STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 30,001–30,100 of 47,868
Lauszus, F. F., Rosgaard, A., Lousen, T., Rasmussen, O., Klebe, T., & Klebe, J. G. (2007) · Acta Obstetricia Et Gynecologica Scandinavica · doi:10.1080/00016340701472773 · Cited by 10
Fountoulakis, K. Ν., Panagiotidis, P. T., Siamouli, M., Magiria, S., Sokolaki, S., Kantartzis, S., Rova, K., Papastergiou, N., Shoretstanitis, G., Oral, T., et al. (2008) · Cognitive and Behavioral Neurology · doi:10.1097/wnn.0b013e318165b120 · Cited by 10
Novel Low-Cost Assay for the Monitoring of CD4 Counts in HIV-Infected Individuals
Srithanaviboonchai, K., Rungruengthanakit, K., Nouanthong, P., Pata, S., Sirisanthana, T., & Kasinrerk, W. (2008) · JAIDS Journal of Acquired Immune Deficiency Syndromes · doi:10.1097/qai.0b013e3181624ab5 · Cited by 10
Choi, J. Y., Kwon, H. S., Yoo, B. W., Shin, J. I., Sul, J. H., Park, H. K., & Park, Y. H. (2007) · International Journal of Cardiology · doi:10.1016/j.ijcard.2007.02.020 · Cited by 10
Influence of Weight Classification on Walking and Jogging Energy Expenditure Prediction in Women
Heden, T. D., LeCheminant, J. D., & Smith, J. D. (2012) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2012.10599873 · Cited by 10
Bevc, S., Hojs, R., Ekart, R., Gorenjak, M., & Puklavec, L. (2012) · Kidney & Blood Pressure Research · doi:10.1159/000341918 · Cited by 10
Liao, C., Lin, C.-Y., & Liu, J. (2007) · Journal of Biopharmaceutical Statistics · doi:10.1080/10543400601177327 · Cited by 10
Efeitos do treinamento resistido sobre a força muscular de idosas: uma comparação entre métodos
Lima, R. M., Bottaro, M., Carregaro, R. L., de Oliveira, J. F., Bezerra, L. M. A., & Oliveira, R. J. (2012) · Brazilian Journal of Kinanthropometry and Human Performance · doi:10.5007/1980-0037.2012v14n4p409 · Cited by 18
Confiabilidade da medida de espessuras musculares pela ultrassonografia
Gomes, P. S. C., Meirelles, C., Leite, S. P., & Montenegro, C. A. B. (2010) · Revista Brasileira de Medicina do Esporte · doi:10.1590/s1517-86922010000100008 · Cited by 21
Ultraviolet analysis of donated corneas: a portable prototype
Lincoln, V. A. C., Ventura, L., & Sousa, S. J. D. F. E. (2010) · Applied Optics · doi:10.1364/ao.49.004890 · Cited by 10
Validity of self-reported weight and stature in adolescents from Cuiabá, Central-Western Brazil
Rodrigues, P. R. M., Gonçalves‐Silva, R. M. V., & Pereira, R. A. (2013) · Revista de Nutrição · doi:10.1590/s1415-52732013000300003 · Cited by 10
Bisdas, S., Rumboldt, Z., Surlan, K., Koh, T. S., Deveikis, J. P., & Spampinato, M. V. (2008) · European Radiology · doi:10.1007/s00330-008-0973-2 · Cited by 10
