STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 18,301–18,400 of 47,868
Desflurane pharmacokinetics during cardiopulmonary bypass
Mets, B., Reich, N. T., Mellas, N., Beck, J., & Park, S. W. (2001) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/jcan.2001.21945 · Cited by 25
MRI of double-bundle ACL reconstruction: evaluation of graft findings
Kiekara, T., Järvelä, T., Huhtala, H., & Paakkala, A. (2011) · Skeletal Radiology · doi:10.1007/s00256-011-1285-1 · Cited by 25
Ellison, P., Sparks, S. A., Murphy, P. N., Carnegie, E., & Marchant, D. (2014) · Research in Sports Medicine · doi:10.1080/15438627.2013.852090 · Cited by 25
Chida, K., Ogasawara, K., Kuroda, H., Aso, K., Kobayashi, M., Fujiwara, S., Yoshida, K., Terasaki, K., & Ogawa, A. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.110.084186 · Cited by 25
Global End-Diastolic Volume During Different Loading Conditions in a Pediatric Animal Model
Renner, J., Meybohm, P., Gruenewald, M., Steinfath, M., Scholz, J., Boening, A., & Bein, B. (2007) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000281152.72734.d0 · Cited by 25
Thirty-minute compared to standardised office blood pressure measurement in general practice
Haan, N. S., van der Wel, M., Schoenmakers, G., Boudewijns, S., Peer, P. G. M., van Weel, C., Thien, T. A., & Bakx, C. (2011) · British Journal of General Practice · doi:10.3399/bjgp11x593875 · Cited by 25
Gupta, P., Sidhartha, E., Girard, M. J. A., Mari, J. M., Wong, T. Y., & Cheng, C. (2014) · PLoS ONE · doi:10.1371/journal.pone.0096661 · Cited by 26
Scalise, F., Farina, M., Manfredi, M., Auguadro, C., & Novelli, E. (2012) · Phlebology The Journal of Venous Disease · doi:10.1258/phleb.2012.012079 · Cited by 25
Hartlev, J., Kohberg, P., Ahlmann, S., Gotfredsen, E., Andersen, N. T., Isidor, F., & Schou, S. (2012) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2012.02442.x · Cited by 25
Kawahara, J., Tanaka, S., Tanaka, C., Aoki, Y., & Yonemoto, J. (2011) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2011.04.006 · Cited by 25
Guo, Y., Yang, Z., Ning, G., Rao, L., Dong, L., Pen, Y., Zhang, T., Wu, Y., Zhang, X., & Wang, Q. (2009) · European Radiology · doi:10.1007/s00330-009-1392-8 · Cited by 25
Photoplethysmographic and pulse pressure variations during abdominal surgery
Høiseth, L. Ø., Hoff, I. E., Skare, Ø., Kirkebøen, K. A., & Landsverk, S. A. (2011) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2011.02527.x · Cited by 25
Sladkevicius, P., & Valentin, L. (2012) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.12289 · Cited by 25
A new approach to reliability assessment of dental caries examinations
Altarakemah, Y. Y., Al‐Sane, M., Lim, S., Kingman, A., & Ismail, A. I. (2012) · Community Dentistry And Oral Epidemiology · doi:10.1111/cdoe.12020 · Cited by 32
Automatic tracking of labeled red blood cells in microchannels
Pinho, D., Lima, R. A., Pereira, A. I., & Gayubo, F. (2012) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.2526 · Cited by 25
Sevilla, R. S., Cruz, F., Chiu, C., Xue, D., Bettano, K. A., Zhu, J. J., Chakravarthy, K., Faltus, R., Wang, S., Vanko, A., et al. (2014) · Bone · doi:10.1016/j.bone.2014.11.014 · Cited by 25
Margulescu, A. D., Thomas, D. E., Ingram, T. E., Vintila, V., Egan, M. A., Vinereanu, D., & Fraser, A. G. (2010) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2010.01.008 · Cited by 26
