STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 20,101–20,200 of 47,868
Image processing techniques to quantify microprojections on outer corneal epithelial cells
Julio, G., Merindano, M. D., Canals, M., & Ralló, M. (2008) · Journal of Anatomy · doi:10.1111/j.1469-7580.2008.00898.x · Cited by 22
Robotham, D., Schoeller, D. A., Mercado, A. B., Mirch, M. C., Theim, K. R., Reynolds, J. C., & Yanovski, J. A. (2006) · Journal of Pediatric Gastroenterology and Nutrition · doi:10.1097/01.mpg.0000189373.31697.15 · Cited by 24
Gabbe, B. J., Simpson, P. M., Sutherland, A. M., Palmer, C. S., Butt, W. W., Bevan, C., & Cameron, P. A. (2010) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/ta.0b013e3181f8fd5f · Cited by 22
Quist, H. G., Christensen, U., Carneiro, I. G., Hansen, J. V., & Bjørner, J. B. (2014) · Preventive Medicine · doi:10.1016/j.ypmed.2014.07.032 · Cited by 24
MacIntyre, N. J., Lorbergs, A. L., & Adachi, J. D. (2013) · Osteoporosis International · doi:10.1007/s00198-013-2484-5 · Cited by 22
Radermecker, R. P., Fayolle, C., Brun, J. ‐., Bringer, J., & Renard, É. (2013) · Diabetes & Metabolism · doi:10.1016/j.diabet.2012.12.004 · Cited by 23
Cañas, T., Fontanilla, T., Miralles, M., Maciá, A., Malalana, A., & Román, E. (2015) · Pediatric Radiology · doi:10.1007/s00247-015-3306-z · Cited by 22
Forensic anthropology and human identification
Lynnerup, N. (2013) · Scandinavian Journal of Forensic Science · doi:10.2478/sjfs-2013-0005 · Cited by 29
Dièye, T. N., Diaw, P. A., Daneau, G., Wade, D., Niang, M. S., Camara, M., Diallo, A. A., Kane, C. T., Diop‐Ndiaye, H., Mbengué, B., et al. (2011) · Journal of Immunological Methods · doi:10.1016/j.jim.2011.07.012 · Cited by 22
The perceptually regulated exercise test is sensitive to increases in maximal oxygen uptake
Evans, H., Parfitt, G., & Eston, R. G. (2012) · European Journal of Applied Physiology · doi:10.1007/s00421-012-2541-3 · Cited by 29
Reliability of a Sleep Quality Questionnaire for Use in Epidemiologic Studies
Girschik, J., Heyworth, J. S., & Fritschi, L. (2012) · Journal of Epidemiology · doi:10.2188/jea.je20110107 · Cited by 28
Hill, R. J., & Davies, P. S. W. (2013) · Journal of Pediatric Gastroenterology and Nutrition · doi:10.1097/mpg.0b013e31827e1f25 · Cited by 24
del Paso, G. A. R., González, M. I., & Hernández, J. A. (2010) · Psychophysiology · doi:10.1111/j.1469-8986.2010.01018.x · Cited by 24
Pinna, M., Milia, R., Roberto, S., Marongiu, E., Olla, S., Loi, A., Ortu, M., Migliaccio, G. M., Tocco, F., Concu, A., et al. (2012) · The Journal of Physiological Sciences · doi:10.1007/s12576-012-0226-7 · Cited by 29
Patel, R. P., & Pandit, R. T. (2012) · Journal of Ophthalmology · doi:10.1155/2012/430249 · Cited by 22
Smith, P. M., Doherty, M., & Price, M. (2006) · Journal of Sports Sciences · doi:10.1080/02640410600831955 · Cited by 22
Slagt, C., Helmi, M., Malagon, I. L., & Groeneveld, A. B. J. (2014) · European Journal of Anaesthesiology · doi:10.1097/eja.0000000000000173 · Cited by 22
Reekers, M., Simon, M. J. G., Boer, F., Mooren, R. A. G., van Kleef, J. W., Dahan, A., & Vuyk, J. (2010) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181c92b09 · Cited by 22
Acer, N., Şahin, B., Uçar, T., & Usanmaz, M. (2009) · Journal of Craniofacial Surgery · doi:10.1097/scs.0b013e3181843518 · Cited by 22
Influence of Screw Design, Sex, and Approach in Scaphoid Fracture Fixation
Meermans, G., & Verstreken, F. (2011) · Clinical Orthopaedics and Related Research · doi:10.1007/s11999-011-2218-y · Cited by 22
Assessment of food chemical intolerance in adult asthmatic subjects.
