 · Cited by 13
Hettler, S., Gamm, B., Dries, M., Frindt, N., Schröder, R. R., & Gerthsen, D. (2012) · Microscopy and Microanalysis · doi:10.1017/s1431927612001560 · Cited by 13
“The unscattered electrons remain unaffected because they are transmitted through a small hole in the carbon film ~Zernike, 1942; Danev & Nagayama, 2001a!. Electrostatic PPs provide the advantage that variable phase shifts can be generated, which has entailed new applications of PP TEM.”
BackgroundLow-cost oblique illumination: an image quality assessment
Ruiz-Santaquiteria, J., Espinosa-Aranda, J. L., Déniz, Ó., Sánchez, C., Borrego‐Ramos, M., Blanco, S., Cristóbal, G., & Bueno, G. (2018) · Journal of Biomedical Optics · doi:10.1117/1.jbo.23.1.016001 · Cited by 15
Kumar, V., la Cadena, A. D., Perri, A., Preda, F., Coluccelli, N., Cerullo, G., & Polli, D. (2018) · APL Photonics · doi:10.1063/1.5034114 · Cited by 13
Lensless on-chip LED array microscope using amplitude and phase masks
Hassan, A., Khan, S. R., Rasul, K., & Hussain, A. (2020) · Journal of the Optical Society of America B · doi:10.1364/josab.396076 · Cited by 13
Spiecker, R., Dries, M., Hettler, S., Spiecker, M., Obermair, M., & Gerthsen, D. (2019) · Advanced Structural and Chemical Imaging · doi:10.1186/s40679-019-0067-z · Cited by 13
Spatial filtering in optical data-processing
Birch, K. G. (1972) · Reports on Progress in Physics · doi:10.1088/0034-4885/35/3/305 · Cited by 13
Microfluidic tools to investigate pathologies in the blood microcirculation
Preira, P., Leoni, T., Valignat, M., Lellouch, A. C., Robert, P., Forel, J. M., Papazian, L., Duménil, G., Bongrand, P., Théodoly, O., et al. (2012) · International Journal of Nanotechnology · doi:10.1504/ijnt.2012.045340 · Cited by 13
Wave reconstruction in TEM using a variable phase plate
Dyck, D. V. (2010) · Ultramicroscopy · doi:10.1016/j.ultramic.2009.12.016 · Cited by 13
Passive coherent combining of lasers with phase-contrast filtering for enhanced efficiency
Jeux, F., Desfarges‐Berthelemot, A., Kermène, V., Guillot, J., & Barthélémy, A. (2012) · Applied Physics B · doi:10.1007/s00340-012-5042-5 · Cited by 13
Laser oblique scanning optical microscopy (LOSOM) for phase relief imaging
Ding, Y., Xie, H., Peng, T., Lu, Y., Jin, D., Teng, J., Ren, Q., & Xi, P. (2012) · Optics Express · doi:10.1364/oe.20.014100 · Cited by 12
Quantum imaging of a polarisation sensitive phase pattern with hyper-entangled photons
Kaur, M., & Singh, M. (2021) · Scientific Reports · doi:10.1038/s41598-021-02650-z · Cited by 13
Paganin, D. M., Sales, M., Kadletz, P. M., Kockelmann, W. A., Beltran, M. A., Poulsen, H. F., & Schmidt, S. (2023) · Physical Review Applied · doi:10.1103/physrevapplied.19.034005 · Cited by 12
Transport of intensity and phase: applications to digital holography [Invited]
Alanazi, N. A., Scott, A. M., Al-Ghezi, H., Faryad, M., Lakhtakia, A., & Banerjee, P. P. (2024) · Applied Optics · doi:10.1364/ao.519170 · Cited by 13
Carl, S., Will, J., Madubuko, N., Götz, A., Przybilla, T., Wu, M., Raman, N., Wirth, J., Taccardi, N., Zubiri, B. A., et al. (2024) · The Journal of Physical Chemistry Letters · doi:10.1021/acs.jpclett.3c03494 · Cited by 12
