STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 19,701–19,800 of 47,868
In vitro characterization of PrismaLung+: a novel ECCO2R device
Hospach, I., GOLDSTEIN, J. P., Harenski, K., Laffey, J. G., Pouchoulin, D., Raible, M., Votteler, S., & Storr, M. (2020) · Intensive Care Medicine Experimental · doi:10.1186/s40635-020-00301-7 · Cited by 23
Noise exposures in different community settings measured by traditional dosimeter and smartphone app
Jacobs, N. F. B., Roberts, B., Reamer, H., Mathis, C., Gaffney, S. H., & Neitzel, R. L. (2020) · Applied Acoustics · doi:10.1016/j.apacoust.2020.107408 · Cited by 23
The Validity and Reliability of the Mi Band Wearable Device for Measuring Steps and Heart Rate
Paradiso, C., Colino, F., & Liu, S. (2020) · International journal of exercise science · doi:10.70252/njhq9420 · Cited by 33
Monfort-Pañego, M., & Miñana-Signes, V. (2020) · Measurement in Physical Education and Exercise Science · doi:10.1080/1091367x.2020.1784899 · Cited by 26
The effect of a split portion of flaxseed on 24-h blood glucose response
Almehmadi, A. M., Lightowler, H. J., Chohan, M., & Clegg, M. (2020) · European Journal of Nutrition · doi:10.1007/s00394-020-02333-x · Cited by 30
Jain, A., & Chowdhury, N. (2020) · Asian Journal of Transfusion Science · doi:10.4103/ajts.ajts_93_17 · Cited by 23
Stoumpos, S., Tan, A. B., Barrientos, P. H., Stevenson, K. S., Thomson, P. C., Kasthuri, R. S., Radjenovic, A., Kingsmore, D. B., Roditi, G., & Mark, P. B. (2020) · Radiology · doi:10.1148/radiol.2020200069 · Cited by 23
Hindle, B. R., Keogh, J., & Lorimer, A. V. (2020) · Sensors · doi:10.3390/s20164586 · Cited by 25
Ryan, J. M., McKay, E., Anokye, N., Noorkõiv, M., Theis, N., & Lavelle, G. (2020) · BMJ Open · doi:10.1136/bmjopen-2020-037089 · Cited by 26
Bai, M., Susic, D. F., O’Sullivan, A., & Henry, A. (2020) · Journal of Obesity · doi:10.1155/2020/3128767 · Cited by 26
Venetsanou, F., Emmanouılıdou, K., Soutos, K., Sotiriou, S. A., Bastida, L., Moya, A., & Kambas, A. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17228503 · Cited by 26
Jiang, L., Lin, R., Gallagher, S., Zayac, A., Butchbach, M. E. R., & Hung, P. J. (2020) · Scientific Reports · doi:10.1038/s41598-020-76893-7 · Cited by 27
Li, K. J., Brouwer-Brolsma, E. M., Burton, K. J., Vergères, G., & Feskens, E. J. M. (2020) · BMC Nutrition · doi:10.1186/s40795-020-00394-z · Cited by 26
Proposition of a corrected measure of the Lawton instrumental activities of daily living score
the MEMORA group, Dufournet, M., Moutet, C., Achi, S., Delphin‐Combe, F., Krolak‐Salmon, P., & Dauphinot, V. (2021) · BMC Geriatrics · doi:10.1186/s12877-020-01995-w · Cited by 25
Kersten, R. F. M. R., Fikkers, J., Wolterbeek, N., Öner, F. C., & van Gaalen, S. M. (2021) · Journal of Back and Musculoskeletal Rehabilitation · doi:10.3233/bmr-200206 · Cited by 23
Rosenkranz, S. C., Kaulen, B., Zimmermann, H. G., Bittner, A. K., Dörr, M., & Stellmann, J. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.591302 · Cited by 25
Accuracy of noncontact surface imaging for tidal volume and respiratory rate measurements in the ICU
L’Her, E., Nazir, S., Pateau, V., & Visvikis, D. (2021) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-021-00708-x · Cited by 23
Predictive Performance of Bayesian Vancomycin Monitoring in the Critically Ill*
Narayan, S. W., Thoma, Y., Drennan, P. G., Kim, H. Y., Alffenaar, J. C., van Hal, S. J., & Patanwala, A. E. (2021) · Critical Care Medicine · doi:10.1097/ccm.0000000000005062 · Cited by 24
Raynor, E. J., Derner, J., Soder, K. J., & Augustine, D. J. (2021) · Applied Animal Behaviour Science · doi:10.1016/j.applanim.2021.105402 · Cited by 23
Cho, B. W., Lee, T., Kim, S. J., Choi, C., Jung, M., Lee, K. Y., & Kim, S. (2021) · Scientific Reports · doi:10.1038/s41598-021-01646-z · Cited by 23
Perrone, M. R., Lorusso, A., & Romano, S. (2021) · Atmospheric Research · doi:10.1016/j.atmosres.2021.105889 · Cited by 24
Point-of-Care Hemoglobin A1c Testing: An Evidence-Based Analysis.