Hodge, L., Yan, K., & Loblay, R. L. (1996) · Thorax · doi:10.1136/thx.51.8.805 · Cited by 22
Item‐Glatthorn, J. F., Casartelli, N. C., Petrich-Munzinger, J., Munzinger, U., & Maffiuletti, N. A. (2012) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2012.06.018 · Cited by 22
Qayyum, A. A., Hasbak, P., Larsson, H. B. W., Christensen, T. E., Ghotbi, A. A., Mathiasen, A. B., Vejlstrup, N. G., Kjær, A., & Kastrup, J. (2014) · European Journal of Radiology · doi:10.1016/j.ejrad.2014.04.004 · Cited by 22
Egger, M. J., Hamad, N. M., Hitchcock, R. W., Coleman, T. J., Shaw, J. M., Hsu, Y., & Nygaard, I. (2015) · Urogynecology · doi:10.1097/spv.0000000000000167 · Cited by 22
Sung, M.-S., Kang, B. W., Kim, H.-G., Heo, H., & Park, S. (2012) · Journal of Glaucoma · doi:10.1097/ijg.0b013e318279c932 · Cited by 22
Validation and application of a canine-specific automated high-sensitivity C-reactive protein assay
Hillström, A., Hagman, R., Söder, J., Häggström, J. U., Ljungvall, I., & Kjelgaard-Hansen, M. J. (2015) · Journal of Veterinary Diagnostic Investigation · doi:10.1177/1040638715575751 · Cited by 28
Chen, S. S. M., Keegan, J., Dowsey, A. W., Ismail, T. F., Wage, R., Li, W., Yang, G., Firmin, D. N., & Kilner, P. J. (2011) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-13-80 · Cited by 22
Repeatability of OCT Lens Thickness Measures With Age and Accommodation
Doyle, L. A., Little, J., & Saunders, K. J. (2013) · Optometry and Vision Science · doi:10.1097/opx.0000000000000080 · Cited by 22
Objectivity and Stability of the Preschool Imitation and Praxis Scale
Vanvuchelen, M., Roeyers, H., & Weerdt, W. D. (2011) · American Journal of Occupational Therapy · doi:10.5014/ajot.2010.ajot00000414 · Cited by 25
Crossover and maximal fat-oxidation points in sedentary healthy subjects: Methodological issues
Gmada, N., Marzouki, H., Haboubi, M., Tabka, Z., Shephard, R. J., & Bouhlel, E. (2011) · Diabetes & Metabolism · doi:10.1016/j.diabet.2011.07.004 · Cited by 27
Gonçalves, E. M., Matias, C. N., Santos, D. A., Sardinha, L. B., & Silva, A. M. (2014) · Journal of Sports Sciences · doi:10.1080/02640414.2014.953981 · Cited by 26
In vitro strain measurement in the porcine antrum using ultrasound doppler strain rate imaging
Ahmed, A. B., Gilja, O. H., Gregersen, H. N., Ødegaard, S., & Matre, K. (2006) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2005.12.019 · Cited by 22
Pre-operative mental wellbeing and the outcome of knee replacement
Walton, M. J., & Newman, J. H. (2008) · The Knee · doi:10.1016/j.knee.2008.03.001 · Cited by 22
Isokinetic versus One-Repetition Maximum Strength Assessment in Chronic Heart Failure
Feiereisen, P., Vaillant, M., EISCHEN, D., & Delagardelle, C. (2010) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181e3e2cb · Cited by 24
