STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 22,701–22,800 of 47,868
Lewinson, R. T., Worobets, J. T., & Stefanyshyn, D. J. (2015) · The Knee · doi:10.1016/j.knee.2015.04.003 · Cited by 18
Feasibility and reproducibility of ShearWaveTM elastography of fetal baboon organs
Quarello, E., Lacoste, R., Mancini, J., Melot-Dusseau, S., & Gorincour, G. (2015) · Prenatal Diagnosis · doi:10.1002/pd.4655 · Cited by 18
Reproducibility of regional pulse‐wave velocity in uremic subjects
Iorio, B. R. D., Cucciniello, E., Alinei, P., & Torraca, S. (2010) · Hemodialysis International · doi:10.1111/j.1542-4758.2010.00471.x · Cited by 19
Scafoglieri, A., Provyn, S., Wallace, J. A., Louis, O., Tresignie, J., Bautmans, I., Mey, J. D., & Pieter, J. (2011) · InTech eBooks · doi:10.5772/15613 · Cited by 18
Ohmura, H., Mukai, K., Takahashi, T., MATSUI, A., Hiraga, A., & JONES, J. H. (2010) · Equine Veterinary Journal · doi:10.1111/j.2042-3306.2010.00261.x · Cited by 18
Agreement Between Doppler and Invasive Blood Pressure Monitoring in Anesthetized Dogs Weighing <5 kg
Kennedy, M. J., & Barletta, M. (2015) · Journal of the American Animal Hospital Association · doi:10.5326/jaaha-ms-6163 · Cited by 20
Candela-Toha, Á. M., Recio-Vázquez, M., Delgado-Montero, A., del Rey, J. M., Muriel, A., Liaño, F., & Tenorio, T. (2012) · PubMed · doi:10.3265/nefrologia.pre2011.oct.11102 · Cited by 18
García-Gordillo, M. Á., Cruz, B. D. P., Adsuar, J. C., Ferrera, J. M. C., Abellán‐Perpiñán, J., & Martínez, F. I. S. (2015) · PubMed · doi:10.3305/nh.2015.32.6.9765 · Cited by 22
Test-retest Reliability of GPS derived Measurements in Patients with Claudication
Gernigon, M., Fouasson‐Chailloux, A., Colas-Ribas, C., Noury-Desvaux, B., Faucheur, A. L., & Abraham, P. (2015) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2015.07.009 · Cited by 20
Bisi, M. C., Stagni, R., Caroselli, A., & Cappello, A. (2015) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2015.05.013 · Cited by 22
Predictive validity of the body adiposity index in costa rican students
Carpio‐Rivera, E., Hernández‐Elizondo, J., Salicetti‐Fonseca, A., Herrera, A. S., & Moncada‐Jiménez, J. (2015) · American Journal of Human Biology · doi:10.1002/ajhb.22800 · Cited by 22
Joneli, J., Wanzenried, U., Schiess, J., Lanz, C., Caslavska, J., & Thormann, W. (2013) · Electrophoresis · doi:10.1002/elps.201200653 · Cited by 18
Holland, A. E., Hill, K., Alison, J. A., Luxton, N., Mackey, M. G., Hill, C., & JENKINS, S. C. (2010) · Respiration · doi:10.1159/000308464 · Cited by 18
Pinero, D. P., Camps, V. J., Mateo, V., & Ruiz-Fortes, P. (2012) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2012.03.026 · Cited by 18
Cardiorespiratory measurements during field tests in CF: Use of an ambulatory monitoring system
Bradley, J. M., Kent, L., O'Neill, B. M., Nevill, A. M., Boyle, L. R., & Elborn, J. S. (2010) · Pediatric Pulmonology · doi:10.1002/ppul.21360 · Cited by 20
Ginderdeuren, F. V., Cauwelaert, K. V., & Malfroot, A. (2006) · Journal of Cystic Fibrosis · doi:10.1016/j.jcf.2006.01.007 · Cited by 20
Comparison of heart rate monitoring with indirect calorimetry for energy expenditure evaluation
Yu, Z., Völgyi, E., Wang, R., Ember, A., Wiklund, P., Alén, M., Tylavsky, F. A., & Cheng, S. (2012) · Journal of sport and health science/Journal of Sport and Health Science · doi:10.1016/j.jshs.2012.07.004 · Cited by 18
Niemann, A. K., Thrysøe, S. A., Nygaard, J. V., Hasenkam, J. M., & Petersen, S. E. (2011) · The Journal of Vascular Access · doi:10.5301/jva.2011.8440 · Cited by 18
