STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 30,901–31,000 of 47,868
Valero, M. M., Verstockt, S., Mata, C., Jimenez, D., Queen, L. P., Rios, O., Pastor, E., & Planas, E. (2020) · Remote Sensing · doi:10.3390/rs12030540 · Cited by 11
Three-Dimensional Stereophotogrammetry Assessment of Facial Asymmetry in Facial Palsy
van Veen, M. M., ten Berge, J. H. A., Werker, P. M. N., & Dijkstra, P. U. (2020) · Journal of Craniofacial Surgery · doi:10.1097/scs.0000000000006192 · Cited by 9
Murphy, M., Gibson, W., Chivers, P., Docking, S., & Rio, E. (2020) · British Journal of Pain · doi:10.1177/2049463720912208 · Cited by 11
Through-Wall Heartbeat Frequency Detection Using Ultra-Wideband Impulse Radar
Sarkar, A., & Ghosh, D. (2019) · International Conference on Range Technology (ICORT) · doi:10.1109/icort46471.2019.9069632 · Cited by 9
Bort‐Roig, J., Chirveches-Pérez, E., Cuyàs, F. G., Dowd, K., & Puig-Ribera, A. M. (2020) · JMIR mhealth and uhealth · doi:10.2196/15338 · Cited by 10
Hou, J., Li, Q., Yu, M., Li, F., Tang, Y., Long, Y., Alike, Y., Zhang, Y., Ali, M. I., Zhang, C., et al. (2020) · JMIR mhealth and uhealth · doi:10.2196/16758 · Cited by 9
The assessment of esophageal pressure using different devices: a validation study
Chiumello, D., Caccioppola, A., Pozzi, T., Lusardi, A. C., Giorgis, V. D., Galanti, V., Ferrari, E., & Coppola, S. (2020) · Minerva Anestesiologica · doi:10.23736/s0375-9393.20.14458-4 · Cited by 10
A Comparison of Applanation and Rebound Tonometers in Young Chicks
Ostrin, L. A., & Wildsoet, C. F. (2020) · Current Eye Research · doi:10.1080/02713683.2020.1782942 · Cited by 9
MRI Monitoring of Residual Vestibular Schwannomas: Modeling and Predictors of Growth
Fieux, M., Zaouche, S., Rabasté, S., Riche, B., Maucort‐Boulch, D., & Tringali, S. (2020) · Otology & Neurotology · doi:10.1097/mao.0000000000002742 · Cited by 9
Bass, A., Brosseau, R., Décary, S., Gauthier, C., & Gagnon, D. H. (2020) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0000000000001534 · Cited by 9
Full Finger Reperfusion Time Measured by Pulse Oximeter Waveform Analysis in Children
Nickel, A. J., Jiang, S., Napolitano, N., Yehya, N., Fitzgerald, J. C., Bruins, B. B., Lockman, J. L., Nadkarni, V., & Nishisaki, A. (2020) · Critical Care Medicine · doi:10.1097/ccm.0000000000004506 · Cited by 9
Andreu‐Caravaca, L., Ramos‐Campo, D. J., Abellán‐Aynés, O., & Rubio‐Arias, J. Á. (2020) · Journal of Clinical Medicine · doi:10.3390/jcm9082458 · Cited by 9
Validation of a Mathematical Procedure for the Cobb Angle Assessment Based on Photogrammetry
Navarro, I. J. R. L., Candotti, C. T., Furlanetto, T. S., Dutra, V. H., do Amaral, M. A., & Loss, J. F. (2019) · Journal of Chiropractic Medicine · doi:10.1016/j.jcm.2019.01.001 · Cited by 10
Fujii, T., & Nishiwaki, K. (2020) · Pediatric Anesthesia · doi:10.1111/pan.14020 · Cited by 9
Use of Magneto Plethysmogram Sensor for Real-Time Estimation of Hemoglobin Concentration
Bai, J. R., & Kumar, V. J. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3029179 · Cited by 9
A 24-segment fractional shortening of the fetal heart using FetalHQ
Hata, T., Koyanagi, A., Yamanishi, T., Bouno, S., Takayoshi, R., AboEllail, M. A. M., & Miyake, T. M. (2020) · Journal of Perinatal Medicine · doi:10.1515/jpm-2020-0246 · Cited by 9