(2014) · PubMed · Cited by 29
Martens, A. L., Bolte, J. F. B., Beekhuizen, J., Kromhout, H., Smid, T., & Vermeulen, R. C. H. (2015) · Environmental Research · doi:10.1016/j.envres.2015.06.029 · Cited by 27
Obesity and Myelomeningocele: Anthropometric Measures
SHURTLEFF, D. B., Walker, W. O., Duguay, S., Peterson, D. E., & Cardenas, D. D. (2010) · Journal of Spinal Cord Medicine · doi:10.1080/10790268.2010.11689720 · Cited by 23
Evaluation of the accuracy of the Omron HEM-907 blood pressure device.
Gurpreet, K., Tee, G., & Chinna, K. (2008) · PubMed · Cited by 23
Repeatability of exhaled nitric oxide measurements in patients with COPD
Rouhos, A., Kainu, A., Piirilä, P. L., Sarna, S. J., Lindqvist, A. E., Karjalainen, J., & Sovijärvi, A. R. A. (2010) · Clinical Physiology and Functional Imaging · doi:10.1111/j.1475-097x.2010.00975.x · Cited by 27
Fukuda, S., Kishino, G., Hoshi, S., Beheregaray, S., Ueno, Y., Fukuda, M., Kasaragod, D. K., Yasuno, Y., & Oshika, T. (2015) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.14-16327 · Cited by 23
Amm, M., & Hedderich, J. (2004) · Der Ophthalmologe · doi:10.1007/s00347-004-1082-5 · Cited by 23
Carbone, I., Childs, H., Aljizeeri, A. H., Merchant, N., & Friedrich, M. G. (2015) · BioMed Research International · doi:10.1155/2015/232649 · Cited by 23
Staier, K., Wiesenack, C., Günkel, L., & Keyl, C. (2008) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03017593 · Cited by 23
Pereira, F. M., Ribeiro, M. Â. G. D. O., Ribeiro, A. F., Toro, A. A. D. C., Hessel, G., & Ribeiro, J. D. (2011) · Jornal Brasileiro de Pneumologia · doi:10.1590/s1806-37132011000600006 · Cited by 33
Use of filter paper for sample collection and transport in steroid pharmacology
Howe, C. J., & Handelsman, D. J. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.8.1408 · Cited by 23
Collecting women's reproductive histories
Beall, C. M., & Leslie, P. W. (2014) · American Journal of Human Biology · doi:10.1002/ajhb.22543 · Cited by 23
Mechlenburg, I., Nyengaard, J. R., Gelineck, J., Søballé, K., & Troelsen, A. (2010) · Clinical Orthopaedics and Related Research · doi:10.1007/s11999-010-1310-z · Cited by 23
Savini, G., Goto, E., Carbonelli, M., Barboni, P., & Huang, D. (2009) · Cornea · doi:10.1097/ico.0b013e31818526d0 · Cited by 23
SANDERCOCK, G. R. H., Shelton, C., Bromley, P. D., & Brodie, D. A. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/5/003 · Cited by 23
Location of body fat and body size impacts DXA soft tissue measures: a simulation study
Valentine, R. J., Misic, M. M., Kessinger, R. B., Mojtahedi, M. C., & Evans, E. M. (2007) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1602770 · Cited by 28
Bammann, K., Huybrechts, I., Vicente‐Rodríguez, G., Easton, C., Vriendt, T. D., Mårild, S., Mesana, M. I., Peeters, M., Reilly, J. J., Sioen, I., et al. (2013) · International Journal of Obesity · doi:10.1038/ijo.2013.13 · Cited by 23
Comparison of Tracheal Diameter Measured by Chest X-Ray and by Computed Tomography
