STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 27,101–27,200 of 47,868
Kouwijzer, I., Cowan, R. E., MAHER, J. L., Groot, F. P., Riedstra, F., Valent, L., van der Woude, L. H. V., & de Groot, S. (2019) · Spinal Cord · doi:10.1038/s41393-019-0262-8 · Cited by 16
Mustafy, T., Londoño, I., & Villemure, I. (2019) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2019.03.009 · Cited by 16
Investigating the Feasibility of Automatic Assessment of Programming Tasks
Liebenberg, J., & Pieterse, V. (2018) · Journal of Information Technology Education Innovations in Practice · doi:10.28945/4150 · Cited by 13
Marcano-Olivier, M., Erjavec, M., Horne, P. J., Viktor, S., & Pearson, R. (2019) · Public Health Nutrition · doi:10.1017/s136898001900048x · Cited by 17
Freedland, K. E., Steinmeyer, B. C., Carney, R. M., Rubin, E. H., & Rich, M. W. (2019) · Health Psychology · doi:10.1037/hea0000682 · Cited by 16
Differential visual acuity – A new approach to measuring visual acuity
Leat, S. J., Yakobchuk‐Stanger, C., & Irving, E. L. (2019) · Journal of Optometry · doi:10.1016/j.optom.2019.04.002 · Cited by 13
Arnold, J. J., Sims, D., Gill, P. S., Cockwell, P., & Ferro, C. J. (2019) · Clinical Kidney Journal · doi:10.1093/ckj/sfz049 · Cited by 14
Uçal, Y., Coşkun, A., & Özpınar, A. (2019) · Expert Review of Proteomics · doi:10.1080/14789450.2019.1624165 · Cited by 15
Fujiwara, A., Murakami, K., & Sasaki, S. (2019) · Journal of Epidemiology · doi:10.2188/jea.je20190026 · Cited by 14
Corneal Curvature: the Influence of Corneal Accommodation and Biomechanics on Corneal Shape
Wallace, H. B., McKelvie, J., Green, C. R., & Misra, S. L. (2019) · Translational Vision Science & Technology · doi:10.1167/tvst.8.4.5 · Cited by 13
Elmenhorst, J., Weberruß, H., Mayr, M., Pfister, K., & Oberhoffer, R. (2019) · Frontiers in Pediatrics · doi:10.3389/fped.2019.00334 · Cited by 13
Otim, O. (2019) · Environmental Science Processes & Impacts · doi:10.1039/c9em00288j · Cited by 13
Wang, J., Zhang, L., Li, X., Zhang, X., & Yu, H. (2019) · RSC Advances · doi:10.1039/c9ra04014e · Cited by 13
Molero-Senosiaín, M., Morales‐Fernández, L., Saenz-Frances, F., Garcia-Sanchez, J., & Martínez-de-la-Casa, J. M. (2019) · European Journal of Ophthalmology · doi:10.1177/1120672119878017 · Cited by 13
Rankin, A. J., Allwood‐Spiers, S., Lee, M. M. Y., Zhu, L. Y., Woodward, R. A., Kuehn, B., Radjenovic, A., Sattar, N. A., Roditi, G., Mark, P. B., et al. (2019) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-019-00809-4 · Cited by 13
Heimer, J., Gascho, D., Madea, B., Steuer, A. E., Martinez, R. M., Thali, M. J., & Zoelch, N. (2020) · International Journal of Legal Medicine · doi:10.1007/s00414-019-02235-6 · Cited by 14
Measuring Infant Visual Acuity with Gaze Tracker Monitored Visual Fixation
Hathibelagal, A. R., Leat, S. J., Irving, E. L., Nandakumar, K., & Eizenman, M. (2015) · Optometry and Vision Science · doi:10.1097/opx.0000000000000613 · Cited by 13
Nuvolone, D., Petri, D., Biggeri, A., Barbone, F., & Voller, F. (2020) · International Archives of Occupational and Environmental Health · doi:10.1007/s00420-020-01522-9 · Cited by 14
Evaluation of the HemoCue WBC DIFF in leukopenic patient samples
