STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 26,901–27,000 of 47,868
Bhuiyan, M. R., Deb, S., Mitchell, R. A., Teddy, P. J., & Drummond, K. J. (2012) · Journal of Clinical Neuroscience · doi:10.1016/j.jocn.2012.02.001 · Cited by 13
Comparison of DEXA and QMR for assessing fat and lean body mass in adult rats
Miller, C. N., Kauffman, T. G., Cooney, P. T., Ramseur, K. R., & Brown, L. M. (2010) · Physiology & Behavior · doi:10.1016/j.physbeh.2010.12.004 · Cited by 18
Validation of a Weight History Questionnaire to Identify Adolescent Obesity
Jenkins, T. M., Buncher, C. R., Akers, R., Daniels, S. R., Lawson, M. L., Khoury, P. R., Wilson, T. P., & Inge, T. H. (2013) · Obesity Surgery · doi:10.1007/s11695-013-0901-7 · Cited by 13
Reproducibility of the ambulatory arterial stiffness index in patients with type 1 diabetes mellitus
Laugesen, E., Hansen, K. W., Knudsen, S. T., Erlandsen, M., Ebbehøj, E., & Poulsen, P. L. (2010) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e32833531f9 · Cited by 13
Estimation of glomerular filtration rate in rabbits by a single-sample method using iodixanol
Michigoshi, Y., Katayama, R., YAMAGISHI, N., Kato, M., Saito, J., Satoh, H., & Furuhama, K. (2012) · Laboratory Animals · doi:10.1258/la.2012.011065 · Cited by 13
Non-consecutive versus consecutive footstrikes as an equivalent method of assessing gait asymmetry
Zifchock, R. A., & DAVIS, I. M. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.07.003 · Cited by 13
Comparison of indirect and direct blood pressure measurements in baboons during ketamine anaesthesia
Yeung, K. R., Lind, J. M., Heffernan, S. J., Sunderland, N., Hennessy, A., & Makris, A. (2014) · Journal of Medical Primatology · doi:10.1111/jmp.12113 · Cited by 13
Baraldo, M., Cojutti, P. G., Isola, M., Feruglio, M. T., Tursi, V., Livi, U., & Furlanut, M. (2009) · Transplantation Proceedings · doi:10.1016/j.transproceed.2009.08.077 · Cited by 13
Akram, A., Ireland, A. J., Postlethwaite, K. C., Sandy, J. R., & Jerreat, A. S. (2013) · Orthodontics and Craniofacial Research · doi:10.1111/ocr.12018 · Cited by 13
A comparison of lung function equipment with emphasis on interchangeability and methods
Munnik, P., Zanen, P., & Lammers, J. J. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/6/002 · Cited by 13
Russell, D. F., Deakin, A. H., Fogg, Q. A., & Picard, F. (2013) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-013-2812-5 · Cited by 15
Hume, D. A., Lovblom, L. E., Ahmed, A., Yeung, E. F. Y., Orszag, A., Shin, T. M., Bril, V., & Perkins, B. A. (2012) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2012.04.010 · Cited by 13
Automatic Algorithm for Monitoring Systolic Pressure Variation and Difference in Pulse Pressure
Pestel, G., Fukui, K., Hartwich, V., Schumacher, P. M., Vogt, A. P., Hiltebrand, L. B., Kurz, A. M., Fujita, Y., Inderbitzin, D., & Leibundgut, D. (2009) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181a2a8bf · Cited by 13
Teller II and Cardiff Acuity Testing in a School‐Age Deafblind Population
Johnson, C., Kran, B. S., Deng, L., & Mayer, D. L. (2009) · Optometry and Vision Science · doi:10.1097/opx.0b013e318196bd35 · Cited by 13
