Control of urinary bladder function with devices: successes and failures

Gaunt, Robert A., Prochazka, Arthur · 2006 · Progress in Brain Research

The DOI matches its Crossref record; 197 of the 197 references it cites were found in a registry or an index.

Abstract

The management of urinary tract dysfunction is crucial for the health and well-being of people with spinal cord injury. Devices, specifically catheters, play an important role in the daily regime of bladder management for most people with spinal cord injury. However, the high incidence of complications associated with the use of catheters, and the fact that the spinal segments involved in lower urinary tract control remain intact in most cord-injured people, continue to motivate research into devices that could harness the nervous system to provide greater control over lower urinary tract function. Mechanical devices discussed in this review include catheters, artificial urethral sphincters, urethral stents and intraurethral pumps. Additionally, many attempts to restore control of the lower urinary tract with electrical stimulation have been made. Stimulation sites have included: inside the bladder, bladder wall, thigh, pelvic floor, dorsal penile nerve, pelvic nerve, tibial nerve, sacral roots, sacral nerves and spinal cord. Catheters and sacral root stimulators are two techniques whose efficacy is well established. Some approaches have proven less successful and others are still in the development stage. Modifications to sacral root stimulation including posterior root stimulation, anodal blockade and high-frequency blockade as well as new techniques including intraspinal microstimulation, urethral afferent stimulation and injectable microstimulators are also discussed. No…

