Indoor air quality at restaurants with different styles of cooking in metropolitan Hong Kong
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Indoor air quality (IAQ) of a restaurant has increasingly received a lot of public concerns in Hong Kong. Unfortunately, there is limited data about the IAQ of Hong Kong restaurants. In order to characterize the current IAQ of local restaurants, four restaurants in metropolitan Hong Kong including a Korean barbecue style restaurant, a Chinese hot pot restaurant, a Chinese dim sum restaurant and a Western canteen were selected for this study. The results of this study showed that the mean concentrations of CO2 at restaurants with gas stoves for food cooking in dining areas exceeded the range from 40 to 60% indoor CO2 concentrations at restaurants without gas stoves in dining areas. The average levels of PM10 and PM2.5 at the Korean barbecue style restaurant were as high as 1442 and 1167 microg/m3, respectively. At the Korean barbecue and Chinese hot pot restaurants, the levels of PM2.5 accounted for 80-93% of their respective PM10 concentrations. The 1-h average levels of CO observed at Korean barbecue style and hot pot restaurants were 15,100 and 8000 microg/m3, respectively. Relatively high concentrations of CO2, CO, PM10, PM2.5 benzene, toluene, methylene chloride and chloroform were measured in the dining areas of the Korean barbecue style and the Chinese hot pot restaurants. The operations of pan-frying food and boiling food with soup in a hot pot could generate considerable quantities of air pollutants.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Samples collected at 10 retail shops in a large shopping center from 2002–2004 had high levels of toluene and xylene (144 and 3.5 μg/m3, respectively), but slightly lower levels of chloroform, methylene chloride, heptane and hexane (0.5, 0.8, 1.8 and 3.2 μg/m3) than the present study [56].”
From Occupational exposure and health risks of volatile organic compounds of hotel housekeepers: Field measurements of exposure and health risks (2021) · cites this paper as [56]
Citations
Cites
Ventilation for Acceptable Indoor Air Quality
Falih, M. (2019) · Cited by 2,497
Sources of fine organic aerosol. 1. Charbroilers and meat cooking operations
Rogge, W. F., Hildemann, L. M., Mazurek, M. A., Cass, G. R., & Simoneit, B. R. T. (1991) · Environmental Science & Technology · doi:10.1021/es00018a015 · Cited by 720
Baek, S.-O., Kim, Y.-S., & Perry, R. (1997) · Atmospheric Environment · doi:10.1016/s1352-2310(96)00215-4 · Cited by 298
Emissions of Carbonyl Compounds from Various Cookstoves in China
Zhang, J., & Smith, K. R. (1999) · Environmental Science & Technology · doi:10.1021/es9812406 · Cited by 182 · cited 1×
“Some studies reported that elevated formaldehyde concentrations in cooking smoke Žwere measured during cooking hours Raiyani et .al., 1993; Zhang and Kirk, 1999 .”
BackgroundMutagens From Heated Chinese and U.S. Cooking Oils
Shields, P. G., Xu, G. X., Blot, W. J., Fraumeni, J. F., Trivers, G. E., Pellizzari, E. D., Qu, Y. H., Gao, Y. T., & Harris, C. C. (1995) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/87.11.836 · Cited by 158 · cited 4×
“Shields et al., 1995 .”
BackgroundInfluentialCancer and occupation in Massachusetts: A death certificate study
Dubrow, R., & Wegman, D. H. (1984) · American Journal of Industrial Medicine · doi:10.1002/ajim.4700060305 · Cited by 133 · cited 1×
“Coggon et al., 1986; Dubrow and Wegman, 1984 .”
BackgroundCharacterization and problems of indoor pollution due to cooking stove smoke
Raiyani, C. V., Shah, S., Desai, N. M., Venkaiah, K., Patel, J. S., Parikh, D. J., & Kashyap, S. K. (1993) · Atmospheric Environment Part A General Topics · doi:10.1016/0960-1686(93)90227-p · Cited by 122
Analysis of Polycyclic Aromatic Hydrocarbons in Cooking Oil Fumes
Shu-guang, L., Dinhua, P., & Guoxiong, W. (1994) · Archives of Environmental Health An International Journal · doi:10.1080/00039896.1994.9937464 · Cited by 112 · cited 1×
“Li et al., 1994 .”
