Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: a retrospective cohort study
Open accessThe DOI matches its Crossref record; 26 of the 28 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Although CT scans are very useful clinically, potential cancer risks exist from associated ionising radiation, in particular for children who are more radiosensitive than adults. We aimed to assess the excess risk of leukaemia and brain tumours after CT scans in a cohort of children and young adults. METHODS: In our retrospective cohort study, we included patients without previous cancer diagnoses who were first examined with CT in National Health Service (NHS) centres in England, Wales, or Scotland (Great Britain) between 1985 and 2002, when they were younger than 22 years of age. We obtained data for cancer incidence, mortality, and loss to follow-up from the NHS Central Registry from Jan 1, 1985, to Dec 31, 2008. We estimated absorbed brain and red bone marrow doses per CT scan in mGy and assessed excess incidence of leukaemia and brain tumours cancer with Poisson relative risk models. To avoid inclusion of CT scans related to cancer diagnosis, follow-up for leukaemia began 2 years after the first CT and for brain tumours 5 years after the first CT. FINDINGS: During follow-up, 74 of 178,604 patients were diagnosed with leukaemia and 135 of 176,587 patients were diagnosed with brain tumours. We noted a positive association between radiation dose from CT scans and leukaemia (excess relative risk [ERR] per mGy 0·036, 95% CI 0·005-0·120; p=0·0097) and brain tumours (0·023, 0·010-0·049; p<0·0001). Compared with patients who received a dose of less than 5 mGy, the relative risk of leukaemia for patients who received a cumulative dose of at least 30 mGy (mean dose 51·13 mGy) was 3·18 (95% CI 1·46-6·94) and the relative risk of brain cancer for patients who received a cumulative dose of 50-74 mGy (mean dose 60·42 mGy) was 2·82 (1·33-6·03). INTERPRETATION: Use of CT scans in children to deliver cumulative doses of about 50 mGy might almost triple the risk of leukaemia and doses of about 60 mGy might triple the risk of brain cancer. Because these cancers are relatively rare, the cumulative absolute risks are small: in the 10 years after the first scan for patients younger than 10 years, one excess case of leukaemia and one excess case of brain tumour per 10,000 head CT scans is estimated to occur. Nevertheless, although clinical benefits should outweigh the small absolute risks, radiation doses from CT scans ought to be kept as low as possible and alternative procedures, which do not involve ionising radiation, should be considered if appropriate. FUNDING: US National Cancer Institute and UK Department of Health.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures

Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“However, concerns regarding unnecessary exposure to ionizing radiation, with the risk for future cancer development, preclude recommendations for routine use.789,790”
From International Consensus Statement on Allergy and Rhinology: Allergic Rhinitis (2018) · cites this paper as [790]
The cited source says what the claim attributes to it.
In the citing paper
“Studies by Pearce et al. [67] and Sheppard et al. [68] showed the increased risk of leukaemia and brain tumuors from CT applications with a cumulative dose of 50–60 mGy.”
From Developments in diagnostic and surgical techniques in children with sagittal suture craniosynostosis: a systematic review spanning the last 30 years (2025) · cites this paper as [67]
The cited source says what the claim attributes to it.
In the citing paper
“There is an estimated risk of cancer which is attributed to the use of diagnostic X-rays due to the stochastic effects of the X-rays [3, 4].”
From Adult Computed Tomography examinations in Uganda: Towards determining the National Diagnostic Reference Levels (2022) · cites this paper as [4]
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“EPI-CT was designed to address previous methodological criticisms and limitations of similar studies12–16.”
