STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 28,301–28,400 of 47,868
Zhang, X., Liao, H., Ye, R., Li, X., Gou, Q., Zhang, Z., Shi, R., Meng, Q., Zhuoma, Z., Zhang, H., et al. (2021) · Journal of Clinical Hypertension · doi:10.1111/jch.14312 · Cited by 13
The Reliability of the 300-Yard Shuttle Run in High School Girls Basketball Players
White, M. D. K., Sevene, T. G., & Adams, K. (2015) · Journal of Sports Science · doi:10.17265/2332-7839/2015.05.002 · Cited by 12
Bildgebende Verfahren in der Rheumatologie: Bildgebung bei der Psoriasisarthritis (PsA)
Rau, R., Wasserberg, S., Backhaus, M., Braun, J., Edelmann, E., Kellner, H., Ostendorf, B. C., Rudwaleit, M., SANDROCK, D., Schalm, J., et al. (2006) · Zeitschrift für Rheumatologie · doi:10.1007/s00393-005-0005-4 · Cited by 12
Acceptable, Equivalent, or Better: Approaches for Alternatives to Official Compendial Procedures
Hauck, W. W., DeStefano, A. J., Cecil, T. L., Abernethy, D. R., Koch, W. F., & Williams, R. (2009) · Cited by 14
Swaminathan, S., Diffey, B., & Vaz, M. A. P. (2006) · PubMed · Cited by 12
Shaikh, S., & Mahalanabis, D. (2004) · American Journal of Human Biology · doi:10.1002/ajhb.20030 · Cited by 12
Kotecka, B. M., Rieckmann, K. H., Davis, T. M. E., Batty, K. T., & Ilett, K. F. (2003) · Acta Tropica · doi:10.1016/s0001-706x(03)00118-9 · Cited by 12
Accuracy of an Enzymatic Assay Device for Sermn Ethanol Measurement
Keim, M. E., Keim, M. E., Bartfield, J. M., Raccio‐Robak, N., Abhyankar, V. V., & Salluzzo, R. F. (1999) · Journal of Toxicology Clinical Toxicology · doi:10.1081/clt-100102411 · Cited by 12
Rigalleau, V., Lasseur, C., Chauveau, P., Barthes, N., Raffaitin, C., Combe, C., Perlemoine, C., Baillet‐Blanco, L., & Gin, H. (2004) · Annals of Nutrition and Metabolism · doi:10.1159/000083573 · Cited by 14
Júnior, E. A., Passos, A. P., Bruns, R. F., Nardozza, L. M. M., & Moron, A. F. (2013) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.3109/14767058.2013.847419 · Cited by 12
Glencross, D. K., Scott, L. E., Aggett, H. M., Sonday, S., & Scott, C. S. (1999) · Clinical & Laboratory Haematology · doi:10.1046/j.1365-2257.1999.00276.x · Cited by 12
Leonard, I., Weitkamp, B., Jones, K., Aittomäki, J., & Myles, P. S. (2002) · Anaesthesia · doi:10.1046/j.1365-2044.2002.02606.x · Cited by 12
Repeatability and Effects of Sequential Measurements with POBF Tonograph
Davey, P. G., Watkins, R., Broadway, D. C., & O'Leary, D. J. (2004) · Optometry and Vision Science · doi:10.1002/j.1538-9235.2004.tb01965.x · Cited by 12
Quantification of mixed chimerism by real time PCR on whole blood-impregnated FTA cards
Pezzoli, N., Silvy, M., Woronko, A., Treut, T. L., Levy‐Mozziconacci, A., Reviron, D., Gabert, J. A., & Picard, C. (2006) · Leukemia Research · doi:10.1016/j.leukres.2006.09.004 · Cited by 12
Lawrence, J. C., Lee, H.-M., Kim, J., & Kim, E. (2009) · Nutrition Research · doi:10.1016/j.nutres.2009.10.017 · Cited by 13
Scharling, B., Nielsen, G. G., Klitgaard, T., Skovsted, T. A., Møss, J., Segel, S., & Larsen, L. F. (2007) · Blood Coagulation & Fibrinolysis · doi:10.1097/mbc.0b013e3282e7febb · Cited by 12
Measuring efficiency in Australian and New Zealand paediatric intensive care units
Straney, L. D., Clements, A., Alexander, J., & Slater, A. (2010) · Intensive Care Medicine · doi:10.1007/s00134-010-1916-3 · Cited by 12
Guermazi, M., Mezganni, M., Yahia, M., Poiraudeau, S., Fermanian, J., Elleuch, M. H., Revel, M., & Elleuch, M. H. (2004) · Annales de Réadaptation et de Médecine Physique · doi:10.1016/j.annrmp.2004.02.008 · Cited by 15
Can peak expiratory flow be measured accuratelyduring a forced vital capacity manoeuvre?
