Adult Computed Tomography examinations in Uganda: Towards determining the National Diagnostic Reference Levels

Open access

Abstract

Diagnostic Reference Levels (DRLs), typically set at the 75th percentile of the dose distribution from surveys conducted across a broad user base using a specified dose-measurement protocol, are recommended for radiological examinations. There is a need to develop and implement DRLs as a standardisation and optimisation tool for the radiological protection of patients at Computed Tomography (CT) facilities.

Overview

CoChat Summary

TL;DR

This retrospective cross-sectional study across seven CT facilities in Uganda established national diagnostic reference levels (NDRLs) for adult head, chest, abdomen, and lumbar spine CT examinations. The authors found substantial variation across facilities and concluded that DLP values were markedly high relative to regional and international values, calling for protocol optimization and staff training.

Key findings

  • A total of 574 patients were examined, with an average age of 47.1 years; 55.6% of participants were male.
  • The national DRLs (reported as average median values) were 56.02 mGy / 1260.3 mGy.cm for head CT, 7.82 mGy / 377.0 mGy.cm for chest CT, 12.54 mGy / 1418.3 mGy.cm for abdominal CT, and 19.48 mGy / 843 mGy.cm for lumbar spine CT.
  • CTDIvol showed strong positive relationships with examination mAs in all four exam types, including rs = 0.9017 overall, 0.8921 for head, 0.8095 for abdomen, and 0.9388 for lumbar spine, all p < 0.001.
  • The authors report that DLP values were markedly high across all facilities and higher than regional/international values, while CTDIvol values were generally comparable.

Methods

  • Retrospective cross-sectional study in 7 CT scan facilities in Uganda, representing 35% of CT scan facilities in the country; facilities were purposively selected to include public/private and urban/upcountry sites.
  • 574 adult patients were recruited using systematic random sampling for head, chest, abdomen, and lumbar spine CT; lumbar spine recruitment was from 6 facilities because one lacked enough patients.
  • Dose and protocol variables were extracted from CT consoles and analyzed in STATA 15; DRLs were derived from median and 75th percentile calculations by anatomical region, with relationships assessed using correlation analysis.

Limitations

  • The paper states that none of the facilities had size-specific dose estimate (SSDE) capabilities, limiting patient-size-adjusted dose estimation.
  • The text notes no established radiation dose management systems and software in Uganda at the time of data collection, which likely constrained dose monitoring and standardization.
  • Evident from the text: the study covered 7 facilities and some analyses used only facilities with at least 20 patients, so the national estimates may still reflect incomplete facility-level coverage and uneven sample sizes across exam types.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1186/s12880-022-00838-x

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Verification

Claims the paper makes

5 Valid · 2 Not valid · 12 Not checked · 35 Own results and interpretations

13 more claims

Create a free account to see all 54 claims and to verify the 3 references still open.

See all claims — free account
  • Probably not a substantial claim. 23
  • It may state two separate claims as one. 16

Create a free account to see these claims.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 24 references

Research works printed but not linked: 1

  1. Clarke R, Fry F, Stather J, Webb G. 1990 recommendations of the international commission on radiological protection. Doc NRPB. 1993;4(1):1–5.

Cited by

See all 26

Metadata

Authors
Erem, G., Ameda, F., Otike, C., Olwit, W., Mubuuke, A. G., Schandorf, C., Kisolo, A., & Kawooya, M. G.
Affiliations
  • Makerere University (UG)
  • University of Ghana (GH)
  • Ernest Cook University (UG)
Corresponding author
Erem, Geoffrey
Venue
BMC Medical Imaging
Published
2022-06-11
Volume
22
Issue
1
Pages
112-112
ISSN
1471-2342 (ISSN-L)
OpenAlex
W4282933659
Cited by
26
References
24
Citations by year
2026: 4 · 2025: 10 · 2024: 7 · 2023: 5
FWCI
2.67
Type
journal article
Language
en
Open access
Licence
Locations
  • BMC Medical Imaging (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiology practices and education
  • Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
Keywords
diagnostic reference levels, computed tomography, radiation dose, dose-length product, patient radiation protection, dose optimization, head CT, chest CT, abdominal CT, lumbar spine CT, Uganda, mAs reduction
MeSH terms
Diagnostic Reference Levels, Adult, Cross-Sectional Studies, Humans, Middle Aged, Radiation Dosage, Reference Values, Retrospective Studies, Tomography, X-Ray Computed, Uganda

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-10-11, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-11 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (gpt-6-sol).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Adult Computed Tomography examinations in Uganda: Towards determining the National Diagnostic Reference Levels. https://app.cochat.ai/papers/10.1186/s12880-022-00838-x
The paper
Erem, G., Ameda, F., Otike, C., Olwit, W., Mubuuke, A. G., Schandorf, C., Kisolo, A., & Kawooya, M. G. (2022). Adult Computed Tomography examinations in Uganda: Towards determining the National Diagnostic Reference Levels. BMC Medical Imaging. https://doi.org/10.1186/s12880-022-00838-x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.