STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 11,601–11,700 of 47,868
Tracking of the inferior alveolar nerve: its implication in surgical planning
Agbaje, J. O., de Casteele, E. V., Salem, A. S., Anumendem, D. N., Lambrichts, I., & Politis, C. (2016) · Clinical Oral Investigations · doi:10.1007/s00784-016-2014-x · Cited by 43
Foulis, S. A., Redmond, J. E., Frykman, P., Warr, B. J., Zambraski, E. J., & Sharp, M. A. (2017) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000001894 · Cited by 43
Wavelet-based embedded algorithm for respiratory rate estimation from PPG signal
Lin, Y., Chien, Y.-H., & Chen, Y.-S. (2017) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2017.03.009 · Cited by 43
Bennett, L. D., Klein, M., Locke, K. G., Kiser, K. A., & Birch, D. G. (2017) · Translational Vision Science & Technology · doi:10.1167/tvst.6.4.15 · Cited by 44
Validity of the Digital Inclinometer and iPhone When Measuring Thoracic Spine Rotation
Bucke, J., Spencer, S., Fawcett, L., Sonvico, L., Rushton, A., & Heneghan, N. R. (2017) · Journal of Athletic Training · doi:10.4085/1062-6050-52.6.05 · Cited by 43
Laboratory and home comparison of wrist-activity monitors and polysomnography in middle-aged adults
Dunican, I. C., Murray, K., Slater, J. A., Maddison, K. J., Jones, M. J., DAWSON, B. T., Straker, L. M., Caldwell, J. A., Halson, S. L., & Eastwood, P. R. (2017) · Sleep and Biological Rhythms · doi:10.1007/s41105-017-0130-x · Cited by 50
Conventional and synthetic MRI in multiple sclerosis: a comparative study
Krauss, W., Gunnarsson, M., Nilsson, M. F., & Thunberg, P. (2017) · European Radiology · doi:10.1007/s00330-017-5100-9 · Cited by 47
Optimization and validation of automated hippocampal subfield segmentation across the lifespan
Bender, A. R., Keresztes, A., Bodammer, N., Shing, Y. L., Werkle‐Bergner, M., Daugherty, A. M., Yu, Q., Kühn, S., Lindenberger, U., & Raz, N. (2017) · Human Brain Mapping · doi:10.1002/hbm.23891 · Cited by 48
Fuzzy logic tool for wine quality classification
Petropoulos, S., Karavas, C.-S. G., Balafoutis, A. Τ., Paraskevopoulos, I., Καλλιθράκα, Σ., & Kotseridis, Y. (2017) · Computers and Electronics in Agriculture · doi:10.1016/j.compag.2017.11.015 · Cited by 43
Maceira, A. M., Tuset-Sanchis, L., López-Garrido, M. A., Andrés, M. S., López-Lereu, M. P., Monmeneu, J. V., García-González, M. P., & Higueras, L. (2017) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25894 · Cited by 48
Dessery, Y., & Pallari, J. (2018) · PLoS ONE · doi:10.1371/journal.pone.0190585 · Cited by 43
Tran, N. H., Tantidhnazet, S., Raocharernporn, S., Kiattavorncharoen, S., Pairuchvej, V., & Wongsirichat, N. (2018) · Journal of Clinical Medicine Research · doi:10.14740/jocmr3372w · Cited by 47
Raymond, C. J., Dengel, D. R., & Bosch, T. A. (2018) · Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000002320 · Cited by 43
Naegele, K., Lautenschlager, I. T., Gosert, R., Loginov, R. J., Bir, K., Helanterä, I., Schaub, S., Khanna, N., & Hirsch, H. H. (2018) · Journal of Clinical Virology · doi:10.1016/j.jcv.2018.04.013 · Cited by 43
Development of a Just-in-Time Adaptive mHealth Intervention for Insomnia: Usability Study
Pulantara, I. W., Parmanto, B., & Germain, A. (2018) · JMIR Human Factors · doi:10.2196/humanfactors.8905 · Cited by 45
