STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 29,801–29,900 of 47,868
Palme, D. L. E., Johannsen, T. H., Petersen, J. H., Skakkebæk, N. E., Juul, A., Jørgensen, N., & Almstrup, K. (2017) · Clinica Chimica Acta · doi:10.1016/j.cca.2017.02.014 · Cited by 10
Lambrick, D., Jakeman, J., Grigg, R., Kaufmann, S., & Faulkner, J. (2017) · Biology of Sport · doi:10.5114/biolsport.2017.63734 · Cited by 9
Validation of the Mini-OAKHQOL for use in patients with osteoarthritis in Spain
González, M., Bilbao, A., Herrera-Espiñeira, C., García‐Pérez, L., Sarasqueta, C., & Escobar, A. (2017) · Clinical Rheumatology · doi:10.1007/s10067-017-3611-z · Cited by 10
Mwanza, J.-C., Grover, D. S., Budenz, D. L., Herndon, L. W., Nolan, W. P., Vos, J. W.-D., Hay-Smith, G., Bandi, J., Bhansali, K. A., Forbes, L. A., et al. (2017) · Eye · doi:10.1038/eye.2017.50 · Cited by 10
Aguilera‐Olivares, D., Palma‐Onetto, V., Flores‐Prado, L., Zapata, V., & Niemeyer, H. M. (2017) · Entomologia Experimentalis et Applicata · doi:10.1111/eea.12557 · Cited by 10
Jacobs, A., Benraad, C. E. M., Wetzels, J. F. M., Rikkert, M. G. M. O., & Kramers, C. (2017) · Drugs & Aging · doi:10.1007/s40266-017-0460-z · Cited by 11
Lancia, L., Toccaceli, A., Petrucci, C., Romano, S., & Penco, M. (2017) · Clinical Nursing Research · doi:10.1177/1054773817704653 · Cited by 10
Dobras cutâneas e bioimpedância elétrica perna-perna na avaliação da composição corporal de crianças
Cocetti, M., Castilho, S. D., & Filho, A. D. A. B. (2009) · Revista de Nutrição · doi:10.1590/s1415-52732009000400008 · Cited by 10
Talal, A. H., Chen, Y., Zeremski, M., Zavala, R., Sylvester, C., Kuhns, M. C., Brown, L. S., Markatou, M., & Cloherty, G. (2017) · Journal of Substance Abuse Treatment · doi:10.1016/j.jsat.2017.04.011 · Cited by 10
Kuetting, D. L. R., Dabir, D., Luetkens, J. A., Feißt, A., Homsi, R., Thomas, D., Schild, H. H., & Sprinkart, A. M. (2017) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25728 · Cited by 10
Body mass-to-waist ratio strongly correlates with skeletal muscle volume in children
Ohta, M., Midorikawa, T., Hikihara, Y., Sakamoto, S., Kawakami, Y., Fukunaga, T., & Kanehisa, H. (2017) · PLoS ONE · doi:10.1371/journal.pone.0177155 · Cited by 10
Hedström, E., Ishida, M., Sepúlveda-Martínez, Á., Ryd, D., Sperling, J., Engblom, H., & Nagel, E. C. (2017) · BMC Medical Imaging · doi:10.1186/s12880-017-0197-5 · Cited by 11
Platt, M. J., Huber, J. S., Brunt, K. R., & Simpson, J. A. (2017) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2017.02.008 · Cited by 10
Using lactate threshold to predict 5-km treadmill running performance in veteran athletes
Forsyth, J. J., Burt, D., Ridley, F., & Mann, C. (2017) · Biology of Sport · doi:10.5114/biolsport.2017.65999 · Cited by 11
Haque, S., Sandler, J., Cobourne, M. T., Bassett, P., & DiBiase, A. T. (2017) · Journal of Orthodontics · doi:10.1080/14653125.2017.1333248 · Cited by 10
Ahmed, A. I., Aldhaheri, S. R., Rodriguez‐Kovacs, J., Narasimhulu, D. M., Putra, M., MINKOFF, H. L., & Haberman, S. (2017) · Journal of Ultrasound in Medicine · doi:10.1002/jum.14253 · Cited by 11
Utility of new-generation pacemakers in sleep apnea screening