Infrasonic cardiac signals: Complementary windows to cardiovascular dynamics
Tavakolian, K., Ngai, B., Blaber, A. P., & Kamińska, B. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091061 · Cited by 27
Validation of the Omron M7 and Microlife 3BTO-A Blood Pressure Measuring Devices in Preeclampsia
Nouwen, E., Snijder, M., van Montfrans, G. A., & Wolf, H. (2011) · Hypertension in Pregnancy · doi:10.3109/10641955.2010.544799 · Cited by 25
Elnakib, A. A., Beache, G. M., Gimel’farb, G., & El-Baz, A. S. (2011) · International journal of cardiac imaging · doi:10.1007/s10554-011-9991-2 · Cited by 25
Finch, N., Syme, H. M., Elliott, J., Peters, A. M., Gerritsen, R., Croubels, S., & Heiene, R. (2011) · American Journal of Veterinary Research · doi:10.2460/ajvr.72.12.1652 · Cited by 25
Skilton, M. R., Nakhla, S., Ayer, J. G., Harmer, J. A., Toelle, B. G., Leeder, S., Jones, G. J., Marks, G. B., Celermajer, D. S., & for the Childhood Asthma Prevention Study group (2015) · European Journal of Preventive Cardiology · doi:10.1177/2047487315607075 · Cited by 29
Factors affecting mechanical nociceptive thresholds in healthy sows
Nalon, E., Maes, D. G. D., Piepers, S., Taylor, P. M., van Riet, M. M., Janssens, G. P., Millet, S., & Tuyttens, F. (2015) · Veterinary Anaesthesia and Analgesia · doi:10.1111/vaa.12313 · Cited by 25
Kerklaan, D., Augustus, M. E., Hulst, J. M., van Rosmalen, J., Verbruggen, S. C. A. T., & Joosten, K. F. M. (2016) · Clinical Nutrition · doi:10.1016/j.clnu.2016.01.001 · Cited by 25
Interchangeability between Pentacam and IOLMaster in Phakic Intraocular Lens Calculation
Sayed, K. M., & Alsmman, A. H. (2014) · European Journal of Ophthalmology · doi:10.5301/ejo.5000524 · Cited by 25
Night-to-night variation of pulse oximetry in children with sleep-disordered breathing
Burke, R. M., Maxwell, B., Hunter, C., Graham, D., O’Donoghue, D., & Shields, M. D. (2016) · Archives of Disease in Childhood · doi:10.1136/archdischild-2015-308981 · Cited by 26
Hadeed, K., Hascoët, S., Amadieu, R., Karsenty, C., Cuttone, F., Léobon, B., Dulac, Y., & Acar, P. (2016) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2016.04.012 · Cited by 25
Richard, V., Lamberto, G., Lu, T., Cappozzo, A., & Dumas, R. (2016) · PLoS ONE · doi:10.1371/journal.pone.0157010 · Cited by 28
Yoo, H., Lee, J. M., Yoon, J. H., Lee, D. H., Chang, W., & Han, J. K. (2016) · Korean Journal of Radiology · doi:10.3348/kjr.2016.17.5.750 · Cited by 25
Yuan, J., Usman, A., Reid, S. A., King, K. F., Patterson, A. J., Gillard, J. H., & Graves, M. J. (2016) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2016.11.014 · Cited by 25
Remote sensing of physiological signs using a machine vision system
Al‐Naji, A., Gibson, K., & Chahl, J. (2017) · Journal of Medical Engineering & Technology · doi:10.1080/03091902.2017.1313326 · Cited by 25
Blaire, T., Bailliez, A., Bouallègue, F. B., Bellèvre, D., Agostini, D., & Manrique, A. (2017) · Journal of Nuclear Medicine · doi:10.2967/jnumed.117.194373 · Cited by 25
Thoracoabdominal asynchrony: Two methods in healthy, COPD, and interstitial lung disease patients
Pereira, M. C., Porras, D. C., Lunardi, A. C., da Silva, C. C. B. M., Barbosa, R. C. C., Cardenas, L. Z., Pletsch, R., Ferreira, J. G., de Castro, I., Carvalho, C. R. F., et al. (2017) · PLoS ONE · doi:10.1371/journal.pone.0182417 · Cited by 28
