STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 27,201–27,300 of 47,868
The test–retest reliability of motor performance measures after traumatic brain injury
Vartiainen, M. V., Rinne, M. B., Lehto, T., Pasanen, M. E., Sarajuuri, J. M., & Alaranta, H. (2006) · Advances in Physiotherapy · doi:10.1080/14038190600700195 · Cited by 13
The effect of posture on body circumferences in older adults
Sousa, A. S., de Sousa, O. L., & do Amaral, T. F. (2013) · Journal of Human Nutrition and Dietetics · doi:10.1111/jhn.12093 · Cited by 16
Hornuß, C., Dolch, M. E., Janitza, S., Souza, K. E., Praun, S., Apfel, C. C., & Schelling, G. (2013) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-013-9452-7 · Cited by 13
Kneafsey, L. C., Cunningham, S. J., Petrie, A., & Hutton, T. J. (2008) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2006.11.024 · Cited by 13
Self-Reported Physical Activity Improves Prediction of Body Fatness in Young Adults
Zanovec, M. T., Johnson, L. G., Marx, B. D., Keenan, M. J., & Tuuri, G. (2009) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e318185d359 · Cited by 13
Sivanandam, A., Siva, S., Bhandari, M., & Menon, M. (2008) · British Journal of Urology · doi:10.1111/j.1464-410x.2008.07883.x · Cited by 13
Tafeit, E., Möller, R., Sudi, K. M., & Reibnegger, G. J. (2000) · Computers in Biology and Medicine · doi:10.1016/s0010-4825(00)00011-1 · Cited by 13
Real-time duplex PCR for simultaneous HPV 16 and HPV 18 DNA quantitation
Jacquin, É., Saunier, M., Mauny, F., Schwarz, E., Mougin, C., & Prétet, J. (2013) · Journal of Virological Methods · doi:10.1016/j.jviromet.2013.07.023 · Cited by 16
Faustini, M., Bronzo, V., Maffeo, G., Russo, V., Munari, E., & Vigo, D. (2003) · Zentralblatt für Veterinärmedizin Reihe A · doi:10.1046/j.1439-0442.2003.00581.x · Cited by 13
Pulmonary Arterial Pressure Can Be Estimated by Transesophageal Pulsed Doppler Echocardiography
Kawahito, S., Kitahata, H., Tanaka, K., Nozaki, J., & Oshita, S. (2001) · Anesthesia & Analgesia · doi:10.1097/00000539-200106000-00002 · Cited by 13
Iguchi, T., Takemoto, Y., Shimada, K., Matsumoto, K., Nakanishi, K., Otsuka, K., Hyodo, E., Hirohashi, K., Tahara, A., & Yoshiyama, M. (2013) · Hypertension Research · doi:10.1038/hr.2013.35 · Cited by 14
Validation of a triglyceride meter for use in pregnancy
Barrett, H. L., Nitert, M. D., dʼEmden, M. C., McIntyre, D. H., & Callaway, L. K. (2014) · BMC Research Notes · doi:10.1186/1756-0500-7-679 · Cited by 13
Predicting prescribed magnification*
Wolffsohn, J. S., & Eperjesi, F. (2004) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2004.00215.x · Cited by 13
Bongard, F. S., Lee, T., LEIGHTON, T. A., & Liu, S.-Y. (1995) · The Journal of Clinical Monitoring · doi:10.1007/bf01616992 · Cited by 13
Survival, haemodynamics and cardiac remodelling follow up in mice after myocardial infarction
