Indoor air quality at restaurants with different styles of cooking in metropolitan Hong Kong
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Indoor air quality (IAQ) of a restaurant has increasingly received a lot of public concerns in Hong Kong. Unfortunately, there is limited data about the IAQ of Hong Kong restaurants. In order to characterize the current IAQ of local restaurants, four restaurants in metropolitan Hong Kong including a Korean barbecue style restaurant, a Chinese hot pot restaurant, a Chinese dim sum restaurant and a Western canteen were selected for this study. The results of this study showed that the mean concentrations of CO2 at restaurants with gas stoves for food cooking in dining areas exceeded the range from 40 to 60% indoor CO2 concentrations at restaurants without gas stoves in dining areas. The average levels of PM10 and PM2.5 at the Korean barbecue style restaurant were as high as 1442 and 1167 microg/m3, respectively. At the Korean barbecue and Chinese hot pot restaurants, the levels of PM2.5 accounted for 80-93% of their respective PM10 concentrations. The 1-h average levels of CO observed at Korean barbecue style and hot pot restaurants were 15,100 and 8000 microg/m3, respectively. Relatively high concentrations of CO2, CO, PM10, PM2.5 benzene, toluene, methylene chloride and chloroform were measured in the dining areas of the Korean barbecue style and the Chinese hot pot restaurants. The operations of pan-frying food and boiling food with soup in a hot pot could generate considerable quantities of air pollutants.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Samples collected at 10 retail shops in a large shopping center from 2002–2004 had high levels of toluene and xylene (144 and 3.5 μg/m3, respectively), but slightly lower levels of chloroform, methylene chloride, heptane and hexane (0.5, 0.8, 1.8 and 3.2 μg/m3) than the present study [56].”
From Occupational exposure and health risks of volatile organic compounds of hotel housekeepers: Field measurements of exposure and health risks (2021) · cites this paper as [56]
Citations
Cites
Ventilation for Acceptable Indoor Air Quality
Falih, M. (2019) · Cited by 2,497
Sources of fine organic aerosol. 1. Charbroilers and meat cooking operations
Rogge, W. F., Hildemann, L. M., Mazurek, M. A., Cass, G. R., & Simoneit, B. R. T. (1991) · Environmental Science & Technology · doi:10.1021/es00018a015 · Cited by 720
Baek, S.-O., Kim, Y.-S., & Perry, R. (1997) · Atmospheric Environment · doi:10.1016/s1352-2310(96)00215-4 · Cited by 298
Emissions of Carbonyl Compounds from Various Cookstoves in China
Zhang, J., & Smith, K. R. (1999) · Environmental Science & Technology · doi:10.1021/es9812406 · Cited by 182 · cited 1×
“Some studies reported that elevated formaldehyde concentrations in cooking smoke Žwere measured during cooking hours Raiyani et .al., 1993; Zhang and Kirk, 1999 .”
BackgroundMutagens From Heated Chinese and U.S. Cooking Oils
Shields, P. G., Xu, G. X., Blot, W. J., Fraumeni, J. F., Trivers, G. E., Pellizzari, E. D., Qu, Y. H., Gao, Y. T., & Harris, C. C. (1995) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/87.11.836 · Cited by 158 · cited 4×
“Shields et al., 1995 .”
BackgroundInfluentialCancer and occupation in Massachusetts: A death certificate study
Dubrow, R., & Wegman, D. H. (1984) · American Journal of Industrial Medicine · doi:10.1002/ajim.4700060305 · Cited by 133 · cited 1×
“Coggon et al., 1986; Dubrow and Wegman, 1984 .”
BackgroundCharacterization and problems of indoor pollution due to cooking stove smoke
Raiyani, C. V., Shah, S., Desai, N. M., Venkaiah, K., Patel, J. S., Parikh, D. J., & Kashyap, S. K. (1993) · Atmospheric Environment Part A General Topics · doi:10.1016/0960-1686(93)90227-p · Cited by 122
Analysis of Polycyclic Aromatic Hydrocarbons in Cooking Oil Fumes
Shu-guang, L., Dinhua, P., & Guoxiong, W. (1994) · Archives of Environmental Health An International Journal · doi:10.1080/00039896.1994.9937464 · Cited by 112 · cited 1×
“Li et al., 1994 .”
A survey of cancer and occupation in young and middle aged men. I. Cancers of the respiratory tract.