A survey of cancer and occupation in young and middle aged men. I. Cancers of the respiratory tract.
Coggon, D., Pannett, B., Osmond, C., & Acheson, E. D. (1986) · Occupational and Environmental Medicine · doi:10.1136/oem.43.5.332 · Cited by 111 · cited 1×
“Coggon et al., 1986; Dubrow and Wegman, 1984 .”
BackgroundRisk of developing lung cancer in relation to exposure to fumes from Chinese-style cooking
Zhong, L., Goldberg, M., Parent, M., & Hanley, J. (1999) · Scandinavian Journal of Work Environment & Health · doi:10.5271/sjweh.440 · Cited by 69 · cited 1×
“One possible answer to this question is that Chinese women are more exposed to cooking fumes that contain a variety of airborne carcinoŽgens Zhong et al., 1999; Benfenati et al., 1998; .”
Background
Cited by
Items 201–272 of 272
Pagel, É. C., Reis, N. C., de Alvarez, C. E., & Santos, J. M. (2017) · Ambiente Construído · doi:10.1590/s1678-86212018000100232 · Cited by 5
Zhuang, Y., Anwar, A., Li, Z., Zhang, R., Shi, F., Lin, Y., Chen, C., & Zhao, B. (2025) · Building and Environment · doi:10.1016/j.buildenv.2025.113561 · Cited by 3
Managing the invisible: the role of air quality in the hospitality industry
Zanni, S., Mura, M., & Longo, M. (2025) · International Journal of Contemporary Hospitality Management · doi:10.1108/ijchm-10-2024-1504 · Cited by 3
Zhang, D., Mui, K.-W., Gao, C., & Wong, L. T. (2026) · Energy and Buildings · doi:10.1016/j.enbuild.2026.116994 · Cited by 3
Pollutions of Cooking Oil Fume and Health Risks
Li, A., & Kosonen, R. (2019) · Springer eBooks · doi:10.1007/978-981-13-6496-9_3 · Cited by 4
An overview of indoor environmental conditions in work-from-home settings
Manu, S., & Rysanek, A. (2023) · E3S Web of Conferences · doi:10.1051/e3sconf/202339601075 · Cited by 3
Assessing PM2.5 Exposure and Contribution Rates by Cluster Microenvironments via a Time-Use Survey
Lee, S., Choe, Y., Kim, D., Shin, J., Sung, K., Kim, J., Min, G., & Yang, W. (2024) · Korean Journal of Environmental Health Sciences · doi:10.5668/jehs.2024.50.5.311 · Cited by 3
Self-citationCALIDAD DEL AIRE EN LA CAFETERÍA PRINCIPAL DE LA DIVISIÓN ACADÉMICA DE CIENCIAS BIOLÓGICAS-UJAT
Ricárdez, J. D. J. G., & Villegas, E. M. (2019) · Kuxulkab · doi:10.19136/kuxulkab.a24n50.2416 · Cited by 3
Li, H., Wang, S., Zhang, X., Yang, J., & Teng, B. (2020) · Polish Journal of Environmental Studies · doi:10.15244/pjoes/125520 · Cited by 3
“Compared with the western, Chinese cuisine tends to produce more particulate matter [27].”