From Risk of hematological malignancies from CT radiation exposure in children, adolescents and young adults (2023) · cites this paper as [12]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2005) · Statistics for Biology and Health · doi:10.1007/0-387-27255-0_9 · Cited by 20,133
Computed Tomography — An Increasing Source of Radiation Exposure
Brenner, D. J., & Hall, E. J. (2007) · New England Journal of Medicine · doi:10.1056/nejmra072149 · Cited by 8,748
Estimated Risks of Radiation-Induced Fatal Cancer from Pediatric CT
Brenner, D. J., Elliston, C. D., Hall, E. J., & Berdon, W. E. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.2.1760289 · Cited by 3,222
Health Risks from Exposure to Low Levels of Ionizing Radiation:: BEIR VII Phase 2
Earth, D. O. (2006) · CERN Document Server (European Organization for Nuclear Research) · Cited by 2,190
Projected Cancer Risks From Computed Tomographic Scans Performed in the United States in 2007
Berrington de González, A. (2009) · Archives of Internal Medicine · doi:10.1001/archinternmed.2009.440 · Cited by 1,888
Self-citationMeasurement error in nonlinear models: a modern perspective
Carroll, R. J. (2006) · Cited by 1,374
Preston, D. L., Kusumi, S., Tomonaga, M., Izumi, S., Ron, E., Kuramoto, A., Kamada, N., Dohy, H., Matsui, T., Nonaka, H., et al. (1994) · Radiation Research · doi:10.2307/3578893 · Cited by 803
Estimated Radiation Risks Potentially Associated with Full-Body CT Screening
Brenner, D. J., & Elliston, C. D. (2004) · Radiology · doi:10.1148/radiol.2323031095 · Cited by 685
Risk of cancer after low doses of ionising radiation: retrospective cohort study in 15 countries
Cardis, E., Vrijheid, M., Blettner, M., Gilbert, E., Hakama, M., Hill, C., Howe, G., Kaldor, J., Muirhead, C. R., Schubauer-Berigan, M., et al. (2005) · BMJ · doi:10.1136/bmj.38499.599861.e0 · Cited by 608
Self-citationThe Linear No-Threshold Relationship Is Inconsistent with Radiation Biologic and Experimental Data
Tubiana, M., Feinendegen, L. E., Yang, C., & Kaminski, J. M. (2009) · Radiology · doi:10.1148/radiol.2511080671 · Cited by 509
Cited by
Items 301–400 of 1,007
Age-related effects of X-ray irradiation on mouse hippocampus
Casciati, A., Dobos, K., Antonelli, F., Benedek, A., Kempf, S. J., Bellés, M., Balogh, A., Tanori, M., Heredia, L., Atkinson, M. J., et al. (2016) · Oncotarget · doi:10.18632/oncotarget.8575 · Cited by 72
Rigsby, C. K., McKenney, S. E., Hill, K. D., Chelliah, A., Einstein, A. J., Han, B. K., Robinson, J. D., Sammet, C. L., Slesnick, T. C., & Frush, D. P. (2018) · Pediatric Radiology · doi:10.1007/s00247-017-3991-x · Cited by 62
Use of CT for Head Trauma: 2007–2015
Burstein, B., Upton, J. E. M., Terra, H. F., & Neuman, M. I. (2018) · PEDIATRICS · doi:10.1542/peds.2018-0814 · Cited by 72
Understanding, justifying, and optimizing radiation exposure for CT imaging in nephrourology
Ferrero, A., Takahashi, N., Vrtiska, T. J., Krambeck, A. E., Lieske, J. C., & McCollough, C. H. (2019) · Nature Reviews Urology · doi:10.1038/s41585-019-0148-8 · Cited by 73
Kada, S. (2017) · Insights into Imaging · doi:10.1007/s13244-017-0569-y · Cited by 71
The Critical Role of Lumped Parameter Models in Patient-Specific Cardiovascular Simulations
Garber, L., Khodaei, S., & Keshavarz‐Motamed, Z. (2021) · Archives of Computational Methods in Engineering · doi:10.1007/s11831-021-09685-5 · Cited by 71
Triage tools for detecting cervical spine injury in pediatric trauma patients
Slaar, A., Fockens, M. M., Wang, J., Maas, M. M., Wilson, D. J., Goslings, J. C., Schep, N. W. L., & van Rijn, R. R. (2017) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011686.pub2 · Cited by 71
Matsunaga, Y., Chida, K., Kondo, Y., Kobayashi, K., Kobayashi, M., Minami, K., Suzuki, S., & Asada, Y. (2019) · The British Journal of Radiology · doi:10.1259/bjr.20180290 · Cited by 65
Isolated Loss of Consciousness in Children With Minor Blunt Head Trauma
