STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 22,301–22,400 of 47,868
A comparison of two different assays for determining S-100B in serum and urine
Hallén, M., Carlhed, R., Karlsson, M., Hallgren, T., & Bergenheim, M. (2008) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2008.190 · Cited by 19
Basal metabolic rate of Brazilians living in the Southwestern United States
Wahrlich, V., dos Anjos, L. A., Going, S. B., & Lohman, T. G. (2006) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1602498 · Cited by 22
van der Meer, N. J. M., de Vries, J. P. P. M., Schreuder, W. O., Bulder, E. R., Eysman, L., & VRIES, P. M. J. M. D. (1997) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.1997.tb04770.x · Cited by 19
Sharma, S., Boujraf, S., Bornstedt, A., Hombach, V., Ignatius, A. A., Oberhuber, A., & Rasche, V. (2010) · Investigative Radiology · doi:10.1097/rli.0b013e3181c8cefa · Cited by 19
Golzan, M., Kim, M., Seddighi, A. S., Avolio, A. P., & Graham, S. L. (2012) · Annals of Biomedical Engineering · doi:10.1007/s10439-012-0563-y · Cited by 19
Serra, J. A., Marschoff, E. R., Domínguez, R. O., de Lustig, E. S., Famulari, A. L., Bartolomé, E. L., & Guareschi, E. M. (2000) · Clinica Chimica Acta · doi:10.1016/s0009-8981(00)00326-0 · Cited by 19
Okuda, N., Ito, T., Emura, N., Suwa, M., Hayashi, T., Yoneda, H., & Kitaura, Y. (2007) · CHEST Journal · doi:10.1378/chest.06-2444 · Cited by 19
Ivy, D. D., Neish, S. R., Knudson, O. A., Nihill, M. R., Schaffer, M. S., Tyson, R. W., Abman, S. H., Shaffer, E., & Valdes‐Cruz, L. M. (1998) · The American Journal of Cardiology · doi:10.1016/s0002-9149(97)01031-x · Cited by 19
Rizos, T., Jenetzky, E., Herweh, C., Unterberg, A. W., Hacke, W., & Veltkamp, R. C. (2010) · Neurocritical Care · doi:10.1007/s12028-010-9443-1 · Cited by 19
Ekmann, A., Rigdal, M., & Gröndahl, G. (2009) · Veterinary Clinical Pathology · doi:10.1111/j.1939-165x.2009.00203.x · Cited by 19
Gramse, V., Groote, A. D., & Paiva, M. (2003) · Annals of Biomedical Engineering · doi:10.1114/1.1540636 · Cited by 19
The reliability of measuring quadriceps cross‐sectional area with compound B ultrasound scanning
Howe, T. E., & Oldham, J. A. (1996) · Physiotherapy Research International · doi:10.1002/pri.6120010207 · Cited by 24
Mihalcea, D. J., Florescu, M., Suran, B., Enescu, O. A., Mincu, R. I., Magda, S. L., Pătraşcu, N., & Vinereanu, D. (2015) · Heart and Vessels · doi:10.1007/s00380-015-0632-x · Cited by 19
Current developments in measurement of corneal topography
Dave, T. (1998) · Contact Lens and Anterior Eye · doi:10.1016/s1367-0484(98)80034-9 · Cited by 19
High resolution magnetic resonance imaging in atherosclerotic mice treated with ezetimibe
Dietrich, T., Hucko, T., Bourayou, R., Jahnke, C., Paetsch, I., Atrott, K., Stawowy, P., Gräfe, M., Klein, C., Schnackenburg, B., et al. (2009) · International journal of cardiac imaging · doi:10.1007/s10554-009-9487-5 · Cited by 19
Tyl, B., Kabbaj, M., Fassi, B., Jode, P. D., & Wheeler, W. M. (2009) · The Journal of Clinical Pharmacology · doi:10.1177/0091270009337944 · Cited by 21
Poca, M. A., Sahuquillo, J., Barba, M. A., Añez, J. D., & Arikán, F. (2004) · Journal of neurosurgery · doi:10.3171/jns.2004.100.2.0260 · Cited by 19
