STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 20,701–20,800 of 47,868
Schena, E., Lupi, G., Cecchini, S., & Silvestri, S. (2012) · Measurement · doi:10.1016/j.measurement.2012.05.009 · Cited by 21
Validity of sheet-type portable monitoring device for screening obstructive sleep apnea syndrome
Kobayashi, M., Namba, K., Tsuiki, S., Nakamura, M., Hayashi, M., Mieno, Y., Imizu, H., Fujita, S., Yoshikawa, A., Sakakibara, H., et al. (2012) · Sleep And Breathing · doi:10.1007/s11325-012-0725-z · Cited by 23
Assessment of Fever in African Children: Implication for Malaria Trials
Oyakhirome, S., Profanter, K., & Kremsner, P. G. (2010) · American Journal of Tropical Medicine and Hygiene · doi:10.4269/ajtmh.2010.09-0419 · Cited by 24
van den Boer, C., Muller, S. H., van der Noort, V., Olmos, R. A. V., Minni, A., Parrilla, C., Hilgers, F. J. M., van den Brekel, M. W. M., & van der Baan, S. (2014) · European Archives of Oto-Rhino-Laryngology · doi:10.1007/s00405-014-3336-4 · Cited by 22
Magnay, J. L., Schönicke, G., Nevatte, T. M., O’Brien, S., & Junge, W. (2011) · Fertility and Sterility · doi:10.1016/j.fertnstert.2011.05.096 · Cited by 21
Three-dimensional surface imaging system for assessing human obesity
Xu, B., Yu, W., Yao, M., Pepper, M. R., & FREELAND-GRAVES, J. H. (2009) · Optical Engineering · doi:10.1117/1.3250191 · Cited by 27
Assessment of EchoMRI-AH versus dual-energy X-ray absorptiometry to measure human body composition
Galgani, J. E., Smith, S. R., & Ravussin, E. (2011) · International Journal of Obesity · doi:10.1038/ijo.2010.268 · Cited by 21
Atherton, R. R., Williams, J. E., Wells, J. C. K., & Fewtrell, M. S. (2013) · PLoS ONE · doi:10.1371/journal.pone.0062139 · Cited by 26
Chotayaporn, T., Kasitanon, N., Sukitawut, W., & Louthrenoo, W. (2011) · JCR Journal of Clinical Rheumatology · doi:10.1097/rhu.0b013e318214bd18 · Cited by 21
Myint, K. S., Napolitano, A., Miller, S. R., Murgatroyd, P. R., Elkhawad, M., Nunez, D. J., & Finer, N. (2009) · Obesity · doi:10.1038/oby.2009.272 · Cited by 22
Hematuria Grading Scale: A New Tool for Gross Hematuria
Lee, J. Y., Chang, J. S., Koo, K. C., Lee, S. W., Choi, Y. D., & Cho, K. S. (2013) · Urology · doi:10.1016/j.urology.2013.04.048 · Cited by 21
Davis, J. A., Sorrentino, K. M., Ninness, E. M., Pham, P. H., Dorado, S., & Costello, K. B. (2006) · Clinical Physiology and Functional Imaging · doi:10.1111/j.1475-097x.2006.00674.x · Cited by 21
Huerva, V., Ascaso, F. J., Soldevila, J., & Lavilla, L. (2014) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2013.10.045 · Cited by 21
Oremus, M., Tarride, J., Clayton, N., & Raina, P. S. (2014) · Value in Health · doi:10.1016/j.jval.2013.10.009 · Cited by 21
Análisis de la composición corporal en mujeres con fibromialgia
Aparicio, V. A., Ortega, F. B., Heredia‐Jimenez, J., Carbonell‐Baeza, A., & Delgado‐Fernández, M. (2010) · Reumatología Clínica · doi:10.1016/j.reuma.2010.05.006 · Cited by 21
ELISA for antiphosphatidylethanolamine antibody detection: High impact of assay buffer on results
