STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 18,801–18,900 of 47,868
A Comparison of Two Methods to Assess the Usage of Mobile Hand-Held Communication Devices
Berolo, S., Steenstra, I. A., Amick, B. C., & Wells, R. P. (2014) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2014.973111 · Cited by 25
MARTIN, D. J., & Wright, J. (2008) · Social Science & Medicine · doi:10.1016/j.socscimed.2008.10.021 · Cited by 24
Scansen, B. A., Vitt, J. P., Chew, D. J., Schober, K. E., & Bonagura, J. D. (2014) · Journal of Veterinary Internal Medicine · doi:10.1111/jvim.12289 · Cited by 27
Non-invasive computer-assisted measurement of knee alignment
Clarke, J., Riches, P. E., Picard, F., & Deakin, A. H. (2011) · Computer Aided Surgery · doi:10.3109/10929088.2011.635217 · Cited by 24
Noack, T., Mukherjee, C., Kiefer, P., Emrich, F. C., Vollroth, M., Ionasec, R. I., Voigt, I., Houle, H. C., Ender, J. K., Misfeld, M., et al. (2014) · Interactive Cardiovascular and Thoracic Surgery · doi:10.1093/icvts/ivu357 · Cited by 24
Langton, C. M., Wille, M., & Flegg, M. B. (2014) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411914523582 · Cited by 24
Schattke, S., Wagner, M., Hättasch, R., Schroeckh, S., Durmus, T., Schimke, I., Sanad, W., Spethmann, S., Scharhag, J., Huppertz, A., et al. (2012) · Cardiovascular Ultrasound · doi:10.1186/1476-7120-10-6 · Cited by 28
Yeom, E., Nam, K.-H., Paeng, D., & Lee, S.-J. (2014) · Ultrasonics · doi:10.1016/j.ultras.2014.04.017 · Cited by 24
Xanthis, C. G., Bidhult, S. L., Kantasis, G., Heiberg, E., Arheden, H., & Aletras, A. H. (2015) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-015-0206-1 · Cited by 24
Yu, A., Zhao, W., Savini, G., Huang, Z., Bao, F., Lu, W., Wang, Q., & Huang, J. (2015) · Journal of Ophthalmology · doi:10.1155/2015/767012 · Cited by 24
Großer, O. S., Kupitz, D., Ruf, J., Czuczwara, D., Steffen, I. G., Furth, C., Thormann, M., Loewenthal, D., Ricke, J., & Amthauer, H. (2015) · PLoS ONE · doi:10.1371/journal.pone.0138658 · Cited by 25
Aslam, T. M., Parry, N. R. A., Murray, I. J., Salleh, M. M., Col, C. D., Mirza, N., Czanner, G., & Tahir, H. J. (2016) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-016-3293-2 · Cited by 24
Aquila, I., Gonzalez, A. M. M., Fernández‐Golfín, C., Rincon, L. M., Casas, E., García, A., Hinojar, R., Jimenez-Nacher, J. J., & Zamorano, J. L. (2015) · Cardiovascular Ultrasound · doi:10.1186/s12947-016-0061-8 · Cited by 25
The Accuracy and Reproducibility of Linear Measurements Made on CBCT-derived Digital Models
Hajeer, M. Y., Maroua, A. L., & Ajaj, M. A. (2016) · The Journal of Contemporary Dental Practice · doi:10.5005/jp-journals-10024-1844 · Cited by 27
Tan, S., Yu, M., Baig, N., Hansapinyo, L., & Tham, C. C. Y. (2017) · Scientific Reports · doi:10.1038/srep42067 · Cited by 24
Ahn, S. J., Lee, J. M., Chang, W., Lee, S. M., Kang, H., Yang, H. K., Yoon, J. H., Park, S., & Han, J. K. (2017) · Korean Journal of Radiology · doi:10.3348/kjr.2017.18.6.926 · Cited by 26
RCAT reflects symptom control and quality of life in allergic rhinoconjunctivitis patients
Liedtke, J.-P., Mandl, A., Köther, J., Chwieralski, J., Shah‐Hosseini, K., Raskopf, E., Pieper‐Fürst, U., Allekotte, S., & Mösges, R. (2017) · Allergy · doi:10.1111/all.13362 · Cited by 27
Physiological Data Validation of the Hexoskin Smart Textile