Bridge, P., POCOCK, N. A., Nguyen, T. V., Munns, C. F., Cowell, C. T. C. T., & Thompson, M. W. (2009) · Journal of Pediatric Endocrinology and Metabolism · doi:10.1515/jpem.2009.22.9.795 · Cited by 21
Li, F., Wang, Q., Yao, G., Zhang, P. F., Ge, Z. M., Zhang, M., & Zhang, Y. (2007) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2007.07.012 · Cited by 19
Mitchell, P. J., Klarskov, N., Telford, K., Hosker, G. L., Lose, G., & Kiff, E. S. (2011) · Diseases of the Colon & Rectum · doi:10.1097/dcr.0b013e318223fbcb · Cited by 19
Three-Dimensional Intravascular Ultrasound Assessment of Abdominal Aortic Aneurysm Necks
van Essen, J. A., Gussenhoven, E. J., Blankensteijn, J. D., Honkoop, J., van Dijk, L. C., van Sambeek, M. R. H. M., & van der Lugt, A. (2000) · Journal of Endovascular Therapy · doi:10.1177/152660280000700505 · Cited by 19
Lee, M. Y., Kanavakis, G., & Miner, R. M. (2014) · The Angle Orthodontist · doi:10.2319/021814-120.1 · Cited by 19
Peak Velocity and Flow Quantification Validation for Sensitivity-Encoded Phase-Contrast MR Imaging
Lew, C., Alley, M. T., Bammer, R., Spielman, D. M., & Chan, F. P. (2007) · Academic Radiology · doi:10.1016/j.acra.2006.11.008 · Cited by 19
Reproducibility of Acoustic Rhinometry in the Investigation of Occupational Rhinitis
Castaño, R., Theriault, G. P., Gautrin, D., Ghezzo, H., Trudeau, C., & Malo, J. (2007) · American Journal of Rhinology · doi:10.2500/ajr.2007.21.3039 · Cited by 19
Contrast and glare sensitivity in diabetic patients with and without pan-retinal photocoagulation
Mackie, S., & Walsh, G. (1998) · Ophthalmic and Physiological Optics · doi:10.1016/s0275-5408(97)00083-5 · Cited by 19
Exercise might bias skeletal-muscle fat fraction calculation from Dixon images
Fischmann, A., Kaspar, S., Reinhardt, J., Gloor, M., Stippich, C., & Fischer, D. (2012) · Neuromuscular Disorders · doi:10.1016/j.nmd.2012.05.014 · Cited by 19
Xia, R., ODEMUYIWA, O., Gill, J., Malík, M., & Camm, A. J. (1993) · International Journal of Bio-Medical Computing · doi:10.1016/0020-7101(93)90016-y · Cited by 22
LI, L. C., Moja, L., Romero, A., Sayre, E. C., & Grimshaw, J. (2009) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2008.10.008 · Cited by 23
Toksvang, L. N., Plovsing, R. R., Petersen, M. W., Møller, K., & Berg, R. M. G. (2014) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12120 · Cited by 20
Bevilacqua, P., Verderio, P., Barbareschi, M., Bonoldi, E., Boracchi, P., Palma, P. D., & Gasparini, G. (1996) · Breast Cancer Research and Treatment · doi:10.1007/bf01806494 · Cited by 19
Anderson, J., Manias, E., Kusljic, S., & Finch, S. J. (2013) · Research in Social and Administrative Pharmacy · doi:10.1016/j.sapharm.2013.04.013 · Cited by 19
Pallett, E. J., Rentowl, P., Johnson, M. I., & Watson, P. (2013) · Clinical Journal of Pain · doi:10.1097/ajp.0b013e31828dc828 · Cited by 23
Gruszczyńska, K., Krzych, Ł. J., Golba, K. S., Biernat, J., Roleder, T., Deja, M. A., Ulbrych, P., Malinowski, M., Janusiewicz, P., Woś, S., et al. (2012) · Medical Science Monitor · doi:10.12659/msm.882507 · Cited by 19
Franco, P. G., Bohrer, R. C. D., & Rodacki, A. L. F. (2012) · Brazilian Journal of Physical Therapy · doi:10.1590/s1413-35552012005000062 · Cited by 20
Field Evaluation of a Personal, Bioaerosol Cyclone Sampler