Pons, S., Fornés, P., Hagège, A. A., Heudes, D., Giudicelli, J., & Richer, C. (2003) · Clinical and Experimental Pharmacology and Physiology · doi:10.1046/j.1440-1681.2003.03784.x · Cited by 13
Target alternative vaccine safety testing strategies for pertussis toxin
Arciniega, J. L., Corvette, L., Hsu, H., Lynn, F., Romani, T. A., & Dobbelaer, R. (2011) · Procedia in Vaccinology · doi:10.1016/j.provac.2011.10.026 · Cited by 13
Evaluation of Leg-to-Leg BIA in Assessing Body Composition in High-School-Aged Males and Females
Unick, J. L., Utter, A. C., Schumm, S., & McInnis, T. (2006) · Research in Sports Medicine · doi:10.1080/15438620600992585 · Cited by 13
Statistical limits in sonographic estimation of birth weight
Scioscia, M., Scioscia, F., Scioscia, G., & Bettocchi, S. (2014) · Archives of Gynecology and Obstetrics · doi:10.1007/s00404-014-3384-4 · Cited by 13
Phillips, K. P., Harberts, D. B., Johnston, L., & O’Donnell, D. (2006) · Heart Rhythm · doi:10.1016/j.hrthm.2006.10.018 · Cited by 13
Decisions, choice and shared decision making in antenatal clinics: An observational study
Garrard, F., Ridd, M. J., Narayan, H., & Montgomery, A. A. (2015) · Patient Education and Counseling · doi:10.1016/j.pec.2015.04.004 · Cited by 15
Evaluation of the pressure phosphene tonometer as a self‐tonometer
Naruse, S., Mori, K., & Kinoshita, S. (2005) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2005.00311.x · Cited by 13
Opposing placental gradients for thiocyanate and cotinine at birth
Nafstad, P. H. J., Magnus, P. M., & Stray-Pedersen, B. (1995) · Early Human Development · doi:10.1016/0378-3782(95)01641-f · Cited by 13
Yoon, H. J., Kim, P. N., Kim, A., & Lee, M.-G. (2006) · Journal of Clinical Ultrasound · doi:10.1002/jcu.20218 · Cited by 13
Intra- and inter-rater reliability of a modified measure of hand behind back range of motion
van den Dolder, P. A., Ferreira, P. H., & Refshauge, K. M. (2013) · Manual Therapy · doi:10.1016/j.math.2013.08.002 · Cited by 13
Cornea Measurement Comparison with Orbscan II and EyeSys Videokeratoscope
Douthwaite, W. A., & Mallen, E. A. H. (2007) · Optometry and Vision Science · doi:10.1097/opx.0b013e3180dc9a3a · Cited by 13
Reference equation for spirometry interpretation for Eastern India
Dasgupta, A., Ghoshal, A. G., Mukhopadhyay, A., Kundu, S., Mukherjee, S., Roychowdhury, S., Dhar, R., & Sengupta, S. (2015) · Lung India · doi:10.4103/0970-2113.148443 · Cited by 13
Xenon measurement in breathing systems: a comparison of ultrasonic and thermal conductivity methods
King, R., Bretland, M., Wilkes, A. R., & Dingley, J. (2005) · Anaesthesia · doi:10.1111/j.1365-2044.2005.04379.x · Cited by 13
Thalamic volume measurement in normal fetuses using three‐dimensional sonography
Sotiriadis, A., Dimitrakopoulos, I., Eleftheriades, M. I., Αγοραστός, Θ., & Makrydimas, G. (2012) · Journal of Clinical Ultrasound · doi:10.1002/jcu.21888 · Cited by 14
Coronary haemodynamics in left ventricular hypertrophy.