Lee, L. K., Monroe, D. J., Bachman, M. C., Glass, T. F., Mahajan, P., Cooper, A., Stanley, R. M., Miskin, M. L., Dayan, P. S., Holmes, J. F., et al. (2014) · Archives of Pediatrics and Adolescent Medicine · doi:10.1001/jamapediatrics.2014.361 · Cited by 70
Starke, R. M., Yen, C. P., Chen, C., Ding, D., Mohila, C., Jensen, M. E., Kassell, N. F., & Sheehan, J. P. (2013) · World Neurosurgery · doi:10.1016/j.wneu.2013.02.008 · Cited by 70
Preoperative staging of non-small cell lung cancer: prospective comparison of PET/MR and PET/CT
Lee, S., Goo, J. M., Park, C. M., Yoon, S. H., Paeng, J. C., Cheon, G. J., Kim, Y. T., & Park, Y. S. (2016) · European Radiology · doi:10.1007/s00330-016-4255-0 · Cited by 70
Point-of-Care Ultrasound Integrated Into a Staged Diagnostic Algorithm for Pediatric Appendicitis
Doniger, S. J., & Kornblith, A. E. (2016) · Pediatric Emergency Care · doi:10.1097/pec.0000000000000773 · Cited by 70
Proton Beam Therapy for Pediatric Brain Tumor
Mizumoto, M., Oshiro, Y., Yamamoto, T., Kohzuki, H., & Sakurai, H. (2017) · Neurologia medico-chirurgica · doi:10.2176/nmc.ra.2017-0003 · Cited by 70
Berrington de Gonzalez, A., Daniels, R. D., Cardis, E., Cullings, H. M., Gilbert, E., Hauptmann, M., Kendall, G., Laurier, D., Linet, M. S., Little, M. P., et al. (2020) · JNCI Monographs · doi:10.1093/jncimonographs/lgaa009 · Cited by 61
Self-citationGatidis, S., Schmidt, H., Gücke, B., Bezrukov, I., Seitz, G., Ebinger, M., Reimold, M., Pfannenberg, C., Nikolaou, K., Schwenzer, N. F., et al. (2015) · Investigative Radiology · doi:10.1097/rli.0000000000000200 · Cited by 69
de Basea, M. B., Salotti, J. A., Pearce, M. S., Muchart, J., Riera, L., Barber, I., Pedraza, S., Pardina, M., Capdevila, A., Espinosa, A., et al. (2015) · Pediatric Radiology · doi:10.1007/s00247-015-3434-5 · Cited by 69
Self-citationAubert, B., Vergari, C., Ilharreborde, B., Courvoisier, A., & Skalli, W. (2014) · Computer Methods in Biomechanics and Biomedical Engineering Imaging & Visualization · doi:10.1080/21681163.2014.913990 · Cited by 69
Surendran, A., Mori, A., Varma, D., & Gruen, R. L. (2014) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/ta.0000000000000178 · Cited by 69
Forensic age estimation from the clavicle using 1.0T MRI—Preliminary results
Larsen, S. T., Jensen, K. E., Villa, C., & Lynnerup, N. (2013) · Forensic Science International · doi:10.1016/j.forsciint.2013.10.027 · Cited by 69
Hybrid FDG-PET/MR compared to FDG-PET/CT in adult lymphoma patients
Atkinson, W. L., Catana, C., Abramson, J. S., Arabasz, G., McDermott, S., Catalano, O. A., Muse, V. V., Blake, M. A., Barnes, J. A., Shelly, M. J., et al. (2016) · Abdominal Radiology · doi:10.1007/s00261-016-0638-6 · Cited by 69
Qin, N., Wang, Z., Liu, Q., Song, N., Wilson, C. L., Ehrhardt, M. J., Shelton, K., Easton, J. B., Mulder, H. L., Kennetz, D., et al. (2020) · Journal of Clinical Oncology · doi:10.1200/jco.19.02760 · Cited by 69
Half2Half: deep neural network based CT image denoising without independent reference data
Yuan, N., Zhou, J., & Qi, J. (2020) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aba939 · Cited by 68
HRCT and MRI of the lung in children with cystic fibrosis: Comparison of different scoring systems
Siléo, C., Corvol, H., Boëlle, P., Blondiaux, É., Clément, A., & Pointe, H. D. L. (2013) · Journal of Cystic Fibrosis · doi:10.1016/j.jcf.2013.09.003 · Cited by 68
Hess, C. B., Thompson, H. M., Benedict, S., Seibert, J. A., Wong, K., Vaughan, A. T., & Chen, A. (2016) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2015.12.372 · Cited by 68
Ionizing radiation exposure: hazards, prevention, and biomarker screening
Mu, H., Sun, J., Li, L., Yin, J., Hu, N., Zhao, W., Ding, D., & Yi, L. (2018) · Environmental Science and Pollution Research · doi:10.1007/s11356-018-2097-9 · Cited by 68
Chronic non-bacterial osteomyelitis: a comparative study between children and adults
Skrabl‐Baumgartner, A., Singer, P., Greimel, T., Gorkiewicz, G., & Hermann, J. (2019) · Pediatric Rheumatology · doi:10.1186/s12969-019-0353-2 · Cited by 68