Hirani, V., & Aresu, M. (2012) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.2011.03832.x · Cited by 17
de Araujo, R. B., Fortes, M. R. P., Abbade, L. P. F., & Miot, H. A. (2014) · Revista da Associação Médica Brasileira · doi:10.1590/1806-9282.60.03.014 · Cited by 13
Lee, K., Milan Sonka, A., Kwon, Y. H., Garvin, M. K., & Abràmoff, M. D. (2013) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.13-12211 · Cited by 13
O'Toole, E., McDonell, W. N., WILSON, B. A., Mathews, K. A., Miller, C. W., & Sears, W. C. (2001) · American Journal of Veterinary Research · doi:10.2460/ajvr.2001.62.1761 · Cited by 13
Emond, P. D., Inglis, D., Choi, A. P. C., Tricta, J., Adachi, J. D., & Gordon, C. L. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23037 · Cited by 13
Development of a ubiquitous clinical monitoring solution to improve patient safety and outcomes
Donnelly, N., Harper, R. H. R., McCAnderson, J., Branagh, D., Kennedy, A., Caulfield, M., & McLaughlin, J. A. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6347378 · Cited by 13
Voser, E. M., Kellenberger, C. J., & Buechel, E. R. V. (2013) · Pediatric Cardiology · doi:10.1007/s00246-012-0616-x · Cited by 13
Pavan, M. V., Saura, G. E., Korkes, H. A., Nascimento, K. M., Neto, N. D. M., D’Ávila, R., Rodrigues, C. I. S., & de Almeida, F. A. (2012) · Brazilian Journal of Nephrology · doi:10.1590/s0101-28002012000100007 · Cited by 24
Truth Be Told: Evidence of Wheelchair Users' Accuracy in Reporting Their Height and Weight
Froehlich-Grobe, K., Nary, D. E., VanSciver, A., Washburn, R. A., & Aaronson, L. S. (2012) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2012.05.005 · Cited by 14
The effects of loaded, unloaded, dynamic, and static activities on foot volumetrics
McWhorter, J. W., Landers, M. R., Wallmann, H. W., Altenburger, P., Berry, K., Tompkins, D., & Higbee, C. (2006) · Physical Therapy in Sport · doi:10.1016/j.ptsp.2006.01.001 · Cited by 14
van Hedel, H. J. A., Kumru, H., Röhrich, F., & Galen, S. S. (2011) · Neurorehabilitation and neural repair · doi:10.1177/1545968311423669 · Cited by 15
Munguía‐Izquierdo, D., Santalla, A., & Legaz‐Arrese, A. (2011) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2011.08.021 · Cited by 15
Validity of a modified aerobic fitness test for adults with mental retardation
Draheim, C. C., Laurie, N. E., McCubbin, J. A., & Perkins, J. (1999) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199912000-00024 · Cited by 13
Aust, H., Dinges, G., Nardi-Hiebl, S., Koch, T., Lattermann, R., Schricker, T., & Eberhart, L. H. J. (2014) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2014.02.022 · Cited by 15
Vossinakis, I. C., Karnezis, I. A., Parry, K., & Learmonth, I. D. (2001) · Acta Orthopaedica Scandinavica · doi:10.1080/000164701317269021 · Cited by 13
Srinivas, B., Patnaik, A. N., & Rao, D. S. (2011) · Pediatric Cardiology · doi:10.1007/s00246-011-9958-z · Cited by 13
Sabeti, F., James, A. C., Essex, R. W., & Maddess, T. (2012) · Documenta Ophthalmologica · doi:10.1007/s10633-012-9366-6 · Cited by 17
Infusion clearance of subcutaneous iothalamate versus standard renal clearance
