STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 30,701–30,800 of 47,868
Baraka, A., El‐Khatib, M. F., Muallem, E., Jamal, S., Haroun, S. T., & Aouad, M. T. (2005) · Journal of ExtraCorporeal Technology · doi:10.1051/ject/200537192 · Cited by 9
Feasibility and Reliability of a Coding System to Capture In-Session Group Behavior in Adolescents
Ladd, B. O., Tomlinson, K. L., Myers, M. G., & Anderson, K. G. (2015) · Prevention Science · doi:10.1007/s11121-015-0588-1 · Cited by 9
Three-Dimensional Reconstruction Volume: A Novel Method for Volume Measurement in Kidney Cancer
Durso, T. A., Carnell, J., Türk, T., & Gupta, G. N. (2014) · Journal of Endourology · doi:10.1089/end.2013.0796 · Cited by 11
The Development of the Baboon Prostate: Ultrasound Methodology, Modelling, and Natural History
JIN, B., Turner, L., Crawford, B. A. L., Birrell, A., & Handelsman, D. J. (1996) · Journal of Andrology · doi:10.1002/j.1939-4640.1996.tb01799.x · Cited by 9
Culibrk, B., Stone, E. J., Levin, E., Weiss, S., Serrano, K., & Devine, D. V. (2012) · Vox Sanguinis · doi:10.1111/j.1423-0410.2012.01601.x · Cited by 9
Simpson, J. L., Gibson, P. G., Yang, I. A., Upham, J. W., James, A., Reynolds, P. N., & Hodge, S. J. (2013) · Respirology · doi:10.1111/resp.12213 · Cited by 9
Vanlinthout, L. E., Booij, L. H. D. J., Egmond, J. V., & Robertson, E. N. (2010) · Anaesthesia · doi:10.1111/j.1365-2044.2010.06342.x · Cited by 9
Fetal liver T2* values: Defining a standardized scale
Goitein, O., Eshet, Y., Hoffmann, C., Raviv‐Zilka, L., Salem, Y., Hamdan, A., Goitein, D., Kushnir, T., Eshed, I., DiSegni, E., et al. (2013) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24132 · Cited by 9
The highly abundant urinary metabolite urobilin interferes with the bicinchoninic acid assay
Sampson, D. L., Chng, Y. L., Upton, Z., Hurst, C. P., Parker, A. W., & Parker, T. J. (2013) · Analytical Biochemistry · doi:10.1016/j.ab.2013.07.027 · Cited by 9
Dual-Wavelength Optoelectronic Sensor for Monitoring Uric Acid Concentration in Dialysate
Михайлович, В. А., Gerasimchuk, R. P., Zemchenkov, A. Y., Коноплев, Г., Рубинский, А. В., Stepanova, O. S., & Frorip, A. (2015) · Biomedical Engineering · doi:10.1007/s10527-015-9512-z · Cited by 9
Bright, E., Pearcy, R., & Abrams, P. (2011) · British Journal of Urology · doi:10.1111/j.1464-410x.2011.10507.x · Cited by 9
Ippolito, D., Casiraghi, A. S., Franzesi, C. T., Bonaffini, P. A., Fior, D., & Sironi, S. (2015) · Journal of Computer Assisted Tomography · doi:10.1097/rct.0000000000000331 · Cited by 9
Reproducibility and biological variability of HDL's vascular functional assays
O'Neill, F., McLoughlin, E., Riwanto, M., Manz, J., Adler, A., Sutill, E., Khan, T. A., Haywood, R., Kay, C. W. M., D’Aiuto, F., et al. (2015) · Atherosclerosis · doi:10.1016/j.atherosclerosis.2015.06.005 · Cited by 10
Lautié, E., Rasse, C., Rozet, E., Mourgues, C., Vanhelleputte, J., & Quetin‐Leclercq, J. (2012) · Journal of Separation Science · doi:10.1002/jssc.201200347 · Cited by 9
Bortolotti, F., Trevisan, M. T., Micciolo, R., Canal, L., Vandoros, A., Palmbach, T. M., & Tagliaro, F. (2012) · Clinica Chimica Acta · doi:10.1016/j.cca.2012.11.015 · Cited by 9