BackgroundEnvironmental ergonomics: Commercial kitchens in a semi-tropical city
Gangiah, S. (2022) · doi:10.4102/aosis.2022.bk346 · Cited by 3
Yang, H.-H., Kwak, M.-J., Kim, K. J., & Kim, H.-H. (2022) · Journal of people, plants, and environment · doi:10.11628/ksppe.2022.25.6.571 · Cited by 3
Emission Characteristics of Particulate Matter from Boiling Food
Zhao, Y., Wang, M., Tao, P., Qiu, G., & Lu, X. (2023) · Atmosphere · doi:10.3390/atmos14010167 · Cited by 3
Exposure to Fumes of a Vegetable Margarine for Frying: Respiratory Effects in an Experimental Model
Cimrin, A. H., Alpaydın, A. Ö., Özbal, S., Toprak, M., Yılmaz, O., Uluorman, F., Ergür, B. U., Gürel, D., & Sofuoǧlu, S. C. (2023) · ACS Omega · doi:10.1021/acsomega.3c03340 · Cited by 4
Weidner, L., Cannas, J., Rychlik, M., & Schmitt‐Kopplin, P. (2023) · Journal of Agricultural and Food Chemistry · doi:10.1021/acs.jafc.3c05383 · Cited by 4
Iwamura, N., & Tsutsumi, K. (2024) · Cureus · doi:10.7759/cureus.64882 · Cited by 3
“…the airborne transmission rate of measles was estimated under the indoor CO 2 concentration ranged from 600 to 4,000 ppm (Figure 1 ), which could similarly be applied to settings such as class discussions, club activities, and workplace meetings. concentrations ranged from 636 to 2,344 ppm [16].”
BackgroundSu, K., Fang, X., Wu, S., Dai, X., Wang, C., Hu, L., Zhan, Y., Zhao, Y., & Xiang, J. (2024) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2024.175621 · Cited by 3
Iwamura, N., Tsutsumi, K., Hamashoji, T., Arita, Y., & Deguchi, T. (2024) · Cureus · doi:10.7759/cureus.74429 · Cited by 7
Analysis of Emissions from Selected Wood Charcoal Species Combustion
Dirner, V., Dobeš, A., & Király, A. (2014) · Applied Mechanics and Materials · doi:10.4028/www.scientific.net/amm.568-570.1645 · Cited by 3
“Despite some governments declare charcoal burning as a hazardous emissions source, relatively few studies had quantified these pollutants or addressed their potential impact on human health [6-9].”
BackgroundHalios, C. H., Assimakopoulos, M.-N., Chrisafis, D. S. S., & Santamouris, M. (2010) · International Journal of Ventilation · doi:10.1080/14733315.2010.11683859 · Cited by 3
“…of VOCs (Loh et al, 2006, Baek et al, 1996; El-Hougeiri and El Fadel, 2004), classical and photochemical pollutants such as CO, SO2, O3 and NOX (Lee et al, 1999; 2000; 2001; Baek et al, 1996), particulate matter (Migel et al, 1995; Lee et al, 1999; 2000; 2001, Bohanon et al, 2003) and…”
BackgroundSimulation Analysis and Experimental Study of the Cooker Hoods of High-Rise Residential Buildings
Zhang, Y., Wang, T., Liu, X.-Q., Yong-ding, Z., & Yang, Y.-X. (2018) · Applied Sciences · doi:10.3390/app8050777 · Cited by 3
Personal Environmental Monitoring
Xie, S., & Himes, B. E. (2020) · Respiratory medicine · doi:10.1007/978-3-030-31507-8_20 · Cited by 4
Cruz, J. C. D., Amado, T. M., Meris, P. R. V., Manuel, M. C. E., Camaddo, J. M. A., & Lee, E. (2020) · IEEE Control and System Graduate Research Colloquium (ICSGRC) · doi:10.1109/icsgrc49013.2020.9232470 · Cited by 3
“The environment of restaurants, both indoor and outdoor, needs to be healthful and comfortable so that the health of the occupants will be protected from exposure to the contaminants of air pollution [1].”