Lorenzen, S., von Gall, C. C., Stange, A., Haag, G. M., Weitz, J., Haberkorn, U., Lordick, F., Weichert, W., Abel, U. R., Debus, J., et al. (2011) · BMC Cancer · doi:10.1186/1471-2407-11-266 · Cited by 22
Reproducibility and validity of an FFQ to assess usual intake of methyl-group donors
Pauwels, S., Doperé, I., Huybrechts, I., Godderis, L., Koppen, G., & Vansant, G. A. A. M. (2015) · Public Health Nutrition · doi:10.1017/s1368980014003140 · Cited by 24
SlideToolkit: An Assistive Toolset for the Histological Quantification of Whole Slide Images
Nelissen, B. G. L., van Herwaarden, J. A., Moll, F. L., van Diest, P. J., & Pasterkamp, G. (2014) · PLoS ONE · doi:10.1371/journal.pone.0110289 · Cited by 22
Lambot, K., Boavida, P., Damasio, M. B., de Horatio, L. T., Desgranges, M., Malattia, C., Barbuti, D., Bracaglia, C., Müller, L. O., Elie, C., et al. (2013) · Pediatric Radiology · doi:10.1007/s00247-012-2613-x · Cited by 22
Bendtsen, C., Kietzmann, M., Korn, R., Mozley, P. D., Schmidt, G., & Binnig, G. K. (2011) · International Journal of Biomedical Imaging · doi:10.1155/2011/361589 · Cited by 24
Fiebig, E. W., Etzell, J. E., & Ng, V. (2005) · American Journal of Clinical Pathology · doi:10.1309/lkyk-clpm-pfg4-jpua · Cited by 24
Krissak, R., Mistretta, C. A., Henzler, T., Chatzikonstantinou, A., Scharf, J., Schoenberg, S. O., & Fink, C. (2011) · PLoS ONE · doi:10.1371/journal.pone.0017098 · Cited by 22
Pop, M., Ramanan, V., Yang, F., Zhang, L., Newbigging, S., Ghugre, N. R., & Wright, G. A. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2336593 · Cited by 22
Clinical and neuroimaging evidence of interictal cerebellar dysfunction in FHM2
Grimaldi, D., Tonon, C., Cevoli, S., Pierangeli, G., Malucelli, E., Rizzo, G., Soriani, S., Montagna, P., Barbiroli, B., Lodi, R., et al. (2009) · Cephalalgia · doi:10.1111/j.1468-2982.2009.01979.x · Cited by 22
Pavlopoulos, H., & Nihoyannopoulos, P. (2008) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2008.01.017 · Cited by 22
The Assessment of Intraoperative Prosthetic Knee Range of Motion Using Two Methods
Austin, M. S., Ghanem, E. S., Joshi, A., Trappler, R., Parvizi, J., & Hozack, W. J. (2008) · The Journal of Arthroplasty · doi:10.1016/j.arth.2007.12.011 · Cited by 22
Biase, L. D., Perini, A. P., Mohanty, P. K., Goldenberg, A. S., Grifoni, G., Santangeli, P., Santoro, F., Sánchez, J., Horton, R., Gallinghouse, G. J., et al. (2013) · Heart Rhythm · doi:10.1016/j.hrthm.2013.11.016 · Cited by 23
Reliability and validity of findings in ergonomics research
Kanis, H. (2013) · Theoretical Issues in Ergonomics Science · doi:10.1080/1463922x.2013.802058 · Cited by 24
Hassett, L. M., Moseley, A. M., Harmer, A. R., & van der Ploeg, H. P. (2014) · Journal of Head Trauma Rehabilitation · doi:10.1097/htr.0000000000000047 · Cited by 22