Dias, M., Gonçalves, I., Amann, B. V., Marques, P., Martinho, C., Leitão, C., Basto, R. P., de Sousa, J., Pinto, P., & Bárbara, C. (2017) · Sleep Medicine · doi:10.1016/j.sleep.2017.06.006 · Cited by 10
Tao, S., Ciuffo, L., Lima, J. A. C., Wu, K. C., & Ashikaga, H. (2017) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2017.06.003 · Cited by 12
Reischauer, C., Patzwahl, R., Koh, D., Froehlich, J. M., & Gutzeit, A. (2017) · Scientific Reports · doi:10.1038/s41598-017-06246-4 · Cited by 10
López-Sánchez, M., Mansilla-Plaza, L., & de la Orden, M. S. (2017) · Journal of Applied Geophysics · doi:10.1016/j.jappgeo.2017.07.011 · Cited by 10
Transcultural adaptation and validation of Hindi version of Quebec Back Pain Disability Scale
Zaidi, S., Verma, S., Moiz, J. A., & Hussain, M. E. (2017) · Disability and Rehabilitation · doi:10.1080/09638288.2017.1362596 · Cited by 10
Encouraging Critical Clinical Thinking (CCT) Skills in First-Year Veterinary Students
Ferguson, D. C., McNeil, L. K., Schaeffe, D. J., & Mills, E. M. (2017) · Journal of Veterinary Medical Education · doi:10.3138/jvme.0216-032r1 · Cited by 11
Reproducibility of the Pleth Variability Index in premature infants
den Boogert, W. J., van Elteren, H. A., Goos, T. G., Reiss, I. K. M., de Jonge, R. C. J., & van den Berg, V. J. (2017) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-017-0058-3 · Cited by 10
Three-dimensional segmentation of breast masses from digital breast tomosynthesis images
Pöhlmann, S. T. L., Lim, Y. Y., Harkness, E. F., Pritchard, S., Taylor, C., & Astley, S. (2017) · Journal of medical imaging · doi:10.1117/1.jmi.4.3.034007 · Cited by 10
Three-camera setup to record simultaneously standardized high-definition video for smile analysis
Husain, A., Makhija, P. G., Ummer, A. A., Kuijpers‐Jagtman, A. M., & Kuijpers, M. A. R. (2017) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2017.05.020 · Cited by 10
Solinski, A., Klusmeier, E., Horst, J.-P., Körperich, H., Haas, N. A., Kececioglu, D., & Laser, K. T. (2017) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2017.09.011 · Cited by 12
Mijuskovic, M., Gebistorf, M., Pandis, N., Renkema, A. M., & Fudalej, P. S. (2017) · European Journal of Orthodontics · doi:10.1093/ejo/cjx083 · Cited by 10
Elliott, T. G., Dooley, K., Zhang, M., Campbell, H., & Thompson, D. J. S. (2017) · Canadian Journal of Diabetes · doi:10.1016/j.jcjd.2017.10.053 · Cited by 12
Cardiac gating using scattering of an 8‐channel parallel transmit coil at 7T
Jaeschke, S. H. F., Robson, M. D., & Hess, A. T. (2017) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27038 · Cited by 10
James, C., Vallejo, F. T., Kantebeen, M., & Farra, S. D. (2018) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000002465 · Cited by 12
Kim, D. H., Yoo, J.-Y., Kim, J. Y., Ahn, S.-H., Kim, S., & Min, S. K. (2018) · Korean Journal of Anesthesiology · doi:10.4097/kja.d.18.27154 · Cited by 10
Gurovich, A. N., Heiser, B., Hayes, C., Marshall, E., Roath, S., & Kabous, N. G. (2018) · Cardiopulmonary Physical Therapy Journal · doi:10.1097/cpt.0000000000000082 · Cited by 11
Chen, X., Li, Q., Qi, S., Zhang, H., Chen, S., & Wang, T. (2015) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2015.04.016 · Cited by 10
Borges, M. K., Jacinto, A. F., & Cítero, V. A. (2018) · Dementia & Neuropsychologia · doi:10.1590/1980-57642018dn12-030003 · Cited by 11