Sánchez-Sánchez, M. M., Sánchez-Izquierdo, R., Sánchez-Muñoz, E. I., Martínez-Yegles, I., Fraile-Gamo, M. P., & Arias-Rivera, S. (2013) · Enfermería Intensiva · doi:10.1016/j.enfi.2013.09.002 · Cited by 12
Interrater reliability of endoscopic parameters following sinus surgery
Smith, T. L., Hwang, P. H., Murr, A. H., Lavigne, F., & Koreck, A. (2011) · The Laryngoscope · doi:10.1002/lary.22440 · Cited by 11
Pintus, E., Ros‐Santaella, J. L., & Garde, J. J. (2014) · Reproduction Fertility and Development · doi:10.1071/rd13419 · Cited by 10
Biochemical diagnosis and assessment of disease activity in acromegaly: a two-decade experience
Minuto, F. M., Resmini, E., Boschetti, M., Rebora, A., Fazzuoli, L., Arvigo, M., Giusti, M., & Ferone, D. (2011) · Pituitary · doi:10.1007/s11102-011-0313-4 · Cited by 10
Randomized clinical trial of total vs. subtotal hysterectomy: validity of the trial questionnaire
Gimbel, H. M., Zobbe, V., Ottesen, B., & Tabor, A. (2002) · Acta Obstetricia Et Gynecologica Scandinavica · doi:10.1034/j.1600-0412.2002.811012.x · Cited by 10
Kumar, P., Bourke, C., Flanders, J., Gorman, T., & Patel, H. (2013) · Physiotherapy Theory and Practice · doi:10.3109/09593985.2013.834490 · Cited by 10
Jones, A. N., Blank, R. D., Lindstrom, M. J., Penniston, K. L., & Hansen, K. E. (2009) · Osteoporosis International · doi:10.1007/s00198-009-1058-z · Cited by 10
Acierno, M. J., Mitchell, M. A., Freeman, D. M., Schuster, P. J., Guzman, D. S.-M., & Tully, T. N. (2009) · American Journal of Veterinary Research · doi:10.2460/ajvr.70.9.1151 · Cited by 10
Unreliability of Breath Methane as a Candidate Indicator of Functional Bowel Disorders
JONDERKO, K., Gabriel-Jaśniok, A., Szymszal, M., Kasicka-Jonderko, A., & Błońska‐Fajfrowska, B. (2008) · Gut and Liver · doi:10.5009/gnl.2008.2.3.180 · Cited by 10
Validating a clinical measure of levator hiatus size
Boyles, S. H., Edwards, S. R., Gregory, W. T., Denman, M. A., & Clark, A. (2007) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2006.08.028 · Cited by 10
Defining ELISpot cut-offs from unreplicated test and control wells
Alexander, N. D. E., Fox, A., Lien, V. T. K., Dong, T., Lee, L. Y.-H., Hằng, N. L. K., Mai, L. Q., & Horby, P. (2013) · Journal of Immunological Methods · doi:10.1016/j.jim.2013.02.014 · Cited by 10
Deng, Y., Guo, S., Su, H., Wang, Q., Tan, Z., Wu, J., & Zhang, D. (2014) · Echocardiography · doi:10.1111/echo.12645 · Cited by 10
Feasibility and Reliability of Ankle/Arm Blood Pressure Index in Preventive Medicine
Papoz, L., Ponton, A., Segond, P., Becker, F., Drouet, L. O., Levenson, J. A., Marazanof, M., Sentou, Y., Chollet, E., Étiemble, J., et al. (2000) · Angiology · doi:10.1177/000331970005100603 · Cited by 11
Does impedance cardiography reliably estimate left ventricular ejection fraction?
