STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 12,001–12,100 of 47,868
Athanasiadou, E., Kyrkou, C., Fotiou, M., Tsakoumaki, F., Dimitropoulou, A., Polychroniadou, E., Menexes, G., Athanasiadis, A., Biliaderis, C., & Michaelidou, A.-M. (2016) · Nutrients · doi:10.3390/nu8090522 · Cited by 40
The Ability of the PACER to Elicit Peak Exercise Response in the Youth
Scott, S. N., Thompson, D. L., & Coe, D. P. (2013) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e318281e4a8 · Cited by 42
Validity and reliability of the WIMU inertial device for the assessment of the vertical jump
Pino‐Ortega, J., García-Rubio, J., & Ibáñez, S. J. (2018) · PeerJ · doi:10.7717/peerj.4709 · Cited by 42
Assessment of subjective refraction with a clinical adaptive optics visual simulator
Hervella, L., Villegas, E. A., Prieto, P. M., & Artal, P. (2018) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2018.08.022 · Cited by 42
Baur, L. H. B., Schipperheyn, J. J., van der Velde, E. A., van der Wall, E. E., Reiber, J. H. C., van der Geest, R. J., van Dijkman, P. R. M., Gerritsen, J., van Eck‐Smit, B. L. F., Voogd, P. J., et al. (1996) · International journal of cardiac imaging · doi:10.1007/bf01797736 · Cited by 42
Foot volume estimates based on a geometric algorithm in comparison to water displacement.
MAYROVITZ, H. N., Sims, N., Hill, C. J., Hernandez, T., Greenshner, A., & Diep, H. (2005) · PubMed · Cited by 42
Accurate measurement of impaired glomerular filtration using single-dose oral cimetidine
Zaltzman, J. S., Whiteside, C. I., Cattran, D., Lopez, F. M., & Logan, A. G. (1996) · American Journal of Kidney Diseases · doi:10.1016/s0272-6386(96)90160-2 · Cited by 42
Wippermann, C.-F., Huth, R., Schmidt, F., Thul, J., Betancor, M., & Schranz, D. (1996) · Intensive Care Medicine · doi:10.1007/bf01712169 · Cited by 42
Simpson, D. M., Panerai, R. B., Evans, D. H., & Naylor, A. R. (2001) · Annals of Biomedical Engineering · doi:10.1114/1.1335537 · Cited by 44
Measuring the accuracy of the infrared tympanic thermometer: Correlation does not signify agreement
Yaron, M., Lowenstein, S. R., & Koziol‐McLain, J. (1995) · Journal of Emergency Medicine · doi:10.1016/0736-4679(95)00065-i · Cited by 42
The psychological impact of injury: effects of prior sport and exercise involvement: Table 1
Johnston, L. H., & Carroll, D. (2000) · British Journal of Sports Medicine · doi:10.1136/bjsm.34.6.436 · Cited by 59
Urinary excretion reflects lung deposition of aminoglycoside aerosols in cystic fibrosis
Dequin, P. F., Faurisson, F., Lemarié, É., Delatour, F., Marchand, S., Valat, C., Boissinot, E., de Gialluly, C., & Diot, P. (2001) · European Respiratory Journal · doi:10.1183/09031936.01.99086801 · Cited by 42
Nemes, A., Galema, T. W., Geleijnse, M. L., Soliman, O. I. I., Yap, S., Anwar, A. M., & ten Cate, F. J. (2006) · American Heart Journal · doi:10.1016/j.ahj.2006.08.025 · Cited by 43
Reliability of pudendal nerve terminal motor latency
Tetzschner, T., Sørensen, M., Rasmussen, O. Ø., Lose, G., & Christiansen, J. (1997) · International Journal of Colorectal Disease · doi:10.1007/s003840050106 · Cited by 42
Assessment of Sagittal Plane Segmental Motion in the Lumbar Spine
Leivseth, G., Brinckmann, P., Frobin, W., Johnsson, R., & Strömqvist, B. (1998) · Spine · doi:10.1097/00007632-199812010-00021 · Cited by 42
Hendel, H. W., Gotfredsen, A., Højgaard, L., Andersen, T., & Hilsted, J. (1996) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365519609088814 · Cited by 43
Métodos estadísticos para evaluar la concordancia
