STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 18,601–18,700 of 47,868
von Gersdorff, G. J. E., Kulig, B., Hensel, O., & Sturm, B. (2020) · Journal of Food Engineering · doi:10.1016/j.jfoodeng.2020.110419 · Cited by 25
Dynamic perfusion digital radiography for predicting pulmonary function after lung cancer resection
Hanaoka, J., Yoden, M., Hayashi, K., Shiratori, T., Okamoto, K., Kaku, R., Kawaguchi, Y., Ohshio, Y., & Sonoda, A. (2021) · World Journal of Surgical Oncology · doi:10.1186/s12957-021-02158-w · Cited by 25
Clinical target segmentation using a novel deep neural network: double attention Res-U-Net
Chenarlogh, V. A., Shabanzadeh, A., Oghli, M. G., Sirjani, N., Moghadam, S. F., Akhavan, A., Arabi, H., Shiri, I., Shabanzadeh, Z., Taheri, M. S., et al. (2022) · Scientific Reports · doi:10.1038/s41598-022-10429-z · Cited by 30
Kovalik, A. C., Bisetto, P., Pochapski, M. T., Campagnoli, E. B., Pilatti, G. L., & dos Santos, F. A. (2014) · Journal of Medicinal Food · doi:10.1089/jmf.2013.0001 · Cited by 25
Mahmoud, S., Hamad, F., Riaz, M. A., Ahmed, G., Dosari, M. A. A. A., & Ibrahim, T. (2015) · International Orthopaedics · doi:10.1007/s00264-015-2939-8 · Cited by 25
Müller, S., Baur, H., König, T., Hirschmüller, A., & Mayer, F. (2007) · Isokinetics and Exercise Science · doi:10.3233/ies-2007-0286 · Cited by 25
Demographics, management, and welfare of nonracing horses in Prince Edward Island.
Christie, J. L., Hewson, C. J., Riley, C. B., McNiven, M. A., Dohoo, I. R., & Bate, L. A. (2004) · Europe PMC (PubMed Central) · Cited by 28
Cerebral blood flow and oxygen metabolism measured with the Kety–Schmidt method using nitrous oxide
Taudorf, S., Berg, R. M. G., Bailey, D. M., & Møller, K. (2009) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2008.01788.x · Cited by 25
Y-Piece Temperature and Humidification During Mechanical Ventilation
Solomita, M., Daroowalla, F., Leblanc, D. S., & Smaldone, G. C. (2009) · Respiratory Care · doi:10.4187/respcare.09540480 · Cited by 25
Clinical evaluation of the Byk LIA-mat CA125 II assay: discussion of a reference value
Bonfrèr, J. M. G., Korse, C. M., Verstraeten, R. A., van Kamp, G. J., Hart, G. A. M., & Kenemans, P. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.3.491 · Cited by 25
Poller, L., Ibrahim, S., Keown, M., Pattison, A., & Jespersen, J. (2010) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2010.04109.x · Cited by 25
Theodorou, A. S., Havenetidis, K., Zanker, C. L., O'Hara, J. P., King, R. F. G. J., Hood, C., Paradisis, G., & Cooke, C. B. (2005) · The Journal of Strength and Conditioning Research · doi:10.1519/15314.1 · Cited by 25
Hervig, T. A., Haugen, T., Liseth, K., Kjeldsen‐Kragh, J., Scott, C. S., & Johannessen, B. (2004) · Vox Sanguinis · doi:10.1111/j.1423-0410.2004.00557.x · Cited by 25
Mori, S., Takaya, T., Kinugasa, M., Ito, T., Takamine, S., Fujiwara, S., Nishii, T., Kono, A. K., Inoue, T., Satomi‐Kobayashi, S., et al. (2014) · Atherosclerosis · doi:10.1016/j.atherosclerosis.2014.12.041 · Cited by 25
Feasibility and validity of a computer administered version of SEIQoL-DW
