STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 22,401–22,500 of 47,868
Shemesh, T., Rowley, K., Jenkins, A. J., Best, J. D., & O’Dea, K. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2008.115360 · Cited by 20
Mφller, L. N. O., Knudsen, A. R., Andersen, K. J., Nyengaard, J. R., Hamilton-Dutoit, S. J., Mφller, E. M. O., Svendsen, P., Møller, H. J., Moestrup, S. K., Graversen, J. H., et al. (2015) · Annals of Medicine and Surgery · doi:10.1016/j.amsu.2015.09.001 · Cited by 19
Cahill, N. E., Day, A. G., Cook, D., & Heyland, D. K. (2013) · Implementation Science · doi:10.1186/1748-5908-8-140 · Cited by 21
Combined Oximetry-Cutaneous Capnography in Patients Assessed for Long-term Oxygen Therapy
Török, S. S., Leuppi, J. D., Baty, F., Tamm, M., & Chhajed, P. N. (2008) · CHEST Journal · doi:10.1378/chest.07-0960 · Cited by 19
Impact of exercise testing mode on exercise parameters in patients with chronic heart failure
Beckers, P. J., Possemiers, N. M., Craenenbroeck, E. M. V., Berendoncks, A. M. V., Wuyts, K., Vrints, C. J., & Conraads, V. M. (2011) · European Journal of Preventive Cardiology · doi:10.1177/1741826711400664 · Cited by 21
Walsh, J., Barrett, A., Murray, D., Ryan, J., Moroney, J. T., & Shannon, M. (2010) · Disability and Rehabilitation · doi:10.3109/09638280903171576 · Cited by 19
Rösner, A., Avenarius, D. F. M., Malm, S., Iqbal, A., Baltabaeva, A., Sutherland, G. R., Bijnens, B. H., & Myrmel, T. (2012) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jes036 · Cited by 21
Greco, A., Petretta, M. P., Larobina, M., Gargiulo, S., Panico, M., Nekolla, S. G., Esposito, G., Petretta, M., Brunetti, A., & Cuocolo, A. (2012) · Journal of Nuclear Cardiology · doi:10.1007/s12350-012-9538-5 · Cited by 19
Moreira, S. R., Lima, R. M., Silva, K. E. D. S., & Simões, H. G. (2014) · Brazilian Journal of Physical Therapy · doi:10.1590/s1413-35552012005000135 · Cited by 24
Interplay between Field Measurements and Soil Behavior for Capturing Supported Excavation Response
Osouli, A., Hashash, Y. M. A., & Song, H. (2009) · Journal of Geotechnical and Geoenvironmental Engineering · doi:10.1061/(asce)gt.1943-5606.0000201 · Cited by 19
Kim, T. B., Oh, J. K., Kim, K. T., Yoon, S. J., & Kim, S. W. (2015) · PLoS ONE · doi:10.1371/journal.pone.0143054 · Cited by 19
Kaufmann, P. A., Namdar, M., Matthew, F., Roffi, M., Aschkenasy, S. V., van der Loo, B., Sütsch, G., Lüscher, T. F., & Jenni, R. (2005) · PubMed · Cited by 20
Renal depth estimates to improve the accuracy of glomerular filtration rate.