Macher, J. M., Chen, B. T., & Rao, C. Y. (2008) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620802400159 · Cited by 19
Efficient screening for COPD using three steps: a cross-sectional study in Mexico City
Franco‐Marina, F., Fernández-Plata, R., Torre-Bouscoulet, L. I., García-Sancho, C., Sánchez-Gallén, E., Martinez, D., Pérez‐Padilla, R., & for the Study Team (2014) · npj Primary Care Respiratory Medicine · doi:10.1038/npjpcrm.2014.2 · Cited by 20
Mejía‐Rodríguez, F., Orjuela, M. A., García‐Guerra, A., Quezada-Sanchez, A. D., & Neufeld, L. M. (2011) · Maternal and Child Health Journal · doi:10.1007/s10995-011-0912-8 · Cited by 21
Baad‐Hansen, T., Kold, S., Kaptein, B. L., & Søballé, K. (2007) · Acta Orthopaedica · doi:10.1080/17453670710014095 · Cited by 19
Submaximal exercise and maturation in 12-year-olds
Armstrong, N. (1999) · Journal of Sports Sciences · doi:10.1080/026404199366208 · Cited by 19
Yin, M., Hou, Y., Zhang, T., Cui, C., Zhou, X., Sun, F., Li, H., Li, X., Zheng, J., Chen, X., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0054969 · Cited by 20
The Effect of Angulation on Intravascular Ultrasound Imaging Observed in Vascular Phantoms
Geselschap, J. H., Heilbron, M., Hussain, F., Daskalakis, T., Wilson, E. P., Kopchok, G. E., & White, R. A. (1998) · Journal of Endovascular Therapy · doi:10.1177/152660289800500206 · Cited by 19
Concordance analysis between estimation methods of milk fatty acid content
Rodriguez, M. A. P., Petrini, J., Ferreira, E. M., Mourão, L. R. M. B., Salvian, M., Cassoli, L. D., Pires, A. V., Machado, P. F., & Mourão, G. B. (2014) · Food Chemistry · doi:10.1016/j.foodchem.2014.01.092 · Cited by 23
Gianesin, B., Zefiro, D., Musso, M., Rosa, A., Bruzzone, C., Balocco, M., Carrara, P., Bacigalupo, L., Banderali, S., Rollandi, G. A., et al. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23148 · Cited by 19
Raff, G. L., O’Neill, W. W., Gentry, R. E., Dulli, A., Bis, K. G., Shetty, A. N., & Goldstein, J. A. (2006) · Radiology · doi:10.1148/radiol.2402050369 · Cited by 19
Intraocular pressure measurement in children using the Keeler Pulsair tonometer
Gregory-Evans, K., & Wishart, P. K. (1992) · Ophthalmic and Physiological Optics · doi:10.1016/0275-5408(92)90214-h · Cited by 19
Ramaciotti, C., Lemler, M. S., Moake, L., & Zellers, T. M. (2002) · Journal of the American Society of Echocardiography · doi:10.1067/mje.2002.124573 · Cited by 19
Nérette, P., Dohoo, I. R., Hammell, K. L., Gagné, N., Barbash, P. A., MacLean, S., & Yason, C. (2005) · Journal of Fish Diseases · doi:10.1111/j.1365-2761.2005.00613.x · Cited by 19
Assessment of the distraction regenerate using three-dimensional quantitative computer tomography
Swennen, G. R. J., Eulzer, C., Schutyser, F., Hüttmann, C., & Schliephake, H. (2004) · International Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.ijom.2004.03.019 · Cited by 19
Wang, J., & Morigen, M. (2009) · BMC Bioinformatics · doi:10.1186/1471-2105-10-345 · Cited by 22
Validity of simplified protocols to estimate glomerular filtration rate using iohexol clearance
James, T. J., Lewis, A. V., Tan, G. D., Altmann, P., Taylor, R. P., & Lévy, J. (2007) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1258/000456307780945804 · Cited by 19