Kur, D. K., Agersnap, N., Holländer, N. H., Pedersen, O. B., & Friis-Hansen, L. J. (2020) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.13158 · Cited by 14
Shalom, E., Hirshtal, E., Slotki, I. N., Shavit, L., Yitzhaky, Y., Engelberg, S., & Nitzan, M. (2020) · Physiological Measurement · doi:10.1088/1361-6579/ab7b41 · Cited by 13
COMPARISON OF THREE DIFFERENT MEASUREMENT SYSTEMS TO ASSESS THE VERTICAL JUMP HEIGHT
Heredia‐Jimenez, J., & Orantes-González, E. (2020) · Revista Brasileira de Medicina do Esporte · doi:10.1590/1517-869220202602185305 · Cited by 13
Initial experience in self-monitoring of intraocular pressure
McGarva, E., Farr, J., Dabasia, P. L., Lawrenson, J. G., & Murdoch, I. (2020) · European Journal of Ophthalmology · doi:10.1177/1120672120920217 · Cited by 13
Nathan, A. S., Xiang, Q., WOJDYLA, D. M., Khatana, S. A. M., Dayoub, E. J., Wadhera, R. K., Bhatt, D. L., Kolansky, D. M., Kirtane, A. J., Rao, S. V., et al. (2020) · JAMA Cardiology · doi:10.1001/jamacardio.2020.0753 · Cited by 13
Fleischmann, R., Köhn, A., Tränkner, S., Brandt, S. A., & Schmidt, S. H. (2020) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2020.00174 · Cited by 13
Hernando, R., Fernández‐Marchena, J. L., Willman, J. C., Ollé, A., Vergès, J. M., & Lozano, M. (2020) · Quaternary International · doi:10.1016/j.quaint.2020.05.022 · Cited by 13
Can We Trust Inertial and Heart Rate Sensor Data from an APPLE Watch Device?
Espinosa, H. G., Thiel, D. V., Sorell, M., & Rowlands, D. D. (2020) · Conference of the International Sports Engineering Association (ISEA) · doi:10.3390/proceedings2020049128 · Cited by 13
Combret, Y., Médrinal, C., Bonnevie, T., Gravier, F., Roux, P. L., Lamia, B., Prieur, G., & Reychler, G. (2020) · Journal of Cystic Fibrosis · doi:10.1016/j.jcf.2020.05.014 · Cited by 14
Reliability and Validity of a Novel Wearable Device for Measuring Elbow Strength
Brookshaw, M., Sexton, A., & McGibbon, C. A. (2020) · Sensors · doi:10.3390/s20123412 · Cited by 13
Telleria-Aramburu, N., Alegría-Lertxundi, I., & Arroyo‐Izaga, M. (2020) · Public Health Nutrition · doi:10.1017/s1368980020001822 · Cited by 15
Schuler, S., Petersen, C. L., West, N., Ansermino, J. M., Merchant, R. N., & Görges, M. (2020) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-020-00565-0 · Cited by 16
Hanley, B., Bissas, A., & Merlino, S. (2020) · Frontiers in Sports and Active Living · doi:10.3389/fspor.2020.00102 · Cited by 13
Miranda, W. R., Jain, C. C., Connolly, H. M., DuBrock, H. M., Cetta, F., Egbe, A. C., & Hagler, D. J. (2020) · Heart · doi:10.1136/heartjnl-2020-317111 · Cited by 13
Limitations of surface EMG estimate of parasternal intercostal to infer neural respiratory drive
Tagliabue, G., Ji, M., Jagers, J. S., Lee, W. S., Dean, D., Zuege, D. J., Wilde, E. R., & Easton, P. A. (2020) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2020.103572 · Cited by 13
Huang, J., Zhu, Y., Ma, W., Zhang, Z., Shi, W., & Lin, J. (2020) · JBJS Open Access · doi:10.2106/jbjs.oa.20.00078 · Cited by 13
Hernández‐Belmonte, A., Buendía‐Romero, Á., Martínez-Cava, A., Courel‐Ibáñez, J., Mora‐Rodríguez, R., & Pallarés, J. G. (2020) · Applied Sciences · doi:10.3390/app10228002 · Cited by 13
Chen, K., Lee, Y., Yu, T., Cheng, L.-J., Chao, C.-Y., & Hsieh, C. (2021) · BMC Psychiatry · doi:10.1186/s12888-021-03041-4 · Cited by 14