A low-cost force sensor-based posturographic plate for home care telerehabilitation exergaming
Arpaïa, P., Cimmino, P., Matteis, E. D., & D’Addio, G. (2014) · Measurement · doi:10.1016/j.measurement.2014.01.031 · Cited by 18
Jaffrin, M. Y., & Morel, H. (2008) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-008-0394-z · Cited by 19
Scruggs, P. W., Beveridge, S. K., & Clocksin, B. D. (2005) · Measurement in Physical Education and Exercise Science · doi:10.1207/s15327841mpee0904_1 · Cited by 26
Curone, D., Secco, E. L., Caldani, L., Lanatà, A., Paradiso, R., Tognetti, A., & Magenes, G. (2012) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2011.2182615 · Cited by 21
Boehme, S., Duenges, B., Klein, K. U., Hartwich, V., Beate, M., Consiglio, J., Baumgardner, J. E., Markstaller, K., Basciani, R., & Vogt, A. P. (2013) · PLoS ONE · doi:10.1371/journal.pone.0060591 · Cited by 18
MicroRNA levels quantified in whole blood varies from PBMCs
Atarod, S., Smith, H., Dickinson, A. M., & Wang, X. (2015) · F1000Research · doi:10.12688/f1000research.4884.4 · Cited by 18
Jeong, J. S., Kang, M. G., Kim, C. Y., & Kim, N. R. (2015) · Journal of Glaucoma · doi:10.1097/ijg.0000000000000231 · Cited by 18
Li, A. C., Tereszkowski, C. M., Edwards, A. M., Simpson, J. A. R., & Buchholz, A. C. (2010) · Journal of the American College of Nutrition · doi:10.1080/07315724.2010.10719837 · Cited by 19
Jetha, M. M., Nzekwu, U., Lewanczuk, R. Z., & Ball, G. D. C. (2009) · Journal of Pediatric Endocrinology and Metabolism · doi:10.1515/jpem.2009.22.11.1051 · Cited by 19
López‐Herce, J., Rupérez, M., Sánchez, C., García, C., & García, E. (2006) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-006-2229-5 · Cited by 18
Miloš, M., Herak, D. C., & Zadro, R. (2008) · International Journal of Laboratory Hematology · doi:10.1111/j.1751-553x.2008.01111.x · Cited by 18
Criswell, K. A., Bock, J. H., Wildeboer, S. E., Johnson, K., & Giovanelli, R. P. (2014) · Veterinary Clinical Pathology · doi:10.1111/vcp.12132 · Cited by 18
Owens, R. L., HESS, D. R., Malhotra, A., Venegas, J. G., & Harris, R. S. (2008) · Critical Care Medicine · doi:10.1097/ccm.0b013e318186afcb · Cited by 18
Validation of the SenseWear Armband in different ambient temperatures
Hoye, K. V., Boen, F., & Lefevre, J. (2014) · Journal of Sports Sciences · doi:10.1080/02640414.2014.981846 · Cited by 20
Exercise aortic stiffness: reproducibility and relation to end-organ damage in men
Keith, L. J., Rattigan, S., Keske, M. A., Jose, M., & Sharman, J. E. (2013) · Journal of Human Hypertension · doi:10.1038/jhh.2013.5 · Cited by 18
A New Technique for Radiographic Measurement of Acetabular Cup Orientation
Derbyshire, B., Diggle, P. J., Ingham, C. J., Macnair, R., Wimhurst, J. A., & Jones, H. W. (2013) · The Journal of Arthroplasty · doi:10.1016/j.arth.2013.06.024 · Cited by 18
Functional gait assessment: Reliability and validity in people with peripheral vestibular disorders
Nilsagård, Y. E., Kollén, L., Axelsson, H., Bjerlemo, B., & Forsberg, A. (2014) · International Journal of Therapy and Rehabilitation · doi:10.12968/ijtr.2014.21.8.367 · Cited by 18
Visual search, movement behaviour and boat control during the windward mark rounding in sailing
Pluijms, J. P., Cañal‐Bruland, R., Hoozemans, M. J. M., & Savelsbergh, G. J. P. (2014) · Journal of Sports Sciences · doi:10.1080/02640414.2014.946075 · Cited by 22
