Indoor air microbiological evaluation of offices, hospitals, industries, and shopping centers
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
In this study it was compared the MAS-100 and the Andersen air samplers' performances and a similar trend in both instruments was observed. It was also evaluated the microbial contamination levels in 3060 samples of offices, hospitals, industries, and shopping centers, in the period of 1998 to 2002, in Rio de Janeiro city. Considering each environment, 94.3 to 99.4% of the samples were the allowed limit in Brazil (750 CFU/m3). The industries' results showed more important similarity among fungi and total heterotrophs distributions, with the majority of the results between zero and 100 CFU/m3. The offices' results showed dispersion around 300 CFU/m3. The hospitals' results presented the same trend, with an average of 200 CFU/m3. Shopping centers' environments showed an average of 300 CFU/m3 for fungi, but presented a larger dispersion pattern for the total heterotrophs, with the highest average (1000 CFU/m3). It was also investigated the correlation of the sampling period with the number of airborne microorganisms and with the environmental parameters (temperature and air humidity) through the principal components analysis. All indoor air samples distributions were very similar. The temperature and air humidity had no significant influence on the samples dispersion patterns.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Indoor and outdoor air quality investigation at schools in Hong Kong
Lee, S. C., & Chang, M. (2000) · Chemosphere · doi:10.1016/s0045-6535(99)00396-3 · Cited by 356
Cellular and Molecular Basis of the Asbestos-related Diseases
Rom, W. N., Travis, W. D., & Brody, A. R. (1991) · American Review of Respiratory Disease · doi:10.1164/ajrccm/143.2.408 · Cited by 252
Significance of air humidity and air velocity for fungal spore release into the air
Pasanen, A.-L., Pasanen, P., Jantunen, M. J., & Kalliokoski, P. (1991) · Atmospheric Environment. Part A. General Topics · doi:10.1016/0960-1686(91)90316-y · Cited by 191 · cited 1×
“The PCA results, showing little importance of temperature and humidity in relation to the microorganisms counts is disagreement with the works of Kethley et al. (1957) and Pasanen et al. (1991) , that related environmental parameters, such as the temperature and the air humidity as important factors for the developmen…”
ResultTake-off of Mould Spores in Relation to Wind Speed and Humidity
ZOBERI, M. H. (1961) · Annals of Botany · doi:10.1093/oxfordjournals.aob.a083732 · Cited by 49
Cited by
Solomon, F. B., Wadilo, F. W., Arota, A. A., & Abraham, Y. L. (2017) · Annals of Clinical Microbiology and Antimicrobials · doi:10.1186/s12941-017-0204-2 · Cited by 86
“Operation theatre, delivery room, and intensive care unit are settings where patients are at a greater risk than the outside environment and could be polluted with bacterial pathogens released into it from various sources [6].”
Genet, C., Kibru, G., & Tsegaye, W. (2011) · Ethiopian Journal of Health Sciences · doi:10.4314/ejhs.v21i1.69039 · Cited by 40
Y, V., & S, U. (2019) · Journal of Pure and Applied Microbiology · doi:10.22207/jpam.13.1.25 · Cited by 6
Metadata
- Authors
- Nunes, Z. G., Martins, A. S., Altoe, A. L. F., Nishikawa, M. M., Leite, M. O., Aguiar, P. F., & Fracalanzza, S. E. L.
- Venue
- Memórias do Instituto Oswaldo Cruz
- Publisher
- FapUNIFESP (SciELO)
- Published
- 2005-07
- Volume
- 100
- Issue
- 4
- Pages
- 351-357
- ISSN
- 0074-0276 (ISSN-L)
- OpenAlex
- W2096738423
- Cited by
- 55
- References
- 4
- FWCI
- 0.94
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Indoor air microbiological evaluation of offices, hospitals, industries, and shopping centers. https://app.cochat.ai/papers/10.1590/s0074-02762005000400003
- The paper
- Nunes, Z. G., Martins, A. S., Altoe, A. L. F., Nishikawa, M. M., Leite, M. O., Aguiar, P. F., & Fracalanzza, S. E. L. (2005). Indoor air microbiological evaluation of offices, hospitals, industries, and shopping centers. Memórias do Instituto Oswaldo Cruz. https://doi.org/10.1590/s0074-02762005000400003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.