Ring, L., Lindblad, Å. K., Bendtsen, P., Viklund, E. W. E., Jansson, R., & Glimelius, B. L. G. (2006) · Quality of Life Research · doi:10.1007/s11136-006-0052-6 · Cited by 30
YAMASHITA, K., Ueyama, Y., MIYOSHI, K., IGARASHI, R., KUSHIRO, T., UMAR, M. A., & Muir, W. W. (2007) · Journal of Veterinary Medical Science · doi:10.1292/jvms.69.43 · Cited by 25
The characterization of small hypoattenuating renal masses on contrast-enhanced CT
Patel, N. S., Pōder, L., Wang, Z. J., Yeh, B. M., Qayyum, A., Jin, H., & Coakley, F. V. (2009) · Clinical Imaging · doi:10.1016/j.clinimag.2008.12.002 · Cited by 25
Validated Scales to Assess Adult Self-Efficacy to Eat Fruits and Vegetables
Mainvil, L. A., Lawson, R. W., Horwath, C. C., McKenzie, J. E., & Reeder, A. I. (2009) · American Journal of Health Promotion · doi:10.4278/ajhp.061221154 · Cited by 33
Watała, C. W., Uličná, O., Golański, J., Nocun, M., Waczulíková, I., Markuszewski, L., & Drzewoski, J. (2006) · Blood Coagulation & Fibrinolysis · doi:10.1097/01.mbc.0000203862.85610.ac · Cited by 29
Femur and humerus length in trisomy 21 fetuses at 11–14 weeks of gestation
Longo, D., Defigueiredo, D., Cicero, S., Sacchini, C., & Nicolaides, K. H. (2004) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.970 · Cited by 27
Han, Y., Osborn, E. A., Maron, M. S., Manning, W. J., & Yeon, S. B. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21958 · Cited by 25
Ultrasound Measurement of Total Body Fat in Obese Adolescents
Pineau, J., Lalys, L., Bocquet, M., Guihard-Costa, A.-M., Polak, M., Frelut, M., Pérès, G., & Dabbas, M. (2009) · Annals of Nutrition and Metabolism · doi:10.1159/000265849 · Cited by 25
Translation and Validation of the Danish Version of the Bournemouth Questionnaire
Hartvigsen, J., Lauridsen, H. H., Ekström, S., Nielsen, M. B., Lange, F., Kofoed, N., & Grunnet-Nilsson, N. (2005) · Journal of Manipulative and Physiological Therapeutics · doi:10.1016/j.jmpt.2005.06.012 · Cited by 27
Renal function in sick very low birthweight infants: 2. Urea and creatinine excretion.
Wilkins, B. H. (1992) · Archives of Disease in Childhood · doi:10.1136/adc.67.10_spec_no.1146 · Cited by 25
Eradi, B., Wright, J. W., Gibbons, N. J., Blackshaw, P. E., Perkins, A. C., Wakefield, J., Sithole, J., & Singh, S. J. (2006) · Journal of Pediatric Surgery · doi:10.1016/j.jpedsurg.2006.08.006 · Cited by 25
Validation of conventional 2D lateral cephalometry using 3D cone beam CT
Shaw, K., McIntyre, G. T., Mossey, P. A., Menhinick, A., & Thomson, D. J. (2013) · Journal of Orthodontics · doi:10.1179/1465313312y.0000000009 · Cited by 25
Kox, M., Pompe, J. C., van der Hoeven, J. G., Hoedemaekers, C., & Pickkers, P. (2011) · Clinical Science · doi:10.1042/cs20110027 · Cited by 29
Clinical evaluation of two novel biointact PTH(1–84) assays in hemodialysis patients
Hecking, M., Kainz, A., Bielesz, B. O., Plischke, M., Beilhack, G. F., Hörl, W. H., Sunder–Plassmann, G., & Bieglmayer, C. (2012) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2012.08.006 · Cited by 27