Validation of a self-administered web-based 24-hour dietary recall among pregnant women
Savard, C., Lemieux, S., Lafrenière, J., Laramée, C., Robitaille, J., & Morisset, A. (2018) · BMC Pregnancy and Childbirth · doi:10.1186/s12884-018-1741-1 · Cited by 53
Directional sensitivity of dynamic cerebral autoregulation in squat-stand maneuvers
Panerai, R. B., Barnes, S., Nath, M., Ball, N., Robinson, T. G., & Haunton, V. J. (2018) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00010.2018 · Cited by 43
Abdeen, R. H., Comfort, P., Starbuck, C., & Nester, C. (2018) · Journal of Ultrasound in Medicine · doi:10.1002/jum.14770 · Cited by 43
O'Brien, M. W., Wojcik, W. R., & Fowles, J. R. (2018) · JMIR mhealth and uhealth · doi:10.2196/10706 · Cited by 45
Perthen, J. E., Ali, T., McCulloch, D., Navidi, M., Phillips, A. W., Sinclair, R. C. F., Griffin, S. M., Greystoke, A., & Petrides, G. S. (2018) · European Journal of Radiology · doi:10.1016/j.ejrad.2018.10.031 · Cited by 45
Margulescu, A. D., Nuñez‐Garcia, M., Alarcón, F., Benito, E., Enomoto, N., Cozzari, J., Chipa, F., Fernandez, H. R., Borràs, R., Guasch, E., et al. (2018) · EP Europace · doi:10.1093/europace/euy314 · Cited by 45
Lokar, K., Žagar, T., & Zadnik, V. (2019) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph16030296 · Cited by 50
Ross, K. M., Eastman, A., & Wing, R. R. (2019) · Obesity · doi:10.1002/oby.22400 · Cited by 44
Larouche‐Lebel, É., Loughran, K. A., & Oyama, M. A. (2019) · Journal of Veterinary Internal Medicine · doi:10.1111/jvim.15461 · Cited by 43
Chrencik, M. T., Khan, A. A., Luther, L., Anthony, L., Yokemick, J., Patel, J. B., Sorkin, J. D., Sikdar, S., & Lal, B. K. (2019) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2018.11.050 · Cited by 43
Panda, A., Chen, Y., Ropella‐Panagis, K., Ghodasara, S., Stopchinski, M., Seyfried, N., Wright, K., Seiberlich, N., Griswold, M. A., & Gulani, V. (2019) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26717 · Cited by 43
Marques, A. S. P. D. D., Jácome, C. I. O., Rebelo, P. F. S., Paixão, C., Oliveira, A., Cruz, J., Freitas, C., Rua, M., Loureiro, H., Peguinho, C., et al. (2019) · BMC Public Health · doi:10.1186/s12889-019-7045-1 · Cited by 46
Validity of Wrist-Worn Activity Trackers for Estimating VO2max and Energy Expenditure
Passler, S., Bohrer, J., Blöchinger, L., & Senner, V. (2019) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph16173037 · Cited by 54
Hamilton, J., Pahwa, S. S., Adedigba, J. A., Frankel, S., O’Connor, G., Thomas, R., Walker, J. R., Killinc, O., Lo, W., Batesole, J., et al. (2020) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.27155 · Cited by 46
Is Continuous Heart Rate Monitoring of Livestock a Dream or Is It Realistic? A Review
Nie, L., Berckmans, D., Wang, C., & Li, B. (2020) · Sensors · doi:10.3390/s20082291 · Cited by 53
Lauterbach, C. J., Romano, P. A., Greisler, L. A., Brindle, R. A., Ford, K. R., & Kuennen, M. R. (2020) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2020.1759768 · Cited by 43
Gao, B., Liu, Y., Ding, C., Liu, S., Chen, X., & Bian, X. (2020) · BMJ Open · doi:10.1136/bmjopen-2019-036335 · Cited by 50
Schuster, A., Lange, T., Backhaus, S. J., Strohmeyer, C., Boom, P. C., Matz, J., Kowallick, J. T., Lotz, J., Steinmetz, M., Kutty, S., et al. (2020) · Journal of the American Heart Association · doi:10.1161/jaha.120.016612 · Cited by 43