Studying bone mineral density in young people: The complexity of choosing a pQCT reference database
Lalayiannis, A. D., Fewtrell, M. S., Biassoni, L., Silva, S., Goodman, N., Shroff, R. C., & Crabtree, N. J. (2020) · Bone · doi:10.1016/j.bone.2020.115713 · Cited by 10
Usowicz, B., Łukowski, M., & Lipiec, J. (2020) · Scientific Reports · doi:10.1038/s41598-020-75475-x · Cited by 9
Choroidal Thickness in Indigenous Australian Children
Read, S. A., Cox, R. A., Alonso‐Caneiro, D., Hopkins, S., & Wood, J. M. (2020) · Translational Vision Science & Technology · doi:10.1167/tvst.9.12.28 · Cited by 9
Šarabon, N., Čeh, T., Kozinc, Ž., & Smajla, D. (2020) · The Knee · doi:10.1016/j.knee.2020.09.023 · Cited by 11
Maximum Expected Information Approach for Improving Efficiency of Categorical Loudness Scaling
Fultz, S. E., Neely, S. T., Kopun, J. G., & Rasetshwane, D. M. (2020) · Frontiers in Psychology · doi:10.3389/fpsyg.2020.578352 · Cited by 10
Corneal thickness evaluation in healthy eyes: Comparison between two different Scheimpflug devices
Rosa, N., Bernardo, M. D., Pepe, A., Vitiello, L., Marotta, G., Imparato, R., & Capasso, L. (2020) · PLoS ONE · doi:10.1371/journal.pone.0243370 · Cited by 9
Hauk, C., Schäfermann, S., Martus, P., Muzafarova, N., Babaley, M., Waning, B., & Heide, L. E. (2020) · PLoS ONE · doi:10.1371/journal.pone.0243428 · Cited by 10
Yoshikawa, N., Yamada, A. Y., Yokota, T., Moritake, H., Hirabara, Y., & Ikeda, R. (2020) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.23661 · Cited by 9
Comparison and calibration of 24‐hour physical activity recall in adult population
Borges, L. P. S. L., Ries, D., Sousa, A. G., & da Costa, T. H. M. (2021) · European Journal of Sport Science · doi:10.1080/17461391.2020.1866077 · Cited by 12
Validation of a point-of-care handheld blood total calcium analyzer in postpartum dairy cows
Serrenho, R. C., Bruinjé, T. C., Morrison, E. I., Renaud, D. L., DeVries, T. J., Duffield, T. F., & LeBlanc, S. J. (2020) · JDS Communications · doi:10.3168/jdsc.2020-0006 · Cited by 9
Takada, T., Inokuchi, R., Kim, H., Sasaki, S., Terada, K., Yokota, H., Hattori, S., Mikami, W., Kubota, T., & Fukuhara, S. (2020) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2020.12.066 · Cited by 11
NEUROMUSCULAR CONTROL IN LUMBAR DISORDERS
Leinonen, V. (2004) · DOAJ (DOAJ: Directory of Open Access Journals) · Cited by 9
Nösslinger, H., Mair, E., Toplak, H., & Hörmann-Wallner, M. (2021) · Clinical Nutrition Open Science · doi:10.1016/j.nutos.2021.01.003 · Cited by 12
An Emerging Method to Assess Tear Film Spread and Dynamics as Possible Tear Film Homeostasis Markers
García‐Marqués, J. V., Talens‐Estarelles, C., Martínez-Albert, N., García‐Lázaro, S., & Cerviño, A. (2021) · Current Eye Research · doi:10.1080/02713683.2021.1887270 · Cited by 9
Application of the Modified Incremental Step Test for Pulmonary Rehabilitation
Burge, A. T., Rodrigues, J. C., Jr., Abramson, M. J., Cox, N. S., Bondarenko, J., Webb, E., Marceau, T., Handley, E., Macdonald, H., Askin, A., et al. (2021) · Physical Therapy · doi:10.1093/ptj/pzab044 · Cited by 9
Chatziralli, I., THEODOSSIADIS, G. P., Chatzirallis, A., Dimitriou, E., Parikakis, E., & THEODOSSIADIS, P. G. (2021) · European Journal of Ophthalmology · doi:10.1177/1120672121992984 · Cited by 9