Al‐Naji, A., & Chahl, J. (2017) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2017.2757485 · Cited by 26
Pfau, M., Lindner, M., Steinberg, J. S., Thiele, S., Brinkmann, C. K., Fleckenstein, M., Holz, F. G., & Schmitz-Valckenberg, S. (2017) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2017-311012 · Cited by 25
Wang, H., Du, K. L., Qu, J., Chandarana, H., & Das, I. J. (2018) · PLoS ONE · doi:10.1371/journal.pone.0190883 · Cited by 25
Effect of local administration of simvastatin on postorthodontic relapse in a rabbit model
AlSwafeeri, H., El-Kenany, W. A., Mowafy, M. I., & Karam, S. S. (2018) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2017.10.024 · Cited by 25
Smith, M. P., Horsch, A., Standl, M., Heinrich, J., & Schulz, H. (2018) · Scientific Reports · doi:10.1038/s41598-018-33288-z · Cited by 36
Validation and Reliability of the French Version of the Sydney Swallow Questionnaire
Audag, N., Goubau, C., Danse, E. M., Vandervelde, L., Liistro, G., Toussaint, M., & Reychler, G. (2019) · Dysphagia · doi:10.1007/s00455-019-09978-9 · Cited by 27
Prado, A., Cao, X., Robert, M. T., Gordon, A. M., & Agrawal, S. K. (2019) · Physical Medicine and Rehabilitation Clinics of North America · doi:10.1016/j.pmr.2018.12.007 · Cited by 25
Bennett, L. D., Metz, G., Klein, M., Locke, K. G., Khwaja, A., & Birch, D. G. (2019) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.18-25473 · Cited by 25
Yano, S., Koohsari, M. J., Shibata, A., Ishii, K., Frehlich, L., McCormack, G. R., & Oka, K. (2019) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph16091597 · Cited by 26
Estimating personal exposures from a multi-hazard sensor network
Zuidema, C., Stebounova, L. V., Sousan, S., Gray, A., Stroh, O., Thomas, G. W., Peters, T. M., & Koehler, K. A. (2019) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/s41370-019-0146-1 · Cited by 25
Beretta-Piccoli, M., Cescon, C., Barbero, M., & D’Antona, G. (2019) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2019.06.005 · Cited by 27
Yamauchi, K., Suzuki, S., Kato, C., & Kato, T. (2019) · Annals of Physical and Rehabilitation Medicine · doi:10.1016/j.rehab.2019.06.018 · Cited by 31
Kox, L. S., Jens, S. R. J., Lauf, K., Smithuis, F. F., van Rijn, R. R., & Maas, M. M. (2019) · European Radiology · doi:10.1007/s00330-019-06354-x · Cited by 25
A near‐infrared fluorescent pH sensing film for wound milieu pH monitoring
Li, S., Vu, H., Senkowsky, J., Hu, W., & Tang, L. (2019) · Experimental Dermatology · doi:10.1111/exd.14046 · Cited by 26
Schantz, P., Eriksson, J. S., & Rosdahl, H. G. (2019) · European Journal of Applied Physiology · doi:10.1007/s00421-019-04236-0 · Cited by 26
Sleire, S. N., Aakre, I., Kjellevold, M., Dahl, L., Nerhus, I., Midtbø, L. K., & Markhus, M. W. (2019) · Nutrition Journal · doi:10.1186/s12937-019-0489-4 · Cited by 29
Machine learning derived input-function in a dynamic 18 F-FDG PET study of mice
Kuttner, S., Wickstrøm, K., Kalda, G., Dorraji, E., Martin‐Armas, M., Oteiza, A., Jenssen, R., Fenton, K. A., Sundset, R., & Axelsson, J. (2019) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/ab6496 · Cited by 31
New Predictive Equations for Resting Energy Expenditure in Normal to Overweight and Obese Population
Almajwal, A. M., & Abulmeaty, M. M. A. (2019) · International Journal of Endocrinology · doi:10.1155/2019/5727496 · Cited by 26