Sharma, A., Mills, M., Grey, V. L., & Drummond, K. N. (1997) · Pediatric Nephrology · doi:10.1007/s004670050372 · Cited by 13
Rose, B. O., Ishihara, H., Okawa, H., Panning, B., Piepenbrock, S., & MATSUKI, A. (2004) · Journal of Clinical Pharmacy and Therapeutics · doi:10.1111/j.1365-2710.2004.00565.x · Cited by 13
Zapletal, C., Jahnke, C., Mehrabi, A., Heß, T., Mihm, D., Angelescu, M., Stegen, P., Fonouni, H., Esmaeilzadeh, M., Gebhard, M. M., et al. (2009) · Liver Transplantation · doi:10.1002/lt.21746 · Cited by 13
Kristensen, M. T., Aagesen, M., Hjerrild, S., Larsen, P. L. S., Hovmand, B., & Ban, I. (2014) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2014.04.011 · Cited by 13
Volume calibration alone may be misleading
van den Boom, G., van der Star, L. M., Folgering, H. T. M., van Schayck, O. C. P., & van Weel, C. (1999) · Respiratory Medicine · doi:10.1016/s0954-6111(99)90104-x · Cited by 13
Cut-points for response to mannitol challenges using the forced oscillation technique
McClean, M., Htun, C., King, G. G., Berend, N., & Salome, C. M. (2010) · Respiratory Medicine · doi:10.1016/j.rmed.2010.10.013 · Cited by 16
The modified D-max is a valid lactate threshold measurement in veteran cyclists
Fell, J. W. (2007) · Journal of science and medicine in sport · doi:10.1016/j.jsams.2007.07.012 · Cited by 14
Rodríguez‐Martínez, C. E., Niño, G., & Castro-Rodríguez, J. A. (2014) · The Journal of Allergy and Clinical Immunology In Practice · doi:10.1016/j.jaip.2014.01.014 · Cited by 13
Zhang, Z., Takarada, S., & Molloi, S. Y. (2011) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01123.2010 · Cited by 13
Preferential Looking in the mentally handicapped
Chandna, A., Karki, C., Davis, J., & Doran, R. M. L. (1989) · Eye · doi:10.1038/eye.1989.127 · Cited by 13
Peeters, M. (2012) · PLoS ONE · doi:10.1371/journal.pone.0032722 · Cited by 14
Psychometric Characteristics of the Korean Version of the Roland-Morris Disability Questionnaire
Moon, J.-Y., Kim, Y. C., Park, S. Y., Lee, S. C., Choi, S. P., Nahm, F. S., Lee, P. B., Goo, E. K., & Kang, J.-M. (2011) · Journal of Korean Medical Science · doi:10.3346/jkms.2011.26.10.1364 · Cited by 13
Knox, M. K., Rivers-Bowerman, M. D., Bardgett, H., & Cowan, N. C. (2010) · European Radiology · doi:10.1007/s00330-010-1855-y · Cited by 13
Linear and nonlinear changes in the auditory brainstem response of aging humans
Lavoie, B. A., Mehta, R. L., & Thornton, A. R. D. (2008) · Clinical Neurophysiology · doi:10.1016/j.clinph.2007.12.004 · Cited by 14
Bourget, P., Lesne-Hulin, A., Sertin, A., Maillot, A., Alaya, M., & Martin, C. (1997) · International Journal of Pharmaceutics · doi:10.1016/s0378-5173(96)04797-7 · Cited by 13
The relation of arterial stiffness to endothelial function in healthy subjects
Wright, C. I., Cock, K. A. J. B.-D., Kroner, C., Hoeks, A. P. G., & Draijer, R. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/5/010 · Cited by 13
Data required for testicular dose calculation during radiotherapy of seminoma
Mazonakis, M., Kokona, G., Varveris, H., Damilakis, J. E., & Gourtsoyiannis, N. (2006) · Medical Physics · doi:10.1118/1.2208936 · Cited by 13