van der Meer, N. J. M., Oomen, M. W. N., Noordegraaf, A. V., Pijpers, R. J., Plaizier, M. A. B. D., & VRIES, P. M. J. M. D. (1996) · The Journal of Clinical Monitoring · doi:10.1007/bf02025304 · Cited by 10
Validation of the Actiheart for estimating physical activity related energy expenditure in pregnancy
Melzer, K., Lazzeri, M., Armand, S., Boulvain, M., Schutz, Y., & Kayser, B. (2012) · e-SPEN Journal · doi:10.1016/j.eclnm.2011.12.008 · Cited by 11
Screening of snoring with an MP3 recorder
Kreivi, H., Salmi, T. K., Maasilta, P. K., & Bachour, A. (2012) · Sleep And Breathing · doi:10.1007/s11325-012-0652-z · Cited by 11
Effect of alcohol swabbing on capillary blood glucose measurements
Dunning, P., Rantzau, C., & Ward, G. (1994) · Practical Diabetes · doi:10.1002/pdi.1960110610 · Cited by 10
Repeatability of the sonographic assessment of fetal sucking and swallowing movements
Levy, D., Zielinsky, P., Aramayo, A. M., Behle, I., Stein, N. L., & Dewes, L. O. (2005) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.1868 · Cited by 10
Krombach, G. A., Plum, T., Koos, R., Hoffmann, R., Altiok, E., Kraemer, N. A., Günther, R. W., & Schoth, F. (2010) · European Radiology · doi:10.1007/s00330-010-1969-2 · Cited by 10
Does Normal Ageing Alter Right Ventricular Relaxation Properties? A Tissue Doppler Study
Chiha, J., Boyd, A. C., & Thomas, L. (2010) · Heart Lung and Circulation · doi:10.1016/j.hlc.2010.03.001 · Cited by 10
Nilsson, T., Ahlgren, Å. R., Albinsson, J., Segstedt, S., Nilsson, J. Å., Jansson, T. T., Persson, H. W., & Cinthio, M. (2013) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2013.0449 · Cited by 10
Gref, M., & Karp, K. H. (2009) · Nuclear Medicine Communications · doi:10.1097/mnm.0b013e328315e0c6 · Cited by 10
Bandholm, T., Rose, M. H., Sonne‐Holm, S., & Jensen, B. R. (2008) · European Journal of Applied Physiology · doi:10.1007/s00421-008-0808-5 · Cited by 10
Coppadoro, A., Bellani, G., Bronco, A., Borsa, R., Lucchini, A., Bramati, S., Avalli, L., Marcolin, R., & Pesenti, A. M. (2014) · BMC Anesthesiology · doi:10.1186/1471-2253-14-22 · Cited by 10
Influence of medial meniscectomy on tibiofemoral joint space width
Ayral, X., Bonvarlet, J. P., Simonnet, J., Auleley, G.-R., Dougados, M., & Ravaud, P. (2003) · Osteoarthritis and Cartilage · doi:10.1016/s1063-4584(03)00005-0 · Cited by 10
Hidalgo, M., Urbano, M., Ortíz, I., Demyda-Peyrás, S., Murabito, M. R., Gálvez, M. J., & Dorado, J. (2015) · Theriogenology · doi:10.1016/j.theriogenology.2015.03.030 · Cited by 10
Jesse, S., Kassubek, J., Müller, H., Ludolph, A. C., & Unrath, A. (2012) · BMC Neurology · doi:10.1186/1471-2377-12-163 · Cited by 12
Using R2* values to evaluate brain tumours on magnetic resonance imaging: Preliminary results
Liu, Z., Liao, H.-B., Yin, J.-H., & Li, Y. (2013) · European Radiology · doi:10.1007/s00330-013-3057-x · Cited by 10
de Mey, C., Schroeter, V., Butzer, R., Roll, S., & Belz, G. (1995) · British Journal of Clinical Pharmacology · doi:10.1111/j.1365-2125.1995.tb04549.x · Cited by 10
Assessment of orthostatic fluid shifts with strain gauge plethysmography
Thijs, R. D., Bruijnzeels, M., Kamper, A. M., van Dijk, A. D., & van Dijk, J. G. (2007) · Clinical Science · doi:10.1042/cs20070060 · Cited by 10
Measurement of Ulnar Variance on Uncalibrated Digital Radiographic Images
de Vries, J., Souer, J. S., Zurakowski, D., & Ring, D. (2009) · Hand · doi:10.1007/s11552-009-9249-9 · Cited by 10
Renal function assessment in patients with systemic lupus erythematosus