Rodríguez‐Rodríguez, A. E., Lima, S. L., Donate‐Correa, J., Martin, L. D., Arnau, M. R., Jiménez, A., Gaspari, F., Ortíz, A., & Porrini, E. (2021) · Scientific Reports · doi:10.1038/s41598-021-83934-2 · Cited by 9
Evaluation of Blood Glucose and Lactate Concentrations in Mule and Equine Foals
Boakari, Y. L., Alonso, M. A., Riccio, A. V., Affonso, F. J., Losano, J. D. D. A., Nichi, M., Belli, C. B., & Fernandes, C. B. (2021) · Journal of Equine Veterinary Science · doi:10.1016/j.jevs.2020.103369 · Cited by 9
Low-Cost, Smartphone-Based Specular Imaging and Automated Analysis of the Corneal Endothelium
Mantena, S., Chandra, J., Pecyna, E., Zhang, A., Garrity, D., Tone, S. O., Sastry, S. M., Uddaraju, M., & Jurkunas, U. V. (2021) · Translational Vision Science & Technology · doi:10.1167/tvst.10.4.4 · Cited by 9
Two-Year Responses of Heart Rate and Heart Rate Variability to First Occupational Lead Exposure
Yu, Y., Thijs, L., Yu, C., Yang, W., Melgarejo, J. D., Wei, D., Wei, F., Nawrot, T. S., Verhamme, P. B., Roels, H. A., et al. (2021) · Hypertension · doi:10.1161/hypertensionaha.120.16545 · Cited by 10
Lee, D., Tanikawa, C., & Yamashiro, T. (2021) · PLoS ONE · doi:10.1371/journal.pone.0249961 · Cited by 9
Fontbonne, A., Maenhoudt, C., Thoumire, S., Roos, J., Niewiadomska, Z., Robiteau, G., Rousselière, E., & Buronfosse, T. (2021) · American Journal of Veterinary Research · doi:10.2460/ajvr.82.5.417 · Cited by 9
Trost, J. P., Chen, M., Stark, M. M., Hodges, J. S., Richter, S. A., Lindsay, A., Warren, G. L., Lowe, D. A., & Kimberley, T. J. (2021) · Muscle & Nerve · doi:10.1002/mus.27323 · Cited by 9
Recker, F., Jin, L., Veith, P., Lauterbach, M., Karakostas, P., & Schäfer, V. S. (2021) · Diagnostics · doi:10.3390/diagnostics11061106 · Cited by 10
Crombé, A., Gauquelin, L., Nougaret, S., Chicart, M., Pulido, M., Floquet, A., Guyon, F., Croce, S., Kind, M., & Cazeau, A. L. (2021) · Diagnostic and Interventional Imaging · doi:10.1016/j.diii.2021.05.007 · Cited by 9
Validation of the Canadian Occupational Performance Measure in Italian Parkinson’s Disease Clients
Bianchini, E., Gatta, F. D., Virgilio, M., Alborghetti, M., Salvetti, M., Giubilei, F., & Pontieri, F. E. (2021) · Physical & Occupational Therapy In Geriatrics · doi:10.1080/02703181.2021.1942392 · Cited by 13
Automated analysis of corneal nerve tortuosity in diabetes: implications for neuropathy detection
Klisser, J., Tummanapalli, S. S., Kim, J., Chiang, J. C. B., Khou, V., Issar, T., Naduvilath, T. J., Poynten, A. M., Markoulli, M. P., & Krishnan, A. V. (2021) · Clinical and Experimental Optometry · doi:10.1080/08164622.2021.1940875 · Cited by 9
Radicioni, M., Massetti, V., Bini, V., & Troiani, S. (2021) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.1080/14767058.2021.1933935 · Cited by 10
Fassaert, L. M. M., Plate, J. D. J., Westerink, J., Immink, R. V., & de Borst, G. J. (2021) · American Journal of Hypertension · doi:10.1093/ajh/hpab140 · Cited by 9
Tsunemi, A., Sato, J., Sugimoto, S., Iwagaki, Y., Enomoto, M., Someya, Y., Kiya, M., Matsuhashi, E., Wakabayashi, Y., Funayama, T., et al. (2021) · Journal of Clinical Medicine Research · doi:10.14740/jocmr4558 · Cited by 10