Tani, L. Y., Minich, L. L., Pagotto, L. T., & Shaddy, R. E. (2000) · The American Journal of Cardiology · doi:10.1016/s0002-9149(00)00842-0 · Cited by 22
Comparison of energy estimates in chronic kidney disease using doubly‐labelled water
Sridharan, S., Wong, J., Vilar, E., & Farrington, K. (2015) · Journal of Human Nutrition and Dietetics · doi:10.1111/jhn.12326 · Cited by 24
Tortorano, A. M., Viviani, M. A., Barchiesi, F., Arzeni, D., Rigoni, A. L., Cogliati, M., Compagnucci, P., & Scalise, G. (1998) · Journal of Clinical Microbiology · doi:10.1128/jcm.36.6.1578-1583.1998 · Cited by 28
Larsen, M. B., Hansen, R. P., Sokolowski, I., & Vedsted, P. (2013) · Cancer Epidemiology · doi:10.1016/j.canep.2013.10.006 · Cited by 22
Hsu, Y., Pan, R., Shih, Y. I., Lee, M.-S., & Huang, G.-S. (2010) · Acta Radiologica · doi:10.3109/02841850903524421 · Cited by 22
Predicted versus measured resting energy expenditure in patients requiring home parenteral nutrition
Ławiński, M., Singer, P., Gradowski, Ł., Gradowska, A., Bzikowska‐Jura, A., & Majewska, K. (2015) · Nutrition · doi:10.1016/j.nut.2015.05.002 · Cited by 22
Torfs, S., Maes, A., Delesalle, C. J. G., Deprez, P. R., & Croubels, S. (2012) · Journal of Veterinary Diagnostic Investigation · doi:10.1177/1040638712457928 · Cited by 25
Computational area measurement of orbital floor fractures: Reliability, accuracy and rapidity
Schouman, T., Courvoisier, D. S., Imholz, B., Issum, C. V., & Scolozzi, P. (2011) · European Journal of Radiology · doi:10.1016/j.ejrad.2011.06.024 · Cited by 22
Diversity Based on Entropy: A Novel Evaluation Criterion in Multi-objective Optimization Algorithm
Wang, L., & Chen, Y. (2012) · International Journal of Intelligent Systems and Applications · doi:10.5815/ijisa.2012.10.12 · Cited by 22
Vrtovsnik, F., Coester, A. M., Barreto, D. L., de Waart, D. R., van der Wal, A. C., Struijk, D. G., Krediet, R. T., & Zweers, M. M. (2010) · Peritoneal Dialysis International · doi:10.3747/pdi.2008.00272 · Cited by 22
The magnification of digital radiographs in the trauma patient: Implications for templating
King, R., Craig, P. R. S., Boreham, B., Majeed, M. A., & Moran, C. G. (2008) · Injury · doi:10.1016/j.injury.2008.06.027 · Cited by 22
Meesters, R. J. W., Hooff, G. P., Gruters, R. A., van Kampen, J. J. A., & Luider, T. M. (2012) · Bioanalysis · doi:10.4155/bio.11.328 · Cited by 22
Sieslack, A. K., Dziallas, P., Nolte, I. J. A., & Wefstaedt, P. (2013) · American Journal of Veterinary Research · doi:10.2460/ajvr.74.7.990 · Cited by 22
Dental age assessment (DAA): A study of a Caucasian population at the 13 year threshold
Chudasama, P. N., ROBERTS, G. J., & Lucas, V. S. (2011) · Journal of Forensic and Legal Medicine · doi:10.1016/j.jflm.2011.09.008 · Cited by 22
Heart rate variability to assess ventilatory thresholds: reliable in cardiac disease?