Martínez‐Martínez, M. U., Borjas‐García, J. A., Magaña-Aquino, M., Cuevas-Orta, E., Llamazares-Azuara, L., & Abud‐Mendoza, C. (2011) · Rheumatology International · doi:10.1007/s00296-011-1940-9 · Cited by 10
Percentiles of Inspiratory Capacity in Healthy Nonsmokers: A Pilot Study
Bottai, M., Pistelli, F., Pede, F. D., Baldacci, S., Simoni, M., Maio, S., Carrozzi, L., & Viegi, G. (2011) · Respiration · doi:10.1159/000327206 · Cited by 10
A new method to estimate rCBF using IMP and SPECT without any blood sampling
Nishizawa, S., Shiozaki, T., Ueno, M., Toyoda, H., Shimono, T., Kamoto, Y., Fujita, T., Yonekura, Y., & Konishi, J. (2000) · Annals of Nuclear Medicine · doi:10.1007/bf02988289 · Cited by 10
Utilização da espessura de dobras cutâneas para a estimativa da gordura corporal em idosos
Rech, C. R., Cordeiro, B. A., Petróski, E. L., & de Vasconcelos, F. D. A. G. (2010) · Revista de Nutrição · doi:10.1590/s1415-52732010000100003 · Cited by 16
Wootton, S. L., Ng, C. L. W., McKeough, Z. J., JENKINS, S. C., Hill, K., & Alison, J. A. (2014) · Chronic Respiratory Disease · doi:10.1177/1479972314527470 · Cited by 10
Statistical methods inArthritis & Rheumatism: Current trends
Kim, M. (2006) · Arthritis & Rheumatism · doi:10.1002/art.22251 · Cited by 13
Peters, C. D., Jespersen, B., & Nørregaard, R. (2012) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365513.2012.713175 · Cited by 10
Delaby, C., Gabelle, A., Meynier, P., Loubière, V., Vialaret, J., Tiers, L., Ducos, J., Hirtz, C., & Lehmann, S. (2013) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2013-0611 · Cited by 11
Concurrent comparison of energy intake and expenditure among adults in Butajira District, Ethiopia
Tesfaye, F., Byass, P., & Wall, S. (2008) · Public Health Nutrition · doi:10.1017/s1368980008001705 · Cited by 10
A Clinical Alternative to Fluorophotometry for Measuring Tear Production in the Diagnosis of Dry Eye
McCann, L. C., Tomlinson, A., Pearce, E. I., Khanal, S., Kaye, S. B., & Fisher, A. C. (2010) · Cornea · doi:10.1097/ico.0b013e3181c58ee2 · Cited by 10
Odéen, H., Uppman, M., Markl, M., & Spottiswoode, B. S. (2011) · Physiological Measurement · doi:10.1088/0967-3334/32/4/003 · Cited by 10
Measurement and repeatability of interrupter resistance in unsedated newborn infants
Adams, A., Olden, C., Wertheim, D. F., Ives, A. J., Bridge, P. D., Lenton, J., & Seddon, P. C. (2009) · Pediatric Pulmonology · doi:10.1002/ppul.21039 · Cited by 10
Knoops, A. J. G., van der Graaf, Y., Appelman, A. P. A., Mali, W. P. T. M., & Geerlings, M. I. (2009) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2009.91 · Cited by 10
Pattanapanyasat, K., Noulsri, E., Lerdwana, S., Sukapirom, K., Onlamoon, N., & Tassaneetrithep, B. (2009) · JAIDS Journal of Acquired Immune Deficiency Syndromes · doi:10.1097/qai.0b013e3181c4b8ae · Cited by 10
Chen, T., Yang, Z., Dong, Z.-H., Li, Y., Yao, J., Wang, Q., & Qian, L. (2010) · European Journal of Radiology · doi:10.1016/j.ejrad.2010.07.006 · Cited by 10
A novel, non-invasive method of respiratory monitoring for use with stereotactic procedures
Cleary, D. R., Phillips, R. S., Wallisch, M., & Heinricher, M. M. (2012) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2012.06.029 · Cited by 10
Gonzalez, J. T., Veasey, R. C., Rumbold, P. L. S., & Stevenson, E. (2012) · Appetite · doi:10.1016/j.appet.2012.02.043 · Cited by 13
Wickramasinghe, P. (2011) · The Indian Journal of Pediatrics · doi:10.1007/s12098-011-0615-6 · Cited by 10
Assessment of exercise capacity in women with type 2 diabetes