Wallbridge, D. R., & Cobbe, S. M. (1996) · Heart · doi:10.1136/hrt.75.4.369 · Cited by 13
Comparison of two different microbiological test kits for detection of periodontal pathogens
Cosgarea, R., Bäumer, A., Pretzl, B., Zehaczek, S., & Kim, T. (2010) · Acta Odontologica Scandinavica · doi:10.3109/00016350903514848 · Cited by 13
Malm, S., Frigstad, S., Støylen, A., Torp, H. G., Sagberg, E., & Skjærpe, T. (2006) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2005.07.017 · Cited by 13
Otake, M., Miyata, S., Noda, A., Koike, Y., Hara, Y., Sugiura, M., Minoshima, M., Kojima, J., Nakata, S., & Nakashima, T. (2010) · Respiration · doi:10.1159/000321238 · Cited by 15
A blended estimator for a measure of agreement with a gold standard
Harris, I. R., Burch, B. D., & Laurent, R. T. S. (2001) · Journal of Agricultural Biological and Environmental Statistics · doi:10.1198/108571101317096541 · Cited by 14
Grothues, F., Bönigk, H., Graessner, J., Kanowski, M., & Klein, H. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20986 · Cited by 14
A new craniofacial diagnostic technique: The Sydney diagnostic system
Moate, S. J., Geenty, J. P., Shen, G., & Darendeliler, M. A. (2007) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2005.04.047 · Cited by 13
A New Double Cuff Sphygmotonometer for Accurate Blood Pressure Measurement.
Tochikubo, O., Watanabe, J. A., Hanada, K., Miyajima, E., & Kimura, K. (2001) · Hypertension Research · doi:10.1291/hypres.24.353 · Cited by 13
Nielsen, A. L., Thunedborg, P., Brinkenfeldt, H., Hegbrant, J., Jensen, H., & Wandrup, J. H. (1999) · Blood Purification · doi:10.1159/000014397 · Cited by 13
Ligot, G. (2012) · The Open Forest Science Journal · doi:10.2174/1874398601205010015 · Cited by 13
Do Specific Weight Formulas for Fetuses ≤ 1500 g Really Improve Weight Estimation?
Hoopmann, M., Bernau, B., Hart, N., Schild, R. L., & Siemer, J. (2010) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/s-0028-1109481 · Cited by 15
Conaire, E. Ó., Rushton, A., & Wright, C. (2011) · Manual Therapy · doi:10.1016/j.math.2011.01.008 · Cited by 19
McCann, M. E., Hill, D. J., Thomas, K. C., Zurakowski, D., & Laussen, P. C. (2005) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000171231.29328.9f · Cited by 13
Cross, M. H., & Brown, D. G. (1996) · The Journal of Clinical Monitoring · doi:10.1007/bf02025307 · Cited by 13
The accuracy of pulse oximetry at two haematocrit levels
Vegfors, M., Lindberg, L., Öberg, P. Å., & Lennmarken, C. (1992) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.1992.tb03496.x · Cited by 13
Where exactly is the deep inguinal ring in patients with inguinal hernias?
Clark, C. L. I., Conaghan, P., Hassanally, D. A., & Griffin, M. (2004) · Surgical and Radiologic Anatomy · doi:10.1007/s00276-003-0203-1 · Cited by 13
Sproule, D. M., Montes, J., Young, S. D., Montgomery, M., Battista, V., Shen, W., Punyanitya, M., Vivo, D. C. D., & Kaufmann, P. (2010) · Journal of Child Neurology · doi:10.1177/0883073810365185 · Cited by 13
Femoral anteversion in infants: a method using ultrasound
Prasad, S. S., Bruce, C. E., Crawford, S., Higham, J., & Garg, N. K. (2003) · Skeletal Radiology · doi:10.1007/s00256-003-0652-y · Cited by 13
Gilard, M., Pennec, P.-Y., Cornily, J., Vinsonneau, U., Gal, G. L., Nonent, M., Mansourati, J., & Boschat, J. (2006) · European Journal of Radiology · doi:10.1016/j.ejrad.2006.02.010 · Cited by 13
Sartório, A., Narici, M. V., Conti, A., Giambona, S., Ortolani, S., & Faglia, G. (1997) · Journal of Endocrinological Investigation · doi:10.1007/bf03347994 · Cited by 14
Random sample estimates of tree mean for fruit size and colour in apple