BackgroundAljeesh, Y. I., Madhoun, W. A., Shamh, I. A., & Arcaya, M. (2016) · Cited by 7
Impacts of night market on indoor air quality and lung function of children in nearby households
Zhang, J. L., Wang, T., Lin, P., Lin, K.-T., Chen, Y., Jhang, J.-M., Yao, T.-C., Lin, Y., & Chen, P. (2025) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/s41370-025-00755-5 · Cited by 2
Comparison of Indoor Air Quality in Eateries Within Zaria Metropolis
Omole, O. A., Mbamali, I., & Abdulsalam, D. (2020) · International Journal of Atmospheric and Oceanic Sciences · doi:10.11648/j.ijaos.20200401.11 · Cited by 2
IMPACT ASSESSMENT OF COOKSTOVE EMISSION ON INDOOR ENVIRONMENT
Sarathe, S., Dwivedi, G., Baredar, P., Kesharvani, S., & Verma, P. C. (2024) · International Journal of Energy for a Clean Environment · doi:10.1615/interjenercleanenv.2024053777 · Cited by 2
Kolluru, S. S. R., Purkayastha, S. D., Barudgar, A., Ojha, A. R., Pawar, P., & Kumar, R. (2025) · Air Quality Atmosphere & Health · doi:10.1007/s11869-025-01819-z · Cited by 2
“Another study conducted in Chinese hot pot restaurant in metropoli - tan Hong Kong reported mean PM 2.5 concentrations of 81 µgm −3 (Lee et al. 2001).”
InfluentialOccupational Diseases among Office Workers
Koo, J. (2010) · Hanyang Medical Reviews · doi:10.7599/hmr.2010.30.4.274 · Cited by 2
INDOOR MICROBIAL CONTAMINATION THROUGH WATER MIST AEROSOL AT PUBLIC RESTAURANTS
Maryam, Z., Azira, M. R. R., Noor Faizul Hadry, N., Abdull, N., & Mohd Shukri, M. A. (2015) · Jurnal Teknologi · doi:10.11113/jt.v77.6706 · Cited by 2
“5 into consideration [7, 8, 9].”
Torkmahalleh, M. A. (2022) · Handbook of Indoor Air Quality · doi:10.1007/978-981-10-5155-5_13-1 · Cited by 4
Characterization of Indoor PM2.5 peak: New Indexes and Implications
Zhuo, S., Men, Y., Wang, J., Sun, J., Lei, Y., & Du, W. (2023) · Polish Journal of Environmental Studies · doi:10.15244/pjoes/157489 · Cited by 2
Hathorn, C. S., Mason, J., Gichuhi, P. N., Abdalla, M., Bovell‐Benjamin, A. C., Greene, J. L., Dansby, M., & Dean, D. R. (2006) · SAE technical papers on CD-ROM/SAE technical paper series · doi:10.4271/2006-01-2072 · Cited by 2
Mandal, D., Chakraborty, A., Tripathi, S., & Tripathi, S. N. (2025) · Atmospheric Environment · doi:10.1016/j.atmosenv.2025.121490 · Cited by 1
Cho, H., Gu, S., Kim, J., Kim, S., & Lee, K. (2013) · Korean Journal of Environmental Health Sciences · doi:10.5668/jehs.2013.39.2.144 · Cited by 1
Lasithiotakis, M., Xarchoulakos, D. C., & Potiriadis, C. (2019) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncz017 · Cited by 2
Kitchen Ventilation Requirements
Li, A., & Kosonen, R. (2019) · Springer eBooks · doi:10.1007/978-981-13-6496-9_2 · Cited by 1
Mosonik, B. C. (2022) · Journal of Physical and Applied Sciences (JPAS) · doi:10.51317/ecjpas.v2i1.372 · Cited by 4
Eghomwanre, A. F., Oyedele, P., Ehanire, G. O., Ebiziem, M. U., Ojehanon, C. O., Odumamwen, S., & Amadasun, F. U. (2023) · Journal of applied science and environmental management · doi:10.4314/jasem.v27i1.23 · Cited by 1
Zeng, J., Kagi, N., & Umishio, W. (2025) · Journal of Asian Architecture and Building Engineering · doi:10.1080/13467581.2025.2474816 · Cited by 1
“Additionally, Lee, Li, and Chan (2001) investigated not only PM 2.5 but also PM 10 mass concentrations using different cooking methods in four restaurants.”