Wensley, D., Pickering, D., & Silverman, M. A. (2000) · European Respiratory Journal · doi:10.1034/j.1399-3003.2000.16d18.x · Cited by 12
Postural balance, isometric trunk muscle strength and low back symptoms among young adults
Paalanne, N. (2011) · Cited by 17
Humphries, L., Baldwin, K. M., Clark, K. L., Tenuta, V., & Brumley, K. (2012) · Clinical Nurse Specialist · doi:10.1097/nur.0b013e31826e3efb · Cited by 12
Inaccuracy of the Schwartz formula in estimating glomerular filtration rate in Nigerian children
Gbadegesin, R. A., Adeyemo, A., Asinobi, A. O., & Osinusi, K. (1997) · Annals of Tropical Paediatrics · doi:10.1080/02724936.1997.11747884 · Cited by 12
Posterior fossa meningiomas intimately involved with the endolymphatic sac.
Friedman, R. A., Nelson, R. A., & Harris, J. P. (1996) · PubMed · Cited by 13
Bateman, S. W., Mathews, K. A., Abrams‐Ogg, A. C. G., Lumsden, J. H., Johnstone, I. B., & Hillers, T. K. (1999) · Journal of the American Veterinary Medical Association · doi:10.2460/javma.1999.215.06.805 · Cited by 12
Worthley, S. G., Helft, G., Fayad, Z. A., Fuster, V., Rodriguez, O. J., Zaman, A., & Badimon, J. J. (2001) · International journal of cardiac imaging · doi:10.1023/a:1010688122184 · Cited by 12
Löf, M., Hannestad, U., & Forsum, E. (2002) · Food and Nutrition Bulletin · doi:10.1177/15648265020233s105 · Cited by 12
An Evaluation of the Methodology for the Assessment of Body Composition in Children and Adolescents
Hills, A. P., Lyell, L., & Byrne, N. M. (2000) · KARGER eBooks · doi:10.1159/000061764 · Cited by 19
Measurement of the viability of Lawsonia intracellularis.