Carrasco, J. L., & Jover, L. (2004) · Medicina Clínica · doi:10.1157/13057543 · Cited by 68
Converting Enzyme Inhibition Normalizes QT Interval in Spontaneously Hypertensive Rats
Baillard, C., Mansier, P., Ennezat, P. V., Mangin, L., Médigue, C., Swynghedauw, B., & Chevalier, B. (2000) · Hypertension · doi:10.1161/01.hyp.36.3.350 · Cited by 42
Cyclosporine versus tacrolimus (FK 506) for prevention of cardiac allograft vasculopathy
Klauss, V., König, A., Spes, C. H., Meiser, B., Rieber, J., Siebert, U., Regar, E. S., Pfeiffer, M. M., Reichart, B., Theisen, K., et al. (2000) · The American Journal of Cardiology · doi:10.1016/s0002-9149(99)00631-1 · Cited by 42
Mast, M., Sönnichsen, A. C., Langnäse, K., Labitzke, K., Bruse, U., Preuß, U., & Müller, M. J. (2002) · British Journal Of Nutrition · doi:10.1079/bjn2001504 · Cited by 54
Leg-length discrepancy measured by ultrasonography
Terjesen, T., Benum, P., Rossvoll, I., Svenningsen, S., Isern, A. E. F., & Nordbø, T. (1991) · Acta Orthopaedica Scandinavica · doi:10.3109/17453679108999237 · Cited by 42
Pagano, D., Fath‐Ordoubadi, F., Beatt, K. J., Townend, J., Bonser, R. S., & Camici, P. G. (2001) · Heart · doi:10.1136/heart.85.2.208 · Cited by 42
Adams, J. A., Zabaleta, I. A., Stroh, D., & Sackner, M. A. (1993) · Pediatric Pulmonology · doi:10.1002/ppul.1950160408 · Cited by 42
Kardon, R. E., Cao, Q. L., Masani, N. D., Sugeng, L., Supran, S. E., Warner, K. G., Pandian, N. G., & Marx, G. R. (1998) · Circulation · doi:10.1161/01.cir.98.13.1307 · Cited by 42
Calibration and reliability of the Periotron 6000 for individual gingival crevicular fluid samples
Chappie, I. L. C., Cross, I. A., Glenwright, H. D., & Matthews, J. B. (1995) · Journal of Periodontal Research · doi:10.1111/j.1600-0765.1995.tb01255.x · Cited by 42
Sung, V. C. T., Bhan, A., & Vernon, S. A. (2002) · British Journal of Ophthalmology · doi:10.1136/bjo.86.2.196 · Cited by 47
Determination of Hemoglobin Saturation in Patients With Acute Sickle Chest Syndrome
Kress, J. P., Pohlman, A. S., & Hall, J. B. (1999) · CHEST Journal · doi:10.1378/chest.115.5.1316 · Cited by 45
A comparison of kinematics and performance measures of two rowing ergometers.
Steer, R. R., McGregor, A. H., & Bull, A. M. J. (2006) · Europe PMC (PubMed Central) · Cited by 43
Tura, A., Pacini, G., Kautzky-Willer, A., Ludvik, B., Prager, R., & Thomaseth, K. (2003) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00104.2002 · Cited by 42
Agreement Between Rectal and Tympanic Membrane Temperatures in Marathon Runners
Roth, R. A., Verdile, V. P., Grollman, L., & STONE, D. (1996) · Annals of Emergency Medicine · doi:10.1016/s0196-0644(96)70007-0 · Cited by 42
Comparison of a sidestream capnograph and a mainstream capnograph in mechanically ventilated dogs
Neto, F. J. T., Carregaro, A. B., Mannarino, R., Cruz, M. L., & Luna, S. P. L. (2002) · Journal of the American Veterinary Medical Association · doi:10.2460/javma.2002.221.1582 · Cited by 42
Kessler, R., Weitzenblum, E., Chaouat, A., Iamandi, C., & Alliotte, T. (2003) · CHEST Journal · doi:10.1378/chest.123.3.704 · Cited by 44
Comparison of Topiramate Concentrations in Plasma and Serum by Fluorescence Polarization Immunoassay
Berry, D. J., & Patsalos, P. N. (2000) · Therapeutic Drug Monitoring · doi:10.1097/00007691-200008000-00016 · Cited by 42
Reliability in evidence-based clinical practice: a primer for allied health professionals
Batterham, A. M., & George, K. (2000) · Physical Therapy in Sport · doi:10.1054/ptsp.2000.0010 · Cited by 42
Peak nasal inspiratory and expiratory flow measurements--practical tools in primary care?