Miranda, C. R. N. D. O., Girard, T., & Lauri, P. (2007) · Scientia Horticulturae · doi:10.1016/j.scienta.2006.12.006 · Cited by 13
Wirbelauer, C., Thannhäuser, C., & Pham, D. T. (2009) · Cornea · doi:10.1097/ico.0b013e3181861cf0 · Cited by 13
Respiratory and non-respiratory sinus arrhythmia: implications for heart rate variability
McMullen, M. K., Whitehouse, J. M., Shine, G., & Towell, A. (2011) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-011-9327-8 · Cited by 16
Thein, E., Becker, M., Anetzberger, H., Hammer, C., & Meßmer, K. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00362.2003 · Cited by 13
Leiria, T. L. L., Pellanda, L. C., Magalhães, E., & de Lima, G. G. (2007) · Arquivos Brasileiros de Cardiologia · doi:10.1590/s0066-782x2007001300001 · Cited by 13
Reproducibility of IVUS border detection for carotid atherosclerotic plaque assessment
Siewiorek, G. M., Loghmanpour, N. A., Winston, B., Wholey, M. H., & Finol, E. A. (2011) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2011.09.013 · Cited by 13
Assessing Pedometer Accuracy while Walking, Skipping, Galloping, Sliding, and Hopping
Smith, J. D., & Schroeder, C. A. (2008) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0b013e31815f2f42 · Cited by 14
Hodselmans, A. P., Dijkstra, P. U., Geertzen, J. H. B., & van der Schans, C. P. (2008) · Journal of Occupational Rehabilitation · doi:10.1007/s10926-008-9143-2 · Cited by 15
Li, X., Li, Q., Li, S., Li, D., & Initiative, T. A. D. N. (2015) · CNS Neuroscience & Therapeutics · doi:10.1111/cns.12415 · Cited by 13
Sen, B., Mahalanabis, D., Shaikh, S., Kurpad, A. V., & Bose, K. (2008) · British Journal Of Nutrition · doi:10.1017/s0007114508019867 · Cited by 13
Coulthard, M. G., Nelson, A., Smith, T., & Perry, J. D. (2010) · Journal of Clinical Pathology · doi:10.1136/jcp.2010.077990 · Cited by 13
Effect of short schemes on body composition measurements using Air-Displacement Plethysmography
Hull, H. R., & Fields, D. A. (2005) · Dynamic Medicine · doi:10.1186/1476-5918-4-8 · Cited by 13
Fast psychophysical procedures for clinical testing
Phipps, J. A., Zele, A. J., Dang, T., & Vingrys, A. J. (2001) · Clinical and Experimental Optometry · doi:10.1111/j.1444-0938.2001.tb05036.x · Cited by 17
Reconstructing bulk isotope ratios from compound‐specific isotope ratios
Morrison, D. J., Cooper, K., & Preston, T. (2010) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.4577 · Cited by 13
Cardiac Image Segmentation for Contrast Agent Videodensitometry
Mischi, M., Kalker, A. A. C. M., & Korsten, H. H. M. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.840500 · Cited by 15
Cirelli, N., Moens, A., Lebrun, P., Gueuning, C. O., Delogne‐Desnoeck, J., Vanbellinghen, A.-M., & Meuris, S. (1999) · Biology of Reproduction · doi:10.1095/biolreprod61.2.458 · Cited by 13
Heuck, C., & Wolthers, O. D. (1998) · Journal of Endocrinology · doi:10.1677/joe.0.1590127 · Cited by 13
Diagnosis of sleep apnea by the analysis of heart rate variation: A mini review
Hayano, J., Watanabe, E., Saito, Y., Sasaki, F., Kawai, K., Kodama, I., & Sakakibara, H. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091905 · Cited by 13
Single-breath method for assessing the viscoelastic properties of the respiratory system
Antonaglia, V., Grop, A., Demanins, P., Beltrame, F., Lucangelo, U., Peratoner, A., Simoni, L. D., Gullo, A., & Milic‐Emili, J. (1998) · European Respiratory Journal · doi:10.1183/09031936.98.12051191 · Cited by 13
O'Halloran, J. P., Kemp, A. S., Salmon, D. P., Tariot, P. N., & Schneider, L. S. (2011) · Current Alzheimer Research · doi:10.2174/156720511795563692 · Cited by 15