InfluentialAn Integrated Occupational Hygiene Consultation Model for the Catering Industry
Lin, Y., & Lee, L. H. (2010) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/meq017 · Cited by 1
“0 (Lee et al., 2001b; Siegmann and Sattler, 1996), while measures of PAHs focused Downloaded from https://academic.oup.com/annweh/article-abstract/54/5/557/163674 by guest on 24 July 2018 on five hazardous substances, namely, pyrene, benzo[k]fluoranthene (BkF), benzo[a]pyrene (BaP),…”
BackgroundVolatile Organic Compounds Concentration in Northern Cold Area University in Harbin, China
Zhu, X., Shen, J., & Liu, Y. (2010) · International Conference on Bioinformatics and Biomedical Engineering · doi:10.1109/icbbe.2010.5516528
“Most research concerned about the environmental quality of indoor thermal environment [ 1-6 ].”
BackgroundIndoor air quality in restaurant kitchens in the south Tehran (2006)
Ghasemkhani, M., & Naseri, F. (2010) · DOAJ (DOAJ: Directory of Open Access Journals)
Effects of frying on indoor air quality
Toprak, M. (2013) · IYTE GCRIS Database (Izmir Institute of Technology)
Mathematical modeling of particle deposition and distribution in indoor environments
Chen, F. (2006) · DR-NTU (Nanyang Technological University) · doi:10.32657/10356/5245
Emission of Airborne Particulate Matter in Indoor Environments
Balasubramanian, R., Wei, S., & Karthikeyan, S. (2010) · CRC Press eBooks · doi:10.1201/ebk1439809624-18 · Cited by 1
Pagel, É. C. (2015) · Americanae (AECID Library) · Cited by 2
Characterisation of particulate matter emissions from cooking
Abdullahi, L. K. (2017) · University of Birmingham Institutional Research Archive (University of Birmingham) · Cited by 3
del Quindío, U., Yepes, M. E. G., Villamizar, R. H., del Quindío, U., Cremades, L. V., & de Catalunya, U. P. (2020) · Revista U D C A Actualidad & Divulgación Científica · doi:10.31910/rudca.v23.n2.2020.1555
Determinants of paediatric asthma: a three-level approach
Paciência, I. (2021) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) · doi:10.34626/mpya-y725
Lasithiotakis, M., Xarchoulakos, D. C., & Potiriadis, C. (2019) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncz135
Oğur, S., & GÜLTEKİN, M. S. (2022) · European Journal of Science and Technology · doi:10.31590/ejosat.1180150
Spatial and Temporal Distribution of Air Pollutants Over the Capital Area in LaosPreprint
Lee, D., Joo, S., Sim, J., Yun, S. B., Noh, Y., Hong, C. S., Lee, K., Atsanavong, L., Phanphongsa, V., & Kim, K. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.4780543
Enhancing Indoor Air Quality Standards in Abu Dhabi Restaurants: Evaluation and Implications
Aldeeri, B., Almezeini, K., & Sheta, W. (2024) · Studies in systems, decision and control · doi:10.1007/978-3-031-71649-2_15
Ventilation rate in three types of opening ratio at the domestic kitchen
Lee, M.-C., & Shih, P.-T. (2025) · E3S Web of Conferences · doi:10.1051/e3sconf/202567202014
Xie, S., Meeker, J. R., Perez, L., Eriksen, W., Localio, A., Park, H., Jen, A., Goldstein, M., Temeng, A., Morales, S. M., et al. (2021) · Figshare · doi:10.6084/m9.figshare.16571979
Characteristics of Electronic Cigarette Aerosol and Its Impact on Indoor Air Quality
Li, L. (2021) · eScholarship (California Digital Library)
The chemical speciation and phase distribution of atmospheric oxidized mercury