Cherif, N., Mezghani, N., Gaudreault, N., Ouakrim, Y., Mouzoune, I., & Boulay, P. (2018) · International Joint Conference on Biomedical Engineering Systems and Technologies (BIOSTEC) · doi:10.5220/0006588001500156 · Cited by 31
Determining gestational age and preterm birth in rural Guatemala: A comparison of methods
Weinstein, J. R., Thompson, L. M., Díaz-Artiga, A., Bryan, J. P., Arriaga, W. E., Omer, S. B., & McCracken, J. P. (2018) · PLoS ONE · doi:10.1371/journal.pone.0193666 · Cited by 27
Hybrid Diffuse Reflectance Spectroscopy: Non-Erythemal in vivo Testing of Sun Protection Factor
Rohr, M., Ernst, N., & Schrader, A. (2018) · Skin Pharmacology and Physiology · doi:10.1159/000488249 · Cited by 24
Luchi, N., Pepori, A. L., Bartolini, P., Ioos, R., & Santini, A. (2018) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-018-9184-1 · Cited by 25
Anderson, B., Belcher, C., Slack, J., & Gelsleichter, J. (2018) · Journal of Fish Biology · doi:10.1111/jfb.13831 · Cited by 25
Zoch-Lesniak, B., Ware, R. S., Grimwood, K., & Lambert, S. B. (2018) · Journal of the Pediatric Infectious Diseases Society · doi:10.1093/jpids/piy136 · Cited by 24
Balloch, A., Meghji, M., Newton, R. U., Hart, N. H., Weber, J. A., Ahmad, I., & Habibi, D. (2019) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000003064 · Cited by 28
Measurement Repeatability of18F-FDG PET/CT Versus18F-FDG PET/MRI in Solid Tumors of the Pelvis
Fraum, T. J., Fowler, K. J., Crandall, J. P., Laforest, R. A., Salter, A. R., An, H., Jacobs, M. A., Grigsby, P. W., Dehdashti, F., & Wahl, R. L. (2019) · Journal of Nuclear Medicine · doi:10.2967/jnumed.118.218735 · Cited by 24
Evaluating the Sensoria Smart Socks Gait Monitoring System for Rehabilitation Outcomes
Yeung, J., Catolico, D., Fullmer, N. H., Daniel, R., Lovell, R., Tang, R., Pearson, E. M., & Rosenberg, S. (2019) · PM&R · doi:10.1002/pmrj.12003 · Cited by 27
Werner, C., Chalvatzaki, G., Papageorgiou, X. S., Tzafestas, C. S., Bauer, J. M., & Hauer, K. A. (2019) · Clinical Rehabilitation · doi:10.1177/0269215519852143 · Cited by 24
Dini, P., Troch, L., Lemahieu, I., Deblende, P., & Daels, P. F. (2019) · Reproduction in Domestic Animals · doi:10.1111/rda.13487 · Cited by 24
Feasibility and Reliability of Physical Fitness Tests among Colombian Preschool Children
Amado-Pacheco, J., Prieto‐Benavides, D. H., Correa‐Bautista, J. E., García‐Hermoso, A., Agostinis‐Sobrinho, C., Alonso-Martínez, A. M., Izquierdo, M., & Ramírez‐Vélez, R. (2019) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph16173069 · Cited by 30
Comparison of different methods of measuring angle of progression in prediction of labor outcome
Frick, A., Kostiv, V., Vojtassakova, D., Akolekar, R., & Nicolaides, K. H. (2019) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.21913 · Cited by 24
A comparison of methods to determine patent foramen ovale size
Kumar, P., Rusheen, J., & Tobis, J. M. (2019) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.28665 · Cited by 24
Cambridge Colour Test: reproducibility in normal trichromats
Fernandes, T. P., dos Santos, N. A., & Paramei, G. V. (2020) · Journal of the Optical Society of America A · doi:10.1364/josaa.380306 · Cited by 24
Quantification of surface iridescence in meat products by digital image analysis
Ruedt, C., Gibis, M., & Weiß, J. (2020) · Meat Science · doi:10.1016/j.meatsci.2020.108064 · Cited by 24
Weaver, L. N., & Wilson, G. P. (2020) · Journal of Mammalogy · doi:10.1093/jmammal/gyaa029 · Cited by 26