Sanmarco, M. (2010) · Journal of Immunological Methods · doi:10.1016/j.jim.2010.04.002 · Cited by 21
Relationship Between Quantitative CT of Pulmonary Small Vessels and Pulmonary Perfusion
Matsuoka, S., Yamashiro, T., Matsushita, S., Fujikawa, A., Yagihashi, K., Kurihara, Y., & Nakajima, Y. (2014) · American Journal of Roentgenology · doi:10.2214/ajr.13.11027 · Cited by 21
Automated Responsiveness Monitor to Titrate Propofol Sedation
Doufas, A. G., Morioka, N., Mahgoub, A. N., Bjorksten, A. R., Shafer, S. L., & Sessler, D. I. (2009) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181b0fd0f · Cited by 21
Thomson, A. J., Nimmo, A. F., Tiplady, B., & Glen, J. B. (2008) · Anaesthesia · doi:10.1111/j.1365-2044.2008.05683.x · Cited by 21
Acher, P. L., Rhode, K., Morris, S. L., Gaya, A. M., Miquel, M. E., Popert, R., Tham, I. W. K., Nichol, J., McLeish, K., Deehan, C., et al. (2008) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2008.03.065 · Cited by 21
Goldfarb, J. W., & Shinnar, M. (2006) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20609 · Cited by 21
Development and validation of tele-health system for stroke rehabilitation
Kizony, R., Weiss, P. L., Elion, O., Harel, S., Baum-Cohen, I., Krasovsky, T., Feldman, Y., & Shani, M. (2014) · International Journal on Disability and Human Development · doi:10.1515/ijdhd-2014-0329 · Cited by 25
Validity of a portable urine refractometer: The effects of sample freezing
Sparks, S. A., & Close, G. L. (2012) · Journal of Sports Sciences · doi:10.1080/02640414.2012.747693 · Cited by 26
Ashraf, M., Zhou, Z., Nguyen, T. D., Ashraf, S., & Sahn, D. J. (2011) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2011.09.001 · Cited by 21
Haisma, H. H., Coward, W. A., Albernaz, E., Barros, A. J. D., Victora, C. G., Wright, A., & Visser, G. H. (2004) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1602043 · Cited by 21
Stanković, Z. B., Fink, J., Collins, J. D., Semaan, E., Russe, M. F., Carr, J., Markl, M., Langer, M., & Jung, B. A. (2014) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-014-0456-1 · Cited by 21
Validation of a calcium assessment tool in postmenopausal Canadian women
Hung, A., Hamidi, M. S., Riazantseva, E., Thompson, L. U., Tile, L., TOMLINSON, G. A., Stewart, B., & Cheung, A. M. (2011) · Maturitas · doi:10.1016/j.maturitas.2011.02.016 · Cited by 21
López‐Miguel, A., Correa-Pérez, M. E., Miranda-Anta, S., Iglesias-Cortiñas, D., Coco-Martín, M. B., & Maldonado, M. J. (2012) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2011.11.039 · Cited by 21
Hope, C. K., Bakht, K., Burnside, G., Martin, G. C., Burnett, G. R., de Jong, E. J., & Higham, S. M. (2012) · Journal of Applied Microbiology · doi:10.1111/j.1365-2672.2012.05368.x · Cited by 21
Coquin, J., Bertarrex, A., Dewitte, A., Lefèvre, L. M., Joannès-Boyau, O., Fleureau, C., Winnock, S., Leuillet, S., Janvier, G., & Ouattara, A. (2013) · Anesthesiology · doi:10.1097/aln.0b013e3182833fcc · Cited by 21
Is oscillometric ankle pressure reliable in leg vascular disease?