Madsen, O. R., Hansen, L. B., Rytter, A., Suetta, C., & Egsmose, C. (2008) · Clinical Rheumatology · doi:10.1007/s10067-008-0978-x · Cited by 18
Weijenborg, P. T. M., ter Kuile, M. M., & Jansen, F. W. (2006) · Fertility and Sterility · doi:10.1016/j.fertnstert.2006.06.052 · Cited by 19
Bernstein, D. P., Henry, I., Lemmens, H. J. M., Chaltas, J. L., DeMaria, A. N., Moon, J., & Kahn, A. M. (2015) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-015-9668-9 · Cited by 19
Canfrán, S., Cediel, R., Sández, I., Caro‐Vadillo, A., & de Segura, I. Á. G. (2015) · Journal of Small Animal Practice · doi:10.1111/jsap.12362 · Cited by 18
Renkawitz, T. F., Sendtner, E., Schuster, T., Weber, M., Grifka, J. K., & Woerner, M. L. (2013) · The Journal of Arthroplasty · doi:10.1016/j.arth.2013.09.034 · Cited by 18
Rodgers, J. D., Lawes, J. R., Vidal, A. B., Ellis‐Iversen, J., Ridley, A., Pleydell, E. J., Powell, L. F., Toszeghy, M., Stapleton, K., & Clifton-Hadley, F. A. (2012) · Veterinary Microbiology · doi:10.1016/j.vetmic.2012.04.011 · Cited by 18
Body Composition and Basal Metabolic Rate in Women with Type 2 Diabetes Mellitus
Ferreira, M. D. F., Ribeiro, F. D., Coelho, G. M. D. O., Barros, M. E., Lanzillotti, R. S., Neto, J. F. N., Portella, E. S., Lanzillotti, H. S., & Soares, E. D. A. (2014) · Journal of Nutrition and Metabolism · doi:10.1155/2014/574057 · Cited by 21
Transperineal versus transvaginal ultrasound cervical length measurement and preterm labor
Gauthier, T., Marin, B., Garuchet-Bigot, A., Kanoun, D., Catalan, C., Caly, H., Eyraud, J., & Aubard, Y. (2014) · Archives of Gynecology and Obstetrics · doi:10.1007/s00404-014-3229-1 · Cited by 19
Measurement of cardiac troponin I utilizing a point of care analyzer in healthy alpacas
Blass, K. A., Kraus, M. S., Rishniw, M., Mann, S., Mitchell, L. M., & Divers, T. J. (2011) · Journal of Veterinary Cardiology · doi:10.1016/j.jvc.2011.08.002 · Cited by 18
Hresko, M. T., Mesiha, M., Richards, K., & Zurakowski, D. (2006) · Journal of Pediatric Orthopaedics · doi:10.1097/01.bpo.0000242432.73563.63 · Cited by 18
Peeters, M., & Claessens, A. (2010) · Journal of Sports Sciences · doi:10.1080/02640414.2010.530677 · Cited by 21
Burdick, S., Mitchell, M. A., Neil, J., Heggem, B., Whittington, J. K., & Acierno, M. J. (2012) · Journal of the American Veterinary Medical Association · doi:10.2460/javma.240.5.596 · Cited by 22
The influence of elbow joint kinematics on wrist speed in cricket fast bowling
Middleton, K. J., Alderson, J. A., Elliott, B. C., & Mills, P. (2015) · Journal of Sports Sciences · doi:10.1080/02640414.2014.1003586 · Cited by 20
Täng, M. S., Redfors, B., Lindbom, M., Svensson, J., Råmunddal, T., Ohlsson, C., Shao, Y., & Ömerovic, E. (2012) · Growth Hormone & IGF Research · doi:10.1016/j.ghir.2012.09.002 · Cited by 18
de Aguiar, O. B., da Fonseca, M. D. J. M., & Valente, J. G. (2010) · Revista Brasileira de Epidemiologia · doi:10.1590/s1415-790x2010000200004 · Cited by 18
Nasreddine, L., Naja, F., Hills, A. P., Youssef, S. K., Chahine, J., & Hwalla, N. C. (2011) · Clinical Nutrition · doi:10.1016/j.clnu.2011.11.008 · Cited by 18
Jeong, Y. B., Kim, T. H., Roh, Y. J., Choi, I. C., & Suh, J. H. (2010) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2010.02.006 · Cited by 18
Talsma, E. F., Verhoef, H., Brouwer, I. D., Wagt, A. S. M.-D., Hulshof, P. J. M., & Melse‐Boonstra, A. (2015) · BMC Medicine · doi:10.1186/s12916-014-0256-5 · Cited by 19
Can we use portable nitric oxide analyzer in young children?