Dellafiore, C., Lava, M., Vercellin, A. C. V., Cutolo, C. A., Tinelli, C., SILVESTRI, A. D., Calliada, F., & Milano, G. (2015) · La radiologia medica · doi:10.1007/s11547-015-0522-4 · Cited by 10
Establishment of a conversion factor for the Cepheid GeneXpert BCR-ABL Assay
McNiven, M., & Talaulikar, D. (2011) · Pathology · doi:10.1097/pat.0b013e32834e4203 · Cited by 9
Optimization of ultrasound assessments of arterial function
Stoner, L. R., West, C., Cates, D. M., & Young, J. M. (2011) · Open Journal of Clinical Diagnostics · doi:10.4236/ojcd.2011.13004 · Cited by 10
Cao, K., Xu, J., Sun, H., Li, P., Li, J., Cheng, X., & Su, H. (2014) · Journal of the American Society of Hypertension · doi:10.1016/j.jash.2014.07.030 · Cited by 9
Liu, Y., Steinacker, J. M., & Stanch, M. (1995) · European Journal of Applied Physiology · doi:10.1007/bf00240412 · Cited by 9
Anwar, A. M., Nosir, Y. F. M., Alasnag, M. A., Llemit, M. A., Elhagoly, A. A., & Chamsi‐Pasha, H. (2013) · International journal of cardiac imaging · doi:10.1007/s10554-013-0247-1 · Cited by 10
Determinação da densidade corporal por equações generalizadas: facilidade e simplificação no método
Serra, A. J., Marcolongo, A. D. A., Rica, R. L., Barbieri, P., Reis, D., da Silva, J. A., & Bocalini, D. S. (2009) · ConScientiae Saúde · doi:10.5585/conssaude.v8i1.1421 · Cited by 9
Bennett, S., Weng, H., Walker, S. L., Placer, M., & Litster, A. (2015) · Journal of Applied Animal Welfare Science · doi:10.1080/10888705.2014.999916 · Cited by 12
Huhnstock, S., Svenningsen, S., Pripp, A. H., Terjesen, T., & Wiig, O. (2014) · Acta Orthopaedica · doi:10.3109/17453674.2014.934188 · Cited by 9
Chamorro-Moriana, G., Roldán, J. R., Jiménez‐Rejano, J., Chillón‐Martínez, R., & Suárez-Serrano, C. (2012) · Gait & Posture · doi:10.1016/j.gaitpost.2012.09.018 · Cited by 9
Circumferential dynamic stabilization of the lumbar spine: a biomechanical analysis
Käfer, W., Cakir, B., Midderhoff, S., Reichel, H., & Wilke, H. (2014) · European Spine Journal · doi:10.1007/s00586-014-3286-y · Cited by 9
Paakkala, A., Dastidar, P., Ryymin, P., Huhtala, H., & Mustonen, J. T. (2004) · European Radiology · doi:10.1007/s00330-004-2363-8 · Cited by 9
Liu, Y.-W., Tseng, C., Su, C.-T., Chang, Y., Chen, J., Chen, L.-Y., Tsai, L.-M., Chen, J.-H., Wang, M.-C., & Tsai, W. (2014) · IJC Heart & Vasculature · doi:10.1016/j.ijcha.2014.10.016 · Cited by 10
Wong, A. C. W., & McPherson, B. (2014) · International Journal of Audiology · doi:10.3109/14992027.2014.952457 · Cited by 9
Bartoli, M. A., Kober, F., Cozzone, P. J., Thompson, R. W., Alessi, M., & Bernard, M. (2012) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2012.08.002 · Cited by 9
Dual-source CT in Heart Transplant Recipients
Bastarrika, G., Arraiza, M., Cecco, C. N. D., Broncano, J., Mastrobuoni, S., Ubilla, M., Pueyo, J. C., & Rábago, G. (2009) · Journal of Thoracic Imaging · doi:10.1097/rti.0b013e318190426d · Cited by 9
Evaluation of PIMA Point-of-care CD4 Analyzer in Yunnan, China
Liang, J., Duan, S., Ma, Y., Wang, J., Su, Y., Zhang, H., Ou, C., Ling, H., Qi, M.-S., Bulterys, M., et al. (2015) · Chinese Medical Journal · doi:10.4103/0366-6999.154283 · Cited by 9
Noninvasive measurement of pH in platelet concentrates with a fiber optic fluorescence detector