Jönsson, B., Lindberg, L., Skau, T., & Thulesius, O. (2001) · Clinical Physiology · doi:10.1046/j.1365-2281.2001.00314.x · Cited by 21
Tian, L., Kellihan, H. B., Henningsen, J. D., Bellofiore, A., Forouzan, O., Roldán‐Alzate, A., Consigny, D. W., Gunderson, M., Dailey, S. H., François, C. J., et al. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.07.013 · Cited by 21
Rahmanou, P., Chaliha, C., Kulinskaya, E., & Khullar, V. (2008) · International Urogynecology Journal · doi:10.1007/s00192-008-0567-1 · Cited by 21
Chen, T., Yang, Z., Wang, Q., Li, Y., Qian, L., & Chen, H. (2010) · European Journal of Radiology · doi:10.1016/j.ejrad.2010.03.024 · Cited by 21
Dynamic postural stability for double-leg drop landing
Niu, W., Zhang, M., Fan, Y., & Zhao, Q. (2013) · Journal of Sports Sciences · doi:10.1080/02640414.2012.762600 · Cited by 21
Kim, H., Kim, Y.-J., Chang, S., Kim, D., Sohn, D., Oh, B., & Park, Y.-B. (2009) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2008.11.007 · Cited by 21
Olsen, S. Ø., Nielsen, L. H., Lantz, J., & Brännström, K. J. (2012) · International Journal of Audiology · doi:10.3109/14992027.2012.666362 · Cited by 21
Characterisation and reproducibility of a human ex vivo model of thrombosis
Lucking, A. J., Chelliah, R. K., Trotman, A. D., Connolly, T. M., Feuerstein, G., Fox, K. A. A., Boon, N. A., Badimón, J. J., & Newby, D. E. (2010) · Thrombosis Research · doi:10.1016/j.thromres.2010.06.030 · Cited by 21
Light measurement in the hospital: A comparison of two methods
Higgins, P. A., Winkelman, C., Lipson, A. R., Guo, S., & Rodgers, J. (2007) · Research in Nursing & Health · doi:10.1002/nur.20167 · Cited by 24
Hyperoxia‐induced arterial compliance decrease in healthy man
Rossi, P. M., & Boussuges, A. (2005) · Clinical Physiology and Functional Imaging · doi:10.1111/j.1475-097x.2004.00572.x · Cited by 21
Pang, D., Allaire, J., Rondenay, Y., Kaartinen, J., Cuvelliez, S., & Troncy, É. (2009) · Veterinary Anaesthesia and Analgesia · doi:10.1111/j.1467-2995.2008.00438.x · Cited by 21
Zhao, L. Y., Li, T., Lin, J., Tang, K., Zheng, S., Li, W., Cheng, D., Yin, W., & Zheng, X. (2015) · European Radiology · doi:10.1007/s00330-015-3592-8 · Cited by 21
Haeck, M. L. A., Scherptong, R. W. C., Antoni, M. L., Marsan, N. A., Vliegen, H. W., Holman, E. R., Schalij, M. J., Bax, J. J., & Delgado, V. (2012) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2012.03.005 · Cited by 24
Threshold determination in sweep VEP and the effects of criterion
Yadav, N. K., Almoqbel, F. M., Head, L. M., Irving, E. L., & Leat, S. J. (2009) · Documenta Ophthalmologica · doi:10.1007/s10633-009-9177-6 · Cited by 21
Turner, D., Griffiths, A. M., Steinhart, A. H., Otley, A. R., & Beaton, D. (2009) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2008.09.008 · Cited by 22
Poncumhak, P., Saengsuwan, J., & Amatachaya, S. (2013) · Journal of Spinal Cord Medicine · doi:10.1179/2045772313y.0000000160 · Cited by 21
Critchley, L. A. H. (2010) · Critical Care · doi:10.1186/cc9381 · Cited by 21
The Effects of Alcohol on Safety Behaviors in Socially Anxious Individuals
Battista, S. R., MacDonald, D., & Stewart, S. H. (2012) · Journal of Social and Clinical Psychology · doi:10.1521/jscp.2012.31.10.1074 · Cited by 21