The standardised copy of pentagons test
Fountoulakis, K. Ν., Siamouli, M., Panagiotidis, P. T., Magiria, S., Kantartzis, S., Terzoglou, V. A., & Oral, T. (2011) · Annals of General Psychiatry · doi:10.1186/1744-859x-10-13 · Cited by 13
Frenţiu, T., Ponta, M., & Hategan, R. M. (2013) · Chemistry Central Journal · doi:10.1186/1752-153x-7-43 · Cited by 13
The Ramp Power Test: A Power Assessment During a Functional Task for Older Individuals
Signorile, J., Sandler, D., Kempner, L., Stanziano, D. C., Ma, F., & Roos, B. A. (2007) · The Journals of Gerontology Series A · doi:10.1093/gerona/62.11.1266 · Cited by 14
Dendere, R., Potgieter, J. H., Steiner, S., Whiley, S. P., & Douglas, T. S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2447575 · Cited by 14
Indirect and Direct Gas Exchange at Maximum Exercise in Beryllium Sensitization and Disease
Lundgren, R. A., Maier, L. A., Rose, C. S., Balkissoon, R., & Newman, L. S. (2001) · CHEST Journal · doi:10.1378/chest.120.5.1702 · Cited by 14
van MASTRIGT, R., Pel, J. J. M., Chung, J. W. N. C. F., & de Zeeuw, S. (2009) · Indian Journal of Urology · doi:10.4103/0970-1591.45546 · Cited by 13
Nendel, C., Schmutz, U., Venezia, A., Piro, F., & Rahn, C. R. (2009) · Plant and Soil · doi:10.1007/s11104-009-0015-0 · Cited by 13
Reliability of MR Perfusion-Weighted and Diffusion-Weighted Imaging Mismatch Measurement Methods
Luby, M. L., & Warach, S. J. (2007) · American Journal of Neuroradiology · doi:10.3174/ajnr.a0643 · Cited by 13
Body composition during GH replacement in adults – methodological variations with respect to gender
Koranyi, J., Bosaeus, I. G., Alpsten, M., Bengtsson, B., & Johannsson, G. (2006) · European Journal of Endocrinology · doi:10.1530/eje.1.02118 · Cited by 14
Assessment of a rapid method for assessing adequacy of calcium intake
Green, H., Booth, C. L., & Bunning, R. (2002) · Asia Pacific Journal of Clinical Nutrition · doi:10.1046/j.1440-6047.2002.00279.x · Cited by 13
8-Iso-Prostaglandin F 2α as a Risk Marker in Patients With Coronary Heart Disease
Vassalle, C., & Andreassi, M. G. (2004) · Circulation · doi:10.1161/01.cir.0000141257.61498.6a · Cited by 13
O’Leary, S. P., Christensen, S. W., Verouhis, A., Pape, M., Nilsen, O., & McPhail, S. (2015) · Physiotherapy · doi:10.1016/j.physio.2015.01.005 · Cited by 14
de Bruin, P. F. C., Watson, R. A., Khalil, N., & Pride, N. B. (1998) · European Respiratory Journal · doi:10.1183/09031936.98.12030672 · Cited by 13
Wajon, P., & Lindsay, G. (1998) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1016/s1053-0770(98)90231-2 · Cited by 13
Gurrici, S., Hartriyanti, Y., HAUTVAST, J. G. A. J., & Deurenberg, P. (1999) · Asia Pacific Journal of Clinical Nutrition · doi:10.1046/j.1440-6047.1999.00088.x · Cited by 16
Kim, S. H., Ryu, K. H., Yoon, J.-H., Lee, Y., Paik, J. H., Kim, S. J., Jung, H. K., & Lee, K. H. (2014) · Acta Radiologica · doi:10.1177/0284185114560936 · Cited by 13
Pulmonary malignancy in silicosis: Factors associated with radiographic detection
Arakawa, H., SHIDA, H., Saito, Y., Johkoh, T., Tomiyama, N., Tsubamoto, M., & Honma, K. (2007) · European Journal of Radiology · doi:10.1016/j.ejrad.2007.08.035 · Cited by 13
George, S., Rodriguez, I., Ipe, D., Sager, P. T., Gussak, I. B., & Vajdić, B. (2011) · The Journal of Clinical Pharmacology · doi:10.1177/0091270011430505 · Cited by 13
Warner, M. B., Cotton, A. M., & Stokes, M. J. (2008) · Journal of Medical Engineering & Technology · doi:10.1080/03091900701695533 · Cited by 13
The phenol red thread test for lacrimal volume – does it matter if the eyes are open or closed?