Holmes, J. F., Yen, K., Ugalde, I. T., Ishimine, P. T., Chaudhari, P. P., Atigapramoj, N. S., Badawy, M. K., McCarten-Gibbs, K. A., Nielsen, D. S., Sage, A. C., et al. (2024) · The Lancet Child & Adolescent Health · doi:10.1016/s2352-4642(24)00029-4 · Cited by 67
Taylor, A. M., Nigrovic, L. E., Saillant, M. L., Trudell, E. K., Proctor, M. R., Modest, J. R., & Vernacchio, L. (2015) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2015.05.036 · Cited by 67
Optimizing Diagnostic Imaging in the Emergency Department
Mills, A. M., Raja, A. S., & Marín, J. R. (2015) · Academic Emergency Medicine · doi:10.1111/acem.12640 · Cited by 68
Yue, E. L., Meckler, G. D., Fleischman, R. J., Selden, N. R. W., Bardo, D. M. E., O'Connor, A. K. C., Vu, E. T., Fu, R. F., & Spiro, D. M. (2015) · Journal of Neurosurgery Pediatrics · doi:10.3171/2014.9.peds14207 · Cited by 67
Järvinen, H., Seuri, R., Kortesniemi, M., Lajunen, A., Hallinen, E., Savikurki-Heikkilä, P., Laarne, P., Perhomaa, M., & Tyrväinen, E. (2015) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncv044 · Cited by 56
Sin, H., Wong, C.-S., Huang, B., Ka-ling, Y., Wong, W., & Chu, Y. C. (2012) · Journal of Medical Imaging and Radiation Oncology · doi:10.1111/j.1754-9485.2012.02471.x · Cited by 67
Childhood CT scans and cancer risk: impact of predisposing factors for cancer on the risk estimates
Journy, N., Roué, T., Cardis, E., Pointe, H. D. L., Brisse, H. J., Chateil, J., Laurier, D., & Bernier, M. (2016) · Journal of Radiological Protection · doi:10.1088/0952-4746/36/1/n1 · Cited by 67
Radiation Exposure and Mortality from Cardiovascular Disease and Cancer in Early NASA Astronauts
Elgart, S. R., Little, M. P., Chappell, L. J., Milder, C. M., Shavers, M. R., Huff, J. L., & Patel, Z. S. (2018) · Scientific Reports · doi:10.1038/s41598-018-25467-9 · Cited by 66
Self-citationMicro and nano Bi2O3 filled epoxy composites: Thermal, mechanical and γ-ray attenuation properties
Muthamma, M. V., Prabhu, S., Bubbly, S. G., & Gudennavar, S. B. (2021) · Applied Radiation and Isotopes · doi:10.1016/j.apradiso.2021.109780 · Cited by 66
Wirsching, H., & Weller, M. (2016) · Springer eBooks · doi:10.1007/978-3-319-49864-5_18 · Cited by 68
A Cervical Spine Injury Prediction Rule for Children after Blunt Trauma
Leonard, J. C., Harding, M. L., Cook, L. J., Leonard, J. R., Adelgais, K., Ahmad, F. A., Browne, L. R., Burger, R. K., Chaudhari, P. P., Corwin, D. J., et al. (2023) · The Lancet Child & Adolescent Health · doi:10.1016/s2352-4642(24)00104-4 · Cited by 66
Bosch de Basea, M., Pearce, M. S., Kesminiene, A., Bernier, M.-O., Dabin, J., Engels, H., Hauptmann, M., Krille, L., Meulepas, J. M., Struelens, L., et al. (2015) · Journal of Radiological Protection · doi:10.1088/0952-4746/35/3/611 · Cited by 56
Self-citationJadhav, S. P., Golriz, F., Atweh, L. A., Zhang, W., & Krishnamurthy, R. (2015) · American Journal of Roentgenology · doi:10.2214/ajr.14.12846 · Cited by 63
Beyond the bombs: cancer risks of low-dose medical radiation
Einstein, A. J. (2012) · The Lancet · doi:10.1016/s0140-6736(12)60897-6 · Cited by 66
Characterization of the nanoDot OSLD dosimeter in CT
Scarboro, S. B., CODY, D. D., Alvarez, P. E., Followill, D. S., Court, L. E., Stingo, F. C., Zhang, D., McNitt‐Gray, M. F., & Kry, S. F. (2015) · Medical Physics · doi:10.1118/1.4914398 · Cited by 66
Foley, S. J., Evanoff, M. G., & Rainford, L. A. (2013) · Insights into Imaging · doi:10.1007/s13244-013-0282-4 · Cited by 66
Nyilas, S., Bauman, G., Pusterla, O., Sommer, G., Singer, F., Stranzinger, E., Heyer, C., Ramsey, K., Schlegtendal, A., Benzrath, S., et al. (2018) · Annals of the American Thoracic Society · doi:10.1513/annalsats.201712-967oc · Cited by 66
Lansdown, D. A., Cvetanovich, G. L., Verma, N. N., Cole, B. J., Bach, B. R., Nicholson, G. P., Romeo, A. A., Dawe, R. J., & Yanke, A. B. (2019) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/j.arthro.2018.10.119 · Cited by 66
PET/MR in oncology: an introduction with focus on MR and future perspectives for hybrid imaging.