A Novel Noninvasive Ultrasonic Cardiac Output Monitor: Comparison With Cardiac Magnetic Resonance
Trinkmann, F., Doesch, C., Papavassiliu, T., Weissmann, J., Haghi, D., Gruettner, J., Schoenberg, S. O., Borggrefe, M. M., Kaden, J. J., & Saur, J. (2009) · Clinical Cardiology · doi:10.1002/clc.20612 · Cited by 25
Meek, D. W., Howell, T. A., & Phene, C. J. (2009) · Agronomy Journal · doi:10.2134/agronj2008.0180x · Cited by 25
Comrie, F., Masson, L. F., & McNeill, G. (2009) · Nutrition Journal · doi:10.1186/1475-2891-8-13 · Cited by 25
Schlögl, S., Andermann, P., Luster, M., Reiners, C., & Laßmann, M. (2006) · Thyroid · doi:10.1089/thy.2006.16.41 · Cited by 25
Protein binding of aspirin and salicylate measured by in vivo ultrafiltration*
Ghahramani, P., Rowland‐Yeo, K., Yeo, W. W., Jackson, P., & Ramsay, L. E. (1998) · Clinical Pharmacology & Therapeutics · doi:10.1016/s0009-9236(98)90160-6 · Cited by 25
Bolca, S., Huybrechts, I., Verschraegen, M., Henauw, S. D., & de Wiele, T. V. (2009) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph6010121 · Cited by 29
Using Artificial Intelligence to Predict the Equilibrated Postdialysis Blood Urea Concentration
Fernández, E. A., Valtuille, R., Willshaw, P., & Perazzo, C. A. (2001) · Blood Purification · doi:10.1159/000046955 · Cited by 29
Accuracy of three transcutaneous carbon dioxide monitors in critically ill children
Urbano, J., Cruzado, V., López‐Herce, J., del Castillo, J., Bellón, J. M., & Carrillo, Á. (2010) · Pediatric Pulmonology · doi:10.1002/ppul.21203 · Cited by 25
Continuous monitoring of upper-limb activity in a free-living environment: a validation study
Vega‐González, A., Bain, B., Dall, P., & Granat, M. H. (2007) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-007-0233-7 · Cited by 25
Back to basics: Estimating energy requirements for adult hospital patients
Ferrie, S., & Ward, M. L. (2007) · Nutrition & Dietetics · doi:10.1111/j.1747-0080.2007.00124.x · Cited by 28
Amoore, J., Vacher, E., Murray, I. C., Mieke, S., King, S. T., Smith, F. E., & Murray, A. (2006) · Blood Pressure Monitoring · doi:10.1097/01.mbp.0000200482.72410.e2 · Cited by 25
The Norwegian office-, home-, and ambulatory blood pressure study (NOHA)
Omvik, P., & Gerhardsen, G. (2003) · Blood Pressure · doi:10.1080/08037050310015863 · Cited by 27
Diehm, Baumgärtner, Silvestro, Herrmann, Triller, Schmidli, Dai-Do, & Dinkel (2005) · VASA · doi:10.1024/0301-1526.34.4.255 · Cited by 25
Clinical Evaluation of the ABL-77 for Point-of-Care Analysis in the Cardiovascular Operating Room
Prichard, J. S., French, J. S., & Alvar, N. (2006) · Journal of ExtraCorporeal Technology · doi:10.1051/ject/200638128 · Cited by 25
Villaça, D. S., Lerario, M. C., Corso, S. D., Nápolis, L. M., de Albuquerque, A. L. P., Lazaretti‐Castro, M., Sachs, A., Nery, L. E., & Neder, J. A. (2008) · British Journal Of Nutrition · doi:10.1017/s0007114507886399 · Cited by 29
Johnson, L., & Selfe, J. (2004) · Physiotherapy · doi:10.1016/j.physio.2004.01.004 · Cited by 25
Xue, Q., Wu, X., Jin, J., Yu, B., & Zheng, M. (2010) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181e30b54 · Cited by 25