Wattanaphansak, S., Gebhart, C. J., Olin, M. R., & Deen, J. (2005) · Europe PMC (PubMed Central) · Cited by 17
Seamark, D., Backhouse, S., Barber, P., Hichens, J., Lee, R., & Powell, R. J. (1997) · Journal of the Royal Society of Medicine · doi:10.1177/014107689709001206 · Cited by 12
Tonometry in the general practice setting (II):
Christoffersen, T., Holtedahl, K. A., Fors, T., & Ringberg, U. (1993) · Acta Ophthalmologica · doi:10.1111/j.1755-3768.1993.tb04971.x · Cited by 12
Peters, R. J. G., Kok, W. E., Pasterkamp, G., Birgelen, C. V., Prins, M., & Serruys, P. W. (2000) · European Heart Journal · doi:10.1053/euhj.1999.1853 · Cited by 13
Improved aortic distensibility after aortic homograft root replacement at long-term follow-up
Nemes, A., Galema, T. W., Soliman, O. I. I., Bogers, A. J. J. C., ten Cate, F. J., & Geleijnse, M. L. (2008) · International Journal of Cardiology · doi:10.1016/j.ijcard.2008.04.049 · Cited by 12
Calibration of a total body potassium monitor with an anthropomorphic phantom
Hansen, R. D., & Allen, B. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/015 · Cited by 12
Fieno, D. S., Thomson, L., Slomka, P. J., Abidov, A. A., Friedman, J. D., Germano, G., & Berman, D. S. (2007) · Journal of Nuclear Cardiology · doi:10.1016/j.nuclcard.2006.08.019 · Cited by 12
Pavlovic, C., Futamatsu, H., Angiolillo, D. J., Guzmán, L. A., Wilke, N. M., Siragusa, D. A., Wludyka, P. S., PERCY, R. F., Northrup, M., Bass, T. A., et al. (2006) · International journal of cardiac imaging · doi:10.1007/s10554-006-9133-4 · Cited by 12
Assessment of Spine Bone Mineral Density in Juvenile Idiopathic Arthritis: Impact of Scan Projection
Dubner, S. E., Shults, J., Leonard, M. B., Zemel, B. S., Sembhi, H., & Burnham, J. M. (2008) · Journal of Clinical Densitometry · doi:10.1016/j.jocd.2007.10.005 · Cited by 13
Smoking cessation advice provided in 53 Norwegian pharmacies
Granås, A. G., Haugli, A., & Horn, A. M. (2004) · International Journal of Pharmacy Practice · doi:10.1211/0022357044472 · Cited by 13
Occupational Epidemiology in Agriculture: A Case Study in the Southern African Context
London, L. (1998) · International Journal of Occupational and Environmental Health · doi:10.1179/oeh.1998.4.4.245 · Cited by 13
Reproducibility of the proximal flow convergence method in mitral and tricuspid regurgitation
Grossmann, G., Hoffmeister, A., Imhof, A., Giesler, M., Hombach, V., & Spieß, J. (2004) · American Heart Journal · doi:10.1016/j.ahj.2003.11.006 · Cited by 12
Tochikubo, O., Kawano, Y., Miyajima, E., & Ishii, M. (1997) · Journal of Hypertension · doi:10.1097/00004872-199715020-00005 · Cited by 12
Sarry, L., Boire, J. Y., Zanca, M., Lusson, J., & Cassagnes, J. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/8/006 · Cited by 12
Effects of method and MRI slice thickness on entorhinal cortex volumetry
Bonilha, L., Kobayashi, E., Cendes, F., & Li, L. M. (2003) · Neuroreport · doi:10.1097/00001756-200307180-00001 · Cited by 12
Kasa, N. A., & Heinonen, K. (1993) · Acta Paediatrica · doi:10.1111/j.1651-2227.1993.tb12504.x · Cited by 12
Doppler Cardiac Output and Left Ventricular Performance after Cardiac Surgery
Fratacci, M.-D., Payen, D. M., Béloucif, S., & Laborde, F. (1992) · CHEST Journal · doi:10.1378/chest.102.2.380 · Cited by 12
Mancini, P. M., & Vottero, L. R. (2005) · Journal of Physical Organic Chemistry · doi:10.1002/poc.993 · Cited by 12