Phillips, K. G., Baker-Groberg, S. M., & McCarty, O. J. T. (2014) · Journal of Visualized Experiments · doi:10.3791/50988-v · Cited by 12
Quantitative phase retrieval in transmission hard x-ray microscope
Yin, G.-C., Chen, F., Hwu, Y., Shieh, H. D., & Liang, K. S. (2007) · Applied Physics Letters · doi:10.1063/1.2724066 · Cited by 12
Image Plane Holographic Microscopy With a Table-Top Soft X-Ray Laser
Nejdl, J., Howlett, I. D., Carlton, D., Anderson, E. H., Chao, W. L., Marconi, M. C., Rocca, J. J. G., & Menoni, C. S. (2015) · IEEE photonics journal · doi:10.1109/jphot.2015.2389957 · Cited by 12
Wang, Y., Lü, X., Liu, Y., Tian, J., & Zhong, L. (2017) · Optics Express · doi:10.1364/oe.25.029971 · Cited by 12
Quenched Stochastic Optical Reconstruction Microscopy (qSTORM) with Graphene Oxide
Li, R., Georgiades, P., Cox, H., Phanphak, S., Roberts, I. S., Waigh, T. A., & Lu, J. R. (2018) · Scientific Reports · doi:10.1038/s41598-018-35297-4 · Cited by 12
Quantifying Intracellular Particle Flows by DIC Object Tracking
Chaphalkar, A. R., Jawale, Y. K., Khatri, D., & Athale, C. A. (2021) · Biophysical Journal · doi:10.1016/j.bpj.2020.12.013 · Cited by 12
“In particular, differential interference contrast (DIC) or Nomarski (1) and phase-contrast microscopy (2) are standard modes built into biological microscopes to generate image contrast using inherent features”
BackgroundJohnson, H. M., & Parsons, D. F. (1970) · Journal of Microscopy · doi:10.1111/j.1365-2818.1970.tb02220.x · Cited by 12
Phase contrast flow visualization
Anderson, R. C., & Taylor, M. W. (1982) · Applied Optics · doi:10.1364/ao.21.000528 · Cited by 12
Nanoscale dark-field imaging in full-field transmission X-ray microscopy
Wirtensohn, S., Qi, P., Dávid, C., Herzen, J., Greving, I., & Flenner, S. (2024) · Optica · doi:10.1364/optica.524812 · Cited by 11
“This can be implemented at a TXM setup by Zernike phase-contrast [5–9].”
MethodHard x-ray nanotomography at the P05 imaging beamline at PETRA III
Flenner, S., Hagemann, J., Storm, M., Kubec, A., Qi, P., Dávid, C., Longo, E., Niese, S., Gawlitza, P., Zeller‐Plumhoff, B., et al. (2022) · Developments in X-Ray Tomography · doi:10.1117/12.2632706 · Cited by 11
Single-pixel dual-mode microscopy for simultaneous acquisition of magnitude and wrapped phase images
Zhao, Y.-N., Wang, L., Li, H., Liu, C., Guan, L., Cao, D.-Z., Liu, H., & Zhang, S.-H. (2024) · Optics & Laser Technology · doi:10.1016/j.optlastec.2024.112017 · Cited by 11
Ibáñez, F. V., & Verbeeck, J. (2025) · Microscopy and Microanalysis · doi:10.1093/mam/ozae125 · Cited by 11
“In Zernike Phase Contrast [53, 54], a phase plate is placed in the back focal plane of the objective aperture, which shifts only the low-frequency component of the wave by π/ 2.”
A quantitative computer simulation of microscopic imaging
Goldstein, D. J. (1991) · Journal of Microscopy · doi:10.1111/j.1365-2818.1991.tb03134.x · Cited by 11
“The visibility may be somewhat improved by almost any manipulation of the image-forming process, for example by throwing the specimen slightly out of focus (Zernike, 1942), but phase contrast (Zernike, 1934, 1955) is a more effective and specific way to visualize transparent specimens.”
