STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 29,901–30,000 of 47,868
Larrahondo, B. F., Valencia, J. G., Martínez-Villalba, A. M. R., Ospina, J. P. Z., & Aguirre–Acevedo, D. C. (2021) · Revista Colombiana de Psiquiatría (English ed ) · doi:10.1016/j.rcpeng.2020.01.002 · Cited by 13
Chiea, R. A., Costa, M. H., & Cordioli, J. A. (2021) · IEEE/ACM Transactions on Audio Speech and Language Processing · doi:10.1109/taslp.2021.3076363 · Cited by 13
A Tool to Locate Parathyroid Glands Using Dynamic Optical Contrast Imaging
Hu, Y., Han, A. Y., Huang, S., Pellionisz, P. A., Alhiyari, Y. M., Krane, J. F., Shori, R. K., Stafsudd, O. M., & John, M. A. S. (2021) · The Laryngoscope · doi:10.1002/lary.29633 · Cited by 10
Чипига, Л. А., Golikov, V. Y., Водоватов, А. В., & Bernhardsson, C. (2021) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncab086 · Cited by 10
Grou, T. C., de Castro, S. S., Leite, C. F., Carvalho, M. T., & Patrizzi, L. J. (2021) · Fisioterapia e Pesquisa · doi:10.1590/1809-2950/20024628012021 · Cited by 19
Jasinovic, T., Burma, J. S., Cameron, B., Lun, V. M. Y., van Rassel, C. R., Sutter, B., Wiley, J. P., & Schneider, K. (2021) · Physical Therapy in Sport · doi:10.1016/j.ptsp.2021.06.008 · Cited by 10
Prognostic value of a modified Immunosocre in patients with stage I−III resectable colon cancer
Zhao, K., Wu, X., Li, Z., Wang, Y., Xu, Z., Li, Y., Wu, L., Yao, S., Huang, Y., Liang, C., et al. (2021) · Chinese Journal of Cancer Research · doi:10.21147/j.issn.1000-9604.2021.03.09 · Cited by 12
Emmenegger, T. M., Dávid, G., Ashtarayeh, M., Fritz, F. J., Ellerbrock, I., Helms, G., Balteau, E., Freund, P., & Mohammadi, S. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.674719 · Cited by 10
Briggs, E. V., & Mazzà, C. (2021) · PLoS ONE · doi:10.1371/journal.pone.0254813 · Cited by 10
Huelin, F. J., Sales‐Sanz, M., Ye‐Zhu, C., Cruz, A. A. V. E., Muñoz-Negrete, F. J., & Rebolleda, G. (2021) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2021-319666 · Cited by 10
Young, G., Krastins, D., Chang, D., Lam, J. H., Quah, J. X., Stanton, T., Russell, F. D., Greaves, K., Kriel, Y., & Askew, C. D. (2021) · Heart Lung and Circulation · doi:10.1016/j.hlc.2021.07.004 · Cited by 10
Singh, S., Rutkowski, P. S., Dyachkov, A., Iyer, V., Pourafkari, L., & Nader, N. D. (2021) · Journal of Cardiovascular and Thoracic Research · doi:10.34172/jcvtr.2021.39 · Cited by 12
Cutuli, S. L., Osawa, E., Eyeington, C. T., Proimos, H., Canet, E., Young, H., Peck, L., Eastwood, G. M., Glassford, N. J., Bailey, M., et al. (2021) · Critical Care and Resuscitation · doi:10.51893/2021.3.oa12 · Cited by 17
Ouattara, M., Tamboura, M., Kambiré, D., Lê, K. A., Phan, T. V., Srinivasan, V., Nguyen, H. A. T., Trang, D. V. T., Lessa, F. C., Iijima, M., et al. (2021) · The Journal of Infectious Diseases · doi:10.1093/infdis/jiab056 · Cited by 11
Direct comparison of the reproducibility of in-office and self-measured home blood pressures
Asayama, K., Ohkubo, T., Rakugi, H., Miyakawa, M., Mori, H., Katsuya, T., Ikehara, Y., Ueda, S., Ohya, Y., Tsuchihashi, T., et al. (2021) · Journal of Hypertension · doi:10.1097/hjh.0000000000003026 · Cited by 10