Coggon, D., Pannett, B., Osmond, C., & Acheson, E. D. (1986) · Occupational and Environmental Medicine · doi:10.1136/oem.43.5.332 · Cited by 111 · cited 1×
“Coggon et al., 1986; Dubrow and Wegman, 1984 .”
BackgroundRisk of developing lung cancer in relation to exposure to fumes from Chinese-style cooking
Zhong, L., Goldberg, M., Parent, M., & Hanley, J. (1999) · Scandinavian Journal of Work Environment & Health · doi:10.5271/sjweh.440 · Cited by 69 · cited 1×
“One possible answer to this question is that Chinese women are more exposed to cooking fumes that contain a variety of airborne carcinoŽgens Zhong et al., 1999; Benfenati et al., 1998; .”
Background
Cited by
Items 101–200 of 272
Zheng, Z., Zhang, H., Qian, H., Li, J., Yu, T., & Liu, C. (2022) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2022.156614 · Cited by 28
Colorimetric Sensing of Volatile Organic Compounds Produced from Heated Cooking Oils
Duffy, E., Cauven, E., & Morrin, A. (2021) · ACS Omega · doi:10.1021/acsomega.0c05667 · Cited by 27
“The array was designed to target VOCs commonly found in cooking oil emissions (aldehydes, ketones, and carboxylic acids) by incorporating pararosaniline, 4,4-azodianiline, and pH indicators as sensing materials.”
The Impact of Kitchen Activities on Indoor Pollutant Concentrations
Tian, L., Zhang, G., Zhang, Q., Moschandreas, D. J., Hao, J., Lin, J., & Liu, Y. (2008) · Indoor and Built Environment · doi:10.1177/1420326x08094626 · Cited by 27
Chemical and stable isotopic characteristics of PM2.5 emitted from Chinese cooking
Jung, C., & Su, H.-J. J. (2020) · Environmental Pollution · doi:10.1016/j.envpol.2020.115577 · Cited by 27
Pikmann, J., Drewnick, F., Fachinger, F., & Borrmann, S. (2024) · Atmospheric chemistry and physics · doi:10.5194/acp-24-12295-2024 · Cited by 28
“…Mar´c et al., 2018; Zhang et al., 2010) In addition, the sampling approach itself (e.g., sampling location or dilution of samples) and the analysis procedure (e.g., focusing on peak levels or integrating over the entire cooking process) can have a strong influence on the resulting emission data.”
Indoor emissions of total and fluorescent supermicron particles during HOMEChem
Tian, Y., Arata, C. M., Boedicker, E. K., Lunderberg, D. M., Patel, S., Sankhyan, S., Kristensen, K. V., Misztal, P. K., Farmer, D. K., Vance, M. E., et al. (2020) · Indoor Air · doi:10.1111/ina.12731 · Cited by 28
Characterisation of Volatile Organic Compounds at Hotels in Southern China
Chan, C. S., Lee, S. C., Chan, W., Ho, K. F., Tian, L., Lai, S. C., Li, Y. S., & Huang, Y. (2011) · Indoor and Built Environment · doi:10.1177/1420326x11409458 · Cited by 25
Self-citationNovel kitchen ventilation system with the cabinet-bottom air supply
Yang, F., Gao, J. Q., Cao, C., Zeng, L., Wang, L., Liu, Z., & Zheng, Z. (2022) · Journal of Building Engineering · doi:10.1016/j.jobe.2022.105137 · Cited by 25
Song, Y., Sun, L., Wang, X., Zhang, Y., Wang, H., Li, R., Xue, L., Chen, J., & Wang, W. (2018) · Frontiers of Environmental Science & Engineering · doi:10.1007/s11783-018-1024-0 · Cited by 25
“To determine the chemical compositions of gaseous and particulate pollutants from barbecue cooking, combustion experiments were carried out in a combustor or kitchen [29,30].”