Greco, A., Ragucci, M., Liuzzi, R., Gargiulo, S., Gramanzini, M., Coda, A. R. D., Albanese, S., Mancini, M., Salvatore, M., & Brunetti, A. (2012) · Sensors · doi:10.3390/s130100500 · Cited by 21
Ambrisko, T. D., Coppens, P., Kabeš, R., & Moens, Y. P. (2012) · British Journal of Anaesthesia · doi:10.1093/bja/aes269 · Cited by 21
Reproducibility of methods used for the assessment of autonomous nervous system's function
Tannus, L. R. M., Sperandei, S., Montenegro, R. M., Carvalho, V. R., Pedrosa, H. C., Félix, M. T., Canani, L. H. S., Zucatti, A. T. N., de Oliveira, D. H. A., Rea, R. R., et al. (2013) · Autonomic Neuroscience · doi:10.1016/j.autneu.2013.05.444 · Cited by 29
Investigating the Dutch Movement-Specific Reinvestment Scale in people with stroke
Kleynen, M., Braun, S., Beurskens, A. J. H. M., Verbunt, J., de Bie, R. A., & Masters, R. S. W. (2012) · Clinical Rehabilitation · doi:10.1177/0269215512448381 · Cited by 23
An evaluation of a novel instrument for measuring macular pigment optical density: the MPS 9000
Loughman, J., Scanlon, G., Nolan, J. M., O’Dwyer, V., & Beatty, S. (2011) · Acta Ophthalmologica · doi:10.1111/j.1755-3768.2011.02294.x · Cited by 23
Nguyen, C. T., Sharif‐Afshar, A., Fan, Z., Xie, Y., Wilson, S. P., Bi, X., Payor, L., Saouaf, R., Kim, H. L., & Li, D. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25609 · Cited by 21
Corneal mechanical sensitivity measurement using a staircase technique
Golebiowski, B., PAPAS, E. B., & Stapleton, F. J. (2005) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2005.00295.x · Cited by 21
van Venrooij, L. M. W., Verberne, H. J., de Vos, R., Borgmeijer-Hoelen, M. M. M. J., van Leeuwen, P. A. M., & de Mol, B. A. J. M. (2010) · Clinical Nutrition · doi:10.1016/j.clnu.2010.06.002 · Cited by 24
Translation and validation of the Danish version of the Patient Rated Wrist Evaluation questionnaire
Schønnemann, J. O., Hansen, T. B., & Søballé, K. (2013) · Journal of Plastic Surgery and Hand Surgery · doi:10.3109/2000656x.2013.787934 · Cited by 26
Tereshchenko, L. G., McCabe, A. R., Han, L., Sur, S., Huang, T., Marine, J. E., Cheng, A., SPRAGG, D. D., Sinha, S. K., Calkins, H. G., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2012.06.036 · Cited by 21
Vinyoles, E., Ribera, E. P., Casermeiro, J., de Prado, C., Jabalera, S., & Valencia, V. S. (2007) · Medicina Clínica · doi:10.1016/s0025-7753(07)72499-5 · Cited by 21
Point‐of‐care glucose monitoring on the neonatal unit
Makaya, T., Memmott, A., & Bustani, P. (2011) · Journal of Paediatrics and Child Health · doi:10.1111/j.1440-1754.2011.02253.x · Cited by 21
Preti, A., Sheehan, D. V., Coric, V., Distinto, M., Mirko, P., Vacca, I., Siddi, A., Masala, C., & Петретто, Д. Р. (2013) · Comprehensive Psychiatry · doi:10.1016/j.comppsych.2013.03.012 · Cited by 23
Anti-TNF inhibits the Airways neutrophilic inflammation induced by inhaled endotoxin in human
Michel, O., Dinh, P., Doyen, V., & Corazza, F. (2014) · BMC Pharmacology and Toxicology · doi:10.1186/2050-6511-15-60 · Cited by 21
Magnetic Resonance Arthrography for Assessing Severity of Glenohumeral Labroligamentous Lesions
Jana, M., Srivastava, D. N., Sharma, R., Gamanagatti, S. R., Nag, H., Mittal, R., & Upadhyay, A. D. (2012) · Journal of orthopaedic surgery · doi:10.1177/230949901202000219 · Cited by 21