Ap, S., Zwas, S. T., Macadziob, S., Rotemberg, G., & Shrem, Y. (1998) · PubMed · Cited by 19
A Method For Tree-Ring Analysis UsingDiva-GisFreeware On Scanned Core Images
Arenas‐Castro, S., Fernández-Haeger, J., & Jordano, D. (2015) · Tree-Ring Research · doi:10.3959/1536-1098-71.2.118 · Cited by 22
Tian, M., Miao, H., Shen, Y., Gao, J., Mo, X., & Zhou, X. (2015) · PLoS ONE · doi:10.1371/journal.pone.0142189 · Cited by 19
Kok, J., Ng, J., Li, S. C., Giannoutsos, J., Nayyar, V., Iredell, J. R., Dwyer, D. E., & Chen, S. C. ‐. (2015) · Pathology · doi:10.1097/pat.0000000000000296 · Cited by 19
Seidel, J. A., Andrews, W. P., Owen, J. J., Miller, S. D., & Buccino, D. L. (2016) · Psychological Assessment · doi:10.1037/pas0000311 · Cited by 27
Labbé, V., Éderhy, S., Pasquet, B., Miguel-Montanes, R., Rafat, C., Hajage, D., Gaudry, S., Dreyfuss, D., Cohen, A. A., Fartoukh, M. S., et al. (2016) · Annals of Intensive Care · doi:10.1186/s13613-016-0150-8 · Cited by 19
Tadić, V., Cumberland, P. M., Lewando‐Hundt, G., & Rahi, J. S. (2016) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2016-308582 · Cited by 20
Pazzaglia, U. E., Congiu, T., Sibilia, V., Pagani, F., Benetti, A., & Zarattini, G. (2016) · Journal of Morphology · doi:10.1002/jmor.20568 · Cited by 19
Automated, continuous and non-invasive assessment of pulse pressure variations using CNAP® system
Biais, M., Stecken, L., Martin, A., Roullet, S., Quinart, A., & Sztark, F. (2016) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-016-9899-4 · Cited by 19
Radiolucency in stemless shoulder arthroplasty is associated with an imaging phenomenon
Hudek, R., Werner, B. S., Abdelkawi, A. F., Schmitt, R. R., & Gohlke, F. (2016) · Journal of Orthopaedic Research® · doi:10.1002/jor.23478 · Cited by 19
Systematic Characterization of Dynamic Parameters of Intracellular Calcium Signals
Mackay, L., Mikolajewicz, N., Komarova, S. V., & Khadra, A. (2016) · Frontiers in Physiology · doi:10.3389/fphys.2016.00525 · Cited by 19
Nyström, C. D., Henriksson, H., Alexandrou, C., Bergström, A., Bonn, S. E., Bälter, K. A., & Löf, M. (2017) · Nutrients · doi:10.3390/nu9010066 · Cited by 25
Non-invasive Measures of Core Temperature versus Ingestible Thermistor during Exercise in the Heat
Fogt, D. L., Henning, A. L., Venable, A. S., & McFarlin, B. K. (2017) · International journal of exercise science · doi:10.70252/mgqg4687 · Cited by 19
Brooks, M., Legendre, G., Brun, S., Bouet, P., Mendes, L. P., Merlot, B., & Sentilhes, L. (2017) · Scientific Reports · doi:10.1038/srep46333 · Cited by 23
Kato, E., Takachi, R., Ishihara, J., Ishii, Y., Sasazuki, S., Sawada, N., Iwasaki, M., Shinozawa, Y., Umezawa, J., Tanaka, J., et al. (2017) · Journal of Epidemiology · doi:10.1016/j.je.2016.08.021 · Cited by 21
Beretta-Piccoli, M., D’Antona, G., Zampella, C., Barbero, M., Clijsen, R., & Cescon, C. (2017) · Physiological Measurement · doi:10.1088/1361-6579/aa614c · Cited by 19
Aberrometry Repeatability and Agreement with Autorefraction
Nguyen, M. T., & Berntsen, D. A. (2017) · Optometry and Vision Science · doi:10.1097/opx.0000000000001107 · Cited by 19
Validation of the 3-Minute All-Out Exercise Test for Shuttle Running Prescription
Saari, A., Dicks, N. D., Hartman, M. E., & Pettitt, R. W. (2017) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000002120 · Cited by 19
Baiardini, I., Braido, F., Molinengo, G., Caminati, M., Costantino, M. T., Cristaudo, A., Crivellaro, M., Ferrucci, S. M., Gallo, R., Giorgis, V. D., et al. (2017) · The Journal of Allergy and Clinical Immunology In Practice · doi:10.1016/j.jaip.2017.06.023 · Cited by 21