Jensen, M. B., Hermann, A. P., Hessov, I., & Mosekilde, L. (1997) · Clinical Nutrition · doi:10.1016/s0261-5614(97)80024-6 · Cited by 28
Ngoyi, D. M., Menten, J., Pyana, P. P., Büscher, P., & Lejon, V. (2013) · Tropical Medicine & International Health · doi:10.1111/tmi.12102 · Cited by 25
Chen, A., & O'leary, A. P. D. J. (1998) · Clinical and Experimental Optometry · doi:10.1111/j.1444-0938.1998.tb06628.x · Cited by 25
Hardelid, P., Williams, D. M., Dezateux, C. A., Cubitt, W. D., Peckham, C. S., Tookey, P. A., & Cortina‐Borja, M. (2007) · Journal of Medical Virology · doi:10.1002/jmv.21077 · Cited by 25
Accuracy of a digital skinfold system for measuring skinfold thickness and estimating body fat
do Amaral, T. F., Restivo, M. T., Guerra, R. S., Marques, E. A., Chousal, M. D. F., & Mota, J. A. P. S. (2010) · British Journal Of Nutrition · doi:10.1017/s0007114510003727 · Cited by 27
Thumboo, J., Fong, K., Chan, S. P., Leong, K., Feng, P.-H., Thio, S.-T., & Ml, B. (1999) · Lupus · doi:10.1191/096120399678840747 · Cited by 25
Clinical evaluation of the CA530‐VET hematology analyzer for use in veterinary practice
Roleff, S., Arndt, G., Bottema, B., Junker, L., Grabner, A., & Kohn, B. (2007) · Veterinary Clinical Pathology · doi:10.1111/j.1939-165x.2007.tb00202.x · Cited by 25
Lee, C. G., Park, H. M., Shin, H. J., Moon, J. S., Hong, Y. M., Kim, N. S., Ha, I. S., Chang, M. J., & Oh, K. W. (2011) · Korean Journal of Pediatrics · doi:10.3345/kjp.2011.54.11.463 · Cited by 25
Sillah, K. (2010) · World Journal of Gastrointestinal Oncology · doi:10.4251/wjgo.v2.i4.197 · Cited by 25
Redfearn, D., Skanes, A. C., Gula, L. J., GRIFFITH, M. J., Marshall, H. J., Stafford, P. J., Krahn, A. D., Yee, R. K., & Klein, G. J. (2007) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2007.00182.x · Cited by 27
Reliability and Consistency of Dark-Adapted Psychophysical Measures in Advanced Eye Disease
Bittner, A. K., Mladenovich, D., Eshraghi, F., Bourdeau, D., & Dagnelie, G. (2005) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.04-1146 · Cited by 27
van der Linden, M. L., Aitchison, A. M., Hazlewood, M. E., Hillman, S. J., & Robb, J. (2004) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2003.12.037 · Cited by 25
Hagishima, M., Kamiya, K., Fujimura, F., Morita, T., Shoji, N., & Shimizu, K. (2009) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-009-1202-7 · Cited by 25
Prins, S. A., de Hoog, M., Blok, J. H., Tibboel, D., & Visser, G. H. (2007) · Critical Care · doi:10.1186/cc6138 · Cited by 25
Quality Control, Quality Assurance, and Proficiency Testing in the Andrology Laboratory
Keel, B. A. (2002) · Archives of Andrology · doi:10.1080/01485010290099147 · Cited by 27
Hudson, T., Forman, M. R., Cantwell, M. M., Schatzkin, A. G., Albert, P. S., & Lanza, E. (2006) · Journal of the American College of Nutrition · doi:10.1080/07315724.2006.10719548 · Cited by 28
Noninvasive determination of upper airway resistance and flow limitation
Mansour, K. F., Rowley, J. A., & Badr, M. S. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01319.2003 · Cited by 28