Almendingen, K., Hofstad, B., & Vatn, M. H. (2002) · Scandinavian Journal of Gastroenterology · doi:10.1080/003655202753387400 · Cited by 12
Cardiac Output In Mice Overexpressing beta2-Adrenoceptors Or With Myocardial Infarct
Gao, X., Lambert, É., Dart, A. M., & Du, X. (2001) · Clinical and Experimental Pharmacology and Physiology · doi:10.1046/j.1440-1681.2001.03453.x · Cited by 12
Pretreatment blood pressure reliably predicts progression of chronic nephropathies
Ruggenenti, P., Perna, A., Lesti, M., Pisoni, R., Mosconi, L., Arnoldi, F., Ciocca, I., Gaspari, F., & Remuzzi, G. (2000) · Kidney International · doi:10.1046/j.1523-1755.2000.00382.x · Cited by 12
Worth, G. K., Vasikaran, S. D., Retallack, R. W., Musk, A. A., & Gutteridge, D. H. (2004) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1258/000456304322880050 · Cited by 12
Force generation capacity of knee extensor muscles in speed skaters
Kanehisa, H., Nemoto, I., Okuyama, H., Ikegawa, S., & Fukunaga, T. (1996) · European Journal of Applied Physiology · doi:10.1007/bf00357677 · Cited by 13
Comparison of Two Methods for Measuring Ultrasound Properties of the Heel in Postmenopausal Women
Ingle, B. M., Sherwood, K. E., & Eastell, R. (2001) · Osteoporosis International · doi:10.1007/s001980170096 · Cited by 12
Jernberg, T., Venge, P., & Lindahl, B. (2003) · Cardiology · doi:10.1159/000072389 · Cited by 12
Kelbæk, H., Aldershvile, J., Svendsen, J. H., Folke, K., Nielsen, S. L., & Munck, O. (1988) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(88)90209-4 · Cited by 12
Poets, C. F., Rau, G. A., Gappa, M., & Seidenberg, J. (1996) · Pediatric Research · doi:10.1203/00006450-199606000-00027 · Cited by 12
Croft, M. S., Desai, G., Seed, P. T., Pollard, J. I., & Perry, M. E. (1999) · Clinical Anatomy · doi:10.1002/(sici)1098-2353(1999)12:2 · Cited by 12
Harada, K., Tamura, M., Toyono, M., & Takada, G. (2001) · The American Journal of Cardiology · doi:10.1016/s0002-9149(01)01827-6 · Cited by 12
Gray, G., Shakerdi, L. A., & Wallace, A. (2003) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1258/000456303322326506 · Cited by 12
Validation of a handheld automated keratometer in adults
Noonan, C. P., Rao, P. G., Kaye, S. B., Green, J. R., & Chandna, A. (1998) · Journal of Cataract & Refractive Surgery · doi:10.1016/s0886-3350(98)80333-7 · Cited by 12
Beaupied, H., Chappard, C., Basillais, A., Lespessailles, É., & Benhamou, C. L. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/18/011 · Cited by 13
Nieminen, T. V. M., Kööbi, T., & Turjanmaa, V. (2000) · Clinical Physiology · doi:10.1046/j.1365-2281.2000.00288.x · Cited by 12
Dimitriou, T., Huesemann, S., Neubert, A., & Remer, T. (2001) · Hormone Research in Paediatrics · doi:10.1159/000048098 · Cited by 12
Ploidy pattern and cell cycle in breast cancer as detected by image analysis and flow cytometry
Luzi, P., Bruni, A., Mangiavacchi, P., Cevenini, G., Marini, D., & Tosi, P. (1994) · Cytometry · doi:10.1002/cyto.990180205 · Cited by 12
Ekman, L., Milsom, I., Arvidsson, S., Biber, B., Martinell, S., & Sjöqvist, B. A. (1990) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.1990.tb03068.x · Cited by 12
KELLER, C., Brimacombe, J. R., Agrò, F. E., & Margreiter, J. (2000) · Anesthesia & Analgesia · doi:10.1097/00000539-200002000-00037 · Cited by 14
QUIRK, P., Ward, L. C., Thomas, B. J., Holt, T. L., Shepherd, R. W., & Cornish, B. (1995) · Clinical Nutrition · doi:10.1016/s0261-5614(95)80052-2 · Cited by 12