MethodVolatile Organic Compounds in the Air of 25 Greek Homes
Baya, M. P., Bakeas, E. B., & Siskos, P. A. (2004) · Indoor and Built Environment · doi:10.1177/1420326x04036007 · Cited by 25
Badyda, A. J., Krawczyk, P., Bihałowicz, J. S., Bralewska, K., Rogula–Kozłowska, W., Majewski, G., Oberbek, P., Marciniak, A., & Rogulski, M. (2020) · Energies · doi:10.3390/en13236245 · Cited by 24
The emission characteristics of hydrocarbon from Chinese cooking under smoke control
Lin, Y., Shao, M., & Lü, S. (2010) · International Journal of Environmental & Analytical Chemistry · doi:10.1080/03067310903194964 · Cited by 23
Impact of the Restaurant Chimney Emissions on the Outdoor Air Quality
ElSharkawy, M. F., & Ibrahim, O. A. (2022) · Atmosphere · doi:10.3390/atmos13020261 · Cited by 26
“Numerous previous studies revealed that emission of pollutants from frying food on a hot steel pan and broiling food on steel bars above a charcoal burner was always higher than those of any other methods of cooking [12,48,49].”
BackgroundPM2.5 Concentrations Indoors and Outdoors in Heavy Air Pollution Days in Winter
Song, P., Wang, L., Yang, H. K., & Li, R. (2015) · Procedia Engineering · doi:10.1016/j.proeng.2015.09.173 · Cited by 23
Association between microenvironment air quality and cardiovascular health outcomes
Tan, Y., Rashid, S. K. A., Pan, W., Chen, Y., Yu, L. E., & Seow, W. J. (2020) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2020.137027 · Cited by 23
Lee, J.-B., Kim, K., Kim, H.-J., Cho, S.-J., Jung, K., & KIM, S. (2011) · The Scientific World JOURNAL · doi:10.1100/tsw.2011.103 · Cited by 23
“There are only a limited number of studies that have attempted to measure emissions from restaurants or households[8,9,10,11,12,13,14,15].”
BackgroundIqbal, M. A., & Kim, K. (2015) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.11.005 · Cited by 22
Lu, S. W., Zhou, B., Zhang, J., Hou, M., Jiang, J., Li, F., & Wang, Y. H. (2021) · Energy and Buildings · doi:10.1016/j.enbuild.2021.110907 · Cited by 22
Variability of BTEX in Residential Indoor Air of Kolkata Metropolitan City
Majumdar, D., Mukherjee, A. K., Mukhopadhaya, K., & Sen, S. (2011) · Indoor and Built Environment · doi:10.1177/1420326x11409465 · Cited by 22
Influence of indoor air quality on sleep quality of university students in Lisbon
Ramos, J., Belo, J., Silva, D., Diogo, C., Almeida, S. M., & Canha, N. (2021) · Atmospheric Pollution Research · doi:10.1016/j.apr.2021.101301 · Cited by 21
Wang, Z., Yu, T., Ye, J., Tian, L., Lin, B., Leng, W., & Liu, C. (2023) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2023.132583 · Cited by 21
Assessing the impact of kitchen hoods and ventilation openings on indoor air quality post-cooking
Chen, S.-W., Chang, C.-Y., & Chan, Y.-C. (2025) · Journal of Building Engineering · doi:10.1016/j.jobe.2024.111721 · Cited by 21
McGrath, J. A., Byrne, M., ASHMORE, M. R., Terry, A. C., & Dimitroulopoulou, S. (2014) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2014.05.081 · Cited by 23
Survey study on Chinese commercial kitchen exhaust fume systems in Tianjin
Zhang, A., Deng, N., Shen, C., Hao, R., Liu, J., Wang, Y., & Long, Z. (2019) · Building and Environment · doi:10.1016/j.buildenv.2019.106629 · Cited by 21
Investigation on inherent angle ventilation control of residential kitchen range hoods
Guo, Z., Li, H., Feng, G., Huang, K., & Yu, T. (2024) · Energy and Built Environment · doi:10.1016/j.enbenv.2024.01.001 · Cited by 20
Impact of Commercial Cooking on Urban PM2.5 and O3 with Realtime Data-Assisted Emission Inventory
Yuan, Y., Zhu, Y., Lin, C., Wang, S., Xie, Y., Hai-xian, L., Xing, J., Zhao, B., Zhang, M., & You, Z. (2022) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2023.162256 · Cited by 20
“In addition, previous studies of commercial cooking impact assessment were mainly concentrated on indoor air quality (Kang et al., 2019; Lee et al., 2001; Militello-Hourigan and Miller, 2018; Seaman et al., 2009), whereas less attention has been paid to outdoor air quality.”