Park, C. M., March, K., Williams, S., Kukadia, S., Ghosh, A. K., Jones, S. H., Tillin, T., Chaturvedi, N., & Hughes, A. D. (2013) · PLoS ONE · doi:10.1371/journal.pone.0075098 · Cited by 14
New technique for prostate volume assessment
Habes, M., Bahr, J., Schiller, T., Kühn, J., Hoppe, L., Burchardt, M., & Hoffmann, W. U. (2013) · World Journal of Urology · doi:10.1007/s00345-013-1220-2 · Cited by 13
Andrade, J. A., Figueiredo, L. C., Santos, T. R. T., Paula, A. C. V., Bittencourt, N. F. N., & Fonseca, S. T. (2012) · Brazilian Journal of Physical Therapy · doi:10.1590/s1413-35552012000400007 · Cited by 17
Relative validity of a semi-quantitative FFQ in 3-year-old Polish children
Sochacka-Tatara, E., & Pac, A. (2013) · Public Health Nutrition · doi:10.1017/s1368980013002292 · Cited by 17
Mechanisms of Decrease in Fractional Exhaled Nitric Oxide During Acute Bronchoconstriction
Cattoni, I., Guarnieri, G., Tosetto, A., Mason, P., Scarpa, M. C., Saetta, M. P., & Maestrelli, P. (2013) · CHEST Journal · doi:10.1378/chest.12-1374 · Cited by 13
A re-analysis of the iron content of plant-based foods in the United Kingdom
Bruggraber, S. F. A., Chapman, T., Thane, C. W., Olson, A. D., Jugdaohsingh, R., & Powell, J. J. (2012) · British Journal Of Nutrition · doi:10.1017/s0007114512000360 · Cited by 15
Geerts, L., & Widmer, T. (2011) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.3109/14767058.2010.485232 · Cited by 14
Miller, L., Marnane, K., Ziviani, J. M., & Boyd, R. N. (2013) · Physical & Occupational Therapy In Pediatrics · doi:10.3109/01942638.2013.806978 · Cited by 13
Viral load testing in a resource‐limited setting: quality control is critical
Greig, J. E., du Cros, P., Klarkowski, D. B., Mills, C., Jørgensen, S., Harrigan, P. R., & O'Brien, D. P. (2011) · Journal of the International AIDS Society · doi:10.1186/1758-2652-14-23 · Cited by 16
Echocardiographic estimation of mean pulmonary artery pressure in critically ill patients
Laver, R. D., Wiersema, U. F., & Bersten, A. D. (2014) · The Ultrasound Journal · doi:10.1186/2036-7902-6-9 · Cited by 13
Nagai, T., Kohsaka, S., Anzai, T., Yoshikawa, T., Fukuda, K., & Satô, T. (2012) · CHEST Journal · doi:10.1378/chest.11-1893 · Cited by 13
High-Pitch 128-Slice Dual-Source CT for the Assessment of Coronary Stents in a Phantom Model
Donati, O. F., Burg, M. C., Desbiolles, L. M., Karlo, C. A., Stolzmann, P., Bunck, A. C., Baumueller, S., Marinček, B., Seifarth, H., Alkadhi, H., et al. (2010) · Academic Radiology · doi:10.1016/j.acra.2010.06.017 · Cited by 13
Shamsuddin, N., Poh, B. K., Zakaria, S. Z. S., Noor, M. I., & Jamal, R. (2015) · International Journal of Public Health Research · Cited by 23
Garrow, A. P., Khan, N. U., Tyson, S. F., Vestbo, J., Singh, D., & Yorke, J. (2015) · Thorax · doi:10.1136/thoraxjnl-2014-206410 · Cited by 14
Lasnon, C., Quak, E., Briand, M., Gu, Z., Louis, M.-H., & Aide, N. (2013) · EJNMMI Research · doi:10.1186/2191-219x-3-5 · Cited by 14
ShahAli, S., Arab, A. M., Talebian, S., Ebrahimi, E., Bahmani, A., Karimi, N., & Nabavi, H. (2014) · Journal of Bodywork and Movement Therapies · doi:10.1016/j.jbmt.2014.05.009 · Cited by 15