Doğukan, F. M., Özgüven, B. Y., Doğukan, R., & Kabukçuoğlu, F. (2018) · Endocrine Pathology · doi:10.1007/s12022-018-9554-3 · Cited by 10
D’Sa, L., Senaratne, N., Woodcock-Smith, J., Miles, K. L., Wilkinson, I. B., & McEniery, C. M. (2018) · Hypertension Research · doi:10.1038/s41440-018-0120-7 · Cited by 10
Dastoori, M., Bouserhal, J. P., Halazonetis, D. J., & Athanasiou, A. E. (2018) · Journal of Clinical and Experimental Dentistry · doi:10.4317/jced.55180 · Cited by 10
Adami, C., Lardone, E., & Monticelli, P. (2018) · Journal of Feline Medicine and Surgery · doi:10.1177/1098612x18813426 · Cited by 10
Delshad, M., Beck, K. L., von Hurst, P. R., Mugridge, O., & Conlon, C. A. (2019) · Maternal and Child Nutrition · doi:10.1111/mcn.12758 · Cited by 11
Recognition acuity in children measured using The Auckland Optotypes
Hamm, L. M., Anstice, N. S., Black, J. M., & Dakin, S. C. (2018) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12590 · Cited by 10
Comparison of the Polar V800 and the Garmin Forerunner 230 to Predict V̇o 2max
Snyder, N. C., Willoughby, C. A., & SMITH, B. K. (2019) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000002931 · Cited by 14
Comparison of defect depths for sinusoidal and circular perimetric stimuli in patients with glaucoma
Swanson, W. H., & King, B. J. (2019) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12598 · Cited by 10
de la Rosa, E., Sidibé, D., Decourselle, T., Leclercq, T., Cochet, A., & Lalande, A. (2021) · Algorithms · doi:10.3390/a14080249 · Cited by 25
Poulsen, M. K., Thomsen, L. P., Kjærgaard, S., Rees, S. E., & Karbing, D. S. (2019) · Nutrition in Clinical Practice · doi:10.1002/ncp.10250 · Cited by 11
Development and validation of a high-speed video system for measuring saccadic eye movement
Brooks, J. S., Smith, W. J., Webb, B., Heath, M. D., & Dickey, J. P. (2019) · Behavior Research Methods · doi:10.3758/s13428-019-01197-2 · Cited by 12
Zhou, S., Luo, L. Q., Li, J., Lin, M., Chen, L., Shao, J., Lu, S., Ma, Y., Zhang, Y., Wenfen, C., et al. (2019) · Radiation Oncology · doi:10.1186/s13014-019-1217-0 · Cited by 10
Júdice, P. B., Teixeira, L., Silva, A. M., & Sardinha, L. B. (2019) · Journal of Sports Sciences · doi:10.1080/02640414.2019.1586281 · Cited by 13
Olin, A. B., Krogager, L., Rasmussen, J. H., Andersen, F. L., Specht, L., Beyer, T., Kjær, A., Fischer, B. M., & Hansen, A. E. (2019) · Physica Medica · doi:10.1016/j.ejmp.2019.04.006 · Cited by 12
Audio-Based System for Automatic Measurement of Jump Height in Sports Science
Pueo, B., López, J. J., & Jiménez-Olmedo, J. M. (2019) · Sensors · doi:10.3390/s19112543 · Cited by 10
Nepal, G. M., Basaula, M., & Sharma, S. (2019) · European Journal of Physiotherapy · doi:10.1080/21679169.2019.1623313 · Cited by 10
Ofek, H., Alperin, M., & Laufer, Y. (2019) · Neurorehabilitation · doi:10.3233/nre-182662 · Cited by 11
Basioura, A., Tsousis, G., Boscos, C., Lymberopoulos, A. G., & Tsakmakidis, I. A. (2019) · Reproduction in Domestic Animals · doi:10.1111/rda.13494 · Cited by 10
Muñoz-Prieto, A., Martínez-Subiela, S., Cerón, J. M. C., & Tvarijonaviciute, A. (2019) · Research in Veterinary Science · doi:10.1016/j.rvsc.2019.07.019 · Cited by 12