Occupational Diseases Among Office Workers and Prevention Strategies
Lee, J., & Koo, J. (2015) · Journal of the Ergonomics Society of Korea · doi:10.5143/jesk.2015.34.2.125 · Cited by 19
“It is well known that there are differences of various pollutants between the indoor and the outdoor environment (Lee et al., 2001).”
BackgroundLi, Y., Wu, A., Wu, Y., Xu, J., Zhao, Z., Tong, M., & Luan, S. (2019) · Aerosol Science and Technology · doi:10.1080/02786826.2019.1645292 · Cited by 21
“…have been performed to investigate the characteristics of inorganic and organic fractions of PM generated during cooking (Rogge et al. 1991, 1993; Lee, Li, and Chan 2001; See and Balasubramanian 2006a, 2006b, 2008; Susaya et al. 2010; Buonanno et al. 2011; Shipley, Peishi, and Qing 2018).”
BackgroundHealth risk assessment of chefs intake of cooking fumes: Focusing on Sichuan cuisine in China
Tong, R., Zhang, B., Yang, X., & Cao, L. (2019) · Human and Ecological Risk Assessment An International Journal · doi:10.1080/10807039.2019.1698282 · Cited by 19
Jia, C., Zhong, W., Deng, M., & Jiang, J. (2018) · The Journal of Chemical Physics · doi:10.1063/1.5021712 · Cited by 19
Colbeck, I., & Nasir, Z. A. (2010) · Environmental pollution · doi:10.1007/978-90-481-8663-1_2 · Cited by 20
“The majority of the work on particulate emissions from cooking has considered indoor PM 10 or PM 2.5 concentrations in houses or restaurants (Lee et al. 2001; Monkkonen et al. 2005; Fortmann et al. 2001).”
BackgroundInfluentialZhao, D., & You, X. (2021) · Building Simulation · doi:10.1007/s12273-021-0767-x · Cited by 19
Çankaya, S., Pekey, H., Pekey, B., & Aydın, B. Ö. (2018) · Human and Ecological Risk Assessment An International Journal · doi:10.1080/10807039.2018.1539638 · Cited by 19
“In another scientific study, barbecue cooking, hot pot cooking, dim sum meal preparation, and western fast food preparation were compared, and the highest VOC concentrations were detected with barbecue cooking (Lee et al. 2001).”
BackgroundIndoor Air Quality of Typical Malaysian Open-air Restaurants
Yusup, Y., Ahmad, M. I., & Ismail, N. (2014) · Environment and Pollution · doi:10.5539/ep.v3n4p10 · Cited by 22
“Numerous studies still adopt this comparison (Baek et al., 1997; Lee et al., 2002; Lee et al., 2001).”
Air Quality at Night Markets in Taiwan
Zhao, P., & Lin, C.-C. (2010) · Journal of the Air & Waste Management Association · doi:10.3155/1047-3289.60.3.369 · Cited by 18
Contribution of Chinese Hot Pot and Barbecue Restaurants on Indoor Environmental Parameters
Zhao, Y., Tao, P., Zhang, B., & Huan, C. (2020) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2020.04.0141 · Cited by 19
“This finding is consistent with the study conducted by Lee et al. (2001) and Chen et al. (2007) for some restaurant environments.”
Kim, J., Han, S. J., & Yoo, K. (2022) · Atmosphere · doi:10.3390/atmos13091373 · Cited by 16
Madureira, J., Mendes, A., & Teixeira, J. P. (2014) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2013.852279 · Cited by 20
“These findings are consistent with other studies conducted in restaurant environments.(29,53) As evidenced by the indoor CO2 concentrations (Table II), generally considered an indicator of inadequate fresh air supply, restaurants were inadequately ventilated, according to Portuguese regulation (1800 mg.”
ResultAbabio, B. A., Nkansah, M. A., Hogarh, J. N., Agyekum, T. P., & Commeh, M. K. (2023) · Journal of Hazardous Materials Advances · doi:10.1016/j.hazadv.2023.100358 · Cited by 16
Research on the Impact of Indoor Control Quality Monitoring Based on Internet of Things
Pang, L., Luo, C., & Pan, W. (2023) · IEEE Access · doi:10.1109/access.2023.3336706 · Cited by 15
“The air was sampled and then brought back to the laboratory for analysis [12], [13], [14].”