North African reference equation for peak nasal inspiratory flow
Bouzgarou, M. D., Saad, H. B., Chouchane, A., Cheikh, I. B., Zbidi, A., Dessanges, J. F., & Tabka, Z. (2011) · The Journal of Laryngology & Otology · doi:10.1017/s0022215111000181 · Cited by 21
Khan, A. I. (2013) · Global Health Action · doi:10.3402/gha.v6i0.22476 · Cited by 25
Dawson, J. A., Bastrenta, P., Cavigioli, F., Thió, M., Ong, T., Siew, M. L., Hooper, S. B., & Davis, P. G. (2014) · Archives of Disease in Childhood Fetal & Neonatal · doi:10.1136/archdischild-2013-305091 · Cited by 21
The reliability of rating conversation as a measure of functional communication following stroke
Hesketh, A., Long, A., Patchick, E. L., Lee, J., & Bowen, A. (2008) · Aphasiology · doi:10.1080/02687030801952709 · Cited by 21
Trache, T., Stöbe, S., Tarr, A., Pfeiffer, D., & Hagendorff, A. (2014) · Echo Research and Practice · doi:10.1530/erp-14-0025 · Cited by 21
Fernandez, F., Almendral, J. M., Pachón, M., González‐Torrecilla, E., Martin, J. J., & GALLARDO, R. (2012) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.12079 · Cited by 21
Webster, J. D., Michalowski, A. M., Dwyer, J. E., Corps, K. N., Wei, B., Juopperi, T. A., Hoover, S. B., & Simpson, R. M. (2012) · Journal of Pathology Informatics · doi:10.4103/2153-3539.95130 · Cited by 21
Rustamov, O., Pemberton, P. W., Roberts, S. A., Smith, A., Yates, A. P., Patchava, S. D., & Nardo, L. G. (2010) · Fertility and Sterility · doi:10.1016/j.fertnstert.2010.10.001 · Cited by 21
Reliability Testing of the Pedestrian and Bicycling Survey (PABS) Method
Forsyth, A., Krizek, K. J., Agrawal, A. W., & Stonebraker, E. W. (2012) · Journal of Physical Activity and Health · doi:10.1123/jpah.9.5.677 · Cited by 24
Amundsen, B. H., Ericsson, M., Seland, J. G., Pavlin, T., Ellingsen, Ø., & Brekken, C. (2010) · Laboratory Animals · doi:10.1258/la.2010.010094 · Cited by 21
Rodrigues, S. L., Angelo, L. C., Pereira, A. C., Krieger, J. E., & Mill, J. G. (2008) · International Journal of Cardiology · doi:10.1016/j.ijcard.2008.03.066 · Cited by 21
Jia, G., O'Dell, C., Heverhagen, J. T., Yang, X., Liang, J., Jacko, R. V., Sammet, S., Pellas, T. C., Cole, P. E., & Knopp, M. V. (2008) · Radiology · doi:10.1148/radiol.2491071936 · Cited by 21
Huang, J., Lu, W., Savini, G., Hu, L., Pan, C., Wang, J., Tan, W., Chen, J., & Wang, Q. (2013) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2013.01.038 · Cited by 21
Marklund, M., Landberg, R., Åman, P., & Kamal‐Eldin, A. (2011) · Journal of Chromatography B · doi:10.1016/j.jchromb.2011.01.034 · Cited by 21
Kassab, G. S., Lontis, R., & Gregersen, H. N. (2004) · Annals of Biomedical Engineering · doi:10.1007/s10439-004-7817-2 · Cited by 21
Poller, L., Ibrahim, S., Keown, M., Pattison, A., & Jespersen, J. (2010) · Clinical Chemistry · doi:10.1373/clinchem.2009.141937 · Cited by 21
Prediction of total body muscle mass from simple anthropometric measurements in young Indian males.
McMillan, D. J., Davies, M. R., Browning, C. L., Good, M. F., & Sriprakash, K. S. (2004) · PubMed · Cited by 31
Henriksson, P., Löf, M., & Forsum, E. (2012) · British Journal Of Nutrition · doi:10.1017/s0007114512000906 · Cited by 23
Nasal Inspiratory Pressure: an Alternative for the Assessment of Inspiratory Muscle Strength?