Jin, H., Fu, X., Cao, X., Sun, M., Wang, X., Zhong, Y., Yang, S., Qi, C., Peng, B., He, X., et al. (2020) · Journal of Medical Systems · doi:10.1007/s10916-020-01654-y · Cited by 45
Assessment of handheld mobile terrestrial laser scanning for estimating tree parameters
Stal, C., Verbeurgt, J., Sloover, L. D., & Wulf, A. D. (2020) · Journal of Forestry Research · doi:10.1007/s11676-020-01214-7 · Cited by 54
Suggested guidelines for validation of real-time PCR assays in veterinary diagnostic laboratories
Toohey-Kurth, K. L., Reising, M. M., Tallmadge, R. L., Goodman, L. B., Bai, J., Bolin, S. R., Pedersen, J. C., Bounpheng, M. A., Pogranichniy, R. M., Christopher‐Hennings, J., et al. (2020) · Journal of Veterinary Diagnostic Investigation · doi:10.1177/1040638720960829 · Cited by 51
Brochier, T., Guérit, F., Deeks, J. M., Garcia, C., Bance, M., & Carlyon, R. P. (2020) · Journal of the Association for Research in Otolaryngology · doi:10.1007/s10162-020-00773-0 · Cited by 47
Reproducibility of left atrial function using cardiac magnetic resonance imaging
Alfuhied, A., Marrow, B., Elfawal, S. K., Gulsin, G. S., Graham-Brown, M. P. M., Steadman, C. D., Kanagala, P., McCann, G. P., & Singh, A. (2020) · European Radiology · doi:10.1007/s00330-020-07399-z · Cited by 43
Nguyen, C. T., Christodoulou, A., Coll‐Font, J., Ma, S., Xie, Y., Reese, T. G., Mekkaoui, C., Lewis, G. D., Bi, X., Sosnovik, D. E., et al. (2020) · Magnetic Resonance in Medicine · doi:10.1002/mrm.28611 · Cited by 49
Chuaqui, T. R. C., Nielsen, M. W. D., Colton, J. S., Butler, R., & Rhead, A. T. (2020) · Composites Part B Engineering · doi:10.1016/j.compositesb.2020.108582 · Cited by 43
Body composition monitoring in children and adolescents: reproducibility and reference values
Eyck, A. V., Eerens, S., Trouet, D., Lauwers, E., Wouters, K., Winter, B. Y. D., van der Lee, J. H., Hoeck, K. V., & Ledeganck, K. J. (2021) · European Journal of Pediatrics · doi:10.1007/s00431-021-03936-0 · Cited by 47
Mao, Y., Ogata, T., Ora, H., Tanaka, N., & Miyake, Y. (2021) · Scientific Reports · doi:10.1038/s41598-021-81009-w · Cited by 52
Collins, K., Agius, P. A., Fraval, A., & Petterwood, J. (2021) · The Journal of Knee Surgery · doi:10.1055/s-0040-1722693 · Cited by 43
Golap, M. A.-U., Raju, S. M. T. U., Haque, M. R., & Hashem, M. M. A. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2021.102478 · Cited by 48
Repeatability of 2 swept-source OCT biometers and 1 optical low-coherence reflectometry biometer
Fișus, A., Hirnschall, N. D., Ruiß, M., Pilwachs, C., Georgiev, S., & Findl, O. (2021) · Journal of Cataract & Refractive Surgery · doi:10.1097/j.jcrs.0000000000000633 · Cited by 45
Blackwell, C. K., Tang, X., Elliott, A., Thomes, T., Louwagie, H., Gershon, R. C., Schalet, B. D., & Cella, D. F. (2021) · Psychological Assessment · doi:10.1037/pas0001009 · Cited by 44
Assessment of myocardial injury after reperfused infarction by T1ρ cardiovascular magnetic resonance
Stoffers, R. H., Madden, M. E., Shahid, M., Contijoch, F. J., Solomon, J., Pilla, J. J., Gorman, J. H., Gorman, R. C., & Witschey, W. R. T. (2016) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-017-0332-z · Cited by 43
Can Wearable Cameras Be Used to Validate School-Aged Children’s Lifestyle Behaviours?