Maggiore, U., Cristol, J., Canaud, B., Dupuy, A., Formica, M., Pozzato, M., Panichi, V., Consani, C., Metelli, M. R., Sereni, L., et al. (2005) · Journal of Laboratory and Clinical Medicine · doi:10.1016/j.lab.2005.03.002 · Cited by 16
Şahin, A., Salman, M. A., Salman, A. E., & Aypar, Ü. (2005) · Journal of Neurosurgical Anesthesiology · doi:10.1097/01.ana.0000158387.80678.bf · Cited by 12
Noninvasive Monitoring of Cardiac Output during Exercise by Inductance Cardiography
Kaplan, V., Bucklar, G., & Bloch, K. E. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000064997.58069.a6 · Cited by 12
D'Souza, R., Kotre, C. J., Owen, J. P., Keir, M. J., Ward, M., & Wilkinson, R. (1995) · British Journal of Radiology · doi:10.1259/0007-1285-68-806-130 · Cited by 12
Neumann, A., Soble, J. S., Anagnos, P. C., Kagzi, M., & Parrillo, J. E. (1998) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(98)70070-7 · Cited by 12
Assessment of Left Ventricular Viscoelastic Components Based on Ventricular Harmonic Behavior
Kheradvar, A., Milano, M., Gorman, R. C., Gorman, J. H., & Gharib, M. (2006) · Cardiovascular Engineering An International Journal · doi:10.1007/s10558-006-9001-9 · Cited by 13
Pulmonary impedance as an index of severity and mechanism of neonatal lung disease
Coates, A. L., Vallinis, P., Mullahoo, K., Seddon, P. C., & Davis, G. M. (1994) · Pediatric Pulmonology · doi:10.1002/ppul.1950170108 · Cited by 12
Marks, G. B., Kjellerby, Luczynska, & Burney, P. (1998) · Clinical & Experimental Allergy · doi:10.1046/j.1365-2222.1998.00409.x · Cited by 12
Mirandola, M., Baldassari, E., Beneduce, R., Italo, A., Segala, M., & Tansella, M. (2000) · International Journal of Methods in Psychiatric Research · doi:10.1002/mpr.82 · Cited by 12
Rota, S., Flynn, P. D., Wareham, N. J., Baglin, T. P., & Byrne, C. D. (1996) · Thrombosis Research · doi:10.1016/0049-3848(96)00141-7 · Cited by 12
Capillary and Venous Blood Glucose Measurements Using a Direct Glucose‐sensing Meter
Matthews, D. R., Burton, S., Bown, E. G., Chusney, G. D., Dornan, T., Gale, E., McKinnon, G., & Steemson, J. (1991) · Diabetic Medicine · doi:10.1111/j.1464-5491.1991.tb02128.x · Cited by 12
Nucleolar organizer regions in benign and malignant prostatic disease
LLOYD, S. N., JOHNSON, C. P., BROWN, I. L., & Kirk, D. (1991) · Histopathology · doi:10.1111/j.1365-2559.1991.tb00876.x · Cited by 12
Shiota, T., Jones, M., Aida, S., Chikada, M., Tsujino, H., Elkadi, T., & Sahn, D. J. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00210-7 · Cited by 12
Lactate concentration gradient from right atrium to pulmonary artery
Gutiérrez, G., Chawla, L. S., Seneff, M. G., Katz, N. M., & Zia, H. (2005) · Critical Care · doi:10.1186/cc3741 · Cited by 12
Buck, T., Mucci, R. A., Guerrero, J., Holmvang, G., Handschumacher, M. D., & Levine, R. A. (2000) · Proceedings of the IEEE · doi:10.1109/5.838068 · Cited by 12
Vanmolkot, F. H. M., der Schueren, B. V., & DEHOON, J. (2006) · Clinical Pharmacology & Therapeutics · doi:10.1016/j.clpt.2005.11.005 · Cited by 12
Chavasse, R. J. P. G., Bastian‐Lee, Y., & Seddon, P. C. (2001) · European Respiratory Journal · doi:10.1183/09031936.01.00018401 · Cited by 12
Eichler, W., Eisenbeiss, C., Schumacher, J. O., Klaus, S., Vogel, R., & Klotz, K.-F. (2000) · Journal of Applied Physiology · doi:10.1152/jappl.2000.89.1.359 · Cited by 12
Lung volume measurements in wheezy infants: comparison of plethysmography and gas dilution