Blomgren, K., Simola, M., Hytönen, M. L., & Pitkäranta, A. (2003) · PubMed · Cited by 43
Image processing of computerised visual field data.
Fitzke, F. W., Crabb, D. P., McNaught, A. I., Edgar, D. F., & Hitchings, R. A. (1995) · British Journal of Ophthalmology · doi:10.1136/bjo.79.3.207 · Cited by 42
RETRACTED ARTICLE: Point-of-care (POC) measurement of coagulation after cardiac surgery
Boldt, J., Walz, G., Triem, J. G., Suttner, S., & Kumle, B. (1998) · Intensive Care Medicine · doi:10.1007/s001340050743 · Cited by 42
Retractedvan Melick, H. H. E., Gisolf, K. W. H., Eckhardt, M. D., van Venrooij, G. E. P. M., & Boon, T. A. (2001) · Urology · doi:10.1016/s0090-4295(01)01136-0 · Cited by 42
Kim, W. Y., Bisgaard, T., Nielsen, S. L., Poulsen, J. K., Pedersen, E. M., Hasenkam, J. M., & Yoganathan, A. P. (1994) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(94)90314-x · Cited by 42
TH1/TH2 immune response profiles differ between atopic children in eastern and western Germany
Renz, H., von Mutius, E., Illi, S., Wolkers, F., Hirsch, T., & Weiland, S. K. (2002) · Journal of Allergy and Clinical Immunology · doi:10.1067/mai.2002.121459 · Cited by 42
Clinical comparison of the ProTon and Tono-Pen tonometers with the Goldmann applanation tonometer.
Midelfart, A., & Wigers, A. R. (1994) · British Journal of Ophthalmology · doi:10.1136/bjo.78.12.895 · Cited by 42
Observer variability in the sonographic measurement of renal length in childhood
Sargent, M. A., & Wilson, B. P. M. (1992) · Clinical Radiology · doi:10.1016/s0009-9260(05)80382-4 · Cited by 42
Egger, M., Smith, G. D., Pfluger, D. H., Altpeter, E., & Elwood, P. C. (1999) · Atherosclerosis · doi:10.1016/s0021-9150(98)00300-1 · Cited by 46
Nitric oxide measured with single-breath and tidal-breathing methods in asthma and COPD
Rutgers, S. R., Meijer, R., Kerstjens, H. A. M., van der Mark, T. W., Koëter, G. H., & Postma, D. S. (1998) · European Respiratory Journal · doi:10.1183/09031936.98.12040816 · Cited by 48
Beta endorphin release in patients after spontaneous and provoked acute myocardial ischaemia.
Oldroyd, K. G., Harvey, K., GRAY, C. E., Beastall, G. H., & Cobbe, S. M. (1992) · Heart · doi:10.1136/hrt.67.3.230 · Cited by 42
Detection of apnoeas, hypopnoeas and arousals by the AutoSet in the sleep apnoea/hypopnoea syndrome
Rees, K., Wraith, P., Berthon-Jones, M., & Douglas, N. (1998) · European Respiratory Journal · doi:10.1183/09031936.98.12040764 · Cited by 42
Measurement of myocardial blood flow with PET using 1-11C-acetate.
Sciacca, R. R., Akinboboye, O. O., Chou, R. L., Epstein, S., & Bergmann, S. R. (2001) · PubMed · Cited by 42
Pennock, G. D., Yun, D. D., Agarwal, P. G., Spooner, P. H., & Goldman, S. (1997) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1997.273.4.h2018 · Cited by 42
Computer-assisted assessment of human sperm morphology: comparison with visual assessment
Wang, C., Leung, A., Tsoi, W., Leung, J., Ng, V., Lee, K.-F., & Chan, S. Y. W. (1991) · Fertility and Sterility · doi:10.1016/s0015-0282(16)54310-6 · Cited by 46
Herpesvirus papio 2: alternative antigen for use in monkey B virus diagnostic assays.