BackgroundResultSelf-Bayesian aberration removal via constraints for ultracold atom microscopy
Altuntaş, E., & Spielman, I. B. (2021) · Physical Review Research · doi:10.1103/physrevresearch.3.043087 · Cited by 11
“In 1932, Frits Zernike invented PCI as a phase-sensitive imaging method utilizing the nonuniform refractive index of an object to reveal features that are invisible in other imaging techniques [23,24].”
MethodSeo, K. W., Seo, E., & Lee, S. J. (2014) · Journal of Visualization · doi:10.1007/s12650-014-0200-y · Cited by 11
“Therefore, evaluating the spatial and temporal variations in morphological structures and physical properties of a sample is almost impossible using only PCM and DIC microscopy.”
MethodInfluentialThe benefits of applied research: 37 years of discoveries, adaptations and solutions
Borges, E. P., Lopes, M. L., Bernardino, C. D., Godoy, A., Ré, F. E., Cherubin, R. A., Paulillo, S. C. D. L., & de Amorim, H. V. (2015) · Sugar Industry · doi:10.36961/si16360 · Cited by 11
From Animaculum to Single Molecules: 300 Years of the Light Microscope
Wollman, A. J. M., Nudd, R., Hedlund, E., & Leake, M. C. (2023) · doi:10.1201/9781003298038-53 · Cited by 12
Ayoub, A. B., Pham, T.-A., Lim, J., Unser, M. A., & Psaltis, D. (2019) · Optics Communications · doi:10.1016/j.optcom.2019.124486 · Cited by 11
Single-particle cryo-EM: alternative schemes to improve dose efficiency
Zhang, Y., Lu, P., Rotunno, E., Troiani, F., van Schayck, J. P., Tavabi, A. H., Dunin‐Borkowski, R. E., Grillo, V., Peters, P. J., & Ravelli, R. B. G. (2021) · Journal of Synchrotron Radiation · doi:10.1107/s1600577521007931 · Cited by 11
“…Zernike phase plates were proposed and used to increase the phase contrast for weak phase objects by adding a /2 phase shift to the diffracted beam (Zernike, 1942), altering the CTF into CTF ¼ sin 2 1 4 Cs 4q4 1 2 f 2q2 þ 2 ¼ cos 2 1 4 Cs 4q4 1 2 f 2q2 : ð5Þ As the contrast of images is dominated…”
Method(2009) · Springer series in optical sciences/SPringer series in optical sciences · doi:10.1007/978-90-481-2839-6_2 · Cited by 11
Arieli, Y. S. (2000) · Optics Communications · doi:10.1016/s0030-4018(00)00720-3 · Cited by 11
Recognition and classification of three-dimensional phase objects by digital Fresnel holography
Nelleri, A., Joseph, J., & Singh, K. (2006) · Applied Optics · doi:10.1364/ao.45.004046 · Cited by 11
Phase contrast imaging: a generalized perspective
Teschke, M., & Sinzinger, S. (2009) · Journal of the Optical Society of America A · doi:10.1364/josaa.26.001015 · Cited by 11
Phase contrast and DIC illumination for AFM hybrids
Lugmaier, R. A., Hugel, T., Benoit, M., & Gaub, H. E. (2005) · Ultramicroscopy · doi:10.1016/j.ultramic.2005.04.008 · Cited by 11
Goldstein, D. J. (1982) · Journal of Microscopy · doi:10.1111/j.1365-2818.1982.tb00435.x · Cited by 11
Martz, H. E., Kozioziemski, B. J., Lehman, S. K., Hau‐Riege, S. P., Schneberk, D. J., & Barty, A. (2006) · Journal of the Optical Society of America A · doi:10.1364/josaa.24.000169 · Cited by 11
The phase problem in electron microscopy
Misell, D. L. (2023) · Advances in imaging and electron physics · doi:10.1016/bs.aiep.2022.12.004 · Cited by 11
Gradient optical diffraction tomography
Winnik, J., Zdańkowski, P., Stefaniuk, M., Ahmad, A., Zuo, C., Ahluwalia, B. S., & Trusiak, M. (2025) · Communications Physics · doi:10.1038/s42005-025-02416-3 · Cited by 10
“Quantitative phase imaging (QPI) 3,4 , building on its qualitative predecessors — Zernike phase contrast 5 and Nomarski differential interference contrast (DIC) microscopy 6 — enables characterization of transparent objects by measuring the optical phase delay they introduce.”