Determination of Perampanel in Dried Plasma Spots: Applicability to Therapeutic Drug Monitoring
Franco, V., Baruffi, K., Marchiselli, R., Crema, F., Fattore, C., Romigi, A., GIORGIS, V. D., Tartara, E., Elia, M., D’Avolio, A., et al. (2019) · Therapeutic Drug Monitoring · doi:10.1097/ftd.0000000000000680 · Cited by 10
Validation of an automated home blood pressure measurement device in oldest-old populations
Godai, K., Kabayama, M., Saito, K., Asayama, K., Yamamoto, K. I., Sugimoto, K., Ohkubo, T., Rakugi, H., & Kamide, K. (2019) · Hypertension Research · doi:10.1038/s41440-019-0330-7 · Cited by 11
Lee, S. Y., Zheng, C., Brothers, R. O., & Buckley, E. M. (2019) · Biomedical Optics Express · doi:10.1364/boe.10.005362 · Cited by 10
Feasibility and Reproducibility of Transthoracic Echocardiography in Obese Patients
Snelder, S. M., Younge, J. O., Dereci, A., van Velzen, J. E., Akkerhuis, J. M., Laat, L. E. D. G., Zijlstra, F., & van Dalen, B. M. (2019) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2019.07.019 · Cited by 10
Longitudinal Change in Adolescent Bedtimes Measured by Self-Report and Actigraphy
Brychta, R. J., Rögnvaldsdóttir, V., Guðmundsdóttir, S. L., Stefansdottir, R. S., Hrafnkelsdóttir, S. M., Gestsdóttir, S., Arngrímsson, S. Á., Chen, K. Y., & Jóhannsson, E. (2019) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2019-0021 · Cited by 16
Prediction of body fat in male athletes from ultrasound and anthropometric measurements versus DXA
Pineau, J., & Bouslah, M. (2020) · The Journal of Sports Medicine and Physical Fitness · doi:10.23736/s0022-4707.19.09985-7 · Cited by 11
Jin, S., Zhao, Q., Zhang, D., Zhao, Z., & Mei, S. (2019) · Journal of Analytical Science & Technology · doi:10.1186/s40543-019-0198-9 · Cited by 10
Validity of the Wattbike 3-Minute Aerobic Test: Measurement and Estimation of Vo 2max
Hanson, N., Scheadler, C. M., Katsavelis, D., & Miller, M. G. (2019) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000003440 · Cited by 10
Semiautomated Process for Enumeration of Fishes from Recreational-Grade Side-Scan Sonar Imagery
Lawson, K. M., Ridgway, J. L., Mueller, A. T., Faulkner, J. D. A., & Calfee, R. D. (2019) · North American Journal of Fisheries Management · doi:10.1002/nafm.10373 · Cited by 10
Pernot, P., & Savin, A. (2020) · The Journal of Chemical Physics · doi:10.1063/5.0006204 · Cited by 12
Bozec, E., Girerd, N., Ferreira, J. P., Latar, I., Zannad, F. M., & Rossignol, P. (2020) · Artery Research · doi:10.2991/artres.k.200314.001 · Cited by 10
Robinson, S. K., Rodd, C. J., Metzger, D. L., & Sharma, A. (2020) · Paediatrics & Child Health · doi:10.1093/pch/pxaa026 · Cited by 12
Caiati, C., Lepera, M. E., Pollice, P., Iacovelli, F., & Favale, S. (2020) · Coronary Artery Disease · doi:10.1097/mca.0000000000000873 · Cited by 10
Mena, L. J., Félix, V. G., Ostos, R., González, A. J., Martínez-Peláez, R., Melgarejo, J. D., & Maestre, G. E. (2020) · JMIR mhealth and uhealth · doi:10.2196/18012 · Cited by 14
Agreement of Three Posturographic Force Plates in the Assessment of Postural Stability
Matłosz, P., Wyszyńska, J., Podgórska‐Bednarz, J., Leszczak, J., Rachwał, M., Przednówek, K., Drzał–Grabiec, J., Walicka-Cupryś, K., Drużbicki, M., & Zadarko, E. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17093188 · Cited by 12