MethodConcentrations and bioaccessibilities of trace elements in barbecue charcoals
Sharp, A., & Turner, A. (2013) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2013.09.020 · Cited by 15
(2019) · Royal Society of Chemistry eBooks · doi:10.1039/9781788016179 · Cited by 16
Exposure assessment of emissions from mobile food carts on New York City streets
Nahar, K., Rahman, M. M., Raja, A., Thurston, G. D., & Gordon, T. (2020) · Environmental Pollution · doi:10.1016/j.envpol.2020.115435 · Cited by 14
Chen, Y., Yang, X.-E., Lin, K. A., Huang, W.-W., Lin, C.-C., & Yu, K. (2020) · Environmental Science and Pollution Research · doi:10.1007/s11356-020-09929-0 · Cited by 13
Jiang, J., Liu, J., Wang, C., Yin, Y., Hassan, M. A., Pei, J., Hyun, O., & Park, H. (2024) · Building and Environment · doi:10.1016/j.buildenv.2024.111951 · Cited by 12
Sankaran, G., Tan, S. T., Shen, J., Gutiérrez, R. A., Ng, L. C., & Sim, S. (2023) · Atmospheric Environment · doi:10.1016/j.atmosenv.2023.119645 · Cited by 12
Alhajeri, N. S., Alrashidi, A. M., Yassin, M. F., & Al-Awadi, L. (2024) · Environmental Quality Management · doi:10.1002/tqem.22198 · Cited by 13
COMPARISON OF INDOOR AIR QUALITY IN RESTAURANT KITCHENS IN TEHRAN WITH AMBIENT AIR QUALITY
Ghasemkhani, M., & Naseri, F. (2008) · Bioline International (Bioline International) · Cited by 12
Laltrello, S., Amiri, A., & Lee, S. (2022) · Aerosol and Air Quality Research · doi:10.4209/aaqr.210302 · Cited by 12
“Frying emitted a considerable amount of indoor PM 2.5 with an average of 8.7 µ g m – 3 over the events studied, which is comparable to past studies (Abdullahi et al. , 2013; Lee et al. , 2001; Massey et al. , 2012; Zhang et al. , 2010).”
MethodResultInfluentialSelf-citationShi, L., Liu, Z., Wen, W., Son, J. H., Li, L., Wang, L., & Chen, J. (2023) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2023.163243 · Cited by 12
Modeling the Dispersion of Volatile Organic Compounds in Indoor Environment
Davardoost, F., & Kahforoushan, D. (2018) · Chemical Engineering & Technology · doi:10.1002/ceat.201800244 · Cited by 12
Yang, J., Seo, J.-H., Jeong, N.-N., & Sohn, J. R. (2019) · Environmental Management · doi:10.1007/s00267-019-01195-2 · Cited by 12
“5, and VOCs that increase in the dining area (Lee et al. 2001).”
BackgroundOnchang, R., & Panyakapo, M. (2014) · Indoor and Built Environment · doi:10.1177/1420326x14543209 · Cited by 16
A novel dataset of indoor environmental conditions in work-from-home settings
Manu, S., & Rysanek, A. (2024) · Building and Environment · doi:10.1016/j.buildenv.2024.112222 · Cited by 12
Experimental study on particle splash pollution from cooking with fluorescent droplets
Kong, L., Liu, J., Ren, J., Liu, S., Li, J., & Wang, J. (2020) · Building and Environment · doi:10.1016/j.buildenv.2020.106973 · Cited by 11
Measurement of Indoor Air Quality in Chinese Charcoal Barbecue Restaurants
Zhang, Z., Zhao, Y., Zhou, M., Tao, P., & Li, R. (2017) · Procedia Engineering · doi:10.1016/j.proeng.2017.10.088 · Cited by 11
Lee, J.-B., Kim, H.-J., Jung, K., & Kim, S.-D. (2009) · Korean Journal of Environmental Health Sciences · doi:10.5668/jehs.2009.35.4.315 · Cited by 11
Lee, S., Yu, S., & Kim, S. (2017) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph14010078 · Cited by 11
“According to Lee et al. (2001) [23], the average levels of PM2.”
BackgroundSelf-citationShi, Y., & Ng, E. (2017) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph14091008 · Cited by 11
“Moreover, the types of the fine-scale emission sources in these three districts are also similar (as mentioned in the paper, vehicular pollutants, the densely distributed bus stops [27], restaurants and commercial cooking [28], etc.”