Detective Quantum Efficiency-Based Comparison of HRTEM and Ptychography Phase Imaging
Bennemann, F., Kirkland, A. I., Muller, D. A., & Nellist, P. D. (2026) · Microscopy and Microanalysis · doi:10.1093/mam/ozag018 · Cited by 10
“In the spatial frequency domain this results in An ideal Zernike phase plate introduces a phase shift of π/ 2 for all spatial frequencies except for the direct beam[Zernike, 1942].”
Dual-modality endomicroscopy with co-registered fluorescence and phase contrast
Ba, C., Palmiere, M., Ritt, J. T., & Mertz, J. C. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.003403 · Cited by 10
Application of quantitative cell imaging using label-free optical diffraction tomography
Pack, C. (2021) · Biophysics and Physicobiology · doi:10.2142/biophysico.bppb-v18.027 · Cited by 10
“On the other hand, the conventional phase-contrast microscope developed by Frits Zernike allows the observation of transparent cells without staining [7].”
Hard X-ray full-field nanoimaging using a direct photon-counting detector
Flenner, S., Hagemann, J., Wittwer, F., Longo, E., Kubec, A., Rothkirch, A., Dávid, C., Müller, M., & Greving, I. (2022) · Journal of Synchrotron Radiation · doi:10.1107/s1600577522012103 · Cited by 10
O'Brien, C. T., Li, Z., Liu, M., Innes, J. R., Li, S., Papageorgiou, D. G., Storm, M., Burnett, T. L., & Young, R. J. (2024) · Composites Part A Applied Science and Manufacturing · doi:10.1016/j.compositesa.2024.108269 · Cited by 10
“Due to the fact that the images were captured using Zernike phase contrast [21], the bright white flares on the image can be attributed to the dramatic change in refractive index of the neighbouring components (GNPs and voids) in the nanocomposite.”
BackgroundHattori, R., Oku, O., Sugie, R., Murakami, K., & Kuzuhara, M. (2018) · Applied Physics Express · doi:10.7567/apex.11.075501 · Cited by 10
Lumbres, J., Males, J. R., Douglas, E. S., Close, L. M., Cahoy, K., Carlton, A. K., Clark, J. R., Doelman, D. S., Feinberg, L. D., Guyon, O., et al. (2018) · Adaptive Optics Systems VI · doi:10.1117/12.2313780 · Cited by 10
Adaptive illumination for optimal image quality in phase contrast microscopy
Hofmeister, A., Thalhammer, G., Ritsch‐Marte, M., & Jesacher, A. (2019) · Optics Communications · doi:10.1016/j.optcom.2019.124972 · Cited by 10
Wavelength-tunable spiral-phase-contrast imaging
Lee, D., Lee, S., Yeo, W.-J., Jeong, S. K., Jeon, M., Choi, H., Kim, H. S., Bae, J. Y., Kim, D. U., Hur, H., et al. (2022) · Optics Express · doi:10.1364/oe.461660 · Cited by 10
Determination of the complex refractive index of cell cultures by reflectance spectrometry
Călin, M. A., Calin, M. R., & Munteanu, C. (2014) · The European Physical Journal Plus · doi:10.1140/epjp/i2014-14116-1 · Cited by 10
Fredenberg, E., Danielsson, M. E., Stayman, J. W., Siewerdsen, J. H., & Åslund, M. (2012) · Medical Physics · doi:10.1118/1.4739195 · Cited by 12
Iijima, Y., & Kudo, N. (2017) · Japanese Journal of Applied Physics · doi:10.7567/jjap.56.07jf13 · Cited by 10
Contrast enhancement by oblique illumination microscopy with an LED array
Sugimoto, R., Maruyama, R., Tamada, Y., Arimoto, H., & Watanabe, W. (2019) · Optik · doi:10.1016/j.ijleo.2019.02.068 · Cited by 10
Automated sensing and splitting of stem cell colonies on microraft arrays
DiSalvo, M., Smiddy, N. M., & Allbritton, N. L. (2019) · APL Bioengineering · doi:10.1063/1.5113719 · Cited by 10
Experimental Investigation of the Settling Characteristics of Carbon and Metal Oxide Nanofuels