Lewis, J. E., Tannenbaum, S. L., Gao, J., Melillo, A. B., Long, E. G., Alonso, Y., Konefal, J., Woolger, J. M., Leonard, S., Singh, P. K., et al. (2011) · Medical Devices Evidence and Research · doi:10.2147/mder.s24291 · Cited by 13
Wagenmakers, R., Stevens, M. J., van den Akker‐Scheek, I., Zijlstra, W., & Groothoff, J. W. (2007) · Physical Therapy · doi:10.2522/ptj.20060321 · Cited by 13
Validity and relative validity of a novel digital approach for 24-h dietary recall in athletes
Baker, L. B., Heaton, L. E., Stein, K. W., Nuccio, R. P., & Jeukendrup, A. E. (2014) · Nutrition Journal · doi:10.1186/1475-2891-13-41 · Cited by 18
Chan, D. D., Gossett, P. C., Butz, K. D., Nauman, E. A., & Neu, C. P. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.05.026 · Cited by 13
Vromman, V., Baert, K., Vanderperren, H., Goeyens, L., Huyghebaert, A. D., Maghuin‐Rogister, G., Scippo, M., Moons, E., Vinkx, C., Saegerman, C., et al. (2011) · Food Control · doi:10.1016/j.foodcont.2011.10.047 · Cited by 13
Patil, R., van Brakel, R., Iyer, K., Slater, J. H., de Putter, C., & Cune, M. S. (2011) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2011.02335.x · Cited by 13
The relationships between tracheal index and lung volume parameters in mild-to-moderate COPD
Eom, J. S., Lee, G., Lee, H. Y., Oh, J. Y., Woo, S., Jeon, K., Um, S., Koh, W., Suh, G. Y., Chung, M. P., et al. (2013) · European Journal of Radiology · doi:10.1016/j.ejrad.2013.08.028 · Cited by 16
Effects of one-lung ventilation on thermodilution-derived assessment of cardiac output
Trepte, C. J. C., Haas, S., Meyer, N., Gebhardt, M., Goepfert, M. S., Goetz, A. E., & Reuter, D. A. (2012) · British Journal of Anaesthesia · doi:10.1093/bja/aes032 · Cited by 13
The psychometric performance of generic preference-based measures for patients with pressure ulcers
Palfreyman, S. J., & Mulhern, B. J. (2015) · Health and Quality of Life Outcomes · doi:10.1186/s12955-015-0307-4 · Cited by 13
Cheng, A. C. K., Leung, D. Y. L., Cheung, E. Y. Y., Fan, D. S. P., Law, R. W. K., & Lam, D. S. (2005) · Clinical and Experimental Ophthalmology · doi:10.1111/j.1442-9071.2005.00988.x · Cited by 15
Gref, M., & Karp, K. H. (2007) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfm411 · Cited by 13
de Laat, F. A., Rommers, G. M., Geertzen, J. H. B., & Roorda, L. D. (2010) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2010.06.013 · Cited by 15
Punpanich, W., Boon‐yasidhi, V., Chokephaibulkit, K., Prasitsuebsai, W., Chantbuddhiwet, U., Leowsrisook, P., Hays, R. D., & Detels, R. (2010) · Quality of Life Research · doi:10.1007/s11136-010-9708-3 · Cited by 13
Ghoch, M. E., Alberti, M., Capelli, C., Calugi, S., Battistini, N., Pellegrini, M., Šubašić, S., Lanza, M., & Grave, R. D. (2012) · International Journal of Food Sciences and Nutrition · doi:10.3109/09637486.2012.658761 · Cited by 15
Zhang, J., Arena, C., Pednekar, A. S., Lambert, B., Dees, D., Lee, V. V., & Muthupillai, R. (2015) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25035 · Cited by 13
Multi-functionality of computer-aided quantitative vertebral fracture morphometry analyses.