Mourot, L., Tordi, N., Bouhaddi, M., Teffaha, D., Monpère, C., & Regnard, J. (2011) · European Journal of Preventive Cardiology · doi:10.1177/1741826711423115 · Cited by 24
Day, A. C., Garway‐Heath, D. F., Broadway, D. C., Jiang, Y., Hayat, S. A., Dalzell, N., Khaw, K., & Foster, P. J. (2012) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2012-302147 · Cited by 22
Caviezel, S., Dratva, J., Schaffner, E., Teynor, A., Baumstark, M. W., Schindler, C., de Groot, E., Burdet, L., Rothe, T., Pons, M., et al. (2013) · Atherosclerosis · doi:10.1016/j.atherosclerosis.2013.10.010 · Cited by 29
Impact of ethnicity upon body composition assessment in Sri Lankan Australian children
Wickramasinghe, P., Cleghorn, G. J., Edmiston, K. A., & Davies, P. (2005) · Journal of Paediatrics and Child Health · doi:10.1111/j.1440-1754.2005.00558.x · Cited by 22
CT Signs of Hepatofugal Portal Venous Flow in Patients with Cirrhosis
Bryce, T. J., Yeh, B. M., Qayyum, A., Pacharn, P., Bass, N. M., Lü, Y., & Coakley, F. V. (2003) · American Journal of Roentgenology · doi:10.2214/ajr.181.6.1811629 · Cited by 22
Nortunen, S., Flinkkilä, T. E., Lantto, I., Kortekangas, T. H. J., Niinimäki, J. L., Ohtonen, P. P., & Pakarinen, H. J. (2015) · The Bone & Joint Journal · doi:10.1302/0301-620x.97b8.35062 · Cited by 22
Pomini, F., Scavo, M., Ferrazzani, S., Carolis, S. D., Caruso, A., & Mancuso, S. (2001) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.1080/714052781 · Cited by 24
An alternative method of endotracheal intubation of common marmosets (Callithrix jacchus)
Thomas, A. W., Leach, M. C., & Flecknell, P. A. (2011) · Laboratory Animals · doi:10.1258/la.2011.011092 · Cited by 22
Bangma, C. H., van Schaik, R. H., BLIJENBERG, B. G., Roobol, M. J., Lilja, H. G., & Stenman, U. (2010) · European Journal of Cancer · doi:10.1016/j.ejca.2010.09.031 · Cited by 22
Automatic QRS Selvester scoring system in patients with left bundle branch block
Xia, X., Wieslander, B., Strauss, D. G., Wagner, G. S., Zaręba, W., Moss, A. J., & Couderc, J. (2015) · EP Europace · doi:10.1093/europace/euv040 · Cited by 22
Nakken, N., Janssen, D. J. A., van den Bogaart, E. H. A., Vercoulen, J. H. M. M., Wouters, E. F. �., & Spruit, M. A. (2014) · BMJ Open · doi:10.1136/bmjopen-2014-006098 · Cited by 27
Control maintenance can be predicted by exhaled NO monitoring in asthmatic patients
Ozier, A., Girodet, P., Bara, I., de Lara, J.-M. T., Marthan, R., & Berger, P. (2011) · Respiratory Medicine · doi:10.1016/j.rmed.2011.01.006 · Cited by 22
Yohannes, A. M. (2002) · Age and Ageing · doi:10.1093/ageing/31.5.355 · Cited by 22
Validación de una escala reducida de capacidad funcional del cuestionario WOMAC
Escobar, A., Vrotsou, K., Bilbao, A., Quintana, J. M., García‐Pérez, L., & Herrera-Espiñeira, C. (2011) · Gaceta Sanitaria · doi:10.1016/j.gaceta.2011.06.003 · Cited by 34
Hasani, F., MacDermid, J. C., Tang, A., & Kho, M. E. (2015) · Journal of Hand Therapy · doi:10.1016/j.jht.2015.05.003 · Cited by 23
Müller, M., Agten, C. A., Österreich, M., & Hoffmann, M. H. K. (2015) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2015.01.028 · Cited by 22
Arsicot, M., Lathelize, H., Martinez, R., Marchand, E., Picquet, J., & Enon, B. (2014) · Annals of Vascular Surgery · doi:10.1016/j.avsg.2014.03.034 · Cited by 22
Sølvik, U. Ø., Petersen, P. H., Monsen, G., Stavelin, A. V., & Sandberg, S. (2010) · Clinical Chemistry · doi:10.1373/clinchem.2010.146233 · Cited by 22