Palmer, S., Manns, S., Cramp, F. L., Lewis, R., & Clark, E. (2017) · Musculoskeletal Science and Practice · doi:10.1016/j.msksp.2017.08.007 · Cited by 21
Abdullayev, N., Neuhaus, V., Bratke, G., Voss, S., Hokamp, N. G., Hellmich, M., Krug, B., Maintz, D. C., & Borggrefe, J. (2017) · Journal of Clinical Densitometry · doi:10.1016/j.jocd.2017.10.001 · Cited by 19
Three Dimensional Evaluation of Posterior Pole and Optic Nerve Head in Tilted Disc
Kim, Y. C., Moon, J.-S., Park, H.-Y. L., & Park, C. K. (2018) · Scientific Reports · doi:10.1038/s41598-018-19242-z · Cited by 19
Test-retest reliability of smile tasks using three-dimensional facial topography
Tanikawa, C., & Takada, K. (2018) · The Angle Orthodontist · doi:10.2319/062617-425.1 · Cited by 20
Sun, X.-M., Chen, G., Huang, H.-W., He, X., Yang, Y.-L., Shi, Z., Xu, M., & Jian-xin, Z. (2018) · BMC Anesthesiology · doi:10.1186/s12871-018-0488-6 · Cited by 19
Fritz, B., Bensler, S., Leunig, M., Zingg, P. O., Pfirrmann, C. W. A., & Sutter, R. (2018) · American Journal of Roentgenology · doi:10.2214/ajr.17.18882 · Cited by 19
Stoll, D., Englund, E., Hillborg, H., Vedin, S., & Larsson, A. C. (2018) · Scandinavian Journal of Trauma Resuscitation and Emergency Medicine · doi:10.1186/s13049-018-0510-5 · Cited by 19
Role of chromogenic assays in haemophilia A and B diagnosis
Bowyer, A. E., Duncan, E. M., & Antović, J. P. (2018) · Haemophilia · doi:10.1111/hae.13520 · Cited by 19
Şendur, H. N., Cındıl, E., Cerit, M. N., Demir, N. B., Şendur, A. B., & Oktar, S. Ö. (2018) · Skeletal Radiology · doi:10.1007/s00256-018-3021-6 · Cited by 19
Facial soft tissue growth in identical twins
Hersberger-Zurfluh, M. A., Papageorgiou, S. N., Motro, M., Kantarcı, A., Will, L. A., & Eliades, T. (2018) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2018.01.020 · Cited by 19
Ultralow dose CT for follow-up of solid pulmonary nodules
Paks, M., Leong, P., Einsiedel, P. F., Irving, L. B., Steinfort, D., & Pascoe, D. M. (2018) · Medicine · doi:10.1097/md.0000000000012019 · Cited by 19
Carvalho, H. N., Najafi, N., & Poelaert, J. (2019) · Pediatric Anesthesia · doi:10.1111/pan.13653 · Cited by 19
Hand Preference and Performance in Basketball Tasks
Gualdi‐Russo, E., Rinaldo, N., Pasini, A., & Zaccagni, L. (2019) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph16224336 · Cited by 19
Autonomous FEs (AFE) - A stride toward personalized medicine
Yosibash, Z., Myers, K. W., Trabelsi, N., & Sternheim, A. (2020) · Computers & Mathematics with Applications · doi:10.1016/j.camwa.2020.03.012 · Cited by 20
Measurement and Prediction of Railway Noise Case Study from Slovakia
Němec, M., Danihelová, A., Gergeľ, T., Gejdoš, M., Ondrejka, V., & Danihelová, Z. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17103616 · Cited by 19
Peixoto, A. B., Bravo‐Valenzuela, N. J., Martins, W. P., Tonni, G., Mattar, R., Moron, A. F., Pares, D. B. S., & Júnior, E. A. (2020) · Journal of Perinatal Medicine · doi:10.1515/jpm-2020-0002 · Cited by 22
TaqMan RT-PCR and VERSANT® HIV-1 RNA 3.0 (bDNA) assay
Israel-Ballard, K. A., Ziermann, R., Leutenegger, C. M., Canzio, J. D., Leung, K., Strom, L., Abrams, B. F., & Chantry, C. J. (2005) · Journal of Clinical Virology · doi:10.1016/j.jcv.2005.02.013 · Cited by 19
Statistical applications in dental anthropology
Harris, E. F. (2008) · Cambridge University Press eBooks · doi:10.1017/cbo9780511542442.003 · Cited by 29
Can Radiographs Predict the Use of Modular Stems in Developmental Dysplasia of the Hip?