Meganck, V., Goddeeris, B. M., Stuyven, E., Piepers, S., Cox, E., & OPSOMER, G. (2014) · The Veterinary Journal · doi:10.1016/j.tvjl.2014.02.021 · Cited by 19
Papavassiliu, T., K�hl, H. P., van Dockum, W. G., Hofman, M. B. M., Bondarenko, O., Beek, A. M., & van Rossum, A. C. (2004) · Journal of Cardiovascular Magnetic Resonance · doi:10.1081/jcmr-200036157 · Cited by 26
Stucki, G., Hardegger, D., Böhni, U. W., & Michel, B. A. (1999) · Clinical Rheumatology · doi:10.1007/s100670050090 · Cited by 19
Lu, T.-L. C., Meuli, R. A., Marques-Vidal, P. M., Bize, P., Denys, A. L., & Schmidt, S. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22301 · Cited by 19
Validation of the Tunisian version of the Roland-Morris questionnaire
Bejia, I., Younès, M., Salem, K. B., Letaief, M., Touzi, M., Soltani, M. S., & Bergaoui, N. (2004) · European Spine Journal · doi:10.1007/s00586-004-0730-4 · Cited by 19
A clinical evaluation of an oscillometric blood pressure monitor on anesthetized horses
Branson, K. (1997) · Journal of Equine Veterinary Science · doi:10.1016/s0737-0806(97)80226-2 · Cited by 19
Memtsoudis, S. G., Jules-Elysee, K. M., Girardi, F. P., Buschiazzo, V., Maalouf, D. B., Sama, A. A., & Urban, M. K. (2008) · Spine · doi:10.1097/brs.0b013e31817c6c2f · Cited by 19
Pulse Transit Time Based on Piezoelectric Technique at the Radial Artery
Foo, J. Y. A., & Lim, C. S. (2006) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-006-9019-y · Cited by 19
Yager, C., Wehrli, S. L., & Segal, S. (2005) · Clinica Chimica Acta · doi:10.1016/j.cca.2005.10.015 · Cited by 19
Air trapping is a major determinant of persistent airway obstruction in asthmatics
Park, H., Park, J.-S., Jeong, S. H., Lee, Y. N., Hwangbo, Y., Park, J., Lee, J.-H., Jang, A., Kim, D.-J., Uh, S. T., et al. (2012) · Respiratory Medicine · doi:10.1016/j.rmed.2012.02.012 · Cited by 19
Low Numeracy Predicts Reduced Accuracy of Retrospective Reports of Frequency of Sexual Behavior
McAuliffe, T. L., DiFranceisco, W. J., & Reed, B. R. (2010) · AIDS and Behavior · doi:10.1007/s10461-010-9761-5 · Cited by 20
Performance Evaluation of Nine Hormone Assays on the Immulite 2000®Immunoassay System
Tello, F. L., & Hernández, D. M. (2000) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2000.154 · Cited by 19
Hurst, H. T., & Atkins, S. J. (2006) · Journal of Sports Sciences · doi:10.1080/02640410500245678 · Cited by 19
Ganio, M. S., Brothers, R. M., Lucas, R. A. I., Hastings, J. L., & Crandall, C. G. (2011) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00247.2011 · Cited by 19
Hakki's Formula for Measurement of Aortic Valve Area by Magnetic Resonance Imaging
Puymirat, É., Chassaing, S., Trinquart, L., Barbey, C., Chaudeurge, A., Bar, O., & Blanchard, D. (2010) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2010.03.019 · Cited by 19
Echocardiographic Assessment of Ejection Fraction in Left Ventricular Hypertrophy
Wandt, Bojö, Tolagen, & Wranne (1999) · Clinical Physiology · doi:10.1046/j.1365-2281.1999.ab02k.x · Cited by 19
Statistical methods for assessing agreement between double readings of clinical measurements
Vieira, S., & Corrente, J. E. (2011) · Journal of Applied Oral Science · doi:10.1590/s1678-77572011000500009 · Cited by 19