Evertz, R., Hub, S., Backhaus, S. J., Lange, T., Toischer, K., Kowallick, J. T., Hasenfuss, G. P., & Schuster, A. (2021) · Journal of Clinical Medicine · doi:10.3390/jcm10173970 · Cited by 10
Tardif, J. C., Dickson, H., Conciatori, F., Nolin, A. F., & Bergeron, Y. (2021) · Dendrochronologia · doi:10.1016/j.dendro.2021.125889 · Cited by 9
Covin, M. A., Gomez, R. R., Suchodolski, J. S., Steiner, J. M., & Lidbury, J. A. (2021) · PubMed · Cited by 16
Utility of plasma cell-free DNA for de novo detection and quantification of clonal hematopoiesis
Gutierrez‐Rodrigues, F., Beerman, I., Groarke, E. M., Patel, B. A., Spitofsky, N., Dillon, L. W., Raffo, D. Q., Hourigan, C. S., Kajigaya, S., Ferrucci, L., et al. (2021) · Haematologica · doi:10.3324/haematol.2021.279230 · Cited by 10
Full liberation of 2-Aminopurine with nucleases digestion for highly sensitive biosensing
Li, X., Yang, H., He, J., Yang, B., Zhao, Y., & Wu, P. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113721 · Cited by 9
Takagi, S., Suzuki, T., Nakatsuka, H., Sasakawa, T., Iwasaki, H., Kotake, Y., Nagata, E., & Kanmura, Y. (2021) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-021-00768-z · Cited by 9
Muntean, P., Micloș-Balica, M., Popa, A., Neagu, A., & Neagu, M. (2021) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph182010693 · Cited by 14
Experimental Validation of Real-Time Ski Jumping Tracking System Based on Wearable Sensors
Link, J., Guillaume, S., & Eskofier, B. M. (2021) · Sensors · doi:10.3390/s21237780 · Cited by 9
Engelmaier, A., & Weber, A. (2021) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2021.114476 · Cited by 10
Shyu, C., Elsaid, S., Truong, P., Chavez, S., & Foll, B. L. (2021) · Brain Sciences · doi:10.3390/brainsci11111538 · Cited by 10
Liebich, T., Lack, L. C., Micic, G., Hansen, K. L., Zajamšek, B., Dunbar, C., Lechat, B., Scott, H., Lovato, N., Decup, F., et al. (2021) · SLEEP · doi:10.1093/sleep/zsab283 · Cited by 9
Marfeo, E. E., Ni, P., Wang, C., Weiss, D. J., & Cheville, A. L. (2021) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2021.12.002 · Cited by 9
Méndez‐González, J., Bonet, R., & Ordóñez‐Llanos, J. (2010) · Point of Care The Journal of Near-Patient Testing & Technology · doi:10.1097/poc.0b013e3181d9f3cc · Cited by 10
Watanabe, H., Washio, T., Saito, S., Hirasawa, A., Suzuki, R., Shibata, S., Brothers, R. M., & Ogoh, S. (2022) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-022-00817-1 · Cited by 10
Bukhari, S. H. A., Sánchez, C., Srinivasan, S., Palmieri, F., Potse, M., Laguna, P., & Pueyo, E. (2022) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2022.105304 · Cited by 10
Measuring Foot Progression Angle during Walking Using Force-Plate Data
Caderby, T., Begue, J., Dalleau, G., & Peyrot, N. (2022) · Applied Mechanics · doi:10.3390/applmech3010013 · Cited by 9
Puri, T., & Blake, G. M. (2022) · British Journal of Radiology · doi:10.1259/bjr.20210378 · Cited by 10
Ferre-Fernández, M., Murcia-González, M. A., & Díaz, J. R. (2022) · Pediatric Physical Therapy · doi:10.1097/pep.0000000000000874 · Cited by 9
Lardé, H., Francoz, D., Roy, J., Archambault, M., Massé, J., Paradis, M.-È., & Dufour, S. (2021) · Microorganisms · doi:10.3390/microorganisms9091834 · Cited by 9
Law, E. M., Buckhurst, H. D., Aggarwal, R. K., Kasaby, H. E., Marsden, J. F., Shum, G. L. K., & Buckhurst, P. J. (2022) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12986 · Cited by 9