Oei, L., Ly, F., Saddy, S. E., Makurthou, A. A., Albert Hofman, D., van Rooij, F. J. A., Uitterlinden, A. G., Zillikens, M. C., Rivadeneira, F., & Oei, E. H. G. (2013) · Europe PMC (PubMed Central) · doi:10.3978/j.issn.2223-4292.2013.09.03 · Cited by 13
Bonaccorsi, G., Bassetti, A., Chiari, S., Dirindelli, P., Lorini, C., Menicalli, C., Santomauro, F., & Martinetti, M. G. (2012) · PubMed · doi:10.3275/8722 · Cited by 13
Value of preoperative phakic intraocular lens simulation using optical coherence tomography
Doors, M., Berendschot, T. T. J. M., Hendrikse, F., Webers, C. A. B., & Nuijts, R. M. M. A. (2009) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2008.11.033 · Cited by 13
Patil, V. M., Patel, F. D., Chakraborty, S., Oinam, A. S., & Sharma, S. C. (2011) · British Journal of Radiology · doi:10.1259/bjr/33758793 · Cited by 13
ULTRASONIC EVALUATION OF ANTERIOR SHOULDER TRANSLATION IN NORMAL SHOULDERS
Yeap, J. S., McGregor, A. H., Humphries, K. N., & Wallace, A. L. (2003) · Journal of Musculoskeletal Research · doi:10.1142/s0218957703001058 · Cited by 13
Garcia‐Simon, R., Oros, D., Gracia‐Cólera, D., Moreno, E., Paulés, C., Cañizares, S., Gascón, E., & Fabre, E. (2014) · Journal of obstetrics and gynaecology research · doi:10.1111/jog.12553 · Cited by 13
Baroreflex physiology studied in healthy subjects with very infrequent muscle sympathetic bursts
Diedrich, A., Crossman, A. A., Beightol, L. A., Tahvanainen, K. U. O., Kuusela, T., Ertl, A. C., & Eckberg, D. L. (2012) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00509.2011 · Cited by 13
Accuracy of Indirect Estimation of Power Output From Uphill Performance in Cycling
Millet, G. P., Tronche, C., & Grappe, F. (2014) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2013-0320 · Cited by 13
Avaliação de um programa de traçado cefalométrico
Vasconcelos, M. H. F., Janson, G., de Freitas, M. R., & Henriques, J. F. C. (2006) · Revista Dental Press de Ortodontia e Ortopedia Facial · doi:10.1590/s1415-54192006000200007 · Cited by 13
Mustonen, A. O. T., Koivikko, M. P., Haapamäki, V. V., Kiuru, M. J., Lamminen, A., & Koskinen, S. K. (2007) · Acta Radiologica · doi:10.1080/02841850601045138 · Cited by 13
Güngör, G., Karakurt, Z., Adıgüzel, N., Aydın, R., Balcı, M. K., Saltürk, C., Sancar, R., Solmaz, S., & Moçin, Ö. Y. (2013) · Respiratory Care · doi:10.4187/respcare.02009 · Cited by 13
Accuracy of bone assessments for verifying age in adolescents - application in sport
Braude, S., Henning, L., & Lambert, M. (2007) · South African Journal of Radiology · doi:10.4102/sajr.v11i2.42 · Cited by 13
Stecco, C., Macchi, V., Baggio, L., Porzionato, A., Berizzi, A., Aldegheri, R., & De, R. (2012) · Surgical and Radiologic Anatomy · doi:10.1007/s00276-012-1014-z · Cited by 13
Cerutti, H., Muzzi, C., Leoncini, R., Scapellato, C., Cortelazzo, A., Furlani, E., & Guerranti, R. (2011) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.20457 · Cited by 13
Larsen, M. D., Lose, G., Guldberg, R., & Gradel, K. O. (2015) · International Urogynecology Journal · doi:10.1007/s00192-015-2840-4 · Cited by 14
Castellani, S., Bacci, M., Ungar, A., Prati, P., Serio, C. D., Geppetti, P., Masotti, G., Serneri, G. G. N., & Gensini, G. F. (2006) · Hypertension · doi:10.1161/01.hyp.0000248533.58693.c4 · Cited by 14
Panou, A., Stanitski, D. F., Stanitski, C. L., Peccati, A., & Portinaro, N. M. (2015) · Journal of Orthopaedic Surgery and Research · doi:10.1186/s13018-015-0200-1 · Cited by 13
Development and Validation of the Online Self-Reported Walking and Exercise Questionnaire (OSWEQ)
Taylor, N. J., Crouter, S. E., Lawton, R., Conner, M. T., & Prestwich, A. (2013) · Journal of Physical Activity and Health · doi:10.1123/jpah.10.8.1091 · Cited by 13
Conger, S. A., Scott, S. N., & Bassett, D. R. (2014) · British Journal of Sports Medicine · doi:10.1136/bjsports-2014-093540 · Cited by 13
Turner‐Stokes, L. F., Williams, H., Rose, H., Harris, S., & Jackson, D. M. (2010) · Clinical Rehabilitation · doi:10.1177/0269215510375904 · Cited by 13
Daskalov, I. R., Petrovsky, P. D., & Demirevska, L. (2012) · Cardiovascular Ultrasound · doi:10.1186/1476-7120-10-46 · Cited by 13
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.