Mistry, H., Buxton, M. J., Longworth, L., Chatwin, J., Peveler, R., & on behalf of the Assessing Health Economics of Antidepressants (AHEAD) Team (2005) · The European Journal of Health Economics · doi:10.1007/s10198-005-0300-7 · Cited by 25
McCollum, A. G. H., Dancaster, J. T., Evans, W. G., & Becker, P. J. (2009) · Seminars in Orthodontics · doi:10.1053/j.sodo.2009.03.003 · Cited by 25
Li, P.-N., Li, H., Wu, M., Wang, S., Kong, Q., Zhang, Z., Sun, Y., Liu, J., & Lv, D. (2012) · PLoS ONE · doi:10.1371/journal.pone.0038069 · Cited by 25
Ramírez, E., Valencia, M. E., Moya-Camarena, S. Y., Alemán-Mateo, H., & Estrada, R. O. M. (2008) · Nutrition · doi:10.1016/j.nut.2008.08.007 · Cited by 31
Agreement between methods of measurement of mean aortic wall thickness by MRI
Rosero, E. B., Peshock, R. M., Khera, A., Clagett, G. P., Lo, H. S., & Timaran, C. H. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21697 · Cited by 25
Differences between Recognition and Resolution Acuity in Patients Undergoing Macular Hole Surgery
Wittich, W., Overbury, O., Kapusta, M. A., & Watanabe, D. H. (2006) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.05-1307 · Cited by 25
Bardsley, P. A., Bentley, S., Hall, H. S., Singh, S., Evans, D., & Morgan, M. D. (1993) · Thorax · doi:10.1136/thx.48.4.354 · Cited by 25
Pulmonary gas transfer in children and adolescents born extremely preterm
Satrell, E., Røksund, O. D., Thorsen, E., & Halvorsen, T. (2012) · European Respiratory Journal · doi:10.1183/09031936.00027112 · Cited by 25
Lievers, W. B., Lee, V., Arsenault, S. M., Waldman, S. D., & Pilkey, A. K. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.09.002 · Cited by 25
van Prehn, J., Muhs, B. E., Pramanik, B. K., Ollenschleger, M. D., Rockman, C. R., Cayne, N. S., Adelman, M. A., Jacobowitz, G. R., & Maldonado, T. S. (2008) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2008.04.016 · Cited by 25
van der Heijde, D. M. F. M., & Landewé, R. (2003) · Annals of the Rheumatic Diseases · doi:10.1136/ard.62.suppl_2.ii10 · Cited by 25
Marini, R. P. (2001) · Journal of the American Society for Horticultural Science · doi:10.21273/jashs.126.4.503 · Cited by 25
Júnior, J. C. D. F., Lopes, A. D. S., Florindo, A. A., & Hallal, P. C. (2010) · Cadernos de Saúde Pública · doi:10.1590/s0102-311x2010000900002 · Cited by 55
Hove, M. N., Kristensen, J. K., Lauritzen, T., & Bek, T. (2004) · Acta Ophthalmologica Scandinavica · doi:10.1111/j.1600-0420.2004.00364.x · Cited by 25
Goodrich, S., & Orr, W. C. (2008) · Sleep Medicine · doi:10.1016/j.sleep.2007.11.003 · Cited by 28
Assessing Reliability of Measurement of Gait Velocity
Batey, P., Rome, K., Finn, P., & Hanchard, N. C. A. (2003) · Physiotherapy · doi:10.1016/s0031-9406(05)60044-2 · Cited by 25
Newby, D. E., Witherow, F. N., Wright, R. A., Bloomfield, P., Ludlam, C. A., Boon, N. A., Fox, K. A. A., & Webb, D. J. (2002) · Heart · doi:10.1136/heart.87.1.48 · Cited by 25
Monitoring Hyperhydration during High-Dose Chemotherapy: Body Weight or Fluid Balance?