Reed, M. W., Geelhood, S., Barker, L. M., Pfalzgraf, R. D., Vlaar, R., Gouwerok, E., Cuyper, I. M. D., Harris, P., Verhoeven, A. J., & de Korte, D. (2009) · Transfusion · doi:10.1111/j.1537-2995.2009.02125.x · Cited by 9
Dellava, J. E., & Hoffman, D. J. (2009) · British Journal Of Nutrition · doi:10.1017/s0007114508143537 · Cited by 15
DiBiase, A. T., Elcock, C., Smith, R., & Brook, A. H. (2006) · Archives of Oral Biology · doi:10.1016/j.archoralbio.2006.03.007 · Cited by 10
A Pilot Study of Neonatal and Pediatric Esophageal Pulse Oximetry
Kyriacou, P. A., Jones, D. P., Langford, R. M., & Petros, A. (2008) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e31817e67d1 · Cited by 10
Schallenberg, M., Dekowski, D., Kremmer, S., Selbach, J. M., & Steuhl, K. (2012) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-012-2219-x · Cited by 9
Magnetic resonance angiography vs. angiography in tetralogy of Fallot
Rao, U. V., Vanajakshamma, V., Rajasekhar, D., Lakshmi, A. Y., & Reddy, R. N. (2013) · Asian Cardiovascular and Thoracic Annals · doi:10.1177/0218492312457360 · Cited by 9
Conde, M., Roldán-Fontana, E., Chueca, N., Pardo, S., & Porras-Gracia, J. (2010) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2010.04.057 · Cited by 9
Isr: Background, Evolution and Implementation, with Specific Consideration for Ligand-Binding Assays
Findlay, J. W., & Kelley, M. M. (2014) · Bioanalysis · doi:10.4155/bio.13.339 · Cited by 9
Sandgaard, N. C. F., Andersen, J. L., Holstein‐Rathlou, N., & Bie, P. (2002) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00494.2001 · Cited by 10
Müller, H., Frangos, C., Fleury, E., Righetti, A., Lerch, R. A., & Burri, H. (2010) · Echocardiography · doi:10.1111/j.1540-8175.2009.00976.x · Cited by 10
Li, Y., Röhrl, S. M., Bøe, B., & Nordsletten, L. (2014) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2014.06.007 · Cited by 9
Effects of the frame acquisition rate on the sensitivity of gastro-oesophageal reflux scintigraphy
Codreanu, I., Chamroonrat, W., Edwards, K., & Zhuang, H. M. (2013) · British Journal of Radiology · doi:10.1259/bjr.20130084 · Cited by 9
Tirez, K., Vanhoof, C., Hofman, S. C. K., Deproost, P., Swerts, M., & Salomez, J. (2014) · Communications in Soil Science and Plant Analysis · doi:10.1080/00103624.2013.867056 · Cited by 9
Keet, S. W. M., Bulte, C. S. E., Sivanathan, A., Verhees, L., Allaart, C. P., Boer, C., & Bouwman, R. A. (2014) · Anaesthesia · doi:10.1111/anae.12628 · Cited by 9
Kuroiwa, Y., Nagamachi, S., Miyati, T., Yamaguchi, K., Nishii, R., Kuga, N., Azuma, T., Arita, H., Maeda, M., Tamura, S., et al. (2011) · Annals of Nuclear Medicine · doi:10.1007/s12149-011-0546-3 · Cited by 9
Determination of the mitral papillary muscle positions by the septal‐to‐free wall arc ratio method
Hakacova, N., Robinson, A. M. C., Maynard, C. C., Wagner, G. S., & Idriss, S. F. (2009) · Clinical Physiology and Functional Imaging · doi:10.1111/j.1475-097x.2008.00853.x · Cited by 9
Retinal oximetry using ultrahigh-resolution optical coherence tomography
Jiang, H., Ye, Shen, S., Lam, B. L., DeBuc, C., ge, G., Sehi, & Wang, J. (2012) · Clinical ophthalmology · doi:10.2147/opth.s37774 · Cited by 10
Szmigielski, C. A., Styczyński, G., Sobczyńska, M., Milewska, A., Placha, G., & Kuch‐Wocial, A. (2015) · Journal of Human Hypertension · doi:10.1038/jhh.2015.35 · Cited by 9