Sakuraba, S., Serita, R., Kuribayashi, J., Kosugi, S., Arisaka, H., Yoshida, K.-I., & Takeda, J. (2010) · Anesthesiology Research and Practice · doi:10.1155/2010/269171 · Cited by 23
Santodomingo‐Rubido, J., Villa-Collar, C. C., Gilmartin, B., & Gutiérrez-Ortega, R. (2014) · Eye & Contact Lens Science & Clinical Practice · doi:10.1097/icl.0000000000000014 · Cited by 23
Fu, J. H., Wang, X., Li, S., Wu, G., & Wang, N. (2010) · Canadian Journal of Ophthalmology · doi:10.3129/i10-068 · Cited by 23
Microspheres Accurately Predict Regional Bone Blood Flow
Anetzberger, H., Thein, E., Becker, M., Zwißler, B., & Meßmer, K. (2004) · Clinical Orthopaedics and Related Research · doi:10.1097/01.blo.0000128281.67589.b4 · Cited by 23
Uri, N., GIPS, S., Front, A., Meyer, S. W., & Hardoff, R. (1991) · Archives of Otolaryngology - Head and Neck Surgery · doi:10.1001/archotol.1991.01870180059012 · Cited by 23
Rodríguez-Granillo, G. A., Bruining, N., Fadden, E. P. M., Ligthart, J. M. R., Aoki, J., Regar, E. S., de Feyter, P. J., & Serruys, P. W. J. C. (2005) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.20447 · Cited by 23
Noninvasive blood pressure measurement in the upper and lower limbs of anaesthetized children
Short, J. A. (2000) · Pediatric Anesthesia · doi:10.1046/j.1460-9592.2000.00558.x · Cited by 23
Scuffi, C., Lucarelli, F., & Valgimigli, F. (2012) · Journal of Diabetes Science and Technology · doi:10.1177/193229681200600618 · Cited by 27
An Enzymatic Method to Determine γ-Hydroxybutyric Acid in Serum and Urine
Hasan, L., Jermann, T. M., Weber, J. M., Abrahamsson, L., Sciotti, M., Böttcher, M., Jochle, W., Gygax, D., & Scholer, A. (2011) · Therapeutic Drug Monitoring · doi:10.1097/ftd.0b013e318239a41a · Cited by 23
Saint‐Marcoux, F., Debord, J., Parant, F., Labalette, M., Kamar, N., Rostaing, L. P. E., Rousseau, A., & Marquet, P. (2011) · Therapeutic Drug Monitoring · doi:10.1097/ftd.0b013e31820d6ef7 · Cited by 23
Prediction of Body Fat by Anthropometry in Older Chinese People
Kwok, T. C. Y., Woo, J., & Lau, E. (2001) · Obesity Research · doi:10.1038/oby.2001.12 · Cited by 23
de Meer, K., Gulmans, V., Westerterp, K. R., Houwen, R. H. J., & Berger, R. (1999) · European Journal of Pediatrics · doi:10.1007/s004310051209 · Cited by 23
Meijer-Hoogeveen, M., Stoutenbeek, P., & Visser, G. H. A. (2008) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.4093 · Cited by 23
The effect of sodium valproate on proton MRS visible neurochemical concentrations
Simister, R. J., McLean, M. A., Barker, G. J., & Duncan, J. S. (2007) · Epilepsy Research · doi:10.1016/j.eplepsyres.2007.03.001 · Cited by 23
Schwitter, J., Oelhafen, M., Wyss, B. M., Kozerke, S., Amann-Vesti, B. R., Lüscher, T. F., & Boesiger, P. (2006) · Journal of Cardiovascular Magnetic Resonance · doi:10.1080/10976640600737573 · Cited by 23
ASSESSMENT OF CARDIAC CHAMBER SIZE USING ANATOMIC M‐MODE
Oyama, M. A., & Sisson, D. D. (2005) · Veterinary Radiology & Ultrasound · doi:10.1111/j.1740-8261.2005.00062.x · Cited by 23