Nutrition Evaluation Screening Tool: An Easy to Use Screening Tool for Hospitalised Children
Dokal, K., Asmar, N., Shergill-Bonner, R., & Mutalib, M. (2021) · Pediatric Gastroenterology Hepatology & Nutrition · doi:10.5223/pghn.2021.24.1.90 · Cited by 14
Arrufat‐Pié, E., Estévez‐Báez, M., Estévez‐Carreras, J. M., Curbelo, C. M., Leisman, G., & Beltrán, C. (2021) · Engineering Reports · doi:10.1002/eng2.12367 · Cited by 13
Meropenem Stability in Human Plasma at −20 °C: Detailed Assessment of Degradation
Gijsen, M., Filtjens, B., Annaert, P., Armoudjian, Y., Debaveye, Y. A., Wauters, J., Slaets, P., & Spriet, I. (2021) · Antibiotics · doi:10.3390/antibiotics10040449 · Cited by 13
Drennan, P. G., Thoma, Y., Barry, L., Matthey, J., Sivam, S., & van Hal, S. J. (2021) · Therapeutic Drug Monitoring · doi:10.1097/ftd.0000000000000900 · Cited by 13
María Mónica Marín, O., Ángel Alberto García, P., Múñoz, Ó., Julio César Castellanos, R., Cáceres-Méndez, E. A., & Santacruz-Pacheco, D. (2021) · Heart Rhythm O2 · doi:10.1016/j.hroo.2021.06.005 · Cited by 14
Kamya, L., Hansson, E., Weick, L., & Hansson, E. (2021) · Health and Quality of Life Outcomes · doi:10.1186/s12955-021-01812-x · Cited by 13
Hassan, A. T., Ahmed, S. M., Abdelhaffez, A., & Mohamed, S. A. A. (2021) · Multidisciplinary Respiratory Medicine · doi:10.4081/mrm.2021.742 · Cited by 14
Hobson‐Webb, L. D., Zwelling, P. J., Raja, S. M., Pifer, A. N., & Kishnani, P. S. (2021) · Molecular Genetics and Metabolism Reports · doi:10.1016/j.ymgmr.2021.100785 · Cited by 17
Deviandri, R., van der Veen, H. C., Lubis, A. M. T., Postma, M. J., & van den Akker‐Scheek, I. (2021) · Orthopaedic Journal of Sports Medicine · doi:10.1177/23259671211038372 · Cited by 13
O’Brien, D. M., Sági‐Kiss, V., Palma-Duran, S. A., Cunningham, C., Barrett, B., Johnston, C. S., Midthune, D., Kipnis, V., Freedman, L. S., & Tasevska, N. (2022) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/nqac004 · Cited by 14
Comparison of Techniques for Tracking Body Composition Changes Across a Basketball Season
Ploudre, A., & Mayhew, J. L. (2018) · International journal of exercise science · doi:10.70252/oxvm9894 · Cited by 13
Coquart, J. B., Eston, R. G., Noakes, T. D., Tourny, C., L’Hermette, M., Lemaître, F., & Garcin, M. (2012) · Sports Medicine · doi:10.1007/bf03262298 · Cited by 13
Molloi, S. Y., Ding, H. J., & Feig, S. A. (2015) · Academic Radiology · doi:10.1016/j.acra.2015.03.017 · Cited by 13
Non-Invasive Determination of Cardiac Output in Pre-Capillary Pulmonary Hypertension
Lador, F., Hervé, P., Bringard, A., Günther, S., Garcia, G., Savale, L., Ferretti, G., Soccal, P. M., Chemla, D., Humbert, M. J. C., et al. (2015) · PLoS ONE · doi:10.1371/journal.pone.0134221 · Cited by 13
Mosing, M., Staub, L., & Moens, Y. P. (2010) · Veterinary Anaesthesia and Analgesia · doi:10.1111/j.1467-2995.2010.00548.x · Cited by 13
3D ultrasonography is as accurate as low-dose CT in thyroid volumetry
Licht, K., Darr, A., Opfermann, T., Winkens, T., & Freesmeyer, M. G. (2013) · Nuklearmedizin - NuclearMedicine · doi:10.3413/nukmed-0615-13-08 · Cited by 13
[Validity of an equation based on anthropometry to estimate body fat in older adults].