Frank, D. U., Minich, L. L., Shaddy, R. E., & Tani, L. Y. (2002) · Journal of the American Society of Echocardiography · doi:10.1067/mje.2002.124575 · Cited by 9
Guha, K., Mantziari, L., Sharma, R., McDonagh, T. A., Gibson, D. G., & Duncan, A. (2012) · International Journal of Cardiology · doi:10.1016/j.ijcard.2012.09.035 · Cited by 9
A New Method to Make 24-Hour Urine Collection More Convenient: A Validity Study
Nabavizadeh, P., Ghadermarzi, S., & Fakhri, M. (2014) · International Journal of Nephrology · doi:10.1155/2014/718147 · Cited by 9
Moser, A. M. M., & Traebert, J. L. (2011) · Ciência & Saúde Coletiva · doi:10.1590/s1413-81232011000700070 · Cited by 16
Konzelmann, M., Burrus, C., Hilfiker, R., Rivier, G., Dériaz, O., & Lüthi, F. (2014) · Journal of Occupational Rehabilitation · doi:10.1007/s10926-014-9514-9 · Cited by 9
Crofton, P. M., Squires, N., Davidson, D. F., Henderson, P., & Taheri, S. (2008) · European Journal of Pediatrics · doi:10.1007/s00431-008-0733-y · Cited by 9
Kurth, F., Zinnow, F., Prakapenia, A., Dietl, S., Winkler, S., Ifflaender, S., Rüdiger, M., & Burkhardt, W. (2011) · PLoS ONE · doi:10.1371/journal.pone.0021003 · Cited by 9
A Simplified Coupled Soil-Pore Water Pressure Generation for Use in Site Response Analysis
Moreno-Torres, O., Hashash, Y. M. A., & Olson, S. M. (2010) · GeoFlorida 2010 · doi:10.1061/41095(365)314 · Cited by 9
Quantifying competitive swim training using accelerometer-based activity monitors
Wright, B. V., & Stager, J. M. (2013) · Sports Engineering · doi:10.1007/s12283-013-0123-1 · Cited by 9
Sakashita, C., Senserrick, T. M., Boufous, S., de Rome, L., Elkington, J., & Ivers, R. (2014) · Traffic Injury Prevention · doi:10.1080/15389588.2013.837576 · Cited by 12
Lezhou, W., Zhang, L., Ai, Z., Zou, L., Zhu, Y., Bao, Y., Li, J., Kang, S., Fan, H., Zhang, D., et al. (2012) · Journal of Hypertension · doi:10.1097/hjh.0b013e3283563418 · Cited by 12
Silva, E., Sitges, M., Doltra, A., Mont, L., Vidal, B., Castel, M., Tolosana, J. M., Berruezo, A., González‐Juanatey, J. R., & Brugada, J. (2010) · Heart Rhythm · doi:10.1016/j.hrthm.2010.06.034 · Cited by 9
Rapid Measurement of Blood Propofol Levels: a Proof of Concept Study
BAppSc, L. M., Voss, L. J., Oliver, R., Schaare, P. N., Barnard, J. P. M., & Sleigh, J. W. (2006) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-006-9014-3 · Cited by 9
Transesophageal Doppler Measurement of Renal Arterial Blood Flow Velocities and Indices in Children
Zabala, L. M., Ullah, S., Pierce, C. D., Gautam, N. K., Schmitz, M. L., Sachdeva, R., Craychee, J. A., Harrison, D., Killebrew, P., Bornemeier, R. A., et al. (2012) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e31824cb727 · Cited by 9
Modeling Breath-Enhanced Jet Nebulizers to Estimate Pulmonary Drug Deposition
Wee, W. B., Leung, K., & Coates, A. L. (2013) · Journal of Aerosol Medicine and Pulmonary Drug Delivery · doi:10.1089/jamp.2012.0984 · Cited by 9
Kato, S., Kitagawa, K., Yoon, Y. E., Nakajima, H., Nagata, M., Takase, S., Nakamori, S., Ito, M., & Sakuma, H. (2014) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2013.12.015 · Cited by 9
Pan, P., Chen, X., Li, Y., Zhang, Q., Zhao, X., Bodombossou-Djobo, M. M. A., & Yang, D. (2013) · PLoS ONE · doi:10.1371/journal.pone.0077095 · Cited by 9