Automated Quantification of Blood Loss versus Visual Estimation in 274 Vaginal Deliveries
Rubenstein, A. F., Zamudio, S., Douglas, C., Sledge, S., & Thurer, R. L. (2020) · American Journal of Perinatology · doi:10.1055/s-0040-1701507 · Cited by 27
Konert, T., Everitt, S., Fontaine, M. D. L., van de Kamer, J. B., MacManus, M. P., Vogel, W. V., Callahan, J., & Sonke, J. (2020) · PLoS ONE · doi:10.1371/journal.pone.0228793 · Cited by 26
Sannachi, L., Gangeh, M. J., Naini, A. S., Bhargava, P., Jain, A., Tran, W. T., & Czarnota, G. J. (2020) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2020.01.022 · Cited by 25
Zimatore, G., Gallotta, M. C., Innocenti, L., Bonavolontá, V., Ciasca, G., Spirito, M. D., Guidetti, L., & Baldari, C. (2020) · Chaos An Interdisciplinary Journal of Nonlinear Science · doi:10.1063/1.5140455 · Cited by 27
Radar-Based Detection of Respiration Rate with Adaptive Harmonic Quefrency Selection
Lee, J., & Yoo, S. K. (2020) · Sensors · doi:10.3390/s20061607 · Cited by 25
von Treuheim, T. D. P., Torre, O. M., Mosley, G. E., Nasser, P. R., & Iatridis, J. C. (2020) · JOR Spine · doi:10.1002/jsp2.1088 · Cited by 34
Development and validation of a UPLC-MS/MS method to quantify fructose in serum and urine
Buziau, A. M., Scheijen, J. L. J. M., Stehouwer, C. D. A., Simons, N., Brouwers, M. C. G. J., & Schalkwijk, C. G. (2020) · Journal of Chromatography B · doi:10.1016/j.jchromb.2020.122299 · Cited by 25
Kangwanrattanakul, K. (2020) · Expert Review of Pharmacoeconomics & Outcomes Research · doi:10.1080/14737167.2021.1829479 · Cited by 26
Xie, X., Corradetti, G., Song, A. E., Pardeshi, A. A., Sultan, W., Lee, J. Y., Yu, F., Zhang, L., Chen, S., Chopra, V., et al. (2020) · PLoS ONE · doi:10.1371/journal.pone.0240110 · Cited by 26
Thiele, S., Isselmann, B., Pfau, M., Holz, F. G., Schmitz-Valckenberg, S., Wu, Z., Guymer, R. H., & Luu, C. D. (2020) · Translational Vision Science & Technology · doi:10.1167/tvst.9.11.17 · Cited by 25
Płoszczyca, K., Jazic, D., Piotrowicz, Z., Chalimoniuk, M., Langfort, J., & Czuba, M. (2020) · BMC Sports Science Medicine and Rehabilitation · doi:10.1186/s13102-020-00219-3 · Cited by 33
Obeid, H., Fortier, C., Garneau, C.-A., Paré, M., Boutouyrie, P., Bruno, R. M., Khettab, H., Goupil, R., & Agharazii, M. (2021) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00551.2020 · Cited by 31
Rueda, F. M., Fernández-González, P., Cuesta‐Gómez, A., Koutsou, A. D., Carratalá‐Tejada, M., & Miangolarra‐Page, J. C. (2021) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph18031343 · Cited by 27
Combret, Y., Boujibar, F., Gennari, C., Médrinal, C., Sicinski, S., Bonnevie, T., Gravier, F., Laurans, M., Marguet, C., Roux, P. L., et al. (2021) · PLoS ONE · doi:10.1371/journal.pone.0246781 · Cited by 27
Bravi, R., Caputo, S., Jayousi, S., Martinelli, A., Biotti, L., Nannini, I., Cohen, E. J., Quarta, E., Grasso, S., Lucchesi, G., et al. (2021) · Sensors · doi:10.3390/s21041057 · Cited by 28
Nasal ventilation and rapid maxillary expansion (RME): a randomized trial
Iwasaki, T., Papageorgiou, S. N., Yamasaki, Y., Darendeliler, M. A., & Papadopoulou, A. K. (2021) · European Journal of Orthodontics · doi:10.1093/ejo/cjab001 · Cited by 33
Janke, D., Kagelmann, N., Storm, C., Maggioni, M. A., Kienast, C., Gunga, H., & Opatz, O. S. (2021) · Frontiers in Medicine · doi:10.3389/fmed.2021.666908 · Cited by 25