BackgroundA coupled fluids-chemistry model for pollutant dynamics indoors—Application to a kitchen scenario
Liu, Z., Pfrang, C., Sommariva, R., Brean, J., Su, Y., Bloss, W. J., & Fraga, B. (2025) · Physics of Fluids · doi:10.1063/5.0270416 · Cited by 10
Indoor air quality monitoring and management in hospitality: an overarching framework
Zanni, S., Mura, M., Longo, M., Motta, G., & Caiulo, D. (2022) · International Journal of Contemporary Hospitality Management · doi:10.1108/ijchm-12-2021-1549 · Cited by 10
Halios, C. H., Santamouris, M., Helmi, A., Kapsalaki, M., Saliari, M., Spanou, A., & Tsakos, D. (2009) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2009.02.023 · Cited by 10
A real-time personal PM2.5 exposure monitoring system and its application for college students
Yang, W., & Zhao, B. (2024) · Building Simulation · doi:10.1007/s12273-024-1163-0 · Cited by 9
“Additionally, existing research methods often focus on measuring individual exposure concentration during single activity periods and are not applicable for assessing group exposure concentrations throughout the entire day (Lee et al. 2001; Braniš et al. 2010; Zeng et al. 2020).”
Ghoshdastidar, A. J., Hu, Z., Nazarenko, Y., & Ariya, P. A. (2018) · Environmental Science and Pollution Research · doi:10.1007/s11356-018-1201-5 · Cited by 9
“…known that cooking emissions, particularly from frying, contain high concentrations of toxic and carcinogenic chemicals, such as CO2, CO, benzene, toluene, methylene chloride, and chloroform, as well as aerosols, potentially contributing to incidence of cancer (Lee et al. 2001; Zhong et al. 1999).”
BackgroundZou, M.-L., Jiang, C., Chen, Y., Wu, C., Lung, S. C., Chien, L., Kallawicha, K., Lo, Y., & Chao, H. J. (2021) · Environmental Research · doi:10.1016/j.envres.2021.112567 · Cited by 9
Bräuner, E. V., Frederiksen, M., Kolarik, B. D., & Gunnarsen, L. (2014) · Building and Environment · doi:10.1016/j.buildenv.2014.08.020 · Cited by 9
Kim, S., Lee, T.-J., Jeon, J.-M., Kim, D.-S., & Jo, Y. M. (2020) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2020.09.0457 · Cited by 8
“The amount of particulate matter (PM) exhausted from meat charbroiling is very small, comprised mostly of PM 2.5 in tiny liquid or solid droplets (Lee, 1999; Lee et al. , 2001; Lee et al. , 2009).”
InfluentialDhiman, R., Sharma, R., Jain, A., Ambekar, A., Thajudeen, T., & Guttikunda, S. (2024) · Indoor Environments · doi:10.1016/j.indenv.2024.100008 · Cited by 8
Yang, J., Strodl, E. S., Wu, C., Hou, X., Yin, X., Wen, G., Sun, D., Xian, D., Chen, J.-Y., Chen, Y., et al. (2022) · Environmental Science and Pollution Research · doi:10.1007/s11356-022-21113-0 · Cited by 9
The effects of carbon monoxide on respiratory chemoreflexes in humans
Vesely, A. E., Somogyi, R. B., Sasano, H., Sasano, N., Fisher, J. A., & Duffin, J. (2003) · Environmental Research · doi:10.1016/s0013-9351(03)00107-5 · Cited by 8
PM10 Emissions from Cooking Fuels in Nigerian Households and Their Impact on Women and Children
Mbanya, V. N., & Sridhar, M. K. C. (2017) · Health · doi:10.4236/health.2017.913126 · Cited by 8
Jang, E., Yoo, J., & Cho, M. (2022) · International Journal of Contemporary Hospitality Management · doi:10.1108/ijchm-05-2022-0632 · Cited by 7
Specific Indoor Environmental Quality Parameters in College Computer Classrooms
Chang, F.-H., Li, Y. Y., Tsai, C.-H., & Yang, C. (2009) · International Journal of Environmental Research · doi:10.22059/ijer.2010.67 · Cited by 9
Carneiro, G., Braz, D., de Jesus, E. F., Santos, S. M.-D., Cardoso, K., Hecht, A., & da Cunha, M. K. D. (2012) · Environmental Geochemistry and Health · doi:10.1007/s10653-012-9497-4 · Cited by 7
Estimation of CO2 Emissions Produced by Commercial Grills in Veracruz, Mexico
Lango-Reynoso, V., López-Spiegel, J., Lango‐Reynoso, F., Castañeda‐Chávez, M. D. R., & Montoya‐Mendoza, J. (2018) · Sustainability · doi:10.3390/su10020464 · Cited by 7
“The high concentration of CO2 was associated with inadequate ventilation [65].”