Lam, A. K. C., Lam, C. H., & Chan, R. (2005) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2005.00296.x · Cited by 23
Masharawi, Y., Kjær, P., Bendix, T., Manniche, C., Wedderkopp, N., Sørensen, J. S., Peled, N., & Jensen, T. S. (2008) · Spine · doi:10.1097/brs.0b013e31817f19f7 · Cited by 23
Kukucka, M., Nasseri, B., Tscherkaschin, A., Mladenow, A., Kuppe, H., & Habazettl, H. (2009) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2008.12.002 · Cited by 23
Hong, Y., Sung, J., Kim, S., Park, K. S., Lee, K., Chang, K., & Song, I. C. (2008) · Journal of Neuroimaging · doi:10.1111/j.1552-6569.2007.00153.x · Cited by 23
Ho, K. M., Harding, R., & Chamberlain, J. (2007) · Anaesthesia and Intensive Care · doi:10.1177/0310057x0703500506 · Cited by 23
Dennis, A. T., Arhanghelschi, I., Simmons, S., & Royse, C. F. (2010) · International Journal of Obstetric Anesthesia · doi:10.1016/j.ijoa.2009.06.007 · Cited by 26
Use of disposable prism tonometry in routine clinical practice
Salvi, S. M., Sivakumar, S., & Sidiki, S. S. (2004) · Eye · doi:10.1038/sj.eye.6701633 · Cited by 23
Point-of-care creatinine testing in children at risk for sudden deterioration of renal function
Schenk, P. W., Cransberg, K., Wolff, E. D., & de Rijke, Y. B. (2007) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2007.314 · Cited by 23
Leotta, D. F., Primozich, J. F., Beach, K. W., Bergelin, R. O., & Strandness, D. E. (2001) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(00)00296-9 · Cited by 23
Fields, D. A., Kearney, J. T., & Copeland, K. C. (2006) · Obesity · doi:10.1038/oby.2006.202 · Cited by 23
BORRELL, A., Pérez, M. I. C., Figueras, F., Meler, E., Goncé, A., & Gratacós, E. (2007) · Prenatal Diagnosis · doi:10.1002/pd.1706 · Cited by 23
Shimizu, Y., Yamada, S., Suzuki, M., Miyoshi, H., Kono, Y., Izawa, H., Kato, R., & Murohara, T. (2009) · Gerontology · doi:10.1159/000248628 · Cited by 26
Cardiovascular responses to short‐term head‐down positioning in healthy young and older adults
Naylor, J., Chow, C. M., McLean, A. S., Heard, R. C., & Avolio, A. P. (2005) · Physiotherapy Research International · doi:10.1002/pri.22 · Cited by 27
Quantification of pericardial effusions by three-dimensional echocardiography
de Prada, J. A. V., Jiang, L., Handschumacher, M. D., Xie, S. W., Rivera, J. M., Schwammenthal, E., Guerrero, J. L., Weyman, A. E., Levine, R. A., & Picard, M. H. (1994) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(94)90571-1 · Cited by 23
Kimokoti, R. W., Newby, P. K., Gona, P. N., Zhu, L., Campbell, W. R., D’Agostino, R. B., & Millen, B. E. (2011) · European Journal of Clinical Nutrition · doi:10.1038/ejcn.2011.167 · Cited by 24
DEVELOPMENT AND VALIDATION OF ECHOCARDIOGRAPHY METHODS FOR ESTIMATING LEFT VENTRICULAR MASS IN RATS
Jones, E. F., Harrap, S. B., Calafiore, P. A., & Tonkin, A. M. (1992) · Clinical and Experimental Pharmacology and Physiology · doi:10.1111/j.1440-1681.1992.tb00472.x · Cited by 23