Are Groundwater Level Data Collected by Citizen Scientists Trustworthy? A Cautionary Tale
Manda, A. K., Etheridge, R., Grace-McCaskey, C. A., Allen, T. R., & Howard, R. (2020) · Ground Water · doi:10.1111/gwat.13019 · Cited by 11
On the Practical Consequences of Misfit in Mokken Scaling
Crișan, D. R., Tendeiro, J. N., & Meijer, R. R. (2020) · Applied Psychological Measurement · doi:10.1177/0146621620920925 · Cited by 11
de Araújo, C. C., Juliato, C. R. T., Marques, A. D. A., Reis, A. M., & Brito, L. G. O. (2020) · International Urogynecology Journal · doi:10.1007/s00192-020-04344-y · Cited by 12
Kogure, G. S., Silva, R. C., Ribeiro, V. B., Mendes, M. C., Menezes-Reis, R., Ferriani, R. A., Furtado, C. L. M., & dos Reis, R. M. (2020) · Archives of Endocrinology and Metabolism · doi:10.20945/2359-3997000000246 · Cited by 10
Um, M. M., Castonguay, M., Amine, K. M., Giguère, J., Morin, I., & Dufour, S. (2020) · Frontiers in Veterinary Science · doi:10.3389/fvets.2020.00401 · Cited by 10
Morales, C. R., López‐López, S., Bravo-Aguilar, M., Cerezo-Téllez, E., Pedro, M. B.-D., López‐López, D., & Calvo‐Lobo, C. (2020) · Journal of Manipulative and Physiological Therapeutics · doi:10.1016/j.jmpt.2019.11.004 · Cited by 10
Ström, L., Bröjer, J. T., & Ekesten, B. (2020) · BMC Veterinary Research · doi:10.1186/s12917-020-02463-8 · Cited by 10
Kristensen, C. B., Steensgaard-Hansen, F., Myhr, K. A., Løkkegaard, N., Finsen, S. H., Hassager, C., & Møgelvang, R. (2020) · Kidney Medicine · doi:10.1016/j.xkme.2020.06.006 · Cited by 10
Nishida, Y., Tanaka, S., Nakae, S., Yamada, Y., Shirato, H., Hirano, H., Sasaki, S., & Katsukawa, F. (2020) · Nutrients · doi:10.3390/nu12092677 · Cited by 10
Mason, S. J., Davidson, B. S., Lehto, M., Ledreux, A., Granholm, A., & Gorgens, K. A. (2020) · Archives of Clinical Neuropsychology · doi:10.1093/arclin/acaa047 · Cited by 13
Alker, W., & Haase, H. (2020) · Biological Trace Element Research · doi:10.1007/s12011-020-02355-w · Cited by 10
A Gel Pad Designed to Measure Muscle Volume Using Freehand 3‐Dimensional Ultrasonography
Thomare, J., Lacourpaille, L., McNair, P. J., Crouzier, M., Ellis, R. F., & Nordez, A. (2020) · Journal of Ultrasound in Medicine · doi:10.1002/jum.15490 · Cited by 12
Ultrasound Analysis of Lateral Ankle Ligaments in Functional Ankle Instability
Rein, S., Houschyar, K. S., & Sterling-Hauf, T. (2020) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2020.08.018 · Cited by 10
Set distance time trials for predicting maximal aerobic speed in female Australian Rules Footballers
Lundquist, M., Nelson, M. J., Debenedictis, T. A., Gollan, S., FULLER, J. T., Larwood, T., & Bellenger, C. R. (2020) · Journal of science and medicine in sport · doi:10.1016/j.jsams.2020.10.002 · Cited by 15
Xie, S., Masokano, I. B., Liu, W., Long, X., Li, G., Pei, Y., & Li, W. (2020) · European Journal of Radiology · doi:10.1016/j.ejrad.2020.109472 · Cited by 10
The Impact of Sample Type on Vitamin D Quantification and Clinical Classification during Pregnancy
Harvey, S. M., Murphy, V. E., Gibson, P. G., Clarke, M. W., & Jensen, M. E. (2020) · Nutrients · doi:10.3390/nu12123872 · Cited by 11