Basher, A., Kim, B. C., Lee, K. H., & Jung, H. Y. (2020) · IEEE Access · doi:10.1109/access.2020.2994388 · Cited by 25
Martín‐Fernández, J., Morey-Montalvo, M., Tomás-García, N., Martín-Ramos, E., Muñoz-García, J. C., Polentinos-Castro, E., Rodríguez-Martínez, G., Arenaza, J. C., García‐Pérez, L., Magdalena-Armas, L., et al. (2020) · Health and Quality of Life Outcomes · doi:10.1186/s12955-020-01435-8 · Cited by 30
Thöne, A., Görtz‐Dorten, A., Altenberger, P., Dose, C., Geldermann, N., Hautmann, C., Jendreizik, L. T., Treier, A., von Wirth, E., Banaschewski, T., et al. (2020) · Frontiers in Psychology · doi:10.3389/fpsyg.2020.01840 · Cited by 32
Magnitude and Variability of Stroke Patient-Proxy Disagreement Across Multiple Health Domains
Lapin, B. R., Thompson, N. R., Schuster, A. T., & Katzan, I. L. (2020) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2020.09.378 · Cited by 25
Pietton, R., David, M., Hisaund, A., Langlais, T., Skalli, W., Vialle, R., & Vergari, C. (2020) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2020.09.011 · Cited by 24
Fedewa, M. V., Sullivan, K. W., Hornikel, B., Holmes, C. J., Metoyer, C. J., & Esco, M. R. (2020) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000002550 · Cited by 26
Besler, B. A., Michalski, A. S., Kuczynski, M. T., Abid, A., Forkert, N. D., & Boyd, S. K. (2020) · Medical Image Analysis · doi:10.1016/j.media.2020.101887 · Cited by 28
Reliability and diagnostic performance of a new blood ketone and glucose meter in humans
Moore, A. R., Holland, A. M., Ansley, J., Boone, E. D. H., & Schulte, M. K. O. (2021) · Journal of the International Society of Sports Nutrition · doi:10.1186/s12970-020-00404-2 · Cited by 28
Bahrami, H. S. Z., Pedersen, F. H. G., Myhr, K. A., Møgelvang, R., & Hassager, C. (2021) · International journal of cardiac imaging · doi:10.1007/s10554-020-02069-z · Cited by 24
Assessing visual search performance using a novel dynamic naturalistic scene
Bennett, C. R., Bex, P. J., & Merabet, L. B. (2021) · Journal of Vision · doi:10.1167/jov.21.1.5 · Cited by 26
Burma, J. S., Macaulay, A., Copeland, P. V., Khatra, O., Bouliane, K. J., & Smirl, J. D. (2021) · Physiological Reports · doi:10.14814/phy2.14695 · Cited by 26
Bulamu, N. B., Vissapragada, R., Chen, G., Ratcliffe, J., Mudge, L. A., Smithers, B. M., Isenring, E. A., Smith, L. T., Jamieson, G. G., Watson, D. I., et al. (2021) · Health and Quality of Life Outcomes · doi:10.1186/s12955-021-01867-w · Cited by 25
Chen, Y., Ying, C., Binkley, M. M., Juttukonda, M. R., Flores, S. E., Laforest, R. A., Benzinger, T. L. S., & An, H. (2021) · Magnetic Resonance in Medicine · doi:10.1002/mrm.28689 · Cited by 27
Thermal Infrared Video Stabilization for Aerial Monitoring of Active Wildfires
Valero, M. M., Verstockt, S., Butler, B. W., Jiménez, D. M., Rios, O., Mata, C., Queen, L. P., Pastor, E., & Planas, E. (2021) · IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing · doi:10.1109/jstars.2021.3059054 · Cited by 27
Dion, M.-O., Faure, P.-A., May, O., Bonin, N., Beaulé, P. E., Carsen, S., Nault, M., Pelet, S., Simonyan, D., & Belzile, É. L. (2021) · Orthopaedics & Traumatology Surgery & Research · doi:10.1016/j.otsr.2021.102858 · Cited by 25
Tañá-Sanz, P., Ruiz-Santos, M., Rodríguez-Carrillo, M. D., Aguilar-Córcoles, S., Montés‐Micó, R., & Tañá‐Rivero, P. (2021) · Expert Review of Medical Devices · doi:10.1080/17434440.2021.1905518 · Cited by 24