Doughty, M. J., Whyte, J., & Li, W. (2007) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2007.00500.x · Cited by 13
Diagnosing dental caries in populations with different levels of dental fluorosis
Nyvad, B., Mačhiulskienė, V., Fejerskov, O., & Bælum, V. (2009) · European Journal Of Oral Sciences · doi:10.1111/j.1600-0722.2008.00598.x · Cited by 18
Assessment of new hyaluronic acid assays and their impact on FibroMeter scores
Veillon, P., Gallois, Y., Moal, V., Fouchard‐Hubert, I., Isabelle, C., Larcher, F., Dib, N., Boursier, J., Oberti, F., Laafi, J., et al. (2010) · Clinica Chimica Acta · doi:10.1016/j.cca.2010.11.009 · Cited by 14
Diastolic function improves after resolution of takotsubo cardiomyopathy
Kumar, S., Waldenborg, M., Bhumireddy, P., Ramkissoon, K., Loiske, K., Innasimuthu, A. L., Grodman, R., Heitner, J. F., Emilsson, K., & Lazar, J. (2014) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12188 · Cited by 13
A multivariate model for predicting segmental body composition
Tian, S., Mioche, L., Denis, J., & Morio, B. (2013) · British Journal Of Nutrition · doi:10.1017/s0007114513001803 · Cited by 14
Carretero, M., Fontanals, J., Agustí, M., Arguis, M., Martínez-Ocón, J., Ruiz, A., & Ríos, J. (2010) · Resuscitation · doi:10.1016/j.resuscitation.2009.12.021 · Cited by 13
Accuracy of estimating intra-abdominal fat in obese women
Ball, S., & Swan, P. D. (2003) · Cited by 13
A self‐administered test of taste function using “Taste Strips”
Wolf, A., Varga, L., Wittibschlager, L., Renner, B., & Mueller, C. A. (2015) · International Forum of Allergy & Rhinology · doi:10.1002/alr.21681 · Cited by 13
Short-term reproducibility of impaired fasting glycaemia, impaired glucose tolerance and diabetes
Rasmussen, S. S., Glümer, C., Sandbæk, A., Lauritzen, T., Carstensen, B., & Borch‐Johnsen, K. (2007) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2007.11.003 · Cited by 13
Deun, S. V., Stappaerts, K. H., Levin, O., Janssens, L., & Staes, F. F. G. M. (2011) · Journal of Athletic Training · doi:10.4085/1062-6050-46.4.366 · Cited by 13
Franco‐Sena, A. B., Rebelo, F. M., Pinto, T., Farias, D., Silveira, G. V., Mendes, R., Henriques, V., & Kac, G. (2015) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/1471-0528.13826 · Cited by 14
Accuracy and precision of transcardiopulmonary thermodilution in patients with cardiogenic shock
Schmid, B., Fink, K., Olschewski, M., Richter, S., Schwab, T., Brunner, M. P., & Busch, H.-J. (2015) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-015-9782-8 · Cited by 13
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.