CoChat

A Comparative Evaluation of Various Methods for Microalbuminuria Screening

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

Abstract

Background/Aims: Microalbuminuria is a marker of abnormal vascular response and a predictor of cardiovascular morbidity and mortality. We evaluated a new quantitative office-based method to assess urinary albumin excretion (UAE) and compared it to other established methods. Methods: Spot urine samples from 165 patients were analyzed at a single study site using the HemoCue system, Clinitek Microalbumin, and Chemstrip Micral test, as well as at a central laboratory, where UAE and creatinine levels were measured. The central laboratory UAE values were used as reference. We evaluated the validity of the HemoCue results and compared them to the respective data for the laboratory albumin-to-creatinine ratio (ACR). Additionally, we assessed, diagnostic sensitivity, specificity, and positive and negative predictive values of all four methods, as well as the reproducibility of the HemoCue measurements. Results: Linear regression analysis demonstrated a good correlation for the HemoCue system (y = 0.9978x – 1.0217, R 2 = 0.904) and ACR (y = 0.0815x + 0.3373, R 2 = 0.784). Sensitivity and specificity for microalbuminuria diagnosis were 92 and 98% for HemoCue, 73 and 96% for ACR, 100 and 81% for Clinitek Microalbumin, and 70 and 83% for Chemstrip Micral dipstick, respectively. The correlation coefficient of duplicate HemoCue measurements was r = 0.98 (p < 0.001). Conclusions: The HemoCue system for microalbuminuria detection was as accurate and precise as laboratory ACR estimations. Its diagnostic performance was much better than that of widely used dipstick methods.

Overview

Integrity signals

Registry

Crossref · 10.1159/000111825

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 15 references

Cited by

See all 41

Metadata

Authors
Sarafidis, P. A., Riehle, J., Bogojevic, Z., Basta, E., Chugh, A., & Bakris, G. L.
Affiliations
  • Rush University Medical Center (US)
  • University of Chicago (US)
Venue
American Journal of Nephrology
Publisher
S. Karger AG
Published
2007-11-29
Volume
28
Issue
2
Pages
324-329
ISSN
  • 0250-8095 (ISSN-L)
  • 1421-9670
OpenAlex
W1993678470
Cited by
41
References
14
Citations by year
2026: 1 · 2025: 2 · 2024: 1 · 2023: 2 · 2022: 1 · 2021: 2 · 2018: 2 · 2017: 2 · 2016: 1 · 2015: 1 · 2014: 3 · 2013: 2 · 2012: 5
FWCI
1.69
Type
journal article
Language
en
Open access
closed
Licence
Locations
  • American Journal of Nephrology (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • Quest Diagnostics
  • Bayer HealthCare
Topics
  • Health Sciences › Medicine › Nephrology › Chronic Kidney Disease and Diabetes
  • Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
Keywords
microalbuminuria, urinary albumin excretion, HemoCue, albumin-creatinine ratio, spot urine, diagnostic accuracy, measurement reproducibility, cardiovascular risk
MeSH terms
Adult, Aged, Albuminuria, Diabetes Mellitus, Female, Humans, Hypertension, Kidney Diseases, Male, Mass Screening, Middle Aged, Predictive Value of Tests, Reagent Strips, Reproducibility of Results, Urinalysis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Comparative Evaluation of Various Methods for Microalbuminuria Screening. https://app.cochat.ai/papers/10.1159/000111825
The paper
Sarafidis, P. A., Riehle, J., Bogojevic, Z., Basta, E., Chugh, A., & Bakris, G. L. (2008). A Comparative Evaluation of Various Methods for Microalbuminuria Screening. American Journal of Nephrology. https://doi.org/10.1159/000111825

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.