Peters, C. L., Chrastil, J., Stoddard, G. J., Erickson, J. A., Anderson, M. B., & Pelt, C. E. (2015) · Clinical Orthopaedics and Related Research · doi:10.1007/s11999-015-4458-8 · Cited by 19
Overnight Titration of Human Respiratory Syncytial Virus Using Quantitative Shell Vial Amplification
Domachowske, J. B., & Bonville, C. A. (1998) · BioTechniques · doi:10.2144/98254dt01 · Cited by 19
Aebischer, N., Meuli, R. A., Jeanrenaud, X., Koerfer, J., & Kappenberger, L. (1998) · International journal of cardiac imaging · doi:10.1023/a:1006055512362 · Cited by 19
Rosborough, T. K. (1998) · Pharmacotherapy The Journal of Human Pharmacology and Drug Therapy · doi:10.1002/j.1875-9114.1998.tb03140.x · Cited by 19
Bentur, L., Beck, R., Elias, N., Barak, A., Efrati, O., Yahav, Y., & Vilozni, D. (2005) · BMC Pediatrics · doi:10.1186/1471-2431-5-19 · Cited by 19
Haghi, D., Süselbeck, T., Fluechter, S., Kalmár, G., Schröder, M., Kaden, J. J., Poerner, T. C., Borggrefe, M. M., & Papavassiliu, T. (2006) · Clinical Research in Cardiology · doi:10.1007/s00392-006-0355-1 · Cited by 19
Enumeration of Absolute Cell Counts Using Immunophenotypic Techniques
Mandy, F., & Brando, B. (2000) · Current Protocols in Cytometry · doi:10.1002/0471142956.cy0608s13 · Cited by 19
Validation of the doubly labeled water method in rats during isolation and simulated weightlessness
Blanc, S., Géloën, A., Pachiaudi, C., Gharib, C., & Normand, S. (2000) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.2000.279.6.r1964 · Cited by 24
Hill, A. M., Pramanik, S., & McGregor, A. H. (2005) · Isokinetics and Exercise Science · doi:10.3233/ies-2005-0203 · Cited by 19
Standerholen, F. B., Myromslien, F. D., Kommisrud, E., Ropstad, E., & Waterhouse, K. E. (2014) · Cytometry Part A · doi:10.1002/cyto.a.22474 · Cited by 19
Inter-observer agreement in clinical optic disc measurement using a modified 60 D lens
Haslett, R. S., Batterbury, M., Cuypers, M. H. M., & Cooper, R. L. (1997) · Eye · doi:10.1038/eye.1997.179 · Cited by 19
Clinical Assessment of a Nasal Decongestion Test by Visual Analog Scale in Allergic Rhinitis
Ciprandi, G., Klersy, C., Ameli, F., & Cirillo, I. (2008) · American Journal of Rhinology · doi:10.2500/ajr.2008.22.3214 · Cited by 19
Evaluation of a new module in the continuous monitoring of respiratory mechanics
Nunes, S. L., & Takala, J. A. (2000) · Intensive Care Medicine · doi:10.1007/s001340051231 · Cited by 19
Experimental evaluation of online optical coherence pachymetry for corneal refractive surgery
Wirbelauer, C., Aurich, H., Jaroszewski, J., Hartmann, C. J., & Pham, D. T. (2003) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-003-0700-2 · Cited by 19
Chhibber, A. K., Fickling, K., Kolano, J. W., & Roberts, W. A. (1997) · Anesthesia & Analgesia · doi:10.1097/00000539-199701000-00009 · Cited by 19
Tumor-infiltrating lymphocytes are a marker for microsatellite instability in colorectal carcinoma
Smyrk, T. C., Watson, P., Kaul, K., & Lynch, H. T. (2001) · Cancer · doi:10.1002/1097-0142(20010615)91:12<2417::aid-cncr1276>3.0.co;2-u · Cited by 522
Zuber, E., & Rosfors, S. (2000) · Journal of Nuclear Cardiology · doi:10.1067/mnc.2000.109776 · Cited by 19
A Simplified Method for Calculating Wall Stress in Infants and Children