Balyasnikova, S., Löfgren, J., de Nijs, R., Zamogilnaya, Y., Højgaard, L., & Fischer, B. M. (2012) · Europe PMC (PubMed Central) · Cited by 65
Ilharreborde, B., Sebag, G. H., Skalli, W., & Mazda, K. (2013) · European Spine Journal · doi:10.1007/s00586-013-2776-7 · Cited by 65
ACR Appropriateness Criteria Head Trauma—Child
Ryan, M. E., Palasis, S., Saigal, G. M., Singer, A. D., Karmazyn, B. W., Dempsey, M., Dillman, J. R., Dory, C. E., Garber, M. D., Hayes, L. L., et al. (2014) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2014.07.017 · Cited by 65
Image Gently: A Campaign to Reduce Children's and Adolescents' Risk for Cancer During Adulthood
Applegate, K. E., & Cost, N. G. (2013) · Journal of Adolescent Health · doi:10.1016/j.jadohealth.2013.03.006 · Cited by 65
Diagnostic ionizing radiation exposure in premature patients
Scott, M. V., Fujii, A. M., Behrman, R. H., & Dillon, J. E. (2014) · Journal of Perinatology · doi:10.1038/jp.2013.141 · Cited by 65
Markic, G., Müller, L., Patcas, R., Roos, M., Lochbühler, N., Peltomäki, T., Karlo, C. A., Ullrich, O., & Kellenberger, C. J. (2014) · European Journal of Orthodontics · doi:10.1093/ejo/cju008 · Cited by 65
Journy, N., Lee, C., Harbron, R. W., McHugh, K., Pearce, M. S., & de González, A. B. (2016) · British Journal of Cancer · doi:10.1038/bjc.2016.351 · Cited by 65
Self-citationChamard, É., & Lichtenstein, J. D. (2018) · Brain Injury · doi:10.1080/02699052.2018.1463106 · Cited by 65
Bos, D., Yu, S., Luong, J., Chu, P., Wang, Y., Einstein, A. J., Starkey, J., Delman, B. N., Duong, P.-A. T., Das, M., et al. (2022) · European Radiology · doi:10.1007/s00330-021-08266-1 · Cited by 64
Nagayama, Y., Goto, M., Sakabe, D., Emoto, T., Shigematsu, S., Oda, S., Tanoue, S., Kidoh, M., Nakaura, T., Funama, Y., et al. (2022) · American Journal of Roentgenology · doi:10.2214/ajr.21.27255 · Cited by 64
Leung, V. J., Sastry, A. S., Woo, T. D., & Jones, H. R. (2015) · Clinical Radiology · doi:10.1016/j.crad.2015.05.014 · Cited by 64
Meulepas, J. M., Ronckers, C. M., Smets, A. M. J. B., Nievelstein, R. A. J., Jahnen, A., Lee, C., Kieft, M., Laméris, J. S., van Herk, M., Greuter, M. J. W., et al. (2014) · European Journal of Epidemiology · doi:10.1007/s10654-014-9900-9 · Cited by 64
Self-citationKaasalainen, T. T., Palmu, K., Lampinen, A., & Kortesniemi, M. (2013) · Pediatric Radiology · doi:10.1007/s00247-012-2611-z · Cited by 67
Pathology of asymptomatic, prenatally diagnosed cystic lung malformations
Durell, J., Thakkar, H., Gould, S. J., Fowler, D. J., & Lakhoo, K. (2015) · Journal of Pediatric Surgery · doi:10.1016/j.jpedsurg.2015.10.061 · Cited by 64
Fletcher, J. G., Yu, L., Li, Z., Manduca, A., Blezek, D. J., Hough, D. M., Venkatesh, S. K., Brickner, G. C., Cernigliaro, J. C., Hara, A. K., et al. (2015) · Radiology · doi:10.1148/radiol.2015141991 · Cited by 59
Smith, B. R., Ashton, K. M., Brodbelt, A. R., Dawson, T., Jenkinson, M. D., Hunt, N. T., Palmer, D. S., & Baker, M. J. (2016) · The Analyst · doi:10.1039/c5an02452h · Cited by 64
McGuigan, M. B., Duncan, H. F., & Horner, K. (2018) · SWISS DENTAL JOURNAL SSO – Science and Clinical Topics · doi:10.61872/sdj-2018-04-395 · Cited by 64