Huerta, R., Esparza‐Romero, J., Urquidez, R., Pacheco, B. I., Valencia, M. E., & Alemán-Mateo, H. (2007) · PubMed · Cited by 15
O'Byrne, M. L., Glatz, A. C., Goldberg, D., Shinohara, R. T., Dori, Y., Rome, J. J., & Gillespie, M. J. (2014) · Congenital Heart Disease · doi:10.1111/chd.12226 · Cited by 13
Macedo, C. D. S. G., de Souza, P. R., Alves, P. M., & Cardoso, J. R. (2009) · Fisioterapia e Pesquisa · doi:10.1590/s1809-29502009000300008 · Cited by 13
LATTES, S., Appert‐Flory, A., Fischer, F., Jambou, D., & Toulon, P. A. (2010) · Haemophilia · doi:10.1111/j.1365-2516.2010.02361.x · Cited by 13
van den Heuvel, E. G. H. M., Muys, T., Pellegrom, H., Bruyntjes, J. P., Dokkum, W. V., Spanhaak, S., & Schaafsma, G. (1998) · Clinical Chemistry · doi:10.1093/clinchem/44.3.649 · Cited by 13
Letter, J. D., Sie, T. H., Moll, F. L., Algra, A., Eikelboom, B. C., & Ackerstaff, R. G. A. (1998) · Cardiovascular Surgery · doi:10.1016/s0967-2109(98)00020-9 · Cited by 13
Ahmadi, N., Shavelle, D. M., Nabavi, V., Hajsadeghi, F., Moshrefi, S., Flores, F. R., Azmoon, S., Mao, S. S., Ebrahimi, R., & Budoff, M. J. (2010) · Journal of cardiovascular computed tomography · doi:10.1016/j.jcct.2010.01.007 · Cited by 14
Improved method for planning intramedullary guiding rod entry point in total knee arthroplasty
Xiao, J., Wang, C., Zhu, L., Li, X., Liu, T., Wang, Q., & Qin, Y. (2014) · Archives of Orthopaedic and Trauma Surgery · doi:10.1007/s00402-014-1943-6 · Cited by 13
CT Density Distribution Analysis in Patients with Cystic Fibrosis
de Lavernhe, I., Blanche, A. F. L., Dégrugilliers, L., Carette, M., & Bayat, S. (2014) · Academic Radiology · doi:10.1016/j.acra.2014.09.003 · Cited by 13
Tawfik, A. M., Nour-Eldin, N.-E. A., Naguib, N. N. N., Razek, A. A. K. A., Denewer, A. T., Bisdas, S., & Vogl, T. J. (2011) · European Journal of Radiology · doi:10.1016/j.ejrad.2011.11.012 · Cited by 13
Aveyard, P. N., Manaseki‐Holland, S., & Chambers, J. (2002) · Public Health · doi:10.1016/s0033-3506(02)00554-1 · Cited by 13
Kawahara, J., Tanaka, S., Tanaka, C., Hikihara, Y., Aoki, Y., & Yonemoto, J. (2011) · Journal of the Air & Waste Management Association · doi:10.3155/1047-3289.61.1.46 · Cited by 14
Screening for a raised rectal temperature in Africa.