Self-selected walking speed was consistent when recorded while using a cane
Weiss, C. O., Seplaki, C. L., Wolff, J. L., Kasper, J. D., & Agree, E. M. (2008) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2007.07.020 · Cited by 10
Reliability of peak O2 uptake and O2 uptake kinetics in step exercise tests in healthy subjects
Müller, P. D. T., Christofoletti, G., Zagatto, A. M., Paulin, F. V., & Neder, J. A. (2014) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2014.12.001 · Cited by 9
Fläring, U., Lönnqvist, P., Frenckner, B. P., Svensson, J. F., Ingolfsson, I., Wallensteen, L., Stigzelius, S., Kowalski, J. H., & Krmar, R. T. (2011) · BMC Pediatrics · doi:10.1186/1471-2431-11-61 · Cited by 9
Validation of Cartilage Thickness Calculations Using Indentation Analysis
Koff, M. F., Chong, L. R., Virtue, P., Chen, D., Wang, X., Wright, T. M., & Potter, H. G. (2010) · Journal of Biomechanical Engineering · doi:10.1115/1.4000989 · Cited by 9
Lunze, F. I., Lunze, K., McElhinney, D. B., Colan, S. D., Gauvreau, K., Lange, P., Schmitt, B., & Berger, F. F. (2013) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2013.06.016 · Cited by 9
Jose, B., Lodha, R., & Kabra, S. K. (2014) · The Indian Journal of Pediatrics · doi:10.1007/s12098-014-1381-z · Cited by 9
Mansencal, N., Martin, F., Farcot, J., Digne, F., Joseph, T., Pillière, R., Redheuil, A. B., Lacombe, P., & Dubourg, O. (2005) · International Journal of Cardiology · doi:10.1016/j.ijcard.2004.09.012 · Cited by 9
Validity of self-reports of knee-straining activities at work: a field study with 6-month follow-up
Ditchen, D. M., Ellegast, R. P., Hartmann, B. R., & Rieger, M. A. (2012) · International Archives of Occupational and Environmental Health · doi:10.1007/s00420-012-0758-4 · Cited by 9
Thanatophoric dysplasia. Correlation among bone X-ray morphometry, histopathology, and gene analysis
Pazzaglia, U. E., Donzelli, C., Izzi, C., Baldi, M., Gaetano, G. D., & Bondioni, M. P. (2014) · Skeletal Radiology · doi:10.1007/s00256-014-1899-1 · Cited by 9
Test/retest and inter‐test agreement of color aptitude measures
Anderson, A. J., & JOHNSTON, A. W. (2014) · Color Research & Application · doi:10.1002/col.21876 · Cited by 9
Ogbuehi, K. C., Mucke, S., & Osuagwu, U. L. (2012) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2012.00945.x · Cited by 9
Parikh, R., Patel, A., Stack, T., Socrate, S., & House, M. D. (2011) · Journal of Ultrasound in Medicine · doi:10.7863/jum.2011.30.9.1197 · Cited by 9
Júnior, E. A., y Novoa, V. A. N., Barros, F. S. B., Rocha, L. A., Peixoto, A. B., Martins, W. P., Nardozza, L. M. M., & Moron, A. F. (2015) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.3109/14767058.2015.1118454 · Cited by 10
Osuagwu, U. L., Alanazi, S. A., & Alanazi, M. A. (2013) · Clinical ophthalmology · doi:10.2147/opth.s43626 · Cited by 9
Waldau, T. E., Larsen, V., Parbst, H., & Bonde, J. (2002) · Acta Anaesthesiologica Scandinavica · doi:10.1034/j.1399-6576.2002.461012_46_10.x · Cited by 9
Kang, W.-S., Choi, J. W., Kang, J.-E., Chung, J. W., & Kim, S. (2013) · Journal of Cardiothoracic Surgery · doi:10.1186/1749-8090-8-98 · Cited by 9
Montagnani, L., Manca, G., Canepa, E., & Georgieva, E. (2010) · Agricultural and Forest Meteorology · doi:10.1016/j.agrformet.2010.01.013 · Cited by 9