Segerström, Å. B., Glans, F., Eriksson, K., Groop, L., Thorsson, O., & Wollmer, P. (2008) · Clinical Physiology and Functional Imaging · doi:10.1111/j.1475-097x.2008.00808.x · Cited by 12
Boonlert, W., Lolekha, P. H., Kost, G. J., & Lolekha, S. (2003) · Point of Care The Journal of Near-Patient Testing & Technology · doi:10.1097/00134384-200309000-00004 · Cited by 10
Roelants, V., Bol, A., Bernard, X., Coppens, A., Melin, J., Gerber, B. L., & Vanoverschelde, J. (2006) · Journal of Nuclear Cardiology · doi:10.1007/bf02971246 · Cited by 10
Kingma, J. G., Simard, D., & Rouleau, J. R. (2005) · Journal of Thrombosis and Thrombolysis · doi:10.1007/s11239-005-1201-4 · Cited by 10
Kim, S. M., Haider, M. A., Milosevic, M., & Yeung, I. W. T. (2012) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12010 · Cited by 10
Nybäck‐Nakell, Å., von Heijne, M., Adamson, U., Lins, P., & Landstedt‐Hallin, L. (2004) · Diabetes & Metabolism · doi:10.1016/s1262-3636(07)70149-0 · Cited by 12
Odagiri, K., Wakabayashi, Y., Tawarahara, K., Kurata, C., Urusheda, T., Katoh, H., Satoh, H., & Hayashi, H. (2006) · Annals of Nuclear Medicine · doi:10.1007/bf03026815 · Cited by 10
Chládková, J., Havlínová, Z., Chyba, T., Krčmová, I., & Chládek, J. (2008) · Journal of Asthma · doi:10.1080/02770900802312582 · Cited by 10
Mann, J. B., Ivey, P. J., Brechue, W. F., & Mayhew, J. L. (2014) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000000411 · Cited by 10
Wentland, A. L., Korosec, F. R., Vigen, K. K., Wieben, O. E., Fine, J. P., & Grist, T. M. (2006) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20715 · Cited by 10
Christoforidis, A., Zevgaridou, E., Tsatra, I., Perifanis, V., Vlachaki, E., Papassotiriou, I., Apostolakou, F., & Athanassiou‐Metaxa, M. (2007) · Journal of Pediatric Hematology/Oncology · doi:10.1097/mph.0b013e318142b51e · Cited by 10
A note on the comparison of particle number counters
Giechaskiel, B., & Stilianakis, N. I. (2009) · Measurement Science and Technology · doi:10.1088/0957-0233/20/7/077003 · Cited by 10
Prevention or Retardation of Joint Damage in Rheumatoid Arthritis
Boers, M., & van der Heijde, D. (2002) · Drugs · doi:10.2165/00003495-200262120-00002 · Cited by 10
Owiredu, W. K. B. A., Amegatcher, G., & Amidu, N. (2009) · Journal of Medical Sciences(Faisalabad) · doi:10.3923/jms.2009.185.193 · Cited by 11
Ernst, M. E., Weber, C. A., Dawson, J. D., O'Connor, M. A., Lin, W., Carter, B. L., & BERGUS, G. R. (2008) · Journal of Clinical Hypertension · doi:10.1111/j.1751-7176.2008.07784.x · Cited by 10
Habibi, R., Lell, M., Steiner, R., Ruehm, S. G., Sayre, J. W., Nael, K., & Finn, J. P. (2008) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1302 · Cited by 10
Rech, C. R., Petróski, E. L., Böing, O., Babel, R. J., & Soares, M. R. (2008) · Revista Brasileira de Medicina do Esporte · doi:10.1590/s1517-86922008000200009 · Cited by 14
Unmanned Assessment of Respirator Carbon Dioxide Levels: Comparison of Methods of Measurement
Caretti, D. M., & Coyne, K. M. (2008) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620801969998 · Cited by 10
Sonography-guided positioning of intravenous long lines in neonates
Brissaud, O., Harper, L., Lamireau, D., Jouvencel, P., & Fayon, M. J. (2009) · European Journal of Radiology · doi:10.1016/j.ejrad.2009.03.017 · Cited by 10
Hwang, S. H., Choi, E., Park, C. H., Paek, M. Y., Greiser, A., Kim, T. H., & Choi, B. W. (2014) · International journal of cardiac imaging · doi:10.1007/s10554-014-0489-6 · Cited by 10
Single-breath CO2 analysis as a predictor of lung volume change in a model of acute lung injury