BackgroundShi, Z., Xu, X., Wang, Y., Ma, S., Meng, C., Dong, J., & Cao, H. (2025) · Journal of Building Engineering · doi:10.1016/j.jobe.2025.112442 · Cited by 6
Rincón, G., Morantes, G., Garcia‐Angulo, A. C., Mota, S., Cornejo-Rodriguez, M. D. P., & Jones, B. (2025) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2025.179628 · Cited by 6
Investigation of Indoor Air Quality and Staff Satisfaction in Underground Buildings in Xi’an, China
Zhang, X., Fan, Y., Yu, W., Wang, H., Zhao, F., Tao, H., & Fu, Z. (2021) · Polish Journal of Environmental Studies · doi:10.15244/pjoes/130966 · Cited by 6
“itself also produced most particulate matter due to the combustion of a large amount of fuel [30] .”
BackgroundThe Detection of Activities Occurring Inside Quick Service Restaurants That Influence Air Quality
Szczurek, A., Azizah, A., & Maciejewska, M. (2022) · Sensors · doi:10.3390/s22114056 · Cited by 7
Collins, D. C. A., Parsons, M., & Zinyemba, C. (2013) · International Journal of Environmental Health Research · doi:10.1080/09603123.2013.807328 · Cited by 6
“Lee et al. (2001) reported very high mean levels of PM2.”
BackgroundRanasinghe, R. S. A., Sugathapala, A., Lee, S., Hung, W. T., Ho, K., Chan, C. S., Huang, Y., & Cheng, Y. (2014) · Indoor and Built Environment · doi:10.1177/1420326x13517252 · Cited by 6
Self-citationCharacteristics of PM from Different South Indian Cooking Methods and Implications in Health Effects
Deepthi, Y., Nagendra, S. M. S., & Gummadi, S. N. (2020) · Lecture notes in civil engineering · doi:10.1007/978-981-15-1334-3_5 · Cited by 6
(2013) · CRC Press eBooks · doi:10.1201/b14391-42 · Cited by 7
Indoor Air Pollution at Restaurant Kitchen in Delhi NCR
Kumari, P., & Mandal, P. (2020) · Lecture notes in civil engineering · doi:10.1007/978-981-15-6887-9_18 · Cited by 5
Consumers’ Perceived quality of Restaurants in Nueva Ecija
Vigilia, A. Y. (2020) · Journal of Humanities and Education Development · doi:10.22161/jhed.2.6.19 · Cited by 5
“Further, restaurants may be regarded as indoor 'public spaces where both local and international individuals choose to spend a lot of their time (Lee et al., 2001).”
BackgroundZhang, W. Y., Bai, Z., Shi, L., Son, J. H., Li, L., Wang, L., & Chen, J. (2022) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2022.158385 · Cited by 5
Son, J. H., Shi, L., Zhang, W., Bai, Z., Li, L., Wang, L., & Chen, J. (2022) · Air Quality Atmosphere & Health · doi:10.1007/s11869-022-01292-y · Cited by 5
Distribution Characteristics of Cooking Oil Fume Particles in Residential Kitchens in Cold Regions
Yuan, Y., Wang, Q., Zhang, S., Zhu, N., & Zhao, M. (2023) · Buildings · doi:10.3390/buildings13051227 · Cited by 5
Acute cardiovascular autonomic responses to inhaled particulates
Evans, J. M., Jenkins, R. A., Ilgner, R. H., Knapp, C. F., Zhang, Q., & Patwardhan, A. R. (2014) · European Journal of Applied Physiology · doi:10.1007/s00421-014-2998-3 · Cited by 7
Evaluation of the Indoor Air Quality in Restaurants Before and After a Smoking Ban in Portugal
Madureira, J., Mendes, A., Santos, H., Vilaça, J., Neves, M. P., Mayan, O. N., & Teixeira, J. P. (2011) · Indoor and Built Environment · doi:10.1177/1420326x11409459 · Cited by 6
Occurrence of selected volatile organic compounds in a bra cup manufacturing facility
Kularatne, R. K. A. (2016) · International Journal of Environmental Science and Technology · doi:10.1007/s13762-016-1145-6 · Cited by 5
“…air from various sources such as paints, adhesives, furniture, clothing, building materials, combustion materials (Li et al. 2001; Lee et al. 2002b;Guo et al. 2004;Wilke et al. 2004;Nielsen et al. 2007; Chang et al. 2011) and even from certain types of cooking (Baek et al. 1997; Lee et al. 2001).”