Biological effects of low-dose radiation from computed tomography scanning
Ma, S., Kong, B., Liu, B., & Liu, X. (2012) · International Journal of Radiation Biology · doi:10.3109/09553002.2013.756595 · Cited by 63
Kempf, S. J., Moertl, S., Sepe, S., von Toerne, C., Hauck, S. M., Atkinson, M. J., Mastroberardino, P. G., & Tapio, S. (2015) · Journal of Proteome Research · doi:10.1021/acs.jproteome.5b00114 · Cited by 60
A novel biomarker panel to rule out acute appendicitis in pediatric patients with abdominal pain
Huckins, D. S., Simon, H. K., Copeland, K. A. F., Spiro, D. M., Gogain, J., & Wandell, M. (2013) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2013.06.016 · Cited by 63
Demoury, C., Marquant, F., Ielsch, G., Goujon, S., Debayle, C., Faure, L., Coste, A., Laurent, O., Guillevic, J., Laurier, D., et al. (2016) · Environmental Health Perspectives · doi:10.1289/ehp296 · Cited by 63
Linet, M. S., Kitahara, C. M., Ntowe, E., Kleinerman, R. A., Gilbert, E. S., Naito, N., Lipner, R. S., Miller, D. L., de González, A. B., & For the Multi-Specialty Occupational Health Group (2017) · Radiology · doi:10.1148/radiol.2017161306 · Cited by 65
Estimation of the effects of medical diagnostic radiation exposure based on DNA damage
Shi, L., & Tashiro, S. (2018) · Journal of Radiation Research · doi:10.1093/jrr/rry006 · Cited by 63
Medical imaging dose optimisation from ground up: expert opinion of an international summit
Samei, E., Järvinen, H., Kortesniemi, M., Simantirakis, G., Goh, C. X. Y., Wallace, A. B., Vano, E., Bejan, A., Rehani, M. M., & Vassileva, J. (2018) · Journal of Radiological Protection · doi:10.1088/1361-6498/aac575 · Cited by 63
Leukemia Risk in a Cohort of 3.9 Million Children with and without Down Syndrome
Marlow, E. C., Ducore, J. M., Kwan, M. L., Cheng, S. Y., Bowles, E. J. A., Greenlee, R. T., Pole, J. D., Rahm, A. K., Stout, N. K., Weinmann, S. A., et al. (2021) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2021.03.001 · Cited by 64
Clinical Prediction Scores for Pediatric Appendicitis
Gudjonsdottir, J., Marklund, E., Hagander, L. E., & Salö, M. (2020) · European Journal of Pediatric Surgery · doi:10.1055/s-0040-1710534 · Cited by 62
Baldini, B., Cavagnetto, D., Baselli, G., Sforza, C., & Tartaglia, G. M. (2022) · BMC Oral Health · doi:10.1186/s12903-022-02131-3 · Cited by 62
Hall, M. K., Spiro, D. M., Sabbaj, A., Moore, C. L., Hopkins, K. L., & Meckler, G. D. (2013) · Child s Nervous System · doi:10.1007/s00381-013-2172-y · Cited by 62
Hepatic pseudoaneurysm after traumatic liver injury; is CT follow-up warranted?
Østerballe, L., Helgstrand, F., Axelsen, T., Hillingsø, J., & Svendsen, L. B. (2014) · Journal of Trauma Management & Outcomes · doi:10.1186/1752-2897-8-18 · Cited by 62
Simultaneous PET/MRI vs. PET/CT in oncology. A systematic review
Riola-Parada, C., García‐Cañamaque, L., Pérez-Dueñas, V., Garcerant-Tafur, M., & Carreras-Delgado, J. L. (2016) · Revista Española de Medicina Nuclear e Imagen Molecular (English Edition) · doi:10.1016/j.remnie.2016.06.006 · Cited by 62
Jensen, R. T., & Norton, J. A. (2017) · Pancreas · doi:10.1097/mpa.0000000000000825 · Cited by 62
Can common serum biomarkers predict complicated appendicitis in children?