Gait event detection using kinematic data in children with bilateral spastic cerebral palsy
Gómez-Pérez, C., Martori, J. C., Puig-Diví, A., Medina-Casanovas, J., Vidal, J., & Font-Llagunes, J. M. (2021) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2021.105492 · Cited by 14
Reusable flexible dry electrodes for biomedical wearable devices
Raho, R., Scarpa, E., D’Angelo, A. N., Desmaële, D., Raheli, F., Qualtieri, A., Rizzi, F., & Vittorio, M. D. (2021) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2021.113157 · Cited by 10
Berg, J., Jablonowski, R., Mohammad, M. A., Solem, K., Borgquist, R., Ostenfeld, E., Arheden, H., & Carlsson, M. (2021) · Scientific Reports · doi:10.1038/s41598-021-99613-1 · Cited by 10
Validation and accuracy evaluation of automatic segmentation for knee joint pre-planning
Bori, E., Pancani, S., Vigliotta, S., & Innocenti, B. (2021) · The Knee · doi:10.1016/j.knee.2021.10.016 · Cited by 10
Drljevic-Nielsen, A., Donskov, F. N., Mains, J. R., Andersen, M. B., Thorup, K., Thygesen, J., & Rasmussen, F. (2021) · American Journal of Roentgenology · doi:10.2214/ajr.21.26911 · Cited by 11
Improving non-invasive hemoglobin measurement accuracy using nonparametric models
Man, J., Zielinski, M. D., Das, D., Wutthisirisart, P., & Pasupathy, K. S. (2021) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2021.103975 · Cited by 10
Data Mining in Employee Healthcare Detection Using Intelligence Techniques for Industry Development
Mehbodniya, A., Khan, I. R., Chakraborty, S., Karthik, M. V., Mehta, K., Ali, L., & Nuagah, S. J. (2022) · Journal of Healthcare Engineering · doi:10.1155/2022/6462657 · Cited by 12
RetractedNaranjo, J., Furlano, M. M., Torres, F., Hernández-Mancera, J., Pybus, M., Ejarque, L., Herrera, C. C., Guirado, L., Ars, E., & Torrá, R. (2021) · Clinical Kidney Journal · doi:10.1093/ckj/sfab293 · Cited by 10
Lim, S., & Xin, L. (2022) · NMR in Biomedicine · doi:10.1002/nbm.4706 · Cited by 10
Ashena, Z., Gallagher, S., Naveed, H., Spalton, D. J., & Nanavaty, M. A. (2022) · Vision · doi:10.3390/vision6010018 · Cited by 10
Tran, D., Kamaladasa, Y., Muñoz, P. A., Kotchetkova, I., D'Souza, M. I., Celermajer, D. S., Maiorana, A., & Cordina, R. (2022) · International Journal of Cardiology Congenital Heart Disease · doi:10.1016/j.ijcchd.2022.100362 · Cited by 13
Multichannel recording of tibial-nerve somatosensory evoked potentials
van de Wassenberg, W. J. G., Kruizinga, W. J., van der Hoeven, J. H., Leenders, K. L., & Maurits, N. M. (2008) · Neurophysiologie Clinique · doi:10.1016/j.neucli.2008.07.002 · Cited by 11
Comparison of hand dynamometers in elderly people
Guerra, R. S., & do Amaral, T. F. (2009) · The journal of nutrition health & aging · doi:10.1007/s12603-009-0116-8 · Cited by 11
Twohig, H., Mitchell, C. A., Mallen, C. D., & Müller, S. (2022) · Rheumatology · doi:10.1093/rheumatology/keac317 · Cited by 10
González-Arellanes, R., Urquídez-Romero, R., Rodríguez‐Tadeo, A., Esparza‐Romero, J., Estrada, R. O. M., Ramírez‐López, E., Robles-Sardín, A. E., Pacheco, B. I., & Alemán-Mateo, H. (2022) · European Journal of Clinical Nutrition · doi:10.1038/s41430-022-01171-w · Cited by 11