Karr, S. S., & Martin, G. R. (1994) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(14)80088-6 · Cited by 19
Comparative cutoff points for adenosine monophosphate and methacholine challenge testing
Fardon, T. C., Fardon, E. J., Hodge, M. R., & Lipworth, B. J. (2004) · Annals of Allergy Asthma & Immunology · doi:10.1016/s1081-1206(10)61396-8 · Cited by 19
Bjørnstad, K., Amri, M. A., Lingamanaicker, J., Oqaili, I., & Hatle, L. K. (1996) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(96)90147-9 · Cited by 19
The effects of swaddling on oxygen saturation and respiratory rate of healthy infants in Mongolia
Gombojav, N., Pollock, J. I., Manaseki‐Holland, S., & Henderson, A. J. (2006) · Acta Paediatrica · doi:10.1111/j.1651-2227.2007.00123.x · Cited by 19
Bone mineral status in adolescent girls: effects of eating disorders and exercise
Carruth, B. R., & Skinner, J. D. (2000) · Journal of Adolescent Health · doi:10.1016/s1054-139x(99)00089-0 · Cited by 19
Snelling, J. D., Abdullah, N., Brown, G. M., King, D. M., Moskovic, E. C., & Gui, G. P. H. (2003) · European Journal of Surgical Oncology · doi:10.1016/j.ejso.2003.10.003 · Cited by 19
Xu, D. Z., Olivier, N. B., & Mukkamala, R. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.90834.2008 · Cited by 20
Oyamada, J., Toyono, M., Shimada, S., Aoki‐Okazaki, M., & Takahashi, T. (2012) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2012.03.003 · Cited by 21
Arterial blood gases during exercise: Validity of transcutaneous measurements
Planès, C., Leroy, M., Foray, E., & Raffestin, B. (2001) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.26248 · Cited by 19
Klopfenstein, B. J., Purnell, J. Q., Brandon, D. D., Isabelle, L. M., & DeBarber, A. E. (2011) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2010.12.008 · Cited by 19
Tavares, L. D. A., Neto, J. B., Jardim, J. R., Souza, G. M. D. C. E., Hlatky, M. A., & Nascimento, O. A. (2012) · Jornal Brasileiro de Pneumologia · doi:10.1590/s1806-37132012000600002 · Cited by 19
A new instrument for pain assessment in the immediate postoperative period*
Machata, A.-M., Kabon, B., Willschke, H., Fäßler, K., Gustorff, B., Marhofer, P., & Curatolo, M. (2009) · Anaesthesia · doi:10.1111/j.1365-2044.2008.05798.x · Cited by 19
Qualter, Y. M., Allen, N. M., Corcoran, J. D., & O’Donovan, D. J. (2010) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.3109/14767058.2010.484471 · Cited by 19
Summers, K. E., Davies, A. J., Matthews, J., Jenner, M., Cornelius, V. R., Amess, J. A. L., Norton, A. J., Rohatiner, A. Z. S., Fitzgibbon, J., Lister, T. A., et al. (2002) · British Journal of Haematology · doi:10.1046/j.1365-2141.2002.03641.x · Cited by 19
Mana, F., Franken, P. R., Ham, H. R., Reynaert, H., & Urbain, D. (2000) · Helicobacter · doi:10.1046/j.1523-5378.2000.00016.x · Cited by 19
Bartlett, H. E., Davies, L. N., & Eperjesi, F. (2004) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2004.00245.x · Cited by 19
Walberg, M., Gaustad, P., & Steen, H. B. (1997) · Cytometry · doi:10.1002/(sici)1097-0320(19971101)29:3<250::aid-cyto8>3.0.co;2-f · Cited by 13
Acar, P., Dulac, Y., Roux, D., Rougé, P., Duterque, D., & Aggoun, Y. (2003) · The American Journal of Cardiology · doi:10.1016/s0002-9149(02)03261-7 · Cited by 19
Measurement of transfer factor during constant exhalation.