Development of a rapid method for assessing the efficacy of antibacterial photocatalytic coatings
Scimone, A., Redfern, J., Patiphatpanya, P., Thongtem, T., Ratova, M., Kelly, P. J., & Verran, J. (2020) · Talanta · doi:10.1016/j.talanta.2020.122009 · Cited by 10
Vital Sign Detection Using Short-range mm-Wave Pulsed Radar
Bahmani, N., Rouvala, M., & Kaarna, A. (2021) · IEEE Global Conference on Life Sciences and Technologies (LifeTech) · doi:10.1109/lifetech52111.2021.9391910 · Cited by 10
Albano, D., Loria, A., Fanciullo, C., Bruno, A., Messina, C., Vecchio, A. D., & Sconfienza, L. M. (2020) · Applied Sciences · doi:10.3390/app10248941 · Cited by 10
MR Measures of Small Bowel Wall T2 Are Associated With Increased Permeability
Scott, R. A., Williams, H. G., Hoad, C. L., Alyami, A. S., Ortori, C. A., Grove, J. I., Marciani, L., Moran, G. W., Spiller, R. E., Menys, A., et al. (2020) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.27463 · Cited by 12
Weiss, T. L. D., Gössling, G. C. D. L., Antunes, M. V., Schwartsmann, G., Linden, R., & Verza, S. G. (2020) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2020.113861 · Cited by 10
Wyatt, J., Pearson, R., Walker, C. P., Brooks, R. L., Pilling, K., & McCallum, H. M. (2021) · Physics and Imaging in Radiation Oncology · doi:10.1016/j.phro.2021.01.005 · Cited by 11
Sepúlveda-Martínez, Á., Steding‐Ehrenborg, K., Rodríguez‐López, M., Ostenfeld, E., Valenzuela‐Alcaráz, B., Heiberg, E., Gratacós, E., Prat‐González, S., Crispi, F., & Hedström, E. (2021) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12693 · Cited by 10
The ideal marker for measuring GFR: what are we looking for?
Maioli, C., Mangano, M., Conte, F., Sole, A. D., Tagliabue, L., Alberici, F., Galassi, A., & Cozzolino, M. G. (2020) · Acta bio-medica dell'Ateneo parmense/Acta biomedica · doi:10.23750/abm.v91i4.9304 · Cited by 10
Cho, J. C.-S., Tollefson, L. J., & Reckelhoff, K. (2021) · Chiropractic & Manual Therapies · doi:10.1186/s12998-021-00390-5 · Cited by 10
Lee, S.-W., Lee, S., Kim, H., Kim, Y.-J., Kim, M. H., & Choi, J. (2021) · Medicine · doi:10.1097/md.0000000000025152 · Cited by 10
A validated LC-MS/MS method for the quantification of climbazole metabolites in human urine
Schmidtkunz, C., Küpper, K., Gries, W., & Leng, G. (2021) · Journal of Chromatography B · doi:10.1016/j.jchromb.2021.122677 · Cited by 10
Bichard, L. K., Rushworth, R. L., & Torpy, D. J. (2021) · Endocrine Practice · doi:10.1016/j.eprac.2021.04.005 · Cited by 11
Evaluation of the Accuracy of a Video and AI Solution to Measure Lower Leg and Foot Volume
Chausiaux, O., Williams, G., Nieznański, M., Bagdu, A., Downer, P., Keyser, M., & Husheer, S. (2021) · Medical Devices Evidence and Research · doi:10.2147/mder.s297713 · Cited by 10
Bernal-Ceballos, F., Wacher, N. H., Orea‐Tejeda, A., Hernández‐Gilsoul, T., & Castillo‐Martínez, L. (2021) · Clinical Nutrition ESPEN · doi:10.1016/j.clnesp.2021.04.015 · Cited by 11
Ang, D., Vollebregt, P. F., Carrington, E. V., Knowles, C. H., & Scott, S. M. (2021) · Digestive Diseases and Sciences · doi:10.1007/s10620-021-06994-4 · Cited by 12
Eyre, S., Bosaeus, I. G., Jensen, G., & Saeed, A. (2021) · Journal of Renal Nutrition · doi:10.1053/j.jrn.2021.03.007 · Cited by 11
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.