Bukhari, S. H. A., Sánchez, C., Ruiz, J. E., Potse, M., Laguna, P., & Pueyo, E. (2022) · Sensors · doi:10.3390/s22082951 · Cited by 9
Ripley, N. J., Comfort, P., & McMahon, J. J. (2022) · Measurement in Physical Education and Exercise Science · doi:10.1080/1091367x.2022.2063689 · Cited by 10
Louati, A., Bouche, P. A., Bauer, T., & Hardy, A. (2022) · Journal of Experimental Orthopaedics · doi:10.1186/s40634-022-00470-2 · Cited by 10
Amorin-Woods, L., Woods, B. L., Moore, C., Leach, M., Kawchuk, G. N., & Adams, J. (2022) · Journal of Manipulative and Physiological Therapeutics · doi:10.1016/j.jmpt.2022.03.015 · Cited by 13
Senden, R. H. J., Marcellis, R. G. J., Meijer, K., Willems, P. J. B., Lenssen, A. F., Staal, H. M., Janssen‐Potten, Y., Groen, V., Vermeulen, R. J., & Witlox, A. M. A. (2022) · PeerJ · doi:10.7717/peerj.13752 · Cited by 9
Habersack, A., Zussner, T., Thaller, S., Tilp, M., Švehlík, M., & Kruse, A. (2022) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-022-07076-2 · Cited by 9
Cáñez-Ríos, M., Esparza‐Romero, J., González-Arellanes, R., Ramírez-Torres, M., Figueroa-Pesqueira, G., Urquídez-Romero, R., Peniche, D. B. R., & Alemán-Mateo, H. (2022) · Frontiers in Nutrition · doi:10.3389/fnut.2022.951346 · Cited by 10
Validation of StepTest4all for Assessing Cardiovascular Capacity in Young Adults
Bragada, J. A. A., Bartolomeu, R. F., Rodrigues, P. M., Rodrigues, P. M. M., Bragada, J. P., & Morais, J. E. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph191811274 · Cited by 15
Assessment of Cranial Deformation Indices by Automatic Smartphone-Based Photogrammetric Modelling
Baselga, S., Mora-Navarro, G., & Lerma, J. L. (2022) · Applied Sciences · doi:10.3390/app122211499 · Cited by 9
Collard, D., Westerhof, B. E., Karemaker, J. M., Stok, W. J., Postema, P. G., Krediet, C. T. P., Vogt, L., & van den Born, B. H. (2023) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-023-02768-4 · Cited by 9
Heimann, A. F., Schwab, J. M., Popa, V., Guoyan Zheng, A., & Tannast, M. (2023) · Journal of Orthopaedic Research® · doi:10.1002/jor.25521 · Cited by 9
Evaluation of a visual acuity eHealth tool in patients with cataract
Wanten, J. C., Bauer, N. J. C., Claessens, J. L. J., van Amelsfort, T., Berendschot, T. T. J. M., Wisse, R. P. L., & Nuijts, R. M. M. A. (2022) · Journal of Cataract & Refractive Surgery · doi:10.1097/j.jcrs.0000000000001108 · Cited by 9
Reliable capillary sampling of carcinoembryonic antigen at home: the CASA feasibility study
Voigt, K. R., Wullaert, L., Verhoef, C. K., Grünhagen, D. J., & Ramakers, C. R. B. (2023) · Colorectal Disease · doi:10.1111/codi.16536 · Cited by 9
Satoh, M., Yoshida, T., Metoki, H., Murakami, T., Tatsumi, Y., Hirose, T., Takabatake, K., Tsubota‐Utsugi, M., Hara, A., Nomura, K., et al. (2023) · Scientific Reports · doi:10.1038/s41598-023-31861-9 · Cited by 14
Mandigers, T. J., Conti, M., Allievi, S., Dedola, F., Bissacco, D., Bianchi, D., Marconi, S., Domanin, M., van Herwaarden, J. A., Auricchio, F., et al. (2023) · EJVES Vascular Forum · doi:10.1016/j.ejvsvf.2023.04.001 · Cited by 9
Kheram, N., Boraschi, A., Pfender, N., Spiegelberg, A., Kurtcuoglu, V., Curt, A. E. P., Schubert, M. J. W., & Zipser, C. M. (2023) · Acta Neurochirurgica · doi:10.1007/s00701-023-05583-w · Cited by 9