Singh, G., Lopes, E., Hentges, N., Becker, D., & Ratner, A. (2019) · Journal of Nanofluids · doi:10.1166/jon.2019.1715 · Cited by 10
“opy is a technique that relies on the phase shift in light traveling through a transparent sample, by correlating this phase shift with brightness change to obtain a magnified picture of the specimen [27]. It can be used to study the agglomeration behavior of nanofluids [25]. One of its drawbacks is that the base flui…”
BackgroundMaximum likelihood estimation in the context of an optical measurement
Vella, A., & Alonso, M. A. (2020) · Progress in optics · doi:10.1016/bs.po.2019.11.007 · Cited by 13
“For example, in phase contrast microscopy [44, 45] where the measured parameter p1 corresponds to the optical thickness of a sample at a given point, the weak value is made imaginary”
BackgroundComplex-amplitude Fourier single-pixel imaging via coherent structured illumination
Hou, H.-Y., Zhao, Y., Han, J., Cao, D.-Z., Zhang, S.-H., Liu, H., & Liang, B. L. (2022) · Chinese Physics B · doi:10.1088/1674-1056/ac8e9a · Cited by 10
Schilling, T., Mirosław, Ł., Głąb, G., & Smereka, M. (2007) · International Journal of Gynecological Cancer · doi:10.1111/j.1525-1438.2007.00828.x · Cited by 10
Tomographic phase microscopy and its biological applications
Choi, W. (2012) · 3D Research · doi:10.1007/3dres.04(2012)5 · Cited by 10
Piper, J. (2011) · Diatom Research · doi:10.1080/0269249x.2011.587377 · Cited by 10
“The principles, advantages and limitations of standard phase contrast have been described and discussed by several authors (Zernike 1942a, b, Robertson 1970, Staghter & Staghter 1992, Glückstadt et al. 2001, Murphy 2001, Abramowitz 2006, Murphy 2006, Nobel Foundation 2010).”
BackgroundPhase contrast imaging system for TEXT-U
Chatterjee, R., Hallock, G. A., & Gartman, M. L. (1995) · Review of Scientific Instruments · doi:10.1063/1.1146380 · Cited by 10
An Extension of Toraldo’s Theory of Phase Contrast I*
Epstein, L. I. (1950) · Journal of the Optical Society of America · doi:10.1364/josa.40.000291 · Cited by 10
Optical scintillation: a survey of the literature
Meyer‐Arendt, J. R. (1965) · doi:10.6028/nbs.tn.225 · Cited by 10
Practical application of microsphere samples for benchmarking a quantitative phase imaging system
Kwee, E., Peterson, A., Halter, M., & Elliott, J. (2021) · Cytometry Part A · doi:10.1002/cyto.a.24291 · Cited by 9
“Zernike phase contrast, which converts the phase change that is induced as light passes through cells to intensities visualized through a microscope, has been one of the more effective ways to visualize live unstained cells [1].”
BackgroundSpeckle tracking phase-contrast computed tomography at an inverse Compton X-ray source
Zandarco, S., Günther, B. S., Riedel, M., Breitenhuber, G., Kirst, M., Achterhold, K., Pfeiffer, F., & Herzen, J. (2024) · Optics Express · doi:10.1364/oe.528701 · Cited by 9
Characterization of Komagataeibacter xylinus by a polarization modulation imaging method
Liu, W., Xiong, J., Zhang, H., Liu, X., Liu, G., & Zhao, H. (2019) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/ab6519 · Cited by 9
Quantitative phase gradient microscopy with spatially entangled photons
Zhang, Y., Moreau, P., England, D. G., Karimi, E., & Sussman, B. (2026) · Nature Communications · doi:10.1038/s41467-026-69881-4 · Cited by 9
“We present an entanglement-based quantitative phase gradient microscopy technique that employs principles from quantum ghost imaging and ghost diffraction.”