Khalil, R. B., Sultan, A., Sénèque, M., Richa, S., Lefebvre, P., Renard, É., Courtet, P., Maïmoun, L., & Guillaume, S. (2022) · Nutrients · doi:10.3390/nu14132727 · Cited by 11
Coleman, J., Ginsburg, A. S., Macharia, W., Ochieng, R., Chomba, D., Zhou, G., Dunsmuir, D. T., Xu, S., & Ansermino, J. M. (2022) · PLoS ONE · doi:10.1371/journal.pone.0267026 · Cited by 10
Shaif, N. A. S., Doshi, K., & Lim, J. (2022) · Journal of Sleep Research · doi:10.1111/jsr.13700 · Cited by 10
AI-Enabled Assessment of Cardiac Systolic and Diastolic Function from Echocardiography
Anton, E. P., Ruijsink, B., Sidhu, B. S., Gould, J., Porter, B., Elliott, M. K., Mehta, V. S., Gu, H., Rinaldi, C. A., Cowie, M., et al. (2022) · Lecture notes in computer science · doi:10.1007/978-3-031-16902-1_8 · Cited by 10
Piccirillo, G., Moscucci, F., Corrao, A., Carnovale, M., Diego, I. D., Lospinuso, I., Caltabiano, C., Mezzadri, M., Rossi, P., & Magrì, D. (2022) · Biomedicines · doi:10.3390/biomedicines10102407 · Cited by 10
Computational thermochemistry of oxygenated polycyclic aromatic hydrocarbons and relevant radicals
Wang, T., Yalamanchi, K. K., Bai, X., Liu, S., Li, Y., Qu, B., Kukkadapu, G., & Sarathy, S. M. (2022) · Combustion and Flame · doi:10.1016/j.combustflame.2022.112484 · Cited by 10
Rum, L., Sciarra, T., Balletti, N., Lazich, A., & Bergamini, E. (2022) · Sensors · doi:10.3390/s22249904 · Cited by 11
Zwagemaker, A., Kloosterman, F. R., Gouw, S. C., Boyce, S., Brons, P., Cnossen, M. H., Collins, P. W., Eikenboom, J. C. J., Hay, C. R. M., Hengeveld, R. C. C., et al. (2023) · Journal of Thrombosis and Haemostasis · doi:10.1016/j.jtha.2022.11.040 · Cited by 10
Soh, Z. D., Jiang, Y., Ganesan, S. S. S. O., Zhou, M., Nongiur, M., Majithia, S., Tham, Y. C., Rim, T. H., Qian, C., Koh, V., et al. (2023) · PLOS Digital Health · doi:10.1371/journal.pdig.0000193 · Cited by 12
Yoshida, A., Ishikawa‐Takata, K., Tanaka, S., Suzuki, N., Nakae, S., Murata, H., Taguchi, M., & Higuchi, M. (2018) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000002205 · Cited by 10
Mariani, M., Colombo, F., Assennato, S. M., Frugoni, C., Cattaneo, A., Trombetta, E., Rebulla, P., & Porretti, L. (2014) · Europe PMC (PubMed Central) · doi:10.2450/2014.0198-13 · Cited by 10
Turner, L., Kelly, B., Boyland, E. J., & Bauman, A. E. (2015) · PLoS ONE · doi:10.1371/journal.pone.0133972 · Cited by 11
6-Min walk-test data in healthy North-African subjects aged 16–40years
Bourahli, M.-K., Bougrida, M., Martani, M., Mehdioui, H., & Saad, H. B. (2015) · Egyptian Journal of Chest Diseases and Tuberculosis · doi:10.1016/j.ejcdt.2015.08.003 · Cited by 18
Hirano, M., & Katoh, M. (2015) · Journal of Physical Therapy Science · doi:10.1589/jpts.27.2125 · Cited by 10
Vyas, K. J., Danz, D., Gilman, R. H., Wise, R. A., Lèon‐Velarde, F., Miranda, J. J., & Checkley, W. (2015) · High Altitude Medicine & Biology · doi:10.1089/ham.2015.0026 · Cited by 10
Knapp, S., Awwad, S. T., Ghali, C., & McCulley, J. P. (2009) · Journal of Refractive Surgery · doi:10.3928/1081597x-20090201-05 · Cited by 10
Computer-assisted navigation for the assessment of fixed flexion in knee arthroplasty.