Reliability of the 1 RM bench press and squat in young women
Augustsson, S. R., & Svantesson, U. M. (2013) · European Journal of Physiotherapy · doi:10.3109/21679169.2013.810305 · Cited by 24
Bronchoscopy in Ventilator-associated Pneumonia
Afessa, B., Hubmayr, R. D., Vetter, E. A., Keegan, M. T., Swanson, K. L., Baddour, L. M., Cockerill, F. R., & Peters, S. G. (2006) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200512-1899oc · Cited by 19
Gillen, L. J., & Tapsell, L. C. (2004) · Journal of the American Dietetic Association · doi:10.1016/j.jada.2004.09.021 · Cited by 22
Madsen, O. R. (2011) · Clinical Rheumatology · doi:10.1007/s10067-011-1847-6 · Cited by 19
Borgard, J.-P., Szymanowicz, A., Pellae, I., Szmidt-Adjidé, V., & Rota, M. (2006) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2006.202 · Cited by 19
Liu, F., Liu, S.-A., Ma, Z., Zhan, X., Tao, G., Cheng, L., & Song, X. (2012) · Journal of Obstetrics and Gynaecology · doi:10.3109/01443615.2011.645092 · Cited by 19
Are the Multidimensional Body Self-Relations Questionnaire Scales stable or transient?
Nevill, A. M., Lane, A. M., & Duncan, M. J. (2015) · Journal of Sports Sciences · doi:10.1080/02640414.2015.1018930 · Cited by 23
Monti, M., Monti, A., Murdolo, G., Renzi, P. D., Pirro, M. R., Borgognoni, F., & Vincentelli, G. M. (2014) · Scandinavian Cardiovascular Journal · doi:10.3109/14017431.2014.942872 · Cited by 21
Abul‐Kasim, K., Karlsson, M. K., Hasserius, R., & Ohlin, A. (2010) · Scoliosis · doi:10.1186/1748-7161-5-4 · Cited by 19
Effect of Chronic Oral Supplementation with Vitamins on the Endothelial Function in Chronic Smokers
Takase, B., Etsuda, H., Matsushima, Y., Ayaori, M., Kusano, H., Hamabe, A., Uehata, A., Ohsuzu, F., Ishihara, M., & Kurita, A. (2004) · Angiology · doi:10.1177/00033197040550i606 · Cited by 21
Analytical validation of serum bone alkaline phosphatase (BAP OSTASE) on Liaison
Cavalier, E., Rozet, E., Carlisi, A., Bekaert, A.-C., Rousselle, O., Hubert, P., Chapelle, J.-P., & Delanaye, P. (2009) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2010.019 · Cited by 19
Yu, Y., Simaan, M. A., Mushi, S. E., & Zorn, N. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.903524 · Cited by 19
A phantom study of nodule size evaluation with chest tomosynthesis and computed tomography
Johnsson, Å. A., Svalkvist, A., Vikgren, J., Boijsen, M., Flinck, A., Kheddache, S., & Båth, M. (2010) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncq003 · Cited by 19
Galantino, M. L., Kietrys, D. M., Parrott, J. S., Stevens, M. R., Stevens, A. M., & Condoluci, D. V. (2014) · Physical Therapy · doi:10.2522/ptj.20130337 · Cited by 19
Fixation Stability Measurement Using Two Types of Microperimetry Devices
Liu, H., Bittencourt, M. G., Sophie, R., Sepah, Y. J., Hanout, M., Rentiya, Z., Annam, R., Scholl, H. P. N., & Nguyen, Q. D. (2015) · Translational Vision Science & Technology · doi:10.1167/tvst.4.2.3 · Cited by 25
Hetzler, R. K., Kimura, I. F., Haines, K., LaBotz, M., & Smith, J. U. (2006) · Europe PMC (PubMed Central) · Cited by 19
Pavlopoulos, H., & Nihoyannopoulos, P. (2008) · European Journal of Echocardiography · doi:10.1093/ejechocard/jen324 · Cited by 19
Measurement of Volumetric Flow by Real-time 3-Dimensional Doppler Echocardiography in Children