Krajewski, K. M., Nishino, M., Ramaiya, N. H., & Choueiri, T. K. (2015) · American Journal of Roentgenology · doi:10.2214/ajr.14.13236 · Cited by 22
Howells, O., Eperjesi, F., & Bartlett, H. E. (2012) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-012-2127-0 · Cited by 25
Maret, E., Brudin, L. H., Lindström, L., Nylander, E., Ohlsson, J. L., & Engvall, J. E. (2008) · Cardiovascular Ultrasound · doi:10.1186/1476-7120-6-55 · Cited by 22
Borchardt, S., & Staufenbiel, R. (2012) · Journal of the American Veterinary Medical Association · doi:10.2460/javma.240.8.1003 · Cited by 29
Cushman, D. M., McCormick, Z. L., CASEY, E. K., & Plastaras, C. T. (2015) · Pain Medicine · doi:10.1111/pme.12669 · Cited by 23
Technical note: Validating a dynamometer for noninvasive measuring of udder firmness in dairy cows
Bertulat, S., Fischer‐Tenhagen, C., Werner, A. T., & Heuwieser, W. (2012) · Journal of Dairy Science · doi:10.3168/jds.2012-5370 · Cited by 22
Faini, A., Omboni, S., Tifrea, M., Bubenek, Ș., Lazăr, O., & Parati, G. (2013) · Blood Pressure · doi:10.3109/08037051.2013.817121 · Cited by 24
Nguyen, M. T., Pham, I., Valensi, P. E., Rousseau, H., Vicaut, É., Laguillier, C., Nitenberg, A., & Cosson, E. (2014) · Cardiovascular Diabetology · doi:10.1186/1475-2840-13-20 · Cited by 23
Stewart, K. M., Mitchell, M. A., Norton, T. M., & Krecek, R. C. (2012) · Journal of Zoo and Wildlife Medicine · doi:10.1638/2011-0045r.1 · Cited by 22
Leung, Y.-Y., Png, M. E., Wee, H. L., & Thumboo, J. (2013) · The Journal of Rheumatology · doi:10.3899/jrheum.120782 · Cited by 22
Measurement properties of instruments assessing self-efficacy in patients with rheumatic diseases
Garratt, A., Løchting, I., Smedslund, G., & Hagen, K. B. (2013) · Rheumatology · doi:10.1093/rheumatology/ket374 · Cited by 31
Lee, L., Mata, J., Augustin, B., Carli, F., Morin, N. A., Latimer, E. A., & Feldman, L. S. (2014) · Journal of Surgical Research · doi:10.1016/j.jss.2014.02.016 · Cited by 24
Hoel, R. W., Albright, R. C., Beyer, L. K., Santrach, P. J., Magtibay, D. L., Everson, S. L., & McBane, R. D. (2008) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.03360708 · Cited by 22
Park, S. H., Choi, E. K., Lee, S. S., Woo, J. Y., Chung, S. Y., Kim, Y. J., Han, J. K., & Ha, H. K. (2007) · Radiology · doi:10.1148/radiol.2453061930 · Cited by 22
Bakhshandeh, H., Naderi, N., Amin, A., Taghavi, S., Dadashi, M., & Maleki, M. (2012) · Research in Cardiovascular Medicine · doi:10.5812/cardiovascmed.4186 · Cited by 25
Method of assessing involved facial areas: rule of fours
Yoon, H.-S., Choi, J., & Youn, J.-I. (2008) · British Journal of Dermatology · doi:10.1111/j.1365-2133.2008.08495.x · Cited by 22
Toyono, M., Pettersson, G., Matsumura, Y., Wada, N., Fukuda, S., Yamano, T., Takasaki, K., & Shiota, T. (2008) · Echocardiography · doi:10.1111/j.1540-8175.2008.00726.x · Cited by 22
Uterine artery Doppler ultrasound in postpartum women with retained placental tissue
Mulic‐Lutvica, A., Eurenius, K., & Axelssön, O. (2009) · Acta Obstetricia Et Gynecologica Scandinavica · doi:10.1080/00016340902934670 · Cited by 22
Is photometry an accurate and reliable method to assess boar semen concentration?
Camus, A., Camugli, S., Lévêque, C., Schmitt, É., & Staub, C. (2010) · Theriogenology · doi:10.1016/j.theriogenology.2010.09.025 · Cited by 22
Pratesi, S., Boni, L., Tofani, L., Berti, E., Sollai, S., & Dani, C. (2015) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.3109/14767058.2015.1113521 · Cited by 22
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.