Kalliola, S., Malmberg, P., Rito, T., Pelkonen, A. S., & Mäkelä, M. J. (2011) · Pediatric Pulmonology · doi:10.1002/ppul.21390 · Cited by 19
Kawalilak, C., Johnston, J., Olszynski, W., Leswick, D. A., & Kontulainen, S. (2014) · Journal of clinical densitometry · doi:10.1016/j.jocd.2013.09.014 · Cited by 17
Suitability of methylmalonic acid and total homocysteine analysis in dried bloodspots
der Velden, M. G. M. D. S., van der Ham, M., Jans, J. J. M., Visser, G., van Hasselt, P. M., Prinsen, H. C. M. T., & Verhoeven‐Duif, N. M. (2014) · Analytica Chimica Acta · doi:10.1016/j.aca.2014.10.043 · Cited by 19
Time Course of Endotoxin-Induced Airways’ Inflammation in Healthy Subjects
Doyen, V., Kassengera, Z., Dinh, D. H. P., & Michel, O. (2011) · Inflammation · doi:10.1007/s10753-010-9286-0 · Cited by 18
Thomas, V., Costes, F., Chatagnon, M., Pouilly, J.-P., & Busso, T. (2008) · Journal of Sports Sciences · doi:10.1080/02640410802104920 · Cited by 22
Quantitative Assessment of Lung Using Hyperpolarized Magnetic Resonance Imaging
Emami, K., Stephen, M., Kadlecek, S. J., Cadman, R. V., Ishii, M., & Rizi, R. R. (2009) · Proceedings of the American Thoracic Society · doi:10.1513/pats.200902-008aw · Cited by 20
Validation of a User-Friendly and Rapid Method for Quantifying Iodine Content of Salt
Rohner, F., Garrett, G. S., Laillou, A., Frey, S. K., Mothes, R., Schweigert�, F. J., & Locatelli-Rossi, L. (2012) · Food and Nutrition Bulletin · doi:10.1177/15648265120334s309 · Cited by 20
Pauls, S., Kürschner, C., Dharaiya, E., Muche, R., Schmidt, S. A., Krüger, S., Brambs, H., & Aschoff, A. J. (2007) · European Journal of Radiology · doi:10.1016/j.ejrad.2007.05.022 · Cited by 18
Endoscopic Estimation of Tumor Size in Early Gastric Cancer
Choi, J., Kim, S. G., Im, J. P., Kim, J. S., & Jung, H. C. (2013) · Digestive Diseases and Sciences · doi:10.1007/s10620-013-2644-7 · Cited by 18
Martin, J. S., Borges, A. R., Christy, J. B., & Beck, D. T. (2015) · Hypertension Research · doi:10.1038/hr.2015.36 · Cited by 19
Tsikas, D. (2008) · Current Opinion in Clinical Nutrition & Metabolic Care · doi:10.1097/mco.0b013e3283065bb1 · Cited by 18
The Dyssynchrony in Predicting Response to Cardiac Resynchronization Therapy: A Call for Change
Fornwalt, B. K. (2011) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2010.12.015 · Cited by 18
Acher, P. L., Puttagunta, S. A., Rhode, K., Morris, S. L., Kinsella, N., Gaya, A. M., Prokar Dasgupta, A., Deehan, C., Beaney, R. P., Popert, R., et al. (2010) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2010.06.003 · Cited by 18
Hettema, J. E., Hosseinbor, S., & Ingersoll, K. S. (2012) · HIV Clinical Trials · doi:10.1310/hct1305-271 · Cited by 18