Marra, M., Vincenzo, O. D., Cioffi, I., Sammarco, R., Morlino, D., & Scalfi, L. (2021) · Journal of the International Society of Sports Nutrition · doi:10.1186/s12970-021-00465-x · Cited by 27
Zhang, X., Mo, Y., Yan, C., Li, Y., & Li, H. (2021) · Quality of Life Research · doi:10.1007/s11136-021-02820-6 · Cited by 27
Ruiz‐García, I., Navarro-Marchal, I., Ocaña-Wilhelmi, J., Palma, A. J., Gómez-López, P. J., & Carvajal, M. A. (2021) · Sensors · doi:10.3390/s21072480 · Cited by 25
Validity and Test-retest Reliability of the Jumpo App for Jump Performance Measurement
Vieira, A., Blazevich, A. J., Costa, A. S. D., Tufano, J. J., & Bottaro, M. (2021) · International journal of exercise science · doi:10.70252/ltav3104 · Cited by 24
Quast, A., Santander, P., Kahlmeier, T., Moser, N., Schliephake, H., & Meyer‐Marcotty, P. (2021) · Head & Face Medicine · doi:10.1186/s13005-021-00279-x · Cited by 24
Chery, E., Slabbekoorn, J., Pinho, N., Miller, A., & Beyne, E. (2021) · IEEE Electronic Components and Technology Conference (ECTC) · doi:10.1109/ectc32696.2021.00064 · Cited by 24
Validity of a Magnet-Based Timing System Using the Magnetometer Built into an IMU
Buxadé, C. P.-C., Fernández-Valdés, B., Morral-Yepes, M., Viñas, S. T., Riu, J. M., & Moras, G. (2021) · Sensors · doi:10.3390/s21175773 · Cited by 24
Schiefer, L. M., Treff, G., Treff, F., Schmidt, P., Schäfer, L., Niebauer, J., Swenson, K. E., Swenson, E. R., Berger, M. M., & Sareban, M. (2021) · Sensors · doi:10.3390/s21196363 · Cited by 29
A Scoping Review of Methods Used to Assess Medication Adherence in Patients with Chronic Conditions
Konstantinou, P., Kasinopoulos, O., Karashiali, C., Georgiou, G., Panayides, A. S., Papageorgiou, A., Wozniak, G., Kassianos, A. P., & Karekla, M. (2021) · Annals of Behavioral Medicine · doi:10.1093/abm/kaab080 · Cited by 25
Recurrence quantification analysis of heart rate variability to detect both ventilatory thresholds
Zimatore, G., Falcioni, L., Gallotta, M. C., Bonavolontá, V., Campanella, M., Spirito, M. D., Guidetti, L., & Baldari, C. (2021) · PLoS ONE · doi:10.1371/journal.pone.0249504 · Cited by 28
Pate, J. W., Simons, L. E., Rush, G. Q., Hancock, M. J., Hush, J. M., Verhagen, A. P., & Pacey, V. (2021) · Clinical Journal of Pain · doi:10.1097/ajp.0000000000000990 · Cited by 25
The validity of point of care tear film osmometers in the diagnosis of dry eye
Tavakoli, A., Markoulli, M. P., Flanagan, J., & PAPAS, E. B. (2021) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12901 · Cited by 25
Sasaki, Y., Sato, K., Kobayashi, S., & Asakura, K. (2021) · JMIR Formative Research · doi:10.2196/31875 · Cited by 28
Xiao, Z., Sun, X., Zhaxi, D., Zhang, F., Ji, Y., Cheng, T., Li, X., & Xu, X. (2021) · Frontiers in Nutrition · doi:10.3389/fnut.2021.743896 · Cited by 28
Bouillod, A., Soto-Romero, G., Grappe, F., Bertucci, W., Brunet, E., & Cassirame, J. (2022) · Sensors · doi:10.3390/s22010386 · Cited by 36
Dynamic body acceleration as a proxy to predict the cost of locomotion in bottlenose dolphins
Allen, A. S., Read, A. J., Shorter, K. A., Gabaldon, J., Blawas, A. M., Rocho‐Levine, J., & Fahlman, A. (2022) · Journal of Experimental Biology · doi:10.1242/jeb.243121 · Cited by 28
Linking Function and Structure with ReSensNet
Seeböck, P., Vogl, W., Waldstein, S. M., Orlando, J. I., Baratsits, M., Alten, T., Arikan, M., Mylonas, G., Bogunović, H., & Schmidt-Erfurth, U. M. (2022) · Ophthalmology Retina · doi:10.1016/j.oret.2022.01.021 · Cited by 25