Kreuder, A. J., Breuer, R., Wiley, C., Dohlman, T. M., Smith, J. S., & McKeen, L. A. (2023) · Journal of Veterinary Internal Medicine · doi:10.1111/jvim.16831 · Cited by 9
Santos, C. C., Costa, M. J., Forte, P. M., & Marinho, D. A. (2023) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2023.111815 · Cited by 9
Barroso-García, V., Fernández-Poyatos, M., Sahelices, B., Álvarez, D., Gozal, D., Hornero, R., & Gutiérrez‐Tobal, G. C. (2023) · Diagnostics · doi:10.3390/diagnostics13203187 · Cited by 13
Reliability of the serial reaction time task: If at first you don’t succeed, try, try, try again
Oliveira, C. M., Hayiou‐Thomas, M. E., & Henderson, L. M. (2024) · Quarterly Journal of Experimental Psychology · doi:10.1177/17470218241232347 · Cited by 12
Schneider, M., Borgulya, G., Seres, A., Nagy, Z. Z., & Németh, J. (2009) · European Journal of Ophthalmology · doi:10.1177/112067210901900202 · Cited by 9
Manifest refraction versus autorefraction for patients with subfoveal choroidal neovascularization.
Orr, P. R., Cramer, L. D., Hawkins, B. S., & Bressler, N. M. (2001) · PubMed · Cited by 9
Digital signature to help network management using flow analysis
Proença, M. L., Fernandes, G., Carvalho, L. F., de Assis, M. V. O., & Rodrigues, J. J. P. C. (2015) · International Journal of Network Management · doi:10.1002/nem.1892 · Cited by 15
Vibration signals of snoring as a simple severity predictor for obstructive sleep apnea
Wu, H., Pan, W., Liu, A., Su, M., Chen, H., Tsai, I., Lin, M., & Sun, C. (2014) · The Clinical Respiratory Journal · doi:10.1111/crj.12237 · Cited by 9
Triboulet, J., Nasr, E., Poignet, P., Dombre, E., & Dauzat, M. (2006) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2006.260219 · Cited by 9
Comparison of two field methods for estimating body fat in different spanish dance disciplines.
Alvero‐Cruz, J. R., Marfell‐Jones, M., Alacid, F., Orta, P. A., Correas-Gómez, L., Medina, F. S., & Carnero, E. Á. (2014) · PubMed · doi:10.3305/nh.2014.30.3.7240 · Cited by 15
Quality of Life (QoL) in Glaucoma Patients
Labiris, G., Giarmoukakis, A., & Vassilios, P. (2011) · InTech eBooks · doi:10.5772/25122 · Cited by 12
Qualitative echocardiography parameters for prediction of pulmonary hypertension
Lange, T. J., Baumgartner, S., Arzt, M. E., & Pfeifer, R. (2013) · International Journal of Clinical Practice · doi:10.1111/ijcp.12068 · Cited by 9
Einfluss der stromalen Restdicke nach myoper LASIK auf die Messung des Augeninnendrucks
Muller, L., & Kohnen, T. (2009) · Der Ophthalmologe · doi:10.1007/s00347-008-1885-x · Cited by 9
Mhajna, M., & Abboud, S. (2013) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.2550 · Cited by 9
Yamada, Y., Jinzaki, M., Niijima, Y., Hashimoto, M., Yamada, M., Abe, T., & Kuribayashi, S. (2015) · American Journal of Roentgenology · doi:10.2214/ajr.14.13411 · Cited by 9
Win, T., Pearce, L., Nathan, J. A., Cafferty, F. H., & LAROCHE, C. M. (2008) · Canadian Respiratory Journal · doi:10.1155/2008/129070 · Cited by 9
Constantinescu, T., Magda, S. L., Niculescu, R., Mincu, R. I., Zaharia, D. C., Toma, C., Cintezǎ, M., & Bogdan, M. A. (2013) · Europe PMC (PubMed Central) · Cited by 9
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.