Gallie, P., Davis, E. T., Macgroarty, K., Waddell, J. P., & Schemitsch, E. H. (2010) · PubMed Central · Cited by 10
Wu, S. F., Courtney, M. D., Edwards, H. E., McDowell, J., Shortridge‐Baggett, L. M., & Chang, P. (2008) · Journal of the Formosan Medical Association · doi:10.1016/s0929-6646(08)60141-2 · Cited by 12
Owen, J. L., Stephens, D., & Wright, J. G. (2007) · PubMed Central · Cited by 10
Nikolaidis, P. Τ., Padulo, J., Chtourou, H., Torres‐Luque, G., Afonso, J. R., & Heller, J. (2015) · Human Movement · doi:10.1515/humo-2015-0007 · Cited by 12
Constancy of the Orbscan acoustic factor to detect contact lens‐induced corneal swelling
Martín, R., Nunez, L. A. O., Sastre, J., de Juan, V., & Rodríguez, G. (2011) · Clinical and Experimental Optometry · doi:10.1111/j.1444-0938.2010.00578.x · Cited by 10
Bank, A. J., Burns, K. V., Kelly, A. S., Thelen, A. M., Kaufman, C. L., & Adler, S. W. (2008) · Clinical medicine Cardiology · doi:10.4137/cmc.s515 · Cited by 10
Gómez, A. J., Gómez, R. G., Alfayate, R. C., Fernández, C. D. L. R., Fernández-Rozas, S., & Pérez, M. M. G. (2000) · Archivos de Bronconeumología · doi:10.1016/s0300-2896(15)30226-x · Cited by 10
Polar S810 como recurso alternativo ao eletrocardiograma no teste de exercício de 4 segundos
Pimentel, A. S., Alves, E. D. S., Alvim, R. D. O., Nunes, R. T., Costa, C. M. A., Lovisi, J. C. M., & de Lima, J. R. P. (2010) · Arquivos Brasileiros de Cardiologia · doi:10.1590/s0066-782x2010005000037 · Cited by 11
Montuschi, P. (2013) · Elsevier eBooks · doi:10.1016/b978-0-44-462613-4.00019-2 · Cited by 12
ELISPOT Assay for Measurement of Antigen‐Specific and Polyclonal Antibody Responses
Lycke, N. Y., & Coico, R. (2015) · Current Protocols in Immunology · doi:10.1002/0471142735.im0714s108 · Cited by 10
Gourcerol, G., Vérin, É., Leroi, A., & Ducrotte, P. R. (2013) · Diseases of the Esophagus · doi:10.1111/dote.12161 · Cited by 10
Middione, M. J., Wu, H. H., & Ennis, D. B. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25059 · Cited by 10
Kim, E., & Ehrmann, K. (2012) · Clinical and Experimental Optometry · doi:10.1111/j.1444-0938.2012.00724.x · Cited by 10
Pinero, D. P., Camps, V. J., Ramón, M. L., Mateo, V., & Pérez-Cambrodí, R. J. (2015) · PubMed Central · doi:10.3980/j.issn.2222-3959.2015.03.12 · Cited by 10
Park, S., Hong, S. J., Park, J. H., Lim, S. Y., Ahn, C., Lim, D., & Shim, W. (2010) · Echocardiography · doi:10.1111/j.1540-8175.2010.01178.x · Cited by 10
Estimating a bivariate linear relationship
Leonard, D. (2011) · Bayesian Analysis · doi:10.1214/11-ba627 · Cited by 11
Health and Utilities in Patients With Gout Under the Care of a Rheumatologist
Spaetgens, B., Tran‐Duy, A., Wijnands, J. M. A., van der Linden, S., & Boonen, A. E. R. C. H. (2015) · Arthritis Care & Research · doi:10.1002/acr.22551 · Cited by 10
Caulkett, N., Duke, T., & Bailey, J. (1994) · PubMed Central · Cited by 10
Statistical measures of clinical agreement.