Off-axis digital lensless holographic microscopy based on spatially multiplexed interferometry
Picazo-Bueno, J. Á., Ketelhut, S., Schnekenburger, J., Micó, V., & Kemper, B. (2024) · Journal of Biomedical Optics · doi:10.1117/1.jbo.29.s2.s22715 · Cited by 9
Metasurfaces for Infrared Multimodal Microscopy: Phase Contrast and Bright Field
Sulejman, S. B., Wesemann, L., McCormack, M., Meng, J., Hutchison, J. A., Priscilla, N., McColl, G., Read, K., Sim, W., Sukhorukov, A. A., et al. (2025) · ACS Photonics · doi:10.1021/acsphotonics.4c02097 · Cited by 10
Kishimoto, H., Shinohara, Y., Naito, M., Takeuchi, A., Uesugi, K., Suzuki, Y., & Amemiya, Y. (2012) · Polymer Journal · doi:10.1038/pj.2012.201 · Cited by 9
Polarization-based non-staining cell detection
Zhang, M., Ihida‐Stansbury, K., der Spiegel, J. V., & Engheta, N. (2012) · Optics Express · doi:10.1364/oe.20.025378 · Cited by 9
Experimental Investigation of Water Emulsion Fuel Stability
Singh, G., Lopes, E., Hentges, N., & Ratner, A. (2019) · ASME International Mechanical Engineering Congress and Exposition (IMECE) · doi:10.1115/imece2019-10258 · Cited by 9
“Since both soy biodiesel (SBD) and water are optically transparent, a phase-contrast microscope [11] is also an appropriate tool for analyzing the size distribution of the dispersed phase in an emulsion.”
A Novel Method for Effective Cell Segmentation and Tracking in Phase Contrast Microscopic Images
Jo, H., Han, J., Kim, Y. S., Lee, Y., & Yang, S. (2021) · Sensors · doi:10.3390/s21103516 · Cited by 10
“Thin, transparent areas, such as the pseudopodium, can be observed more clearly [18].”
BackgroundMultimodal image reconstruction from tomographic diffraction microscopy data
Abbessi, R., Verrier, N., Taddese, A. M., Laroche, S., Debailleul, M., Lo, M., Courbot, J., & Haeberlé, O. (2022) · Journal of Microscopy · doi:10.1111/jmi.13131 · Cited by 11
Quantitative Phase‐Digital Holographic Microscopy: A New Modality for Live Cell Imaging
Marquet, P. P., Rappaz, B., & Pavillon, N. (2015) · Wiley eBooks · doi:10.1002/9781119091745.ch5 · Cited by 9
Coherent diffraction imaging of non-isolated object with apodized illumination
Khakurel, K. P., Kimura, T., Joti, Y., Matsuyama, S., Yamauchi, K., & Nishino, Y. (2015) · Optics Express · doi:10.1364/oe.23.028182 · Cited by 9
Phase retrieval from image intensities: Why does exit wave restoration using IWFR work so well?