Okada, T., Kawahito, S., Mita, N., Matsuhisa, M., Kitahata, H., Shimada, M., & Oshita, S. (2013) · The Journal of Medical Investigation · doi:10.2152/jmi.60.205 · Cited by 18
How reliable are crop production data? Case studies in USA and Argentina
Sadras, V. O., Grassini, P., Costa, R., Cohan, L., & Hall, A. J. (2014) · Food Security · doi:10.1007/s12571-014-0361-5 · Cited by 24
Wagner, M., Schilling, R. L., Doeblin, P., Huppertz, A., Luhur, R., Schwenke, C., Maurer, M. H., Hamm, B., Taupitz, M., & Durmus, T. (2012) · European Radiology · doi:10.1007/s00330-012-2563-6 · Cited by 18
Baker, S. T., Strauss, B. J., Prendergast, L. A., Panagiotopoulos, S., Thomas, G. E., Vu, T. D. T., Proietto, J., & Jerums, G. (2012) · European Journal of Clinical Nutrition · doi:10.1038/ejcn.2012.3 · Cited by 20
Effect of Orthotopic Liver Transplantation (OLT) on Branched-Chain Amino Acid Requirement
Mager, D. R., Wykes, L., Roberts, E. A., Ball, R. O., & Pencharz, P. B. (2006) · Pediatric Research · doi:10.1203/01.pdr.0000219302.21321.87 · Cited by 19
Colquhoun, D. A., & Roche, A. M. (2014) · Best practice & research. Clinical anaesthesiology · doi:10.1016/j.bpa.2014.09.007 · Cited by 19
Williamson, T. H., Ugarte, M., Shunmugam, M., & Laidlaw, D. H. (2013) · Indian Journal of Ophthalmology · doi:10.4103/0301-4738.117804 · Cited by 18
Evaluation of an algorithm for arterial lumen diameter measurements by means of ultrasound
Cinthio, M., Jansson, T. T., Eriksson, A., Ahlgren, Å. R., Persson, H. W., & Lindström, K. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0660-8 · Cited by 18
Wickert, M., John, M. T., Schierz, O., Hirsch, C., Aarabi, G., & Reissmann, D. R. (2013) · European Journal Of Oral Sciences · doi:10.1111/eos.12104 · Cited by 24
Domalpally, A., Gangaputra, S. S., Peng, Q., & Danis, R. P. (2010) · Ophthalmic surgery, lasers & imaging retina · doi:10.3928/15428877-20100325-01 · Cited by 18
The reliability and validity of the Everyday Feelings Questionnaire in a clinical population
Mann, J., Henley, W., O’Mahen, H., & Ford, T. J. (2012) · Journal of Affective Disorders · doi:10.1016/j.jad.2012.03.045 · Cited by 20
Prakash, A., Garg, R., Marcus, E. N., Reynolds, G., Geva, T., & Powell, A. J. (2006) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20654 · Cited by 18
The cuff method: a pilot study of a new method of monitoring neuromuscular function
Rodiera, J., Serradell, A., Álvarez‐Gómez, J. A., & Aliaga, L. (2005) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2005.00777.x · Cited by 18
Lund, H., Snilsberg, A. H., Halvorsen, T. G., Hemmersbach, P., & Reubsaet, L. (2013) · Bioanalysis · doi:10.4155/bio.13.8 · Cited by 18
Can the Acetabular Position be Derived from a Pelvic Frame of Reference?