Ghoshdastidar, A. (2019) · eScholarship@McGill (McGill) · doi:10.82308/29388
The Influence of Restaurant Zones on Local Air Quality: Evidence from Novi Sad
Stošić, I., & Kosić, T. (2025) · Global Sustainability Challenges · doi:10.62907/uunt_gsc250301008s
Chemical Partitioning and Multiphase Oxidation of Organic Contaminants in the Indoor Environment
Yu, J. (2024) · TSpace (University of Toronto)
L'acide nitreux atmosphérique : implications dans la chimie en milieu urbain
Afif, C. (2008) · theses.fr (ABES) · doi:10.70675/3028a8a7z20fez493dz80e3z386329cec62e · Cited by 4
Nasreddine, R. (2016) · theses.fr (ABES) · doi:10.70675/a7bab851z1e6dz40edzb1faze3dbc5a54b8d · Cited by 2
Barudgar, A., Ojha, A. R., Borse, S., Mahale, S., Kumar, R. G., Yadav, P., & Pawar, P. R. (2026) · Air Quality Atmosphere & Health · doi:10.1007/s11869-026-02020-6
“Air-conditioned restaurants paradoxically exhibit higher 7–10 PM concentrations than non-AC ones due to poor HVAC maintenance and pollutant recirculation (Lee et al. 2001; Chang et al. 2021).”
Evaluation and Application of Low-Cost Air Quality Sensors in Hungary
Atfeh, B. (2026) · Eötvös Loránd Tudományegyetem · doi:10.15476/elte.2025.317
Niu, M., Yao, Y., Lin, Z., Tang, X., Chen, H., Paulson, S. E., Destaillats, H., & Zhu, Y. (2026) · ACS ES&T Air · doi:10.1021/acsestair.6c00144
Yuksel, B., & Yildirim, S. A. (2026) · Frontiers in Public Health · doi:10.3389/fpubh.2026.1953388
Sundaram, A. M. (2026) · Energy and Buildings · doi:10.1016/j.enbuild.2026.118310
Rawat, P., Mao, J., Jia, S., Bau, S., & Sarkar, S. (2026) · Atmospheric Environment · doi:10.1016/j.atmosenv.2026.122399
Majumdar, D., & Chaudhury, A. (2026) · Indoor and Built Environment · doi:10.1177/1420326x261494754
Metadata
- Authors
- Lee, S. C., Li, W.-M., & Yin Chan, L.
- Affiliations
- Hong Kong Polytechnic University (HK)
- Corresponding author
- Lee, Shun Cheng
- Venue
- Science of The Total Environment
- Publisher
- Elsevier BV
- Published
- 2001-11
- Volume
- 279
- Issue
- 1-3
- Pages
- 181-193
- ISSN
- 0048-9697 (ISSN-L)
- OpenAlex
- W2035279765
- Cited by
- 263
- References
- 13
- Citations by year
- 2026: 6 · 2025: 13 · 2024: 16 · 2023: 17 · 2022: 22 · 2021: 13 · 2020: 28 · 2019: 18 · 2018: 14 · 2017: 13 · 2016: 6 · 2015: 13 · 2014: 11 · 2013: 11 · 2012: 5
- FWCI
- 3.54
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Science of The Total Environment (publishedVersion)
- PubMed (publishedVersion)
- PolyU Institutional Research Archive (Hong Kong Polytechnic University) (submittedVersion)
- Funders
- University of Hong Kong
- Hong Kong Polytechnic University
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Physical Sciences › Environmental Science › Pollution › Energy and Environment Impacts
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Air Quality and Health Impacts
- Keywords
- indoor air quality, restaurants, cooking emissions, gas stoves, hot pot, dim sum, carbon monoxide, carbon dioxide, particulate matter, volatile organic compounds, Hong Kong
- MeSH terms
- Carbon Dioxide, Carbon Monoxide, Cooking, Environmental Monitoring, Hong Kong, Humans, Hydrocarbons, Organic Chemicals, Particle Size, Restaurants, Volatilization, Air Pollution, Indoor
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.