Rivera, P. N. C., Goldstein, R. L., Polak, M. M., Lazzari, A. A., Moy, M. L., & Wan, E. S. (2022) · Scientific Reports · doi:10.1038/s41598-022-05887-4 · Cited by 27
Statistical Analysis of the Consistency of HRV Analysis Using BCG or Pulse Wave Signals
Cui, H., Wang, Z., Yu, B., Jiang, F., Geng, N., Li, Y., Xu, L., Zheng, D., Zhang, B., Lu, P., et al. (2022) · Sensors · doi:10.3390/s22062423 · Cited by 25
Chaabouni, S., Methnani, R., Al-Hadabi, B., Busafi, M. A., Al-Kitani, M., Jadidi, K. A., Samozino, P., Moalla, W., & Gmada, N. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph19073792 · Cited by 24
Angelomenos, V., Mohaddes, M., Itayem, R., & Shareghi, B. (2022) · Acta Orthopaedica · doi:10.2340/17453674.2022.2528 · Cited by 25
Validation of Abbreviated Form of the Multidimensional Prognostic Index (MPI): The BRIEF-MPI Project
Cella, A., Veronese, N., Custodero, C., Castagna, A., Cammalleri, L., Capitano, W. M., Solimando, L., Carruba, L., Sabbà, C., Ruotolo, G., et al. (2022) · Clinical Interventions in Aging · doi:10.2147/cia.s355801 · Cited by 24
Lin, C., Li, C., Liu, C.-S., Lin, C.-H., Yang, S.-Y., & Li, T. (2022) · Scientific Reports · doi:10.1038/s41598-022-15346-9 · Cited by 26
In-situ monitoring of reinforcement compaction response via MXene-coated glass fabric sensors
Ali, M. A., Irfan, M. S., Khan, T., Ubaid, F., Liao, K., & Umer, R. (2022) · Composites Science and Technology · doi:10.1016/j.compscitech.2022.109623 · Cited by 25
Deprato, A., Ferrara, G., Bhutani, M., Melenka, L., Murgia, N., Usmani, O. S., Lacy, P., & Moitra, S. (2022) · European Respiratory Review · doi:10.1183/16000617.0021-2022 · Cited by 25
Graben, P. R., Schall, M. C., Gallagher, S., Sesek, R. F., & Acosta-Sojo, Y. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph191710595 · Cited by 25
Alkalih, H. Y., Pesola, A. J., & Arumugam, A. (2022) · Heliyon · doi:10.1016/j.heliyon.2022.e11103 · Cited by 27
Marzola, E., Martini, M., Longo, P., Toppino, F., Bevione, F., Delsedime, N., Abbate-Daga, G., & Preti, A. (2022) · Eating and Weight Disorders · doi:10.1007/s40519-022-01503-6 · Cited by 23
Digital versus radiographic accuracy evaluation of guided implant surgery: an in vitro study
Yi, C., Li, S., Wen, A., Wang, Y., Zhao, Y., & Zhang, Y. (2022) · BMC Oral Health · doi:10.1186/s12903-022-02585-5 · Cited by 29
Effect of Poisson's ratio on the indentation of open cell foam
Duncan, O., Foster, L., Allen, T., & Alderson, A. (2023) · European Journal of Mechanics - A/Solids · doi:10.1016/j.euromechsol.2023.104922 · Cited by 24
Comparison of sleep parameters from wrist-worn ActiGraph and Actiwatch devices
Liu, F., Schrack, J. A., Wanigatunga, S., Rabinowitz, J. A., He, L., Wanigatunga, A. A., Zipunnikov, V., Simonsick, E. M., Ferrucci, L., & Spira, A. P. (2023) · SLEEP · doi:10.1093/sleep/zsad155 · Cited by 26
Echocardiographic estimation of pulmonary pressure in patients with severe tricuspid regurgitation
Lemarchand, L., Auffret, V., Breton, H., Bédossa, M., Boulmier, D., Galli, E., Donal, E., & Leurent, G. (2023) · Heart · doi:10.1136/heartjnl-2023-322893 · Cited by 26
Finn, M., Vingopoulos, F., Zhao, Y., Zhou, P., Bannerman, A., Romano, F., Ding, X., Hassan, Z., Patel, N. A., Wu, D. M., et al. (2023) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-023-06291-y · Cited by 28
Intra-urban variability of long-term exposure to PM2.5 and NO2 in five cities in Colombia