Everson, B., Mackintosh, K. A., McNarry, M. A., Todd, C., & Stratton, G. (2019) · Children · doi:10.3390/children6020020 · Cited by 57
Energetics (and kinematics) of short shuttle runs
Zamparo, P., Bolomini, F., Nardello, F., & Beato, M. (2015) · European Journal of Applied Physiology · doi:10.1007/s00421-015-3180-2 · Cited by 44
Assessment of bias with emphasis on method comparison.
Johnson, R. (2008) · PubMed Central · Cited by 43
Citera, G., Padulo, L. A., Fernández, G., Lázaro, M. A., Rosemffet, M. G., & Cocco, J. A. M. (2001) · PubMed · Cited by 43
Zhou, Y., Pandit, P., Pedoia, V., Rivoire, J., Wang, Y., Liang, D., Li, A., & Ying, L. L. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25773 · Cited by 45
Paeng, J.-C., Lee, D., Cheon, G. J., Lee, M. M., Chung, J., & Lee, M. (2001) · PubMed · Cited by 43
Grading Bulbar Redness Using Cross-Calibrated Clinical Grading Scales
Schulze, M., Hutchings, N., & SIMPSON, T. L. (2011) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.10-7006 · Cited by 43
Stake, G., Monn, E., Rootwelt, K., & Monclair, T. F. (1991) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365519109104587 · Cited by 43
Kondo, C., Fukushima, K., & Kusakabe, K. (2003) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-003-1146-9 · Cited by 44
Hoad, C. L., Raine‐Fenning, N., Fulford, J., Campbell, B. K., Johnson, I. R., & Gowland, P. A. (2005) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2004.07.032 · Cited by 43
Validation of a single-channel airflow monitor for screening of sleep-disordered breathing
Nakano, H., Tanigawa, T., Ohnishi, Y., Uemori, H., Senzaki, K., Furukawa, T., & Nishima, S. (2008) · European Respiratory Journal · doi:10.1183/09031936.00130907 · Cited by 43
Piaw, C. S., Kiam, O. T., Rapaee, A., Liew, C. K., Bang, L. H., Ling, C. W., Samion, H., & Hian, S. K. (2005) · CardioVascular and Interventional Radiology · doi:10.1007/s00270-005-0003-6 · Cited by 43
Abnormal perception of the tonic vibration reflex in idiopathic focal dystonia
Yoneda, Y., Rome, S., SAGAR, H. J., & Grünewald, R. A. (2000) · European Journal of Neurology · doi:10.1046/j.1468-1331.2000.00102.x · Cited by 43
Lim, W. H., Lim, E. M., & McDonald, S. P. (2006) · Nephrology · doi:10.1111/j.1440-1797.2006.00560.x · Cited by 44
Chaise, F. D. O., Candotti, C. T., Torre, M. L., Furlanetto, T. S., Pelinson, P. P. T., & Loss, J. F. (2011) · Brazilian Journal of Physical Therapy · doi:10.1590/s1413-35552011005000031 · Cited by 43
Jiménez, D., Lobo, J. L., Monréal, M., Otero, R., & Yusen, R. D. (2012) · Journal of Thrombosis and Thrombolysis · doi:10.1007/s11239-012-0709-7 · Cited by 44
Detection of apneic events from single channel nasal airflow using 2nd derivative method
Han, J., Shin, H.-B., Jeong, D., & Park, K. S. (2008) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2008.04.012 · Cited by 43
Radiographic Assessment of the Relative Lengths of the Bones of the Fingers of the Human Hand
HAMILTON, R., & Dunsmuir, R. A. (2002) · Journal of Hand Surgery (European Volume) · doi:10.1054/jhsb.2002.0822 · Cited by 43
Beresford, M. W., & Shaw, N. J. (2003) · Pediatric Research · doi:10.1203/01.pdr.0000054653.89527.f8 · Cited by 43
Bjeloš, M., Bušić, M., Čima, I., Elabjer, B. K., Bosnar, D., & Miletić, D. (2010) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-010-1509-4 · Cited by 43