Wilson, A. F., Hearne, J., Brenner, M., & Alfonso, R. (1994) · Thorax · doi:10.1136/thx.49.11.1121 · Cited by 19
Prediction of Body Composition From Spine and Hip Bone Densitometry
Leslie, W. D. (2009) · Journal of Clinical Densitometry · doi:10.1016/j.jocd.2009.06.002 · Cited by 21
Validity of a Heart Rate Monitor During Work in the Laboratory and on the Space Shuttle
Moore, A., Lee, S. M. C., Greenisen, M. C., & Bishop, P. A. (1997) · American Industrial Hygiene Association Journal · doi:10.1080/15428119791012829 · Cited by 19
de Greeff, A., Arora, J., Hervey, S., Liu, B., & Shennan, A. H. (2008) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e3282f3fb2e · Cited by 24
Risch, L., Saely, C. H., Neyer, U., Hoefle, G., Gouya, G., Zerlauth, M., Risch, G. M., Risch, M., & Drexel, H. (2006) · Clinica Chimica Acta · doi:10.1016/j.cca.2006.10.015 · Cited by 19
Beck, M., Kau, N., & Schlebusch, H. (2003) · Archives of Disease in Childhood Fetal & Neonatal · doi:10.1136/fn.88.4.f350-b · Cited by 19
Comparison of manual and automated ELISA methods for serum ferritin analysis
Rohner, F., Zeder, C., Zimmermann, M. B., & Hurrell, R. F. (2005) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.20077 · Cited by 19
Arterial or mixed venous lactate measurement in critically ill children. Is there a difference?
Murdoch, I., Turner, C., & Dalton, R. N. (1994) · Acta Paediatrica · doi:10.1111/j.1651-2227.1994.tb18131.x · Cited by 19
Nutritional Profiles in a Public Health Perspective: A Critical Review
Foltran, F., Verduci, E., Ghidina, M., Campoy, C., Jany, K.-D., Widhalm, K., Biasucci, G., Vögele, C., HALPERN, G. M., & Gregori, D. (2010) · Journal of International Medical Research · doi:10.1177/147323001003800202 · Cited by 23
Bioelectrical Impedance: A New Method for Measuring Post-Traumatic Swelling
King, R., Clamp, J. A., Hutchinson, J. W., & Moran, C. G. (2007) · Journal of Orthopaedic Trauma · doi:10.1097/bot.0b013e318123e88a · Cited by 21
What instruments have been used to assess the mobility of community-dwelling older adults?
Davenport, S. J., Paynter, S., & de Morton, N. A. (2008) · Physical Therapy Reviews · doi:10.1179/174328813x13789827565589 · Cited by 22
Boll, D. T., Lewin, J. S., Duerk, J. L., Smith, D., Subramanyan, K., & Merkle, E. M. (2004) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-200403000-00020 · Cited by 19
Non‐contact tonometry synchronized with cardiac rhythm and its relationship with blood pressure
Queirós, A., González‐Méijome, J. M., Fernandes, P. R. B., Jorge, J., Almeida, J. B., & Parafita, M. Á. (2006) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2006.00374.x · Cited by 19
Weingarten, M. A., Yaphe, J., Blumenthal, D., Oren, M., & Margalit, A. (2001) · Patient Education and Counseling · doi:10.1016/s0738-3991(00)00199-3 · Cited by 19
Garden, O. A., Rutgers, H. C., Sørensen, S. H., Daniels, S., Walker, D., & Batt, R. M. (1997) · Research in Veterinary Science · doi:10.1016/s0034-5288(97)90030-8 · Cited by 19
Bowles, K. M., Bloxham, D. M., Perry, D. J., & Baglin, T. P. (2006) · British Journal of Haematology · doi:10.1111/j.1365-2141.2006.06165.x · Cited by 19
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.