HERSE, P. R., Hans, A., Hall, J., Langejans, J., & Markoulli, M. P. (2005) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2005.00302.x · Cited by 23
Endothelial Cell Density in Donor Corneas
Hirneiß, C., Schumann, R. G., Grüterich, M., Welge-Luessen, U. C., Kampik, A., & Neubauer, A. S. (2006) · Cornea · doi:10.1097/ico.0b013e31802be629 · Cited by 23
Avaliação da reprodutibilidade e validade de questionário de atividade física para gestantes
Takito, M. Y., Neri, L. D. C. L., & Benício, M. H. D. (2008) · Revista Brasileira de Medicina do Esporte · doi:10.1590/s1517-86922008000200010 · Cited by 35
Baltalı, E., Zhao, K. D., Koff, M. F., Durmuş, E., An, K., & Keller, E. E. (2008) · Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.joms.2008.01.021 · Cited by 26
Effect of high bicarbonate hemodialysis on ionized calcium and risk of metastatic calcification
Kirschbaum, B. B. (2004) · Clinica Chimica Acta · doi:10.1016/j.cccn.2004.02.003 · Cited by 23
Hamdan, A., Thouet, T., Kelle, S., Wellnhofer, E., Paetsch, I., Gebker, R., Schnackenburg, B., Fahmy, A. S., Osman, N. F., Bornstedt, A., et al. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21684 · Cited by 23
Sawadogo, S., Shiningavamwe, A. N., Chang, J. C.-W., Maher, A. D., Zhang, G., Yang, C., Gaeb, E., Kaura, H., Ellenberger, D. L., & Lowrance, D. W. (2014) · Journal of Clinical Microbiology · doi:10.1128/jcm.02063-14 · Cited by 23
Pfützner, A., Kunt, T., Langenfeld, M. R. W., Löbig, M., Knesovic, M., & Forst, T. M. (2003) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2003.189 · Cited by 23
Hematologic Study of Red Pacu (Colossoma brachypomum)
Tocidlowski, M. E., Lewbart, G. A., & Stoskopf, M. K. (1997) · Veterinary Clinical Pathology · doi:10.1111/j.1939-165x.1997.tb00722.x · Cited by 23
Sayanagi, K., Sharma, S. K., & Kaiser, P. K. (2009) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2009.04.008 · Cited by 23
Optimal recall period in assessing the adherence to antihypertensive therapy: a pilot study
Doró, P., Benkő, R., Czakó, A., Matúz, M., Thurzó, F., & Soós, G. (2011) · International Journal of Clinical Pharmacy · doi:10.1007/s11096-011-9529-7 · Cited by 25
Lachmann, S., Kimmerle-Mueller, E., Axmann, D., Gómez-Román, G., Weber, H., & Haas, R. (2007) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2007.01399.x · Cited by 28
Dini, F. L., Traversi, E., Franchini, M., Micheli, G., Cobelli, F., & Pozzoli, M. (2003) · Journal of the American Society of Echocardiography · doi:10.1067/mje.2003.8 · Cited by 23
Vré, E. A. V., van Beusekom, H. M., Vrints, C. J., Bosmans, J. M., Bult, H., & van der Giessen, W. J. (2007) · Cardiovascular Pathology · doi:10.1016/j.carpath.2006.08.001 · Cited by 23
Chakravarthy, M., Subramanyam, R., & Jawali, V. (2009) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-009-9179-7 · Cited by 23
Fourier analysis of digital retinal images in estimation of cataract severity
Abdul-Rahman, A. M., Molteno, T., & Molteno, A. C. (2008) · Clinical and Experimental Ophthalmology · doi:10.1111/j.1442-9071.2008.01819.x · Cited by 23