Ishizuka, K. (2013) · Microscopy · doi:10.1093/jmicro/dft005 · Cited by 9
Poola, P. K., Jayaraman, V. U., Chaithanya, K., Rao, D. G., & John, R. (2018) · OSA Continuum · doi:10.1364/osac.1.001215 · Cited by 9
Fourier Plane Filtering Revisited - Analogies in Optics and Mathematics
Heise, B., Reinhardt, M., Schausberger, S. E., Häuser, S., Bernstein, S., & Stifter, D. (2014) · Sampling Theory in Signal and Image Processing · doi:10.1007/bf03549581 · Cited by 10
Spiral Phase Contrast Microscopy
Maurer, C., Bernet, S., & Ritsch‐Marte, M. (2011) · Wiley eBooks · doi:10.1002/9783527635368.ch8 · Cited by 9
van Duinen, G., van Heel, M., & Patwardhan, A. (2005) · Optics Express · doi:10.1364/opex.13.009085 · Cited by 9
A Review -Observations of Turbulence and Structure in Magnetized Plasmas
Fujisawa, A. (2010) · Plasma and Fusion Research · doi:10.1585/pfr.5.046 · Cited by 9
Tolansky, S. (1967) · Biographical Memoirs of Fellows of the Royal Society · doi:10.1098/rsbm.1967.0021 · Cited by 9
Phase Contrast and Interference Microscopy in Cytology
Barer, R. (1966) · Elsevier eBooks · doi:10.1016/b978-1-4832-3046-7.50007-9 · Cited by 9
Chen, K.-F., Chang, C.-S., Shiue, J., Hwu, Y., Chang, W., Kai, J., & Chen, F. (2007) · Micron · doi:10.1016/j.micron.2007.10.021 · Cited by 9
A coherence approach to phase-contrast microscopy: Theory
Nugent, K. A., Arhatari, B. D., & Peele, A. G. (2008) · Ultramicroscopy · doi:10.1016/j.ultramic.2008.03.008 · Cited by 9
Kam, Z. (1987) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583500004182 · Cited by 10
Phase contrast electron microscopy of amorphous specimens supported on thin crystals
Hines, R. L., & Howie, A. (1975) · Philosophical magazine · doi:10.1080/14786437508219952 · Cited by 9
Advances in phase plate cryo-EM imaging of DNA and nucleosomes
Chua, E. Y. D., & Sandin, S. (2017) · Nucleus · doi:10.1080/19491034.2017.1287643 · Cited by 8
“By introducing a 90 phase shift between the direct and diffracted light, Zernike’s phase contrast microscope enabled scientists to image live cells and their internal structures with enhanced contrast without the need for cytotoxic stains.(2) The idea to use phase plates in transmission electron microscopy was first p…”
BackgroundAdaptive phase contrast microscopy to compensate for the meniscus effect
Nienhaus, F., Piotrowski, T., Nießing, B., König, N., & Schmitt, R. H. (2023) · Scientific Reports · doi:10.1038/s41598-023-32917-6 · Cited by 8
Laser Light-field Fusion for Wide-field Lensfree On-chip Phase Contrast Microscopy of Nanoparticles
Kazemzadeh, F., & Wong, A. K. C. (2016) · Scientific Reports · doi:10.1038/srep38981 · Cited by 8
“1038/srep38981 ∫ λ = λ λ q v f d , (1) x y z x y z , , , , ,”
Full-field cavity enhanced microscopy techniques
Nimmrichter, S., Chen, C.-F., Klopfer, B. B., Kasevich, M. A., & Juffmann, T. (2018) · Journal of Physics Photonics · doi:10.1088/2515-7647/aae228 · Cited by 11
Comparative image simulations for phase-plate transmission electron microscopy
Hettler, S., & Arenal, R. (2021) · Ultramicroscopy · doi:10.1016/j.ultramic.2021.113319 · Cited by 8
Thin film notch filters as platforms for biological image processing
Sulejman, S. B., Priscilla, N., Wesemann, L., Lee, W. S. L., Lou, J., Hinde, E., Davis, T. J., & Roberts, A. (2023) · Scientific Reports · doi:10.1038/s41598-023-31528-5 · Cited by 8
Metadata
- Authors
- Zernike, F.
- Corresponding author
- Zernike, F.
- Venue
- Physica
- Publisher
- Elsevier BV
- Published
- 1942-07
- Volume
- 9
- Issue
- 7
- Pages
- 686-698
- ISSN
- 0031-8914 (ISSN-L)
- OpenAlex
- W1980774072
- Semantic Scholar
- e3d798588553ec88195a4ec61df3f175d9094154
- Cited by
- 1,068
- References
- 8
- Citations by year
- 2026: 58 · 2025: 48 · 2024: 41 · 2023: 33 · 2022: 52 · 2021: 58 · 2020: 50 · 2019: 89 · 2018: 62 · 2017: 56 · 2016: 46 · 2015: 56 · 2014: 43 · 2013: 19 · 2012: 34
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Physica (publishedVersion)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Digital Holography and Microscopy
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Optical measurement and interference techniques
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced optical system design
- Keywords
- phase contrast microscopy, phase gratings, transparent objects, diffraction theory, schlieren method, refractive index difference, diffraction halo
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.