Jones, R. J., O’Dempsey, T., & Greenwood, B. M. (1993) · Archives of Disease in Childhood · doi:10.1136/adc.69.4.437 · Cited by 13
Vérin, É., Similowski, T., & Sériès, F. (2003) · The Journal of Physiology · doi:10.1113/jphysiol.2002.029215 · Cited by 13
Boesby, L., Thijs, L., Elung‐Jensen, T., Strandgaard, S., & Kamper, A. (2012) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365513.2012.682164 · Cited by 13
Thoracic Epidural Anesthesia Via the Modified Taylor Approach in Infants
Gunter, J. B. (2000) · Regional Anesthesia & Pain Medicine · doi:10.1053/rapm.2000.7585 · Cited by 13
Adhesive tapes as capturing surfaces in Burkard sampling
Razmovski, V., O'Meara, T. J., Hjelmroos, M., Marks, G. B., & Tovey, E. R. (1998) · Grana · doi:10.1080/00173139809362683 · Cited by 14
Ramsay, A. S., Williamson, T. H., Parks, S., & Keating, D. (1995) · Eye · doi:10.1038/eye.1995.151 · Cited by 13
Tran, C., Yazdanpanah, M., Kyriakopoulou, L. G., Levandovskiy, V., Zahid, H., Naufer, A., Isbrandt, D., & Schulze, A. (2014) · Clinica Chimica Acta · doi:10.1016/j.cca.2014.05.007 · Cited by 13
Ou, P., Zhao, Y., Elfawal, S. K., Banka, P., & Powell, A. J. (2012) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2011.12.020 · Cited by 13
Lund, S. S., Petersen, M., Frandsen, M., Smidt, U., Parving, H. ‐., Vaag, A. A., & Jensen, T. (2008) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365510801995736 · Cited by 13
Schmidt, J. H., Brandt, C., Pedersen, E. R., Christensen‐Dalsgaard, J., Andersen, T. D., Poulsen, T., & Bælum, J. (2014) · International Journal of Audiology · doi:10.3109/14992027.2013.879339 · Cited by 13
Intra‐ and interrater agreement and reliability of the Functional Field Score
Langelaan, M., Wouters, B., Moll, A. C., de Boer, M. R., & van Rens, G. H. M. B. (2005) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2004.00266.x · Cited by 13
Ryabikov, A. N., Malyutina, S. K., Ryabikov, M. N., Kuznetsova, T., Staessen, J. A., & NIKITIN, Y. (2007) · American Journal of Hypertension · doi:10.1016/j.amjhyper.2006.09.005 · Cited by 13
Quantifying the Erlenmeyer flask deformity
Carter, A., Rajan, P. S., Deegan, P. B., Cox, T. M., & Bearcroft, P. W. P. (2012) · British Journal of Radiology · doi:10.1259/bjr/33890893 · Cited by 13
Rapid adjustment of antihypertensive drugs produces a durable improvement in blood pressure
Canzanello, V. J., Jensen, P. L., & Hunder, I. (2001) · American Journal of Hypertension · doi:10.1016/s0895-7061(00)01273-5 · Cited by 13
Lack of Agreement Between Thermodilution and Fick Methods in the Measurement of Cardiac Output
Baylor, P. A. (2006) · Journal of Intensive Care Medicine · doi:10.1177/0885066605285234 · Cited by 13
Tangelder, G. J. M., Reus, N. J., & Lemij, H. G. (2005) · Eye · doi:10.1038/sj.eye.6701993 · Cited by 15
Ott, S. M., Ichikawa, L., LaCroix, A. Z., & Scholes, D. (2008) · Journal of Clinical Densitometry · doi:10.1016/j.jocd.2008.09.002 · Cited by 13
Hodselmans, A., Dijkstra, P., van der Schans, C. P., & Geertzen, J. H. B. (2007) · Acta Dermato Venereologica · doi:10.2340/16501977-0014 · Cited by 13
Bayesian network as an aid for Food Chain Information use for meat inspection