Automated segmentation of retinal pigment epithelium cells in fluorescence adaptive optics images
Rangel-Fonseca, P., Gómez-Vieyra, A., Malacara-Hernández, D., Wilson, M., Williams, D. R., & Rossi, E. A. (2013) · Journal of the Optical Society of America A · doi:10.1364/josaa.30.002595 · Cited by 25
A simplified method for deriving shunt and reduced VA/Q in infants
Rowe, L., Jones, J. G., Quine, D., Bhushan, S., & Stenson, B. J. (2009) · Archives of Disease in Childhood Fetal & Neonatal · doi:10.1136/adc.2009.160010 · Cited by 23
Comparative study of two automated high-sensitivity C-reactive protein methods in a large population
Lolekha, P. H., Chittamma, A., Roberts, W. L., Sritara, P., Cheepudomwit, S., & Suriyawongpaisal, P. (2004) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2004.09.001 · Cited by 25
Andersen, C., Taagehøj, J. F., Mühler, A., & Rehling, M. (1996) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(95)02082-5 · Cited by 23
Machado‐Rodrigues, A. M., Coelho-e-Silva, M. J., Mota, J. A. P. S., Cyrino, E. S., Cumming, S. P., Riddoch, C., Beunen, G. P., & Malina, R. M. (2011) · Journal of Sports Sciences · doi:10.1080/02640414.2011.593185 · Cited by 30
Quantitative contrast‐enhanced perfusion measurements of the human lung using the prebolus approach
Oechsner, M., Mühlhäusler, M., Ritter, C. O., Weininger, M., Beissert, M., Jakob, P. M., Beer, M., Hahn, D., & Köstler, H. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21793 · Cited by 23
Estimation of remaining dentine thickness below deep lesions of caries
Lancaster, P. E., Craddock, H. L., & Carmichael, F. A. (2011) · BDJ · doi:10.1038/sj.bdj.2011.965 · Cited by 23
Elliott, W. J., Young, P. E., DeVivo, L., Feldstein, J. D., & Black, H. R. (2007) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e3280858dcf · Cited by 25
Tocco, F., Marongiu, E., Pinna, M., Roberto, S., Pusceddu, M. M., Angius, L., Migliaccio, G. M., Milia, R., Concu, A., & Crisafulli, A. (2012) · Acta Physiologica · doi:10.1111/apha.12000 · Cited by 23
King, R., & Campbell, A. (2000) · Anaesthesia · doi:10.1046/j.1365-2044.2000.01166.x · Cited by 23
KIMURA, Y., Takamatsu, K., Fujii, A., Suzuki, M., Chikada, N., Tanada, R., Kume, Y., & Satō, H. (2007) · Journal of obstetrics and gynaecology research · doi:10.1111/j.1447-0756.2007.00531.x · Cited by 27
Non-Circular Shape of Right Ventricular Outflow Tract
Izumo, M., Shiota, M., Saitoh, T., Kuwahara, E., Fukuoka, Y., Gurudevan, S. V., Tolstrup, K., Siegel, R. J., & Shiota, T. (2012) · Circulation Cardiovascular Imaging · doi:10.1161/circimaging.112.974287 · Cited by 23
Socket wear in bilateral simultaneous total hip arthroplasty
Joshi, A., Ilchmann, T., & Markovic, L. (2001) · The Journal of Arthroplasty · doi:10.1054/arth.2001.19160 · Cited by 23
Monsky, W. L., Jin, B., Molloy, C., Canter, R. J., Li, C. S., Lin, T. C., Borys, D., Mack, W., Kim, I., Buonocore, M. H., et al. (2012) · PubMed · Cited by 36
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.