Azie, N. E., Adams, G., Darpö, B., Francom, S. F., Polasek, E. C., Wisser, J. M., & Fleishaker, J. C. (2004) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2004.92542.x · Cited by 44
Nijveldt, R., Germans, T., McCann, G. P., Beek, A. M., & van Rossum, A. C. (2008) · European Radiology · doi:10.1007/s00330-008-1017-7 · Cited by 43
Influence of Sensor Ingestion Timing on Consistency of Temperature Measures
GOODMAN, D. A., KENEFICK, R. W., CADARETTE, B. S., & CHEUVRONT, S. N. (2009) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31818a0eef · Cited by 45
The evaluation of an electronic visual analogue scale system for appetite and mood
Whybrow, S., Stephen, J. R., & Stubbs, R. J. (2005) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1602342 · Cited by 49
Comparison of 2 modifications of the twin-block appliance in matched class II samples
Parkin, N. A., McKeown, H. F., & Sandler, J. (2001) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1067/mod.2001.113790 · Cited by 43
Measurement fidelity of heart rate variability signal processing: The devil is in the details
Jarrin, D. C., McGrath, J. J., Giovanniello, S., Poirier, P., & Lambert, M. A. (2012) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2012.07.004 · Cited by 55
On the societal value of health care: what do we know about the person trade‐off technique?
Green, C. (2001) · Health Economics · doi:10.1002/hec.581 · Cited by 43
The Oxygen Uptake Response Running to Exhaustion at Peak Treadmill Speed
HARLING, S. A., Tong, R. J., & Mickleborough, T. D. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000058434.53664.ec · Cited by 43
Break-Technique Handheld Dynamometry: Relation Between Angular Velocity and Strength Measurements
Burns, S. P., & Spanier, D. (2005) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2004.12.041 · Cited by 43
Diagnostic and analytical performance of a screening panel for allergy
Herzum, I., Blümer, N., Kersten, W., & Renz, H. E. (2005) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2005.165 · Cited by 43
Repeatability of bronchial responsiveness to mannitol dry powder in children with asthma
Barben, J., Roberts, M. F., Chew, N. Y. K., Carlin, J. B., & Robertson, C. F. (2003) · Pediatric Pulmonology · doi:10.1002/ppul.10378 · Cited by 43
Papaioannou, T. G., Karatzis, E. N., Karatzi, K., GIALAFOS, E. J., Protogerou, A. D., Stamatelopoulos, K. S., Papamichael, C. M., Lekakis, J. P., & Stefanadis, C. (2007) · Journal of Hypertension · doi:10.1097/hjh.0b013e3281ab6c58 · Cited by 51
Validation of a Laboratory Method of Measuring Postpartum Blood Loss
Chua, S., Ho, L. M., Vanaja, K., Nordström, L., Roy, A. C., & Arulkumaran, S. (1998) · Gynecologic and Obstetric Investigation · doi:10.1159/000009992 · Cited by 51
Microcirculatory Changes Associated with Gastric Tube Formation in the Pig
Schröder, W., Beckurts, K. T. E., Stähler, D., Stützer, H., Fischer, J. H., & Hölscher, A. H. (2002) · European Surgical Research · doi:10.1159/000065709 · Cited by 43
Nixon, D. E., Neubauer, K. R., Eckdahl, S. J., Butz, J. A., & Burritt, M. F. (2004) · Spectrochimica Acta Part B Atomic Spectroscopy · doi:10.1016/j.sab.2004.05.013 · Cited by 43
Nogueira, P. A. D. M. S., Leal, A. C. M., Pulz, C., Nogueira, I. D. B., & Filho, J. A. O. (2006) · International Heart Journal · doi:10.1536/ihj.47.533 · Cited by 44