Eber, E., Steinbrugger, B., Modl, M., Weinhandl, E., & Zach, M. (1994) · European Respiratory Journal · doi:10.1183/09031936.94.07111988 · Cited by 12
Bell, C., Swinburn, B. A., Amosa, H., Scragg, R. K. R., & Sharpe, S. J. (1999) · Asia Pacific Journal of Clinical Nutrition · doi:10.1046/j.1440-6047.1999.00089.x · Cited by 15
YOUNG, P. E., Beasley, N. J. P., HOUGHTON, D. J., Husband, D. J., Currie, M. G., CHISLETT, B., & Jones, A. S. (1998) · Clinical Otolaryngology · doi:10.1046/j.1365-2273.1998.2360528.x · Cited by 12
The quantification of pulmonary valve haemodynamics using MRI
Reid, S. A., Walker, P. G., Fisher, J., Nagy, Z., Ridgway, J. P., Watterson, K. G., & Sivananthan, M. U. (2002) · International journal of cardiac imaging · doi:10.1023/a:1014672223202 · Cited by 12
Godfrey, R., Whyte, G. P., McCarthy, J., Nevill, A. M., & Head, A. (2004) · British Journal of Sports Medicine · doi:10.1136/bjsm.2003.008714 · Cited by 12
Collie, D., DeBoer, D. J., Muggenburg, B. A., & Bice, D. E. (1997) · American Journal of Veterinary Research · doi:10.2460/ajvr.1997.58.01.34 · Cited by 12
Kreuk, A. M. D., Zevenbergen, A., Oostveen, J. W. V., Schuurhuis, G. J., Huijgens, P. C., & Jonkhoff, A. R. (2001) · Stem Cells and Development · doi:10.1089/152581601317210890 · Cited by 12
Assay Development, Evaluation, and Validation
Deshpande, S. S. (1996) · Springer eBooks · doi:10.1007/978-1-4613-1169-0_9 · Cited by 12
Constant, I., Laude, D., Elghozi, J., & Murat, I. (1999) · Journal of Clinical Monitoring and Computing · doi:10.1023/a:1009989130561 · Cited by 14
Yamamura, C., & Kashiwazaki, H. (2002) · The Japanese Journal of Nutrition and Dietetics · doi:10.5264/eiyogakuzashi.60.75 · Cited by 12
Reliability of Glucose Measurement Using the HemoCue Analyser in Hypoglycaemia
Young, R. P., Critchley, J., Lau, M. S. W., Lee, K. K. C., Robertshaw, A. M., Chan, T. Y. K., & Anderson, D. C. (1994) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/000456329403100610 · Cited by 12
Glycoconjugate Expression in Normal Human Inferior Turbinate Mucosa: A Lectin Histochemical Study
Berger, G., Kogan, T., Skutelsky, E., & Ophi, D. (2005) · American Journal of Rhinology · doi:10.1177/194589240501900117 · Cited by 12
Comparison of indirect methods to estimate plasma volume changes during hemodialysis
Kirschbaum, B. B. (1989) · The International Journal of Artificial Organs · doi:10.1177/039139888901200508 · Cited by 12
Accuracy of Pulse Oximetry in Patients with Hyperbilirubinemia
Chelluri, L., Snyder, J. V., & Bird, J. R. (1991) · Respiratory Care · doi:10.1177/194336549103601204 · Cited by 12
Potassium-Based Dilutional Method to Measure Hemodialysis access Recirculation
Brancaccio, D., Tessitore, N., Carpani, P., Gammaro, L., Losi, B., Zoni, U., Maschio, G., & Gallieni, M. A. (2001) · The International Journal of Artificial Organs · doi:10.1177/039139880102400902 · Cited by 12
Clinical Application of Cardiac Output During Ramp Exercise Calculated Using the Fick Equation
Yamabe, H., ltho, K., Yasaka, Y., & Yokoyama, M. (1997) · Japanese Circulation Journal-english Edition · doi:10.1253/jcj.61.488 · Cited by 12
Fluorometric determination of total retinyl esters in triglyceride-rich lipoproteins
Orth, M., Hanisch, M., Kröning, G., Özcürümez, M. K., Wieland, H., & Luley, C. H. (1998) · Clinical Chemistry · doi:10.1093/clinchem/44.7.1459 · Cited by 12
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.