Jeyaseelan, L., & Rao, P. S. (1992) · PubMed · Cited by 10
Wickramasinghe, P., Laabadusuriya, S. P., Cleghorn, G. J., & Davies, P. S. W. (2010) · The Indian Journal of Pediatrics · doi:10.1007/s12098-009-0333-5 · Cited by 10
Sohns, J. M. S., Kowallick, J. T., Joseph, A. A., Merboldt, K. D., Voit, D., Faßhauer, M., Staab, W., Frahm, J., Lotz, J., & Unterberg‐Buchwald, C. (2015) · Europe PMC (PubMed Central) · doi:10.3978/j.issn.2223-4292.2015.08.08 · Cited by 10
Ferrero, B., Aimo, G., Pagni, R., Bergamasco, B., Bongioanni, M. R., Bergamini, L., & Durelli, L. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.5.824 · Cited by 10
Validation of a New Whole Blood Coagulation Monitoring System
Jaryno, S. A., Bennett, K., Loder, C., Zucker, M. L., Pan, C.-M., & LaDuca, F. M. (2002) · Journal of ExtraCorporeal Technology · doi:10.1051/ject/2002344271 · Cited by 10
Borai, A., Bahijri, S., Livingstone, C., Nawajha, M., Bawazeer, A., Baarmah, Z., Shanaa, A., Kadam, I., & Abdelaal, M. (2014) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.21805 · Cited by 10
Stensrud, T., & Carlsen, K. ‐. (2007) · The Clinical Respiratory Journal · doi:10.1111/j.1752-699x.2007.00030.x · Cited by 10
Quantitative analysis of three-dimensional tubular tree structures
Palágyi, K., Tschirren, J., & Milan Sonka, A. (2003) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.481127 · Cited by 10
Validation of keratometric measurements obtained with a new integrated aberrometry-topography system
Shneor, E., Millodot, M., Zyroff, M., & Gordon‐Shaag, A. (2012) · Journal of Optometry · doi:10.1016/j.optom.2012.03.003 · Cited by 10
Functional capacity after pediatric liver transplantation: A pilot study
da Silva, R. M., de Carvalho, W. B., Johnston, C., de Castro, M. B., Ferreira, I. M., Patti, C. L., de Azevedo, R. A., Gonzalez, A. M., Linhares, M. M., & Netto, A. A. S. (2014) · Pediatric Transplantation · doi:10.1111/petr.12318 · Cited by 10
Lamb, E. J., Browne, M., John, W. G., & Price, C. P. (1998) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/000456329803500117 · Cited by 10
Murley, D., Rees, S. E., Rasmussen, B. S., & Andreassen, S. (2004) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2004.07.012 · Cited by 10
Kılıçkap, M., Turhan, S., Sayın, T., Nergızoğlu, G., Kutlay, S., Duman, N., Rahimov, Ü., Kumbasar, D., Akgun, G. A., & Erol, Ç. (2007) · Canadian Journal of Cardiology · doi:10.1016/s0828-282x(07)70748-1 · Cited by 10
Repeatability of Respiratory Exchange Ratio Time Series Analysis
Nelson, M. T., Biltz, G. R., & Dengel, D. R. (2015) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000000924 · Cited by 13
Prediletto, R., Fornai, E., Catapano, G. A., & Carli, C. (2007) · BMC Pulmonary Medicine · doi:10.1186/1471-2466-7-18 · Cited by 10
the PIPARI study group, Saunavaara, V., Paavilainen, T., Hurme, S. A. M., Komu, M. E. S., & Parkkola, R. K. (2011) · Pediatric Radiology · doi:10.1007/s00247-011-2234-9 · Cited by 10
Assessment of Transcutaneous Bilirubinometry in Hospitalized Adults
Harbrecht, B. G., Rosengart, M. R., Bukauskas, K., Zenati, M. S., Marsh, J. W., & Geller, D. A. (2008) · Journal of the American College of Surgeons · doi:10.1016/j.jamcollsurg.2008.01.014 · Cited by 10
Incidence and outcome of scoliosis in children with pleural infection