Statistical Assessment of Analytical Method Transfer
Zhong, J., Lee, K., & Tsong, Y. (2008) · Journal of Biopharmaceutical Statistics · doi:10.1080/10543400802287347 · Cited by 9
Communication Group of the Spine Section of the French Society of Rheumatology, Mathy, C., Broonen, J.-P., Henrotin, Y. E., Marty, M., Legout, V., Genevay, S., Duplan, B., Bazin, T., Laroche, F., et al. (2011) · BMC Musculoskeletal Disorders · doi:10.1186/1471-2474-12-111 · Cited by 12
Anterior chamber depth measurement in teenagers. Comparison of two techniques
Bueno-Gimeno, I., Gregori, E. E., Gené‐Sampedro, A., Lanzagorta-Aresti, A., & Dualde-Beltrán, C. (2013) · Journal of Optometry · doi:10.1016/j.optom.2012.12.003 · Cited by 9
Effect of Ischemia on Implantable Defibrillator Intracardiac Shock Electrograms
Williams, J. L., Mendenhall, G. S., & Saba, S. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2007.01042.x · Cited by 9
Gupta, S., Sinha, G., Sharma, R., Nayak, B., Patil, B., Kashyap, B., Shameer, A., & Dada, T. (2015) · International Ophthalmology · doi:10.1007/s10792-015-0067-5 · Cited by 9
Cerón, J. M. C., Carli, E., Tasca, S., Martı́nez-Subiela, S., & Caldín, M. (2008) · American Journal of Veterinary Research · doi:10.2460/ajvr.69.9.1141 · Cited by 9
Muramatsu, T., a, H. M. G. I. A.-G. I., Lee, I. S., Bruining, N., Onuma, Y., & Serruys, P. W. J. C. (2012) · Circulation Journal · doi:10.1253/circj.cj-12-0536 · Cited by 9
Thomas, S., & Lincoln, N. B. (2008) · Disability and Rehabilitation · doi:10.1080/09638280701661430 · Cited by 9
Vijayalakshmi, K., Kunadian, B., Whittaker, V., Wright, R. A., Hall, J. A., Somasundram, U., Stewart, M. J., Sutton, A. G. C., Davies, A., & de Belder, M. (2007) · Acute Cardiac Care · doi:10.1080/17482940701305417 · Cited by 9
The repeatability of human dentine permeability measurement in vitro
Elgalaid, T. O., Creanor, S. L., Creanor, S., & Hall, A. F. (2007) · Journal of Dentistry · doi:10.1016/j.jdent.2007.10.005 · Cited by 9
Seuss, C. R., Kim, M. J., Triolo, M. J., Hajdu, C. H., & Rosenkrantz, A. B. (2014) · American Journal of Roentgenology · doi:10.2214/ajr.13.11688 · Cited by 9
Biedler, A., Schneider, S., Bach, F., Soltész, S., Wilhelm, W., Ziegeler, S., & Kreuer, S. (2007) · The Open Anesthesiology Journal · doi:10.2174/1874321800701010001 · Cited by 9
Lisbona, M., Maymó, J., Solano, A., Almirall, M., Navallas, M., Ares, J., & Abelló, J. C. (2013) · Scandinavian Journal of Rheumatology · doi:10.3109/03009742.2013.776104 · Cited by 11
Bode, A. S., Leermakers, J., Kroon, J. W., Brands, P. J., Planken, R. N., & Tordoir, J. H. M. (2011) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfr687 · Cited by 9
Evaluation of the SenseWear Mini Armband to Assess Energy Expenditure During Pole Walking
Vernillo, G., Savoldelli, A., Pellegrini, B., & Schena, F. F. (2014) · International Journal of Sport Nutrition and Exercise Metabolism · doi:10.1123/ijsnem.2014-0075 · Cited by 9
Tidal breathing FeNO measurements: A new algorithm
van Mastrigt, E., de Groot, R. C. A., van Kesteren, H. W., Vink, A. J., de Jongste, J. C., & Pijnenburg, M. W. H. (2013) · Pediatric Pulmonology · doi:10.1002/ppul.22782 · Cited by 9
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.