Arnold, J. H., Stenz, R. I., Grenier, B., & Thompson, J. E. (2000) · Critical Care Medicine · doi:10.1097/00003246-200003000-00026 · Cited by 10
Measurements of PEEP-Induced Changes in Lung Volume
Uhlig, T., Kondo, T., & Sly, P. D. (1997) · CHEST Journal · doi:10.1378/chest.112.1.107 · Cited by 10
Rodríguez‐Martínez, C. E., Sossa‐Briceño, M. P., & Niño, G. (2015) · Journal of Asthma · doi:10.3109/02770903.2014.1002565 · Cited by 10
Bedside red cell volumetry by low-dose carboxyhaemoglobin dilution using expiratory gas analysis
Sawano, M., Mato, T. K., & Tsutsumi, H. (2005) · British Journal of Anaesthesia · doi:10.1093/bja/aei302 · Cited by 10
England, A., García‐Fiñana, M., How, T. V., Vallabhaneni, S. R., & McWilliams, R. G. (2012) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2011.10.083 · Cited by 10
Davani, S., Bérard, M., Royer, B., Kantelip, J., & Muret, P. (2004) · Pathologie Biologie · doi:10.1016/j.patbio.2004.07.033 · Cited by 10
Head‐to‐head comparison between Actigraph 7164 and GT 1M accelerometers in adolescents
Tanha, T., Tornberg, Å. B., Wollmer, P., & Dencker, M. (2012) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12003 · Cited by 10
Hui, S. S., & Cheung, P. P. (2004) · Measurement in Physical Education and Exercise Science · doi:10.1207/s15327841mpee0803_3 · Cited by 10
Ying, H., Liu, D., Jiang, L., Li-Xia, L., Xia, Y., Xie, L., & Wei-Dong, R. (2013) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2013.04.015 · Cited by 10
Influence of the scale function on wavelet transformation of the surface electromyographic signal
Frère, J., Göpfert, B., SLAWINSKI, J. S., & Tourny, C. (2011) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2010.517199 · Cited by 10
Concurrent Validity of an OMNI Rating of Perceived Exertion Scale for Bench Stepping Exercise
Krause, M. P., Goss, F. L., Robertson, R. J., Kim, K., Elsangedy, H. M., Krinski, K., & da Silva, S. G. (2012) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0b013e318220df8e · Cited by 10
Yan-Vergnes, W., Vergnes, J., Dumoncel, J., Baron, P., Marchal-Sixou, C., & Braga, J. (2013) · Journal of PHYSIOLOGICAL ANTHROPOLOGY · doi:10.1186/1880-6805-32-22 · Cited by 10
Gastroesophageal reflux in infants with wheezing
Sheikh, S. I., Stephen, T., Howell, L., & Eid, N. S. (1999) · Pediatric Pulmonology · doi:10.1002/(sici)1099-0496(199909)28:3<175::aid-ppul3>3.0.co;2-u · Cited by 92
A New Voice Rating Tool for Clinical Practice
Gould, J., Waugh, J., Carding, P. N., & Drinnan, M. J. (2011) · Journal of Voice · doi:10.1016/j.jvoice.2011.07.011 · Cited by 10
Quinton, A., Lewis, P., Ali, P. A., Morgan, C., & Bertelli, G. (2013) · Medical Oncology · doi:10.1007/s12032-013-0661-1 · Cited by 10
The effects of anatomical structures on adult forearm and upper arm noninvasive blood pressures
Schell, K. A., Richards, J. G., & Farquhar, W. B. (2007) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e3280858cd0 · Cited by 10
Comte, A., Lalande, A., Aho, S., WALKER, P. M., & Brunotte, F. (2004) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2004.01.058 · Cited by 10
Analysis of nonlinear volume-dependent respiratory system mechanics in pediatric patients
Kessler, V., Newth, C. J. L., & Guttmann, J. (2000) · Pediatric Critical Care Medicine · doi:10.1097/00130478-200010000-00004 · Cited by 10
Bendeddouche, I., Rostom, S., Bahiri, R., Boudali, A., Srifi, N., Mawani, N., Mengat, M., Badri, D. E., Lazrak, N., Abouqal, R., et al. (2012) · Clinical Rheumatology · doi:10.1007/s10067-012-1961-0 · Cited by 10
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.