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0079-6123(05)52011-9

Cites

197 of 197 references verified0 citation errors · 0 not checkable

Statistics

Figures

Image 1
From the PDF
Fig. 1 The In-Flow™ intraurethral pump. (A) Photograph showing the unfolded petals that secure the device in the urethral and prevent migration. (B) Diagram showing the placement of the device in the urethra. Adapted from (Madjar et al., 1999; Schurch et al., 1999).
Fig. 1 The In-Flow™ intraurethral pump. (A) Photograph showing the unfolded petals that secure the device in the urethral and prevent migration. (B) Diagram showing the placement of the device in the urethra. Adapted from (Madjar et al., 1999; Schurch et al., 1999).From the PDF
Fig. 2 Electrode locations for controlling the lower urinary tract. The locations are numbered primarily by the order in which they are discussed in the text. The location for a posterior rhizotomy is also indicated. (A) Intravesical, (B) Bladder wall, (C) Thigh, (D) Pelvic floor, (E) Dorsal penile nerve, (F) Tibial nerve, (G) Pelvic nerve, (H) Intradural sacral anterior root, (I) Extradural mixed sacral root, (J) Intradural sacral posterior root, (K) Sacral nerve, (L) Spinal cord, (M) Intraurethral, (N) Pudendal nerve, (O) Sacrum.
Fig. 2 Electrode locations for controlling the lower urinary tract. The locations are numbered primarily by the order in which they are discussed in the text. The location for a posterior rhizotomy is also indicated. (A) Intravesical, (B) Bladder wall, (C) Thigh, (D) Pelvic floor, (E) Dorsal penile nerve, (F) Tibial nerve, (G) Pelvic nerve, (H) Intradural sacral anterior root, (I) Extradural mixed sacral root, (J) Intradural sacral posterior root, (K) Sacral nerve, (L) Spinal cord, (M) Intraurethral, (N) Pudendal nerve, (O) Sacrum.From the PDF
Fig. 3 The bladder wall stimulator used by Magasi and Simon (1986). (A) The intended positioning of electrodes on the bladder. (B) Stimulator implanted in a patient. The patient had just used her stimulator to empty her bladder. Adapted from (Magasi and Simon, 1986).
Fig. 3 The bladder wall stimulator used by Magasi and Simon (1986). (A) The intended positioning of electrodes on the bladder. (B) Stimulator implanted in a patient. The patient had just used her stimulator to empty her bladder. Adapted from (Magasi and Simon, 1986).From the PDF
Fig. 4 Bladder pressure recording with and without stimulation during provocation of the bladder with rapid infusions of saline. Reproducible reflexive bladder contractions were caused by rapid infusions of 60 ml of saline (C and D) and were abolished by withdrawal of the saline. Further provocations (E and F) resulted in small reflexive bladder contractions that were immediately abolished by stimulation of the dorsal penile nerve. During F and G, bladder pressure increases are hyperreflexive contractions caused by the high volume. The two stimulation periods shown by open arrows at the onset of termination of G indicate patient-initiated stimulation in response to sensation of bladder fullness. These suppressions of reflexive bladder contractions were better than the previous ones. Without stimulation, bladder contractions are not suppressed (H). (Lee and Creasey, 2002).
Fig. 4 Bladder pressure recording with and without stimulation during provocation of the bladder with rapid infusions of saline. Reproducible reflexive bladder contractions were caused by rapid infusions of 60 ml of saline (C and D) and were abolished by withdrawal of the saline. Further provocations (E and F) resulted in small reflexive bladder contractions that were immediately abolished by stimulation of the dorsal penile nerve. During F and G, bladder pressure increases are hyperreflexive contractions caused by the high volume. The two stimulation periods shown by open arrows at the onset of termination of G indicate patient-initiated stimulation in response to sensation of bladder fullness. These suppressions of reflexive bladder contractions were better than the previous ones. Without stimulation, bladder contractions are not suppressed (H). (Lee and Creasey, 2002).From the PDF
Fig. 5 The components of the Finetech-Brindley sacral anterior root stimulator. (A) Intradural electrodes and leads. (B) Extradural electrodes and leads. (C) 2 and 3 channel implantable receiver blocks. These components are implant subcutaneously and connect to the electrode leads. (D) The external components of the device including the stimulator and transmission block that is placed on the skin over the receiver block. Adapted from (Egon et al., 1998).
Fig. 5 The components of the Finetech-Brindley sacral anterior root stimulator. (A) Intradural electrodes and leads. (B) Extradural electrodes and leads. (C) 2 and 3 channel implantable receiver blocks. These components are implant subcutaneously and connect to the electrode leads. (D) The external components of the device including the stimulator and transmission block that is placed on the skin over the receiver block. Adapted from (Egon et al., 1998).From the PDF
Fig. 6 Urine flow rate in a patient voiding his bladder using the poststimulus voiding technique. During stimulation, the flow rate drops to nearly zero as contraction of the sphincter occludes the urethra. Adapted from (Brindley et al., 1982).
Fig. 6 Urine flow rate in a patient voiding his bladder using the poststimulus voiding technique. During stimulation, the flow rate drops to nearly zero as contraction of the sphincter occludes the urethra. Adapted from (Brindley et al., 1982).From the PDF
Image 8
From the PDF
Fig. 8 Diagram showing the location of the penetrating electrodes implanted into the spinal cord. (Nashold et al., 1972).
Fig. 8 Diagram showing the location of the penetrating electrodes implanted into the spinal cord. (Nashold et al., 1972).From the PDF
Fig. 9 Electrical current under the anode hyperpolarizes the membrane of large fibers at lower stimulation amplitudes than smaller fibers. This section of hyperpolarized membrane blocks the transmission of action potentials generated at the cathode preventing activation of the sphincter while allowing activation of the bladder. (Rijkhoff et al., 1997a).
Fig. 9 Electrical current under the anode hyperpolarizes the membrane of large fibers at lower stimulation amplitudes than smaller fibers. This section of hyperpolarized membrane blocks the transmission of action potentials generated at the cathode preventing activation of the sphincter while allowing activation of the bladder. (Rijkhoff et al., 1997a).From the PDF
Fig. 10 High-frequency block of large fibers allowing selective activation of the bladder. (A) High-frequency, low-amplitude pulses superimposed on low-frequency, high-amplitude pulses. LFA - low-frequency amplitude, LFP - low-frequency period, LFW - low-frequency pulse width, HFA high-frequency amplitude, HFP - high-frequency period, HFW - highfrequency pulse width. (B) Reduction in intraurethral pressure and sphincter EMG while maintaining bladder pressure when the selective stimulation (high-frequency, low-amplitude) waveform is utilized. Adapted from (Boyer et al., 2000).
Fig. 10 High-frequency block of large fibers allowing selective activation of the bladder. (A) High-frequency, low-amplitude pulses superimposed on low-frequency, high-amplitude pulses. LFA - low-frequency amplitude, LFP - low-frequency period, LFW - low-frequency pulse width, HFA high-frequency amplitude, HFP - high-frequency period, HFW - highfrequency pulse width. (B) Reduction in intraurethral pressure and sphincter EMG while maintaining bladder pressure when the selective stimulation (high-frequency, low-amplitude) waveform is utilized. Adapted from (Boyer et al., 2000).From the PDF
photolithographic processes (see Figure 11B). Microwirebased electrodes use iridium and platinum-iridium alloy wires 20 - 30 µm in diameter with 20 - 100 µm long exposed tips resulting in geometric electrode surface areas of 1,600 - 10,000 µm 2 (Mushahwar et al., 2000). Silicon substrate microelectrodes used for chronic ISMS implants can have multiple stimulation sites at various depths per penetrating shank with electrode surface areas around 2000 µm 2 (McCreery et al., 2004). These electrode surface areas are 50 - 300 times smaller than the smallest electrodes used in the first spinal cord stimulation experiments (Nashold et al., 1971; Jonas et al., 1975) and allow selective stimulation of the sacral parasympathetic nucleus without concomitant sphincter activation (Carter et al., 1995; Grill et al., 1999). Although electrode arrays can cause inflammatory reactions, glial scarring and neural death around the implantation site, this can be minimized (McCreery et al., 2004) and would presumably be just as safe or safer in long term use as the larger electrodes implanted in humans (Nashold et al., 1981). Fig. 11. Electrode designs and target locations (in the cat) for intraspinal microstimulation. (A) Microwire electrode array. (B) Multi-site penetrating silicon electrode array. (C) Electrode targets in the cat sacral spinal cord. Electrical stimulation in the dorsal gray commisure, which contains interneurons with inhibitory projections to sphincter motoneurons, can elicit relaxation of the external urethral sphincter. Electrical stimulation
photolithographic processes (see Figure 11B). Microwirebased electrodes use iridium and platinum-iridium alloy wires 20 - 30 µm in diameter with 20 - 100 µm long exposed tips resulting in geometric electrode surface areas of 1,600 - 10,000 µm 2 (Mushahwar et al., 2000). Silicon substrate microelectrodes used for chronic ISMS implants can have multiple stimulation sites at various depths per penetrating shank with electrode surface areas around 2000 µm 2 (McCreery et al., 2004). These electrode surface areas are 50 - 300 times smaller than the smallest electrodes used in the first spinal cord stimulation experiments (Nashold et al., 1971; Jonas et al., 1975) and allow selective stimulation of the sacral parasympathetic nucleus without concomitant sphincter activation (Carter et al., 1995; Grill et al., 1999). Although electrode arrays can cause inflammatory reactions, glial scarring and neural death around the implantation site, this can be minimized (McCreery et al., 2004) and would presumably be just as safe or safer in long term use as the larger electrodes implanted in humans (Nashold et al., 1981). Fig. 11. Electrode designs and target locations (in the cat) for intraspinal microstimulation. (A) Microwire electrode array. (B) Multi-site penetrating silicon electrode array. (C) Electrode targets in the cat sacral spinal cord. Electrical stimulation in the dorsal gray commisure, which contains interneurons with inhibitory projections to sphincter motoneurons, can elicit relaxation of the external urethral sphincter. Electrical stimulationFrom the PDF
Image 13
From the PDF