Martínez‐Llorens, J., Ausín, P., Roig, A. M., Balañá, A., Admetlló, M., Muñoz, L., & Gea, J. (2011) · Archivos de Bronconeumología · doi:10.1016/s1579-2129(11)70042-8 · Cited by 26
Weber, M. A., Milstein, D. M. J., İnce, C., Rengerink, K. O., & Roovers, J. (2014) · Neurourology and Urodynamics · doi:10.1002/nau.22662 · Cited by 21
Adsuar, J. C., Olivares, P. R., Parraça, J. A., Hernández-Mocholí, M. A., & Gusi, N. (2012) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2012.08.198 · Cited by 23
Kunkel, D., Pickering, R. M., & Ashburn, A. (2011) · Age and Ageing · doi:10.1093/ageing/afq177 · Cited by 21
Jensen, E. W., Jospin, M., Gambús, P. L., Vallverdú, M., & Caminal, P. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4650472 · Cited by 21
Accuracy of Endoscopic Intraoperative Assessment of Urologic Stone Size
Patel, N., Chew, B. H., Knudsen, B. E., Lipkin, M. E., Wenzler, D., & Sur, R. L. (2013) · Journal of Endourology · doi:10.1089/end.2013.0707 · Cited by 21
Ruppel, J. K., Long, R. E., Oliver, D. R., Semb, G., Russell, K., Mercado, A. M., Daskalogiannakis, J., & Hathaway, R. R. (2015) · The Cleft Palate-Craniofacial Journal · doi:10.1597/15-030 · Cited by 21
Chinese cross-cultural adaptation and validation of the Oxford shoulder score
Xu, X., Wang, F., Wang, X., Wei, X., & Wang, Z. (2015) · Health and Quality of Life Outcomes · doi:10.1186/s12955-015-0383-5 · Cited by 21
Somani, D., Ray, S., Singh, S. K., & Mumbai, N. (2014) · Cited by 21
Barac, A., Lynce, F. C., Smith, K. L., Mete, M., Shara, N. M., Asch, F. M., Nardacci, M. P., Wray, L., Herbolsheimer, P. M., Nunes, R., et al. (2016) · Breast Cancer Research and Treatment · doi:10.1007/s10549-016-3678-2 · Cited by 24
Yanagisawa, S., Inden, Y., Kato, H., Miyoshi, A., Mizutani, Y., Ito, T., Kamikubo, Y., Kanzaki, Y., Hirai, M., & Murohara, T. (2016) · Circulation Journal · doi:10.1253/circj.cj-15-1152 · Cited by 21
Chen, S., Motonaga, K. S., Hollander, S. A., Almond, C. S. D., Rosenthal, D. N., Kaufman, B. D., May, L. J., Avasarala, K., Dao, D. T., Dubin, A. M., et al. (2016) · Heart Rhythm · doi:10.1016/j.hrthm.2016.02.014 · Cited by 21
Hourly Calculation Method of Air Source Heat Pump Behavior
Danza, L., Belussi, L., Meroni, I., Mililli, M., & Salamone, F. (2016) · Buildings · doi:10.3390/buildings6020016 · Cited by 23
Sánchez-Fructuoso, A. I., Pérez-Flores, I., Calvo, N., Valero, R., Matilla, E., Ortega, D., Dedo, M. A. D., Fernández, C., & Barrientos, A. (2012) · Therapeutic Drug Monitoring · doi:10.1097/ftd.0b013e318255cc15 · Cited by 21
Evaluation of the Corneal Endothelium Using Noncontact and Contact Specular Microscopy
Szalai, E., Németh, G., Berta, A., & Módis, L. (2010) · Cornea · doi:10.1097/ico.0b013e3182000807 · Cited by 21
Piedrahita‐Alonso, E., Valverde-Megías, A., & de Liaño, R. G. (2013) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2013-303680 · Cited by 21
Hansson, N. H., Tolbod, L. P., Harms, H. J., Wiggers, H., Kim, W. Y., Hansen, E. S. S., Zaremba, T., Frøkiær, J., Jakobsen, S., & Sørensen, J. (2016) · Journal of Nuclear Cardiology · doi:10.1007/s12350-015-0331-0 · Cited by 21
Corneal Power Measurement Obtained by Fourier-Domain Optical Coherence Tomography
Wang, Q., Hua, Y., Savini, G., Chen, H., Bao, F., Lin, S., Lu, W., & Huang, J. (2015) · Cornea · doi:10.1097/ico.0000000000000564 · Cited by 21
Carnevale, V., Pastore, L., Camaioni, M., Mellozzi, M., Sabatini, M., Arietti, E., Fusilli, S., Scillitani, A., & Pontecorvi, M. (2010) · Journal of Nephrology · doi:10.1093/joneph/23.3.306 · Cited by 21
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.