Ohsawa, K., Lehenbauer, T. W., & Eberle, R. (1999) · PubMed · Cited by 42
Evaluation of the turbine pocket spirometer.
Gunawardena, K. A., Houston, K., & Smith, A. P. (1987) · Thorax · doi:10.1136/thx.42.9.689 · Cited by 42
Cottin, Y., Touzery, C., Guy, F., Lalande, A., Ressencourt, O., Roy, S., WALKER, P. M., Louis, P., Brunotte, F., & Wolf, J. E. (1999) · Radiology · doi:10.1148/radiology.213.2.r99nv38513 · Cited by 44
Comparison of rates of bone loss from the spine measured using two manufacturers' densitometers
Peel, N. F. A., & Eastell, R. (1995) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650101124 · Cited by 42
Prediction of oxygenation during sleep in patients with chronic obstructive lung disease.
McKeon, J. L., Murree-Allen, K., & Saunders, N. A. (1988) · Thorax · doi:10.1136/thx.43.4.312 · Cited by 42
Pellerin, D., Cohen, L. D., Larrazet, F. S., Pajany, F., Witchitz, S., & Veyrat, C. (1997) · The American Journal of Cardiology · doi:10.1016/s0002-9149(97)00429-3 · Cited by 42
Three‐dimensional CT angiography: A new technique for imaging microvascular anatomy
Rozen, W. M., Stella, D. L., Ashton, M. W., Phillips, T. J., & Taylor, G. I. (2007) · Clinical Anatomy · doi:10.1002/ca.20557 · Cited by 43
Critchley, L. A. H. (2011) · Anesthesiology · doi:10.1097/aln.0b013e318215e1e5 · Cited by 44
A comparative evaluation of various methods for microalbuminuria screening
Sarafidis, P. A., Riehle, J., Bogojevic, Z., Basta, E., Chugh, A., & Bakris, G. L. (2008) · American Journal of Nephrology · doi:10.1159/000111825 · Cited by 41
Jones, M. A., Stratton, G., Reilly, T., & Unnithan, V. (2002) · Acta Paediatrica · doi:10.1111/j.1651-2227.2002.tb02831.x · Cited by 41
Hamm, J. B., Nguyen, B.-V., Kiss, G., Wargnier, J. P., Jauffroy, A., Hélaine, L., Arvieux, C. C., & Guéret, G. (2010) · Anaesthesia and Intensive Care · doi:10.1177/0310057x1003800211 · Cited by 41
Ubbink, D. T., van Asbeck, E., Aarts, J. W. M., Stubenrouch, F. E., Geerts, P. A. F., Atsma, F., & Meinders, M. J. (2022) · Patient Education and Counseling · doi:10.1016/j.pec.2022.03.007 · Cited by 45
Zhao, J. J., Syn, N. L. X., Tan, B. K. J., Yap, D. W. T., Teo, C. B., Chan, Y. H., & Sundar, R. (2022) · BMC Medical Research Methodology · doi:10.1186/s12874-022-01567-z · Cited by 45
Olson, D. J. (2023) · Language Testing · doi:10.1177/02655322221139162 · Cited by 51
Graybeal, A. J., Brandner, C. F., & Tinsley, G. M. (2023) · British Journal Of Nutrition · doi:10.1017/s0007114523000090 · Cited by 49
Sui, X., Liu, H., Du, Z., & Yu, S. (2023) · Journal of Energy Storage · doi:10.1016/j.est.2023.108024 · Cited by 43
Anand, R., McLeese, R. H., Busby, J., Stewart, J. E., Clarke, M. J., Man, W. D., & Bradley, J. M. (2023) · European Respiratory Review · doi:10.1183/16000617.0248-2022 · Cited by 41
Ambient health sensing on passive surfaces using metamaterials
Nguyen, D. T., Zeng, Q., Tian, X., Chia, P., Wu, C., Liu, Y., & Ho, J. S. (2024) · Science Advances · doi:10.1126/sciadv.adj6613 · Cited by 44
Guo, T., Winterburn, J. L., Pipitone, J., Duerden, E. G., Park, M. T. M., Chau, V., Poskitt, K. J., GRUNAU, R. E., Synnes, A. R., Miller, S. P., et al. (2015) · NeuroImage Clinical · doi:10.1016/j.nicl.2015.07.019 · Cited by 45
Surgeons often underestimate the amount of blood loss in replacement surgeries.