Mank, A. P. M., Goossens, A., der Lelie, J. V., Bakker, P. J. M., & de Vos, R. (2003) · Acta Haematologica · doi:10.1159/000070964 · Cited by 25
Acierno, M. J., Mitchell, M. A., Schuster, P. J., Freeman, D. E., Guzman, D. S.-M., & Tully, T. N. (2009) · American Journal of Veterinary Research · doi:10.2460/ajvr.70.2.172 · Cited by 29
Automated measurement of skin prick tests: an advance towards exact calculation of wheal size
Wöhrl, S., Vigl, K., Binder, M., Stingl, G., & Prinz, M. (2006) · Experimental Dermatology · doi:10.1111/j.1600-0625.2006.00388.x · Cited by 25
Topeli̇, A., Laghi, F. A., & Tobin, M. J. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.160.4.9806041 · Cited by 25
The validation of the Subjective Index of Physical and Social Outcome (SIPSO)
Trigg, R., & WOOD, V. A. (2003) · Clinical Rehabilitation · doi:10.1191/0269215503cr609oa · Cited by 25
Amenábar, J. M., Martins, G. B., Cherubini, K., & de Figueiredo, M. A. Z. (2006) · Journal of Oral Science · doi:10.2334/josnusd.48.139 · Cited by 30
Poole, D. W., Cowan, D., & Smith, G. C. (2003) · Wildlife Research · doi:10.1071/wr02014 · Cited by 25
Davison, S. L., Bell, R. J., Montalto, J., Sikaris, K. A., Donath, S. M., Stanczyk, F. Z., & Davis, S. R. (2005) · Fertility and Sterility · doi:10.1016/j.fertnstert.2005.05.058 · Cited by 25
A comparison of weighed and recalled intakes for schoolchildren and mothers in rural Kenya
Gewa, C., Murphy, S. P., & Neumann, C. G. (2008) · Public Health Nutrition · doi:10.1017/s1368980008003698 · Cited by 31
Franssens, B. T., Eikendal, A. L. M., Leiner, T., van der Graaf, Y., Visseren, F. L. J., & Hoogduin, J. M. (2015) · NMR in Biomedicine · doi:10.1002/nbm.3444 · Cited by 31
Aging and spectral characteristics of the nonharmonic component of 24-h heart rate variability
Sakata, S., Hayano, J., Mukai, S., Okada, A., & Fujinami, T. (1999) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.1999.276.6.r1724 · Cited by 25
A comparison of deconvolution and the Patlak-Rutland plot in renography analysis.
Fleming, J. S., & Kemp, P. M. (1999) · PubMed · Cited by 25
Bosca, R., & Jackson, E. F. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/2/974 · Cited by 26
Agreement between Two Plasma Bicarbonate Assays in Critically Ill Patients
Story, D., & Poustie, S. (2000) · Anaesthesia and Intensive Care · doi:10.1177/0310057x0002800407 · Cited by 25
Akins, J. S., Vallely, J. J., Karg, P. E., Kopplin, K. J., Gefen, A., Poojary‐Mazzotta, P., & Brienza, D. M. (2016) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2016.04.026 · Cited by 26
Blood perfusion in osteomyelitis studied with [15O]water PET in a juvenile porcine model
Jødal, L., Nielsen, O. L., Afzelius, P., Alstrup, A. K. O., & Hansen, S. B. (2017) · EJNMMI Research · doi:10.1186/s13550-016-0251-2 · Cited by 25
Wettstein, M., Wahl, H., & Heyl, V. (2017) · Ear and Hearing · doi:10.1097/aud.0000000000000531 · Cited by 26
Brouwer, D. (2000) · The Annals of Occupational Hygiene · doi:10.1016/s0003-4878(00)00049-1 · Cited by 25
Darasz, K. H., Underwood, S. R., Bayliss, J., Forbat, S. M., Keegan, J., Poole-Wilson, P. A., & Sutton, G. C. (2002) · International journal of cardiac imaging · doi:10.1023/a:1014685430873 · Cited by 25
Respiratory resistance by end-inspiratory occlusion and forced oscillations in intubated patients
Beydon, L., Malassiné, P., Lorino, A. M., Mariette, C., Bonnet, F. J., HARF, A., & LORINO, H. (1996) · Journal of Applied Physiology · doi:10.1152/jappl.1996.80.4.1105 · Cited by 25
The Trough-to-Peak Ratio as an Instrument to Evaluate Antihypertensive Drugs
Staessen, J. A., Bieniaszewski, L., Buntinx, F., Celis, H., O'Brien, E. T., Hoof, R. V., & Fagard, R. H. (1995) · Hypertension · doi:10.1161/01.hyp.26.6.942 · Cited by 25
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.