Rodríguez-Villamizar, L. A., Rojas, Y., Grisales, S., Mangones, S. C., Cáceres, J., Castañeda, D. M. A., Herrera, V., Marín, D., Piñeros, J. G., Belalcázar, L. C., et al. (2023) · Environmental Science and Pollution Research · doi:10.1007/s11356-023-31306-w · Cited by 24
Metabolomic Association and Risk Prediction With Heart Failure in Older Adults
Liu, G., Nguyen, N. Q., Wong, K. E., Agarwal, S. K., Boerwinkle, E., Chang, P. P., Claggett, B. L., Loehr, L. R., Ma, J., Matsushita, K., et al. (2024) · Circulation Heart Failure · doi:10.1161/circheartfailure.123.010896 · Cited by 30
Radley, D., Cooke, C. B., Fuller, N. J., Oldroyd, B., Truscott, J. G., Coward, W. A., Wright, A., & Gately, P. (2009) · PubMed · Cited by 25
Lynch, B. M., Youlden, D. R., Fritschi, L., Newman, B. M., Pakenham, K. I., Leggett, B., Owen, N. G., & Aitken, J. F. (2008) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2007.05.018 · Cited by 25
Tan, M., Bornais, C., & Rodger, M. A. (2012) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2012.04827.x · Cited by 26
Stojanovska, J., Prasitdumrong, H., Patel, S. V., Sundaram, B., Gross, B. H., Yilmaz, Z. N., & Kazerooni, E. A. (2014) · Journal of Medical Imaging and Radiation Oncology · doi:10.1111/1754-9485.12186 · Cited by 26
Use of scores to calculate the nursing workload in a pediatric intensive care unit
Campagner, A. O. M., Garcia, P. C. R., & Piva, J. P. (2014) · Revista Brasileira de Terapia Intensiva · doi:10.5935/0103-507x.20140006 · Cited by 24
Latifi, K., Forster, K. M., Hoffe, S. E., Dilling, T. J., van Elmpt, W., Dekker, A. L. A. J., & Zhang, G. G. (2013) · Journal of Applied Clinical Medical Physics · doi:10.1120/jacmp.v14i4.4247 · Cited by 24
Kim, J.-H., Kim, M.-H., Kim, G.-S., Park, J.-S., & Kim, E.-K. (2015) · Nutrition Research and Practice · doi:10.4162/nrp.2015.9.4.370 · Cited by 24
Abraham, C. L., Bangerter, N. K., McGavin, L. S., Peters, C. L., Drew, A. J., Hanrahan, C. J., & Anderson, A. E. (2015) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24902 · Cited by 24
An Intraoperative Brain Shift Monitor Using Shear Mode Transcranial Ultrasound
White, P. J., Whalen, S., Tang, S. C., Clement, G. T., Jolesz, F. A., & Golby, A. J. (2009) · Journal of Ultrasound in Medicine · doi:10.7863/jum.2009.28.2.191 · Cited by 24
Caire‐Juvera, G., de la Barca, A. M. C., Bolaños, A., Valencia, M. E., Coward, A. W., Salazar, G., & Casanueva, E. (2002) · Food and Nutrition Bulletin · doi:10.1177/15648265020233s107 · Cited by 24
Murthy, V., Rishi, A., Gupta, S., Kannan, S., Mahantshetty, U. M., Tongaonkar, H. B., Bakshi, G., Prabhash, K., Bhanushali, P. B., Shinde, B., et al. (2015) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2015.10.013 · Cited by 24
Reliability of the Dutch translation of the Kujala Patellofemoral Score Questionnaire
Ummels, P. E. J., Lenssen, A. F., Barendrecht, M., & Beurskens, A. J. H. M. (2015) · Physiotherapy Research International · doi:10.1002/pri.1649 · Cited by 24
Polley, N., Saha, S., Singh, S., Adhikari, A., Das, S., Choudhury, B. R., & Pal, S. K. (2015) · Journal of Biomedical Optics · doi:10.1117/1.jbo.20.6.067001 · Cited by 25
Kwon, J. Y., Park, I. Y., Wie, J. H., Choe, S., Kim, C. J., & Shin, J. C. (2014) · Prenatal Diagnosis · doi:10.1002/pd.4394 · Cited by 24
Mayer, J., Boldt, J., Beschmann, R., Stephan, A., & Suttner, S. (2009) · British Journal of Anaesthesia · doi:10.1093/bja/aep133 · Cited by 24
Retracted
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.