[1] Measurement of absolute oxygen levels in cells and tissues using oxygen sensors and 2-nitroimidazole EF5
Abstract
We have established basic methods, using quantitative measures of EF5 binding, to estimate the actual pO2 of cells and tissues. In situations where the tissue can be dissociated into single cells, or for cell cultures, we can measure the distribution of cellular binding rates using flow cytometry and these can be compared with cells treated under pO2S controlled by the spinner vial or thin-film methods in vitro. The flow cytometer is calibrated by staining V79 cells treated with EF5 under "standard" conditions. For intact tissues treated with EF5 in vivo, we need to correct for possible variations in drug exposure (AUC). Frozen sections are stained for EF5 binding and are analyzed by a sensitive (cooled) CCD camera with linear output vs fluorescence [figure: see text] input. The camera has very consistent sensitivity, but the entire optical system, including the camera, can be calibrated by an absolute fluorescence standard (dye in hemocytometer). This system can also be used to measure the fluorescence of the flow cytometer standards, providing a direct link between the two assays. We can measure the maximum binding rate using the tissue cube method, but need to assume an "average" oxygen dependence of binding for intact tissues. The best-fit approximation for existing data is an inverse relationship between binding and pO2, with binding decreasing 50-fold between 0.1 and 10% oxygen. Using these methods, we routinely estimate the minimum pO2 (maximum binding) in experimental rodent and human tumors. In normal tissue models, an excellent correlation is found between near-maximal binding (severe hypoxia) and apoptosis (heart infarct and ductus arteriosus). Some normal tissues (e.g., skeletal muscle) are refractory to both cellular disaggregation and cube calibration methods. To extend the tissue imaging measurements to a complete two- or three-dimensional analysis of the distribution of tissue pO2s requires a substantial additional investment of imaging methods, which are currently being implemented.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“the gut, which is known to be relatively hypoxic under physiologic conditions (Koch, 2002)”
From Control of TH17/Treg Balance by Hypoxia-Inducible Factor 1 (2011) · cites this paper as Koch, 2002
In the citing paper
“the lamina propria of the gut, which, as indicated above (Koch, 2002), is relatively hypoxic”
From Control of TH17/Treg Balance by Hypoxia-Inducible Factor 1 (2011) · cites this paper as Koch, 2002
Citations
Cites
Hypoxia-mediated selection of cells with diminished apoptotic potential in solid tumours
Graeber, T. G., Osmanian, C., Jacks, T., Housman, D. E., Koch, C. J., Lowe, S. W., & Giaccia, A. J. (1996) · Nature · doi:10.1038/379088a0 · Cited by 2,300
Self-citation(1996) · PubMed · Cited by 1,188
Nordsmark, M., Overgaard, M., & Overgaard, J. (1996) · Radiotherapy and Oncology · doi:10.1016/s0167-8140(96)91811-3 · Cited by 942
Intratumoral pO2 predicts survival in advanced cancer of the uterine cervix
Höckel, M., Knoop, C., Schlenger, K., Vorndran, B., Bauβnann, E., Mitze, M., Knapstein, P. G., & Vaupel, P. (1993) · Radiotherapy and Oncology · doi:10.1016/0167-8140(93)90025-4 · Cited by 809
Gatenby, R. A., Kessler, H. B., Rosenblum, J. S., Coia, L. R., Moldofsky, P. J., Hartz, W. H., & Broder, G. J. (1988) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(88)90002-8 · Cited by 798
Moulder, J. E., & Rockwell, S. (1984) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(84)90301-8 · Cited by 606
Oxygenation predicts radiation response and survival in patients with cervix cancer