Lupo, C., Bouquin, S. L., Balaine, L., Michel, V., Péraste, J., Petetin, I., Colin, P., Jouffe, L., & Chauvin, C. (2012) · Preventive Veterinary Medicine · doi:10.1016/j.prevetmed.2012.09.004 · Cited by 13
Haluska, B. A., Sutherland, A. J., Case, C. C., Kennedy, R., & Marwick, T. H. (2001) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(01)00406-9 · Cited by 13
The contribution of human cone photoreceptorsto the photopic flicker electroretinogram
Verma, R., & Pianta, M. J. (2009) · Journal of Vision · doi:10.1167/9.3.9 · Cited by 13
Iohexol Plasma Clearance in Determining Glomerular Filtration Rate in Diabetic Patients
Pucci, L., Bandinelli, S., Penno, G., Nannipieri, M., Rizzo, L., & Navalesi, R. (1998) · Renal Failure · doi:10.3109/08860229809045112 · Cited by 13
Ross, D. M., Watkins, D. B., Hughes, T. P., & Branford, S. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2008.105916 · Cited by 13
Abudu, N., & Levinson, S. S. (2007) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2007.291 · Cited by 13
Haller, C. S. (2014) · Brain Injury · doi:10.3109/02699052.2014.989906 · Cited by 16
Long Bone (Humerus, Femur, Tibia) Measuring Procedure in Cadavers
Garmendia, A. M., Gómez‐Valdés, J., Hernández, F., Wesp, J. K., & Sánchez‐Mejorada, G. (2014) · Journal of Forensic Sciences · doi:10.1111/1556-4029.12459 · Cited by 19
Carr, A. B., & McGivney, G. P. (2000) · Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(11)60017-6 · Cited by 13
Morales, M. S., Cuffaro, P. E., Barochiner, J., Rada, M. A., Alfie, J., Aparicio, L. S., Marín, M. J., Galarza, C. R., & Waisman, G. D. (2015) · Artery Research · doi:10.1016/j.artres.2015.03.001 · Cited by 15
Statistical Properties of Parasite Density Estimators in Malaria
Hammami, I., Nuel, G., & Garcia, A. (2013) · PLoS ONE · doi:10.1371/journal.pone.0051987 · Cited by 13
Renaud, C., Berger, J., Laillou, A., & Avallone, S. (2013) · International Journal for Vitamin and Nutrition Research · doi:10.1024/0300-9831/a000154 · Cited by 13
Ballesteros, D., Martínez-Nieto, Ó., Blancas, R., Parra, C. M., Matamala, B. L., Estebánez, B., & Chana, M. (2014) · Medicina Intensiva · doi:10.1016/j.medin.2014.09.004 · Cited by 13
Saad, H. B., Elhraiech, A., Mabrouk, K. H., Saad, H. B., Essghaier, M. B., Maatoug, C., Abdelghani, A., Bouslah, H., Charrada, A., & Rouatbi, S. (2013) · Egyptian Journal of Chest Diseases and Tuberculosis · doi:10.1016/j.ejcdt.2013.09.018 · Cited by 14
Henne, E., Anderson, J. C., Lowe, N., & Kesten, S. (2012) · BMC Pulmonary Medicine · doi:10.1186/1471-2466-12-18 · Cited by 13
Sweat gland function as a measure of radiation change
Pigott, K., Dische, S., Vojnovic, B., & Saunders, M. I. (2000) · Radiotherapy and Oncology · doi:10.1016/s0167-8140(99)00157-7 · Cited by 15
Comparative study of pressure‐flow parameters
Eri, L. M., Wessel, N., Tysland, O., & Berge, V. (2002) · Neurourology and Urodynamics · doi:10.1002/nau.10018 · Cited by 13
A pilot study of a new spectrophotometry device to measure tissue oxygen saturation
Abel, G., Allen, J., & Drinnan, M. J. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/9/1769 · Cited by 13
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.