Value CMR: Towards a Comprehensive, Rapid, Cost-Effective Cardiovascular Magnetic Resonance Imaging
Ibrahim, E. H., Frank, L., Baruah, D., Arpinar, V. E., Nencka, A. S., Koch, K. M., Muftuler, L. T., Ünal, O., Stojanovska, J., Rubenstein, J., et al. (2021) · International Journal of Biomedical Imaging · doi:10.1155/2021/8851958 · Cited by 28
Huss, A., Dongus, S., Aminzadeh, R., Thielens, A., den Bossche, M. V., Torre, P. V., de Sèze, R., Cardis, E., Eeftens, M., Joseph, W., et al. (2021) · Environment International · doi:10.1016/j.envint.2021.106711 · Cited by 26
Boyle, A. B., Namkung, S., Shew, W., Gokul, A., McGhee, C. N. J., & Ziaei, M. (2021) · PLoS ONE · doi:10.1371/journal.pone.0254832 · Cited by 25
Echocardiographic Reference Ranges of Non-invasive Myocardial Work Indices in Children
Pham, T. T. M., Truong, V. T., Vu, P. N., Tran, T. X., Nguyen, N. N. H., Nguyen, L. P. T., Tu, H. T. N., Palmer, C., Tretter, J. T., Levy, P. T., et al. (2021) · Pediatric Cardiology · doi:10.1007/s00246-021-02695-x · Cited by 27
Pereiro‐Buceta, H., Vallejo, R., Losa‐Iglesias, M. E., López‐López, D., Navarro‐Flores, E., Martínez‐Jiménez, E. M., Martiniano, J. M. C., & Calvo‐Lobo, C. (2021) · Healthcare · doi:10.3390/healthcare9080932 · Cited by 25
Dion, M.-O., Simonyan, D., Faure, P.-A., Pelet, S., May, O., Bonin, N., Carsen, S., Beaulé, P. E., Nault, M., & Belzile, É. L. (2021) · Orthopaedics & Traumatology Surgery & Research · doi:10.1016/j.otsr.2021.103083 · Cited by 26
Burma, J. S., Lapointe, A. P., Soroush, A., Oni, I. K., Smirl, J. D., & Dunn, J. F. (2021) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2021.103934 · Cited by 31
Kim, C., Lee, G., Oh, H., Jeong, G.-J., Kim, S. W., Chun, E. J., Kim, Y., Lee, J., & Yang, D. H. (2021) · European Radiology · doi:10.1007/s00330-021-08296-9 · Cited by 26
Syauqy, A., Afifah, D. N., Purwanti, R., Nissa, C., Fitranti, D. Y., & Chao, J. C.-J. (2021) · Nutrients · doi:10.3390/nu13114163 · Cited by 38
Estimating cardiac output from blood pressure and heart rate: the liljestrand & zander formula.
Koenig, J., Hill, L. K., Williams, D. P., & Thayer, J. F. (2015) · PubMed · Cited by 25
Yu, M., Ruan, J., Yang, B., Gao, Y., Jin, J., Dong, F., Ji, H., He, L., Cheng, G., & Gong, X. (2022) · European Radiology · doi:10.1007/s00330-022-08771-x · Cited by 26
Macarilla, C. T., Sautter, N. M., Robinson, Z. P., Juber, M. C., Hickmott, L. M., Cerminaro, R. M., Benitez, B., Carzoli, J. P., Bazyler, C. D., Zoeller, R. F., et al. (2022) · Journal of Human Kinetics · doi:10.2478/hukin-2022-0046 · Cited by 31
Ackermans, L. L. G. C., Volmer, L., Timmermans, Q. M. M. A., Brecheisen, R., Damink, S. W. M. O., Dekker, A. L. A. J., Loeffen, D. V., Poeze, M., Blokhuis, T. J., Wee, L., et al. (2022) · Injury · doi:10.1016/j.injury.2022.05.004 · Cited by 30
Liu, P., Fall, S., & Balédent, O. (2022) · NeuroImage · doi:10.1016/j.neuroimage.2022.119361 · Cited by 33
Kılınç, D. D., Kırcelli, B. H., Sadry, S., & Karaman, A. (2022) · Journal of Stomatology Oral and Maxillofacial Surgery · doi:10.1016/j.jormas.2022.07.017 · Cited by 25
Ritsche, P., Wirth, P., Cronin, N. J., Sarto, F., Narici, M. V., Faude, O., & Franchi, M. V. (2022) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000003010 · Cited by 29
Examination of a foot mounted IMU-based methodology for a running gait assessment