Lu, X., Nadvoretskiy, V. V., Klas, B., Bu, L., Stolpen, A. H., Ayres, N. A., Sahn, D. J., & Ge, S. (2007) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2007.01.025 · Cited by 19
Supej, M., & Čuk, I. (2014) · Sensors · doi:10.3390/s141223490 · Cited by 19
Assessment of anemia during CT pulmonary angiography
Jung, C., Groth, M., Bley, T. A., Henes, F. O., Treszl, A., Adam, G., & Bannas, P. (2012) · European Journal of Radiology · doi:10.1016/j.ejrad.2012.07.008 · Cited by 19
Riquelme, I., Cifré, I., & Montoya, P. (2014) · Disability and health journal · doi:10.1016/j.dhjo.2014.08.009 · Cited by 20
Oyaert, M., Laer, C. V., Claerhout, H., Vermeersch, P., Desmet, K., Pauwels, S., & Kieffer, D. (2014) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.12305 · Cited by 19
Assessing mood in patients with multiple sclerosis
Groom, M. J., Lincoln, N. B., Francis, V. M., & Stephan, T. F. (2003) · Clinical Rehabilitation · doi:10.1191/0269215503cr688oa · Cited by 19
Freezing of homogenized sputum samples for intermittent storage
Holz, O., Mücke, M., Zarza, P., Loppow, D., Jörres, R., & MAGNUSSEN, H. (2001) · Clinical & Experimental Allergy · doi:10.1046/j.1365-2222.2001.01136.x · Cited by 19
Wöpking, S., Scherens, A., Haussleiter, I. S., Richter, H., Schüning, J., Klauenberg, S., & Maier, C. (2009) · BMC Neurology · doi:10.1186/1471-2377-9-13 · Cited by 24
Soares, O. A. B., Ferraz, G. D. C., Martins, C., Dias, D. P. M., Neto, J. C. D. L., & Queiroz-Neto, A. (2014) · Arquivo Brasileiro de Medicina Veterinária e Zootecnia · doi:10.1590/s0102-09352014000100007 · Cited by 25
Lower Extremity Joint Angle Tracking with Wireless Ultrasonic Sensors during a Squat Exercise
Qi, Y., Soh, C. B., Gunawan, E., Low, K., & Thomas, R. (2015) · Sensors · doi:10.3390/s150509610 · Cited by 19
Refining the latent structure of neuropsychological performance in schizophrenia
Lam, M., Collinson, S. L., Eng, G. K., Rapisarda, A., Kraus, M., Lee, J., Chong, S. A., & Keefe, R. S. E. (2014) · Psychological Medicine · doi:10.1017/s0033291714001020 · Cited by 19
Christensen, B. H., Andersen, K. S., Pedersen, K. S., Bengtsen, B. S., Simonsen, O. H., Kappel, S. L., & Rathleff, M. S. (2014) · Journal of Foot and Ankle Research · doi:10.1186/1757-1146-7-12 · Cited by 27
Validating hospital antibiotic purchasing data as a metric of inpatient antibiotic use
Tan, C., Ritchie, M., Alldred, J., & Daneman, N. (2015) · Journal of Antimicrobial Chemotherapy · doi:10.1093/jac/dkv373 · Cited by 19
Statistical methods for the comparison of measurements derived from orthodontic imaging
Krummenauer, F. (2000) · European Journal of Orthodontics · doi:10.1093/ejo/22.3.257 · Cited by 19
Predictive formulas for food base excess and urine pH estimations of cats
Jeremias, J. T., Nogueira, S. P., Brunetto, M. R., Pereira, G. T., Loureiro, B. A., Ferreira, C. S., Gomes, M. D. O. S., & Carciofí, A. C. (2013) · Animal Feed Science and Technology · doi:10.1016/j.anifeedsci.2013.04.003 · Cited by 19
de Visscher, J. G. A. M., Schaapveld, M., Grond, A. J. K., & van der Waal, I. (1999) · Oral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology · doi:10.1016/s1079-2104(99)70107-1 · Cited by 19
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.