Zani, A., Teague, W. J., Clarke, S. A., Haddad, M. J., Khurana, S., Tsang, T., & Nataraja, R. M. (2017) · Pediatric Surgery International · doi:10.1007/s00383-017-4088-1 · Cited by 62
Markar, S. R., Vidal‐Diez, A., Sounderajah, V., Mackenzie, H., Hanna, G. B., THOMPSON, M. M., Holt, P., Lagergren, J., & Karthikesalingam, A. (2018) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2018.09.058 · Cited by 62
Trends in Medical Imaging During Pregnancy in the United States and Ontario, Canada, 1996 to 2016
Kwan, M. L., Miglioretti, D. L., Marlow, E. C., Bowles, E. J. A., Weinmann, S. A., Cheng, S. Y., Deosaransingh, K. A., Chavan, P. P., Moy, L. M., Bolch, W. E., et al. (2019) · JAMA Network Open · doi:10.1001/jamanetworkopen.2019.7249 · Cited by 62
Park, S., Yoon, J. H., Joo, I., Yu, M. H., Kim, J. H., Park, J., Kim, S. W., Han, S., Ahn, C., Kim, J. H., et al. (2021) · European Radiology · doi:10.1007/s00330-021-08380-0 · Cited by 62
Chari, A., Czosnyka, M., Richards, H. K., Pickard, J. D., & Czosnyka, Z. H. (2014) · Journal of neurosurgery · doi:10.3171/2013.11.jns121895 · Cited by 61
Weiser, D. A., Kaste, S. C., Siegel, M. J., & Adamson, P. C. (2013) · Pediatric Blood & Cancer · doi:10.1002/pbc.24533 · Cited by 61
Chowdhry, R., Dangman, B. C., & PINHEIRO, J. M. B. (2015) · Journal of Perinatology · doi:10.1038/jp.2014.240 · Cited by 61
Pediatric Chest and Abdominopelvic CT: Organ Dose Estimation Based on 42 Patient Models
Tian, X., Li, X., Segars, W. P., Paulson, E. K., Frush, D. P., & Samei, E. (2013) · Radiology · doi:10.1148/radiol.13122617 · Cited by 61
Factors affecting patient movement and re-exposure in cone beam computed tomography examination
Spin‐Neto, R., Matzen, L. H., Schropp, L., Gotfredsen, E., & Wenzel, A. (2015) · Oral Surgery Oral Medicine Oral Pathology and Oral Radiology · doi:10.1016/j.oooo.2015.01.011 · Cited by 61
The use of CT-scan in foreign body aspiration in children: A 6 years' experience
Pitiot, V., Grall, M., Ploin, D., Truy, É., & Khalfallah, S. A. (2017) · International Journal of Pediatric Otorhinolaryngology · doi:10.1016/j.ijporl.2017.08.036 · Cited by 61
Tsapaki, V., Balter, S., Cousins, C., Holmberg, O., Miller, D. L., Miranda, P., Rehani, M. M., & Vano, E. (2018) · Physica Medica · doi:10.1016/j.ejmp.2018.06.634 · Cited by 61
Saarikko, A. M., Mellanen, E. H., Kuusela, L., Leikola, J. P., Karppinen, A., Autti, T. H., Virtanen, P. L. J., & Brandstack, N. (2019) · Journal of Plastic Reconstructive & Aesthetic Surgery · doi:10.1016/j.bjps.2019.11.006 · Cited by 62
Radiation Risks From Cardiovascular Imaging Tests
Meinel, F. G., Nance, J. W., Harris, B. S., Cecco, C. N. D., Costello, P., & Schoepf, U. J. (2014) · Circulation · doi:10.1161/circulationaha.113.005340 · Cited by 61
Increasing Utilization of Emergency Department Neuroimaging From 2007 Through 2017
ElHabr, A. K., Merdan, S., Ayer, T., Prater, A., Hanna, T. N., Horný, M., Duszak, R., & Hughes, D. R. (2021) · American Journal of Roentgenology · doi:10.2214/ajr.21.25864 · Cited by 60
Sadeghi, M., Sadeghi, S., Naghib, S. M., & Garshasbi, H. R. (2023) · Biosensors · doi:10.3390/bios13040481 · Cited by 60
Long-term effects of ionising radiation on the brain: cause for concern?