Dandachli, W., Nakhla, A., Iranpour, F. G., Kannan, V., & Cobb, J. P. (2008) · Clinical Orthopaedics and Related Research · doi:10.1007/s11999-008-0336-y · Cited by 19
The Value of Assessing Myocardial Deformation at Recovery after Dobutamine Stress Echocardiography
Hwang, H., Lee, H., Yang, I., Lee, J. L., Pak, H. Y., Park, C., Jin, E., Cho, J., Kim, C., & Sohn, I. S. (2014) · Journal of Cardiovascular Ultrasound · doi:10.4250/jcu.2014.22.3.127 · Cited by 18
Łuczyński, W., Fendler, W. M., Ramatowska, A., Szypowska, A., Szadkowska, A., Mlynarski, W. M., Chumięcki, M., Jarosz-Chobot, P. A., Chrzanowska, J. A., Noczyńska, A., et al. (2014) · International Journal of Endocrinology · doi:10.1155/2014/630712 · Cited by 18
Yamashita, S., Kawase, R., Nakaoka, H., Nakatani, K., Inagaki, M., Yuasa‐Kawase, M., Tsubakio‐Yamamoto, K., Sandoval, J. C., Masuda, D., Ohama, T., et al. (2009) · Clinica Chimica Acta · doi:10.1016/j.cca.2009.09.010 · Cited by 18
León-Luis, J. A. D., Ruiz, Y., Gamez, F., Pintado, P., Oyelese, Y., Pereda, A. C., Ortiz-Quintana, L., & Santolaya-Forgas, J. (2011) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22547 · Cited by 18
Simões, J. F. F. L., Jesus, L. M. T., Voegeli, D., Sá‐Couto, P., Fernandes, J., & Morgado, M. (2011) · Journal of Advanced Nursing · doi:10.1111/j.1365-2648.2010.05559.x · Cited by 23
Reference values and repeatability of buccal mucosal bleeding time in healthy sedated cats
Alatzas, D. G., Mylonakis, M. E., Kazakos, G. M., Kostoulas, P., Kritsepi‐Konstantinou, M., & Polizopoulou, Z. S. (2013) · Journal of Feline Medicine and Surgery · doi:10.1177/1098612x13502973 · Cited by 18
Cross-Validation of Field-Based Assessments of Body Composition for Individuals with Down Syndrome
Usera, P. C., Foley, J. T., & Yun, J. (2005) · Adapted Physical Activity Quarterly · doi:10.1123/apaq.22.2.198 · Cited by 18
Point of Care D-Dimer Testing in the Emergency Department: A Bioequivalence Study
Perveen, S., Unwin, D., & Shetty, A. (2012) · Annals of Laboratory Medicine · doi:10.3343/alm.2013.33.1.34 · Cited by 18
Inter-observer agreement according to malaria parasite density
Billo, M., Diakité, M., Dolo, A., Diallo, M., Poudiougou, B., Diawara, S. I., Johnson, E. S., Rice, J. C., Krogstad, D. J., & Doumbo, O. K. (2013) · Malaria Journal · doi:10.1186/1475-2875-12-335 · Cited by 19
van den Bogaart, E., Schoone, G. J., Adams, E. R., & Schallig, H. D. F. H. (2013) · International Journal for Parasitology Drugs and Drug Resistance · doi:10.1016/j.ijpddr.2013.11.001 · Cited by 18
Measuring echogenicity and area of the puborectalis muscle: method and reliability
Grob, A. T. M., Veen, A., Schweitzer, K. J., Withagen, M. I. J., van Veelen, G. A., & van der Vaart, C. H. (2014) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.13409 · Cited by 18
Hiremath, G. S., Olivé, A., Shah, S. D., Davis, C. M., Shulman, R. J., & Devaraj, S. (2014) · Annals of Allergy Asthma & Immunology · doi:10.1016/j.anai.2014.09.012 · Cited by 19
Maribo, T., Iversen, E., Andersen, N. T., Stengaard‐Pedersen, K., & Schiøttz‐Christensen, B. (2009) · International Musculoskeletal Medicine · doi:10.1179/175361409x12472218841040 · Cited by 21
Maréchaux, S., Goffic, C. L., Ennezat, P. V., Sémichon, M., Castel, A., Delelis, F., Lemahieu, J. M., Menet, A., Graux, P., & Tribouilloy, C. M. (2014) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jeu091 · Cited by 18
Repeatability of physiotherapy chest wall vibrations applied to spontaneously breathing adults
Shannon, H., Gregson, R. K., Stocks, J., Cole, T. J., & Main, E. (2008) · Physiotherapy · doi:10.1016/j.physio.2008.08.004 · Cited by 18
Kim, N., Lee, J., Song, Y., Kim, H. J., Yeom, J. S., & Cho, G. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22984 · Cited by 20
Real-time three-dimensional transthoracic echocardiography in daily practice: initial experience
Anwar, A. M., Nosir, Y. F. M., Zainal-Abidin, S. K., Ajam, A., & Chamsi‐Pasha, H. (2012) · Cardiovascular Ultrasound · doi:10.1186/1476-7120-10-14 · Cited by 18
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.