Young, F., Mason, R., Wall, C., Morris, R., Stuart, S., & Godfrey, A. (2022) · Frontiers in Sports and Active Living · doi:10.3389/fspor.2022.956889 · Cited by 25
Boeren, A. M. P., Niemantsverdriet, E., Verstappen, M., Wouters, F., Bloem, J. L., Reijnierse, M., & Mil, A. H. M. V. D. H. (2022) · Skeletal Radiology · doi:10.1007/s00256-022-04238-8 · Cited by 25
Alahmadi, M. A., Almasoud, K. H., Aljahani, A. H., Alzaman, N. S., Nozha, O. M. A., Alahmadi, O. M., Jalloun, R. A., Alfadhli, E. M., Alahmadi, J. M., Zuair, A. A., et al. (2023) · BMC Public Health · doi:10.1186/s12889-023-15030-1 · Cited by 29
Automatic range of motion measurement via smartphone images for telemedicine examination of the hand
Gu, F., Fan, J., Wang, Z., Liu, X., Yang, J., & Zhu, Q. (2023) · Science Progress · doi:10.1177/00368504231152740 · Cited by 27
Comparing Direct Measurements and Three-Dimensional (3D) Scans for Evaluating Facial Soft Tissue
Gašparović, B., Morelato, L., Lenac, K., Mauša, G., Zhurov, A. I., & Katić, V. (2023) · Sensors · doi:10.3390/s23052412 · Cited by 28
Validity of the International Physical Activity Questionnaire (short form) in adults with asthma
de Oliveira, J. M., Spositon, T., Rugila, D. F., Pitta, F. D. O., & Furlanetto, K. C. (2023) · PLoS ONE · doi:10.1371/journal.pone.0282137 · Cited by 26
Towards standardizing basophil identification by flow cytometry
Sønder, S. U., Plassmeyer, M. L., Loizou, D., & Alpan, O. (2023) · Frontiers in Allergy · doi:10.3389/falgy.2023.1133378 · Cited by 25
Casado-Robles, C., Mayorga-Vega, D., Guijarro-Romero, S., & Viciana, J. (2023) · Journal of Sports Science and Medicine · doi:10.52082/jssm.2023.196 · Cited by 34
Chen, X., Li, X., Wang, Y., & Lu, S. (2023) · Heliyon · doi:10.1016/j.heliyon.2023.e20764 · Cited by 29
Deep learning for automatic organ and tumor segmentation in nanomedicine pharmacokinetics
Dhaliwal, A. K., Ma, J., Zheng, M., Lyu, Q., Rajora, M. A., Ma, S., Oliva, L., Ku, A., Valic, M. S., Wang, B., et al. (2024) · Theranostics · doi:10.7150/thno.90246 · Cited by 25
Repeatability of Pentacam peripheral corneal thickness measurements
Martín, R., Jonuscheit, S., Río‐Cristóbal, A., & Doughty, M. J. (2015) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2015.05.001 · Cited by 25
Validity and reliability of a hand-held dynamometer for dynamic muscle strength assessment
Le-Ngoc, L., & Jansse, J. (2012) · InTech eBooks · doi:10.5772/37688 · Cited by 25
Comparison of the transcutaneous bilirubinometers BiliCheck and Minolta JM‐103 in preterm neonates
Ebbesen, F., Vandborg, P. K., & Trydal, T. (2012) · Acta Paediatrica · doi:10.1111/j.1651-2227.2012.02797.x · Cited by 25
Determining corneal power using Pentacam after myopic photorefractive keratectomy
Falavarjani, K. G., Hashemi, M., Joshaghani, M., Azadi, P., Ghaempanah, M. J., & Aghai, G. H. (2010) · Clinical and Experimental Ophthalmology · doi:10.1111/j.1442-9071.2010.02286.x · Cited by 25
Reliability of measures of transient evoked otoacoustic emissions with contralateral suppression
Stuart, A., & Cobb, K. M. (2015) · Journal of Communication Disorders · doi:10.1016/j.jcomdis.2015.09.003 · Cited by 25
Reliability of infrared ear thermometry in the prediction of rectal temperature in older inpatients
Smitz, S., de Winckel, A. V., & Smitz, M. (2009) · Journal of Clinical Nursing · doi:10.1111/j.1365-2702.2008.02565.x · Cited by 25
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.