Ram, G. G., Suresh, P., & Varthi, V. P. (2014) · PubMed · Cited by 41
mDurance: A Novel Mobile Health System to Support Trunk Endurance Assessment
Banos, O., Moral-Munoz, J., Diaz-Reyes, I., Arroyo-Morales, M., Damas, M., Herrera-Viedma, E., Hong, C., Lee, S., Pomares, H., Rojas, I., et al. (2015) · Sensors · doi:10.3390/s150613159 · Cited by 41
Cherney, D. Z. I., Sochett, E. B., Dekker, M. G., & Perkins, B. A. (2010) · Diabetic Medicine · doi:10.1111/j.1464-5491.2010.03121.x · Cited by 46
Assessment of Tandem Measurements of pH and Total Gut Transit Time in Healthy Volunteers
Mikolajczyk, A. E., Watson, S., Surma, B. L., & Rubin, D. T. (2015) · Clinical and Translational Gastroenterology · doi:10.1038/ctg.2015.22 · Cited by 47
Motivational interviewing for improving recovery after stroke
Cheng, D., Qu, Z., Huang, J., Xiao, Y., Luo, H., & Wang, J. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011398.pub2 · Cited by 42
Ebert, N., Lösment, A., Martus, P., Jakob, O., Gaedeke, J., Kuhlmann, M. K., Bartel, J., Schuchardt, M., Tölle, M., Huang, T., et al. (2015) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfv116 · Cited by 41
Pineda, A., & Cardoso, F. C. (2015) · Journal of Dairy Science · doi:10.3168/jds.2015-9667 · Cited by 41
Kanz, P., Drillich, M., Klein-Jöbstl, D., Mair, B., Borchardt, S., Meyer, L., Schwendenwein, I., & Iwersen, M. (2015) · Journal of Dairy Science · doi:10.3168/jds.2014-8957 · Cited by 48
Transcutaneous blood gas monitoring during neonatal intensive care
Sandberg, K. L., Brynjarsson, H., & Hjalmarson, O. (2011) · Acta Paediatrica · doi:10.1111/j.1651-2227.2011.02164.x · Cited by 41
He, X., & Liu, J. (2009) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.09-3439 · Cited by 41
Back-extrapolation of estimates of exposure from current land-use regression models
Chen, H. M., Goldberg, M. S., Crouse, D. L., Burnett, R. T., Jerrett, M., Villeneuve, P. J., Wheeler, A. J., Labrèche, F., & Ross, N. A. (2010) · Atmospheric Environment · doi:10.1016/j.atmosenv.2010.07.061 · Cited by 44
Wong, G. K. C., Lam, S. W., Ngai, K., Wong, A., Poon, W. S., & Mok, V. (2013) · Journal of the Neurological Sciences · doi:10.1016/j.jns.2013.09.033 · Cited by 43
Correa-Pérez, M. E., López‐Miguel, A., Miranda-Anta, S., Iglesias-Cortiñas, D., ALIO, J. L., & Maldonado, M. J. (2012) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.11-9033 · Cited by 41
Comparison of Spirometric-Gated and -Ungated HRCT in COPD
Moroni, C., Mascalchi, M., Camiciottoli, G., Bartolucci, M., Falaschi, F., Battolla, L., Orlandi, I., Pistolesi, M., & Villari, N. (2003) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-200305000-00013 · Cited by 41
Assessment of MIRD data for internal dosimetry using the GATE Monte Carlo code
Parach, A. A., Rajabi, H., & Askari, M. A. (2011) · Radiation and Environmental Biophysics · doi:10.1007/s00411-011-0370-0 · Cited by 44
Comparison of the precision of the Topcon SP-3000P specular microscope and an ultrasound pachymeter
Almubrad, T., Osuagwu, U. L., Abbadi, I. A., & Ogbuehi, K. C. (2011) · Clinical ophthalmology · doi:10.2147/opth.s21247 · Cited by 41