Fyles, A., Milosevic, M., Wong, R. K. W., Kavanagh, M.-C., Pintilie, M., Sun, A. Y., Chapman, W. C., Levin, W., Manchul, L., Keane, T. J., et al. (1998) · Radiotherapy and Oncology · doi:10.1016/s0167-8140(98)00044-9 · Cited by 603
23 Genetic instability induced by the tumor microenvironment
Glazer, P. M., Reynolds, T. Y., & Rockwell, S. (1997) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(97)80581-0 · Cited by 429
Bialik, S., Geenen, D. L., Sasson, I. E., Cheng, R., Horner, J. W., Evans, S. M., Lord, E. M., Koch, C. J., & Kitsis, R. N. (1997) · Journal of Clinical Investigation · doi:10.1172/jci119656 · Cited by 375
Self-citationLi, C., Shan, S., Huang, Q., Braun, R. D., Lanzen, J. L., Hu, K., Lin, P. C., & Dewhirst, M. W. (2000) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/92.2.143 · Cited by 331
Research works printed but not linked: 16
- Brizel, 1996, Cancer Res, 56, 941
- Reynolds, 1990, Cancer Res, 56, 5754
- Young, 1988, 85, 9533
- Clark, 1956, Trans. Am. Soc. Artif. Int. Organs, 2, 41
- Chapman, 1983, Cancer Res, 43, 1523
- Taylor, 1978, Cancer Res, 38, 2745
- Varghese, 1976, Cancer Res, 36, 3761
- Franko, 1987, Cancer Res, 47, 5367
- Evans, 1996, Cancer Res, 56, 405
- Lord, 1993, Cancer Res, 53, 5271
- Laughlin, 1996, J. Pharmacol. Exp. Ther, 277, 1049
- Evans, 2000, Cancer Res, 60, 2018
- Rasey, 1999, J. Nucl. Med, 40, 1072
- Busch, 2000, Cancer Res, 60, 2636
- Wiebe, 1996, Q. J. Nucl. Med, 40, 270
- Evans, 1999, J. Nucl. Med, 41, 327
Cited by
Sorted by citations
Control of TH17/Treg Balance by Hypoxia-Inducible Factor 1
Dang, E. V., Barbi, J., Yang, H.-Y., Jinasena, D., Yu, H., Zheng, Y., Bordman, Z., Fu, J., Kim, Y., Yen, H.-R., et al. (2011) · Cell · doi:10.1016/j.cell.2011.07.033 · Cited by 1,595
Cycling hypoxia and free radicals regulate angiogenesis and radiotherapy response
Dewhirst, M. W., Cao, Y., & Moeller, B. (2008) · Nature Reviews Cancer · doi:10.1038/nrc2397 · Cited by 1,022
Tatum, J. L. (2006) · International Journal of Radiation Biology · doi:10.1080/09553000601002324 · Cited by 626
XBP1 Is Essential for Survival under Hypoxic Conditions and Is Required for Tumor Growth
Romero‐Ramírez, L., Cao, H., Nelson, D. W., Hammond, E. M., Lee, A., Yoshida, H., Mori, K., Glimcher, L. H., Denko, N. C., Giaccia, A. J., et al. (2004) · Cancer Research · doi:10.1158/0008-5472.can-04-1606 · Cited by 587
Sakadžić, S., Roussakis, E., Yaseen, M. A., Mandeville, E. T., Srinivasan, V. J., Arai, K., Ruvinskaya, S., Devor, A., Lo, E. H., Vinogradov, S. A., et al. (2010) · Nature Methods · doi:10.1038/nmeth.1490 · Cited by 454
Metadata
- Authors
- Koch, C. J.
- Affiliations
- University of Pennsylvania (US)
- Corresponding author
- Koch, Cameron J.
- Venue
- Methods in Enzymology
- Publisher
- Elsevier
- Published
- 2002
- Volume
- 352
- Pages
- 3-31
- ISSN
- 0076-6879 (ISSN-L)
- OpenAlex
- W1554643012
- Cited by
- 207
- References
- 78
- Citations by year
- 2026: 4 · 2025: 5 · 2024: 3 · 2023: 8 · 2022: 6 · 2021: 5 · 2020: 7 · 2019: 8 · 2018: 8 · 2017: 4 · 2016: 13 · 2015: 10 · 2014: 10 · 2013: 6 · 2012: 7
- FWCI
- 25.02
- Type
- book chapter
- Language
- en
- Open access
- closed
- Locations
- Methods in enzymology on CD-ROM/Methods in enzymology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Cancer Research › Cancer, Hypoxia, and Metabolism
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Keywords
- EF5, 2-nitroimidazole, tissue oxygenation, oxygen sensors, hypoxia, apoptosis, flow cytometry, tissue dissociation, fluorescence imaging, tumor oxygenation, V79 cells, ductus arteriosus, skeletal muscle
- MeSH terms
- Animals, Hypoxia, Biochemistry, Flow Cytometry, Fluorocarbons, Humans, Hydrocarbons, Fluorinated, Immunohistochemistry, Neoplasms, Oxygen, Pressure, Time Factors, Etanidazole, Mice
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review