Mukherjee, S., Langroudi, B., Rosenthal, M., & Balfour-Lynn, I. M. (2007) · Pediatric Pulmonology · doi:10.1002/ppul.20555 · Cited by 10
Counting respiratory rate in infants under 2 months: comparison between observation and auscultation
Singhi, S. C., Bhalla, A., Bhandari, A., & Narang, A. (2003) · Annals of Tropical Paediatrics · doi:10.1179/027249303235002206 · Cited by 10
Wimpress, S. P., Vara, D. D., & Brightling, C. E. (2005) · Chronic Respiratory Disease · doi:10.1191/1479972305cd052oa · Cited by 10
Cheng, S., Nicholson, P., Kröger, H., Alén, M., & Tylavsky, F. A. (2005) · Journal of Clinical Densitometry · doi:10.1385/jcd:8:1:065 · Cited by 10
Bryan, S. N., & Katzmarzyk, P. T. (2009) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/h09-054 · Cited by 10
Braam, R. L., de Maat, C., & Thien, T. A. (2002) · Blood Pressure Monitoring · doi:10.1097/00126097-200206000-00007 · Cited by 10
Aide, N., Louis, M.-H., Dutoit, S., Labiche, A., Lemoisson, E., Briand, M., Nataf, V., Poulain, L., Gauduchon, P., Talbot, J., et al. (2007) · Nuclear Medicine Communications · doi:10.1097/mnm.0b013e32822a0f37 · Cited by 10
Ahn, S. S., & Kim, E. Y. (2012) · European Radiology · doi:10.1007/s00330-012-2518-y · Cited by 10
Marzouki, H., Farhani, Z., Gmada, N., Tabka, Z., Shephard, R. J., & Bouhlel, E. (2014) · Science & Sports · doi:10.1016/j.scispo.2014.07.013 · Cited by 10
Deague, J. A., WILSON, C. M., Grigg, L., & Harrap, S. B. (1999) · Clinical Science · doi:10.1042/cs0970377 · Cited by 10
Extending the Range of Treadmill Testing for Patients with Intermittent Claudication
Nicolaï, S. P., Leffers, P., Kruidenier, L. M., de Bie, R. A., Prins, M. H., & Teijink, J. A. W. (2010) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181bcd96a · Cited by 10
Evaluation of the ADVIA® Centaur™ TSH-3 Assay
Vogeser, M., Weigand, M., Fraunberger, P., Fischer, H., & Cremer, P. (2000) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2000.048 · Cited by 10
Good accuracy of ultrasound estimations of fetal weight performed by midwives
Mattsson, N. K., Rosendahl, H., & Luukkaala, T. H. (2007) · Acta Obstetricia Et Gynecologica Scandinavica · doi:10.1080/00016340701322119 · Cited by 13
Use of electrocardiogram (ECG) electrodes for Bioelectrical Impedance Analysis (BIA)
Caicedo-Eraso, J. C., González-Correa, C. H., & González-Correa, C.-A. (2012) · Journal of Physics Conference Series · doi:10.1088/1742-6596/407/1/012008 · Cited by 12
Abi-Nader, K. N., Mehta, V., Wigley, V., Filippi, E., Tezcan, B., Boyd, M. B., Peebles, D., & David, A. L. (2009) · Reproductive Sciences · doi:10.1177/1933719109344772 · Cited by 10
Devlieger, R., Gratacós, E., Wu, J., Yeşildağlar, N., Ghysel, C., Barki, G., & Deprest, J. A. (2000) · Fetal Diagnosis and Therapy · doi:10.1159/000020990 · Cited by 10
Simplified parametric methods for [18F]FDDNP studies
Yaqub, M. M., Tolboom, N., van Berckel, B. N. M., Scheltens, P., Lammertsma, A. A., & Boellaard, R. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.07.046 · Cited by 10
Jaroni, J., Meier, R., Beer, A. J., Herrmann, K., Settles, M., Rummeny, E. J., & Huber, A. M. A. (2013) · Academic Radiology · doi:10.1016/j.acra.2013.03.012 · Cited by 10
Skrabal, F., Pichler, G. P., Gratze, G., & Holler, A. E. (2014) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2014.03.015 · Cited by 10
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.