Comparing real-time and intermittently scanned continuous glucose monitoring in adults with type 1 diabetes (ALERTT1): a 6-month, prospective, multicentre, randomised controlled trial
Open accessAbstract
Background People with type 1 diabetes can continuously monitor their glucose levels on demand (intermittently scanned continuous glucose monitoring [isCGM]), or in real time (real-time continuous glucose monitoring [rtCGM]). However, it is unclear whether switching from isCGM to rtCGM with alert functionality offers additional benefits. Therefore, we did a trial comparing rtCGM and isCGM in adults with type 1 diabetes (ALERTT1).Methods We did a prospective, double-arm, parallel-group, multicentre, randomised controlled trial in six hospitals in Belgium. Adults with type 1 diabetes who previously used isCGM were randomly assigned (1:1) to rtCGM (intervention) or isCGM (control). Randomisation was done centrally using minimisation dependent on study centre, age, gender, glycated haemoglobin (HbA 1c), time in range (sensor glucose 3·9-10·0 mmol/L), insulin administration method, and hypoglycaemia awareness. Participants, investigators, and study teams were not masked to group allocation. Primary endpoint was mean between-group difference in time in range after 6 months assessed in the intention-to-treat sample. This trial is registered with ClinicalTrials.gov, NCT03772600.Findings Between Jan 29 and Jul 30, 2019, 269 participants were recruited, of whom 254 were randomly assigned to rtCGM (n=127) or isCGM (n=127); 124 and 122 participants completed the study, respectively. After 6 months, time in range was higher with rtCGM than with isCGM (59·6% vs 51·9%; mean difference 6·85 percentage points [95% CI 4·36-9·34]; p<0·0001). After 6 months HbA 1c was lower (7·1% vs 7·4%; p<0·0001), as was time <3·0 mmol/L (0·47% vs 0·84%; p=0·0070), and Hypoglycaemia Fear Survey version II worry subscale score (15·4 vs 18·0; p=0·0071). Fewer participants on rtCGM experienced severe hypoglycaemia (n=3 vs n=13; p=0·0082). Skin reaction was more frequently observed with isCGM and bleeding after sensor insertion was more frequently reported by rtCGM users.Interpretation In an unselected adult type 1 diabetes population, switching from isCGM to rtCGM significantly improved time in range after 6 months of treatment, implying that clinicians should consider rtCGM instead of isCGM to improve the health and quality of life of people with type 1 diabetes.Funding Dexcom.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Visser et al. (2021) quantified an almost 21% reduction in hypoglycemia fear scores with rtCGM compared to isCGM (P = 0.003).
“The study by Visser et al. (2021) quantified an almost 21 % reduction in hypoglycemia fear scores with rtCGM compared to isCGM (P-value = 0.003).”
From Effectiveness of continuous glucose monitoring systems on glycemic control in adults with type 1 diabetes: A systematic review and meta-analysis (2025) · cites this paper as Visser et al. (2021)
The Results and Table 2 (Additional information; page unavailable) support lower hypoglycaemia-worry scores with rtCGM than isCGM at six months. They report scores of 15.4 versus 18.0, an adjusted difference of −2.62 points and p=0.0071—not an almost 21% reduction with p=0.003. (LLM, conf=0.91)
Experimental — accuracy not yet measuredSwitching from is-CGM without alarms to rt-CGM improved TIR and HbA1c and reduced level 3 hypoglycemia.
“However, switching from is-CGM without alarms to rt-CGM improved TIR and HbA 1c and reduced level 3 hypoglycemia (77).”
In adults with type 1 diabetes, real-time CGM shows greater benefit than intermittently scanned CGM for improving time in range in one randomized controlled trial.
“In the other study, the primary outcome was improved TIR, and rtCGM also showed greater benefits compared with isCGM (84).”
From 7. Diabetes Technology: Standards of Care in Diabetes—2025 (2025) · cites this paper as [84]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
The citation lists haven’t been fetched yet
References 29 · Cited by 165
- Authors
- Visser, M. M., Charleer, S., Fieuws, S., De Block, C., Hilbrands, R., Van Huffel, L., Maes, T., Vanhaverbeke, G., Dirinck, E., Myngheer, N., Vercammen, C., Nobels, F., Keymeulen, B., Mathieu, C., & Gillard, P.
- Affiliations
- KU Leuven (BE)
- Hasselt University (BE)
- Vrije Universiteit Brussel (BE)
- Imelda Hospital (BE)
- AZ Groeninge (BE)
- University of Antwerp (BE)
- Onze Lieve Vrouwziekenhuis Hospital (BE)
- Corresponding author
- Gillard, Pieter
- ORCID
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 2021-06
- Volume
- 397
- Issue
- 10291
- Pages
- 2275-2283
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W3168702229
- Cited by
- 165
- References
- 29
- Citations by year
- 2026: 11 · 2025: 20 · 2024: 31 · 2023: 52 · 2022: 35 · 2021: 16
- FWCI
- 24.97
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Lirias (submittedVersion, other-oa)
- VUBIR (Vrije Universiteit Brussel) (submittedVersion)
- Document Server@UHasselt (UHasselt) (submittedVersion)
- Funders
- Dexcom Inc
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- type 1 diabetes, real-time continuous glucose monitoring, intermittently scanned continuous glucose monitoring, time in range, HbA1c, hypoglycemia, fear of hypoglycemia, hypoglycemia awareness, glycemic variability, insulin dose adjustment, adults with type 1 diabetes
- MeSH terms
- Adult, Belgium, Blood Glucose, Diabetes Mellitus, Type 1, Female, Glycated Hemoglobin, Humans, Hypoglycemia, Hypoglycemic Agents, Insulin, Insulin Infusion Systems, Male, Prospective Studies, Quality of Life, Blood Glucose Self-Monitoring
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review