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 197 references

Research works printed but not linked: 4

  1. Benda, B.J., Houdayer, T., Creasey, G., Betz, R.R., Smith, B.T., Johnston, T.E., Davis, R. (2003) The Praxis FES system and bladder/bowel management in patients with spinal cord injury. In: Meadows, P. (Ed.). IFESS Conference Proceedings. Brisbane, Australia.
  2. Prochazka, A., Gaunt, R.G., Mushahwar, V., Downie, J.W., Shefchyk, S.J. (2003a) Functional microstimulation of the lumbosacral spinal cord: Quarterly Report #6. NIH-NINDS contract N01-NS-2-2342.
  3. Prochazka, A., Mushahwar, V., Downie, J.W., Shefchyk, S.J. (2002a) Functional microstimulation of the lumbosacral spinal cord: Quarterly Report #1. NIH-NINDS contract N01-NS-2-2342.
  4. Prochazka, A., Mushahwar, V., Downie, J.W., Shefchyk, S.J., Gaunt, R.G. (2003b) Functional microstimulation of the lumbosacral spinal cord: Quarterly Report #5. NIH-NINDS contract N01-NS-2-2342.

Cited by

Items 101–121 of 121

Metadata

Authors
Gaunt, R. A., & Prochazka, A.
Affiliations
University of Alberta (CA)
Venue
Progress in Brain Research
Publisher
Elsevier
Published
2006
Volume
152
Pages
163-194
ISSN
0079-6123 (ISSN-L)
OpenAlex
W1480874625
Cited by
105
References
197
Citations by year
2025: 2 · 2024: 4 · 2023: 5 · 2022: 4 · 2021: 1 · 2020: 5 · 2019: 5 · 2018: 9 · 2017: 7 · 2016: 3 · 2015: 10 · 2014: 9 · 2013: 5 · 2012: 2
FWCI
13.77
Type
book chapter
Language
en
Open access
closed
Locations
  • Progress in brain research (publishedVersion)
  • PubMed (publishedVersion)
Funders
National Institute of Neurological Disorders and Stroke (N01-NS-2-2342)
Topics
  • Health Sciences › Medicine › Urology › Urinary Bladder and Prostate Research
  • Health Sciences › Medicine › Clinical Neurology › Spinal Cord Injury Research
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
Keywords
bladder dysfunction, spinal cord injury, urinary catheter, artificial urethral sphincter, urethral stent, sacral root stimulation, sacral neuromodulation, electrical stimulation, intraspinal microstimulation
MeSH terms
Urinary Bladder, Catheterization, Electric Stimulation Therapy, Humans, Microelectrodes, Sacrum, Spinal Cord, Spinal Cord Injuries, Urination, Urination Disorders, Stents, Urinary Sphincter, Artificial, Treatment Outcome, Recovery of Function

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.