Fortune, B. A., Bui, B. V., Cull, G. A., Wang, L., & Cioffi, G. A. (2003) · Experimental Eye Research · doi:10.1016/j.exer.2003.09.013 · Cited by 41
Raue, W., Swierzy, M., Koplin, G., & Schwenk, W. (2009) · European Journal of Anaesthesiology · doi:10.1097/eja.0b013e32832bfd94 · Cited by 47
Shephard, M. D. S., Peake, M. J., Corso, O., Shephard, A. K., Mazzachi, B. C., Spaeth, B., Barbara, J. A. J., & Mathew, T. H. (2010) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2010.238 · Cited by 41
Torigoe, T., Sato, S., Nagayama, Y., Sato, T., & Yamazaki, H. (2015) · Journal of Perinatology · doi:10.1038/jp.2014.245 · Cited by 41
Bjeloš, M., Bušić, M., Čima, I., Elabjer, B. K., Bosnar, D., & Miletić, D. (2010) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-010-1546-z · Cited by 42
Development of a Children's Version of the SCORE Index of Family Function and Change
Jewell, T., Carr, A., Stratton, P., Lask, J., & Eisler, I. (2013) · Family Process · doi:10.1111/famp.12044 · Cited by 50
Khan, J. N., Nazir, S. A., Horsfield, M. A., Singh, A., Kanagala, P., Greenwood, J. P., Gershlick, A., & McCann, G. P. (2015) · BMC Research Notes · doi:10.1186/s13104-015-1007-1 · Cited by 41
Earbud-Based Sensor for the Assessment of Energy Expenditure, HR, and V˙O2max
LeBoeuf, S., Aumer, M. E., Kraus, W. E., Johnson, J. L., & Duscha, B. D. (2014) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000183 · Cited by 48
Moreno‐Montañés, J., Antón, A., García, N., Olmo, N., Morilla, A., & Fallon, M. (2009) · Journal of Glaucoma · doi:10.1097/ijg.0b013e318193c29f · Cited by 41
Circumferential ascending aortic strain and aortic stenosis
Teixeira, R. P., Moreira, N., Baptista, R., Barbosa, A., Martins, R., Castro, G., & Providência, L. A. (2012) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jes221 · Cited by 52
Mut, F., Giubbini, R., Vitola, J. V., Lusa, L., Sobic-Saranovic, D. P., Peix, A., Bertagna, F., Dieu, H. B., da Cunha, C. G., Obaldo, J. M., et al. (2014) · Journal of Nuclear Cardiology · doi:10.1007/s12350-014-9983-4 · Cited by 44
Martinez, S. M., Greenspan, L. C., Butte, N. F., Gregorich, S. E., de Groat, C. L., Deardorff, J., Penilla, C., Pasch, L. A., Flores, E., & Tschann, J. M. (2013) · Journal of Sleep Research · doi:10.1111/jsr.12114 · Cited by 47
Effect of Oxybuprocaine Eye Drops on Corneal Volume and Thickness Measurements
Rosa, N., Bernardo, M. D., Borrelli, M., Filosa, M. L., & Lanza, M. (2011) · Optometry and Vision Science · doi:10.1097/opx.0b013e3182114303 · Cited by 41
Parravano, M., Oddone, F., Boccassini, B., Menchini, F., Chiaravalloti, A., Schiavone, M., & Varano, M. (2010) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.09-4976 · Cited by 41
Graf, S., Karsegard, V. L., Viatte, V., Maisonneuve, N., Pichard, C., & Genton, L. (2013) · Clinical Nutrition · doi:10.1016/j.clnu.2013.08.012 · Cited by 41
Wu, Y., Nash, P., Barnes, L., Minett, T., Matthews, F. E., Jones, A., & Brayne, C. (2014) · BMC Public Health · doi:10.1186/1471-2458-14-1094 · Cited by 41
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.