BackgroundJung, C., Syu, Z.-H., Su, H.-J. J., Lian, P.-Y., & Chen, N.-T. (2022) · Environmental Research · doi:10.1016/j.envres.2022.113346 · Cited by 5
Sjaastad, A. K. (2010) · NORA - Norwegian Open Research Archives · Cited by 12
Lim, H.-J., & Kim, M.-G. (2015) · Analytical Science and Technology · doi:10.5806/ast.2015.28.3.236 · Cited by 4
Maciejewska, M., Azizah, A., & Szczurek, A. (2023) · Sensors · doi:10.3390/s23177630 · Cited by 4
“5 benzene, toluene, methylene chloride, and chloroform were measured in the dining areas of Korean barbecue style and Chinese hot pot restaurants [11].”
BackgroundSabeur, A., Tounsi, I. M., Morsli, S., & Ganaoui, M. E. (2025) · Environmental sciences · doi:10.5772/intechopen.1008551 · Cited by 4
Status of Carbonaceous Aerosol at Indoor Environment of a Cafeteria in Delhi, India—A Case Study
Mandal, P., Nagesh, M. S., & Mandal, A. (2020) · Lecture notes in civil engineering · doi:10.1007/978-981-15-1334-3_2 · Cited by 5
Whittaker, S., Deziel, N. C., Zhang, Y., Jin, L., Edwards, Q. A., Naraine, L., Scarborough, J., Allen, D. T., & Bell, M. L. (2020) · Environmental Research Communications · doi:10.1088/2515-7620/ab7abc · Cited by 4
Impact of Grilling Meat or Fish at Home on Peak Expiratory Flow Rate in Adults With Asthma
Lee, H. J., Chung, S. J., Park, J., Kim, S., Park, D. W., Sohn, J. W., Kim, S., Park, C., & Yoon, H. J. (2020) · Allergy Asthma and Immunology Research · doi:10.4168/aair.2020.12.4.729 · Cited by 4
An Evaluation of Best Practices in an Air Quality Student Science Project in Ethiopia
Dingemanse, J. D., & Wit, G. D.-D. (2022) · Aquademia · doi:10.21601/aquademia/11828 · Cited by 5
Metadata
- Authors
- Lee, S. C., Li, W.-M., & Yin Chan, L.
- Affiliations
- Hong Kong Polytechnic University (HK)
- Corresponding author
- Lee, Shun Cheng
- Venue
- Science of The Total Environment
- Publisher
- Elsevier BV
- Published
- 2001-11
- Volume
- 279
- Issue
- 1-3
- Pages
- 181-193
- ISSN
- 0048-9697 (ISSN-L)
- OpenAlex
- W2035279765
- Cited by
- 263
- References
- 13
- Citations by year
- 2026: 6 · 2025: 13 · 2024: 16 · 2023: 17 · 2022: 22 · 2021: 13 · 2020: 28 · 2019: 18 · 2018: 14 · 2017: 13 · 2016: 6 · 2015: 13 · 2014: 11 · 2013: 11 · 2012: 5
- FWCI
- 3.54
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Science of The Total Environment (publishedVersion)
- PubMed (publishedVersion)
- PolyU Institutional Research Archive (Hong Kong Polytechnic University) (submittedVersion)
- Funders
- University of Hong Kong
- Hong Kong Polytechnic University
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Physical Sciences › Environmental Science › Pollution › Energy and Environment Impacts
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Air Quality and Health Impacts
- Keywords
- indoor air quality, restaurants, cooking emissions, gas stoves, hot pot, dim sum, carbon monoxide, carbon dioxide, particulate matter, volatile organic compounds, Hong Kong
- MeSH terms
- Carbon Dioxide, Carbon Monoxide, Cooking, Environmental Monitoring, Hong Kong, Humans, Hydrocarbons, Organic Chemicals, Particle Size, Restaurants, Volatilization, Air Pollution, Indoor
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.