Kempf, S. J., Azimzadeh, O., Atkinson, M. J., & Tapio, S. (2012) · Radiation and Environmental Biophysics · doi:10.1007/s00411-012-0436-7 · Cited by 61
Cost-effectiveness of the PECARN Rules in Children With Minor Head Trauma
Nishijima, D. K., Yang, Z., Urbich, M., Holmes, J. F., Zwienenberg-Lee, M., Melnikow, J. A., & Kuppermann, N. (2014) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2014.08.019 · Cited by 60
Kempf, S. J., Buratovic, S., von Toerne, C., Moertl, S., Stenerlöw, B., Hauck, S. M., Atkinson, M. J., Eriksson, P., & Tapio, S. (2014) · PLoS ONE · doi:10.1371/journal.pone.0110464 · Cited by 52
Ito, T., & Jensen, R. T. (2016) · International Journal of Endocrine Oncology · doi:10.2217/ije.15.29 · Cited by 61
Patient organ and effective dose estimation in CT: comparison of four software applications
Mattia, C. D., Campanaro, F., Rottoli, F., Colombo, P. E., Pola, A., Vanzulli, A., & Torresin, A. (2020) · European Radiology Experimental · doi:10.1186/s41747-019-0130-5 · Cited by 60
Seong, K. M., Seo, S., Lee, D., Kim, M.-J., Lee, S., Park, S., & Jin, Y. W. (2016) · Journal of Korean Medical Science · doi:10.3346/jkms.2016.31.s1.s10 · Cited by 62
Radiologic Assessment of Lymph Nodes in Oncologic Patients
Mao, Y. J., Hedgire, S., & Harisinghani, M. G. (2013) · Current Radiology Reports · doi:10.1007/s40134-013-0036-6 · Cited by 59
Pediatric sudden sensorineural hearing loss: Diagnosed causes and response to intervention
Tarshish, Y., Leschinski, A., & Kenna, M. A. (2013) · International Journal of Pediatric Otorhinolaryngology · doi:10.1016/j.ijporl.2013.01.004 · Cited by 59
Vandevoorde, C., Franck, C., Bacher, K., Breysem, L., Smet, M.-H., Ernst, C. W., Backer, A. D., Moortele, K. V. D., Smeets, P., & Thierens, H. (2014) · European Radiology · doi:10.1007/s00330-014-3463-8 · Cited by 61
A comparison of pediatric and adult CT organ dose estimation methods
Gao, Y., Quinn, B. M., Mahmood, U. A., Long, D., Erdi, Y. E., Germain, J. S., Pandit-Taskar, N. D., Xu, X. G., Bolch, W. E., & Dauer, L. T. (2017) · BMC Medical Imaging · doi:10.1186/s12880-017-0199-3 · Cited by 60
Metadata
- Authors
- Pearce, M. S., Salotti, J. A., Little, M. P., McHugh, K., Lee, C., Kim, K. P., Howe, N. L., Ronckers, C. M., Rajaraman, P., Craft, A. W., Parker, L., & Berrington de González, A.
- Affiliations
- Royal Victoria Infirmary (GB)
- National Cancer Institute (US)
- Great Ormond Street Hospital (GB)
- Kyung Hee University (KR)
- Dalhousie University (CA)
- Corresponding author
- Pearce, Mark S
- ORCID
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 2012-08
- Volume
- 380
- Issue
- 9840
- Pages
- 499-505
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- PMC
- PMC3418594
- OpenAlex
- W2137571255
- Semantic Scholar
- 2ad40ffeb1ce211dc0f661c6809c18fd97a96295
- Cited by
- 3,735
- References
- 28
- Citations by year
- 2026: 176 · 2025: 192 · 2024: 230 · 2023: 223 · 2022: 232 · 2021: 296 · 2020: 305 · 2019: 264 · 2018: 273 · 2017: 265 · 2016: 294 · 2015: 342 · 2014: 301 · 2013: 272 · 2012: 63
- FWCI
- 236.22
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- creativecommons.org/licenses/by/3.0/ (vor, 349 d)
- Locations
- The Lancet (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Newcastle University ePrints (Newcastle Univesity)
- Funders
- US National Cancer Institute and by the Radiation Research Programme of the UK Department of Health (RRX119)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Effects of Radiation Exposure
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiology practices and education
- Keywords
- computed tomography, ionizing radiation, childhood cancer risk, leukemia, brain tumors, cumulative radiation dose, red bone marrow dose, brain dose, excess relative risk, cancer incidence, cancer mortality, children and young adults, radiation-induced cancer, Great Britain, dose-response relationship
- MeSH terms
- Adolescent, Adult, Age Factors, Brain Neoplasms, Child, Child, Preschool, Female, Follow-Up Studies, United Kingdom, Humans, Infant, Leukemia, Male, Neoplasms, Radiation-Induced, Radiation Dosage, Radiation, Ionizing, Retrospective Studies, Risk Factors, Tomography, X-Ray Computed, United States, Cohort Studies, Incidence, Risk Assessment, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.