Tüshaus, J., Dubovyk, O., Khamzina, A., & Menz, G. (2014) · Remote Sensing · doi:10.3390/rs6065238 · Cited by 43
Multimodal signal processing for the analysis of cardiovascular variability
Porta, A., Aletti, F. M., Vallais, F., & Baselli, G. (2008) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2008.0229 · Cited by 45
A comparison of 4 questionnaires to measure fatigue in postpoliomyelitis syndrome
Horemans, H. L. D., Nollet, F., Beelen, A., & Lankhorst, G. J. (2004) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2003.06.007 · Cited by 43
Ling, J., Ohara, Y., Orime, Y., Noon, G. P., & Takatani, S. (1995) · The Journal of Clinical Monitoring · doi:10.1007/bf01617734 · Cited by 43
Evaluation of the NucliSens EasyQ assay in HIV-1-infected individuals in South Africa
Stevens, W. S., Wiggill, T. M., Horsfield, P., Coetzee, L. M., & Scott, L. E. (2004) · Journal of Virological Methods · doi:10.1016/j.jviromet.2004.11.009 · Cited by 43
Doherty, T. M., Shavelle, R. M., & French, W. J. (2005) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.20355 · Cited by 45
Ribeiro, A. C., Lindmarker, P., Johnsson, H., JUHLIN‐DANNFELT, A., & Jorfeldt, L. (1999) · Journal of Internal Medicine · doi:10.1046/j.1365-2796.1999.00498.x · Cited by 46
McCann, S. J., Gillingwater, S., & Keevil, B. G. (2005) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1258/0004563053492775 · Cited by 43
Katier, N., Uiterwaal, C. S. P. M., de Jong, B. M., Kimpen, J. L. L., & van der Ent, C. K. (2005) · CHEST Journal · doi:10.1378/chest.128.3.1822 · Cited by 43
Accommodation and induced myopia in marmosets
Troilo, D., Quinn, N., & Baker, K. (2007) · Vision Research · doi:10.1016/j.visres.2007.01.018 · Cited by 43
Menorrhagia—a search for epidemiological risk markers
Janssen, C. A. H., Scholten, P. C., & Heintz, A. P. M. (1997) · Maturitas · doi:10.1016/s0378-5122(97)00065-0 · Cited by 45
Automatic assessment of cardiac function from short-axis MRI: procedure and clinical evaluation
Nachtomy, E., Cooperstein, R., Vaturi, M., Bosak, E., Vered, Z., & AKSELROD, S. (1998) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(98)80019-2 · Cited by 43
Pinna, G. D., Rovere, M. T. L., Maestri, R., Mortara, A., Bigger, J. T., & Schwartz, P. J. (2000) · European Heart Journal · doi:10.1053/euhj.1999.1948 · Cited by 53
Noninvasive Cardiac Output by Partial CO2 Rebreathing after Severe Chest Trauma
Maxwell, R. A., Gibson, J. B., Slade, J. B., Fabian, T. C., & Proctor, K. G. (2001) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/00005373-200111000-00005 · Cited by 43
Prostaglandin E2in the expired breath condensate of patients with asthma
Κostikas, Κ., Papatheodorou, G. N., Psathakis, K., Panagou, P., & Loukides, S. (2003) · European Respiratory Journal · doi:10.1183/09031936.03.00000603 · Cited by 43
Interobserver test-retest reliability of the randot preschool stereoacuity test
Fawcett, S. L., & Birch, E. E. (2000) · Journal of American Association for Pediatric Ophthalmology and Strabismus · doi:10.1067/mpa.2000.110340 · Cited by 43
Accelerometry and Heart Rate as a Measure of Physical Fitness: Cross-Validation
PLASQUI, G., & WESTERTERP, K. R. (2006) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000228942.55152.84 · Cited by 43
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.