STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 31,101–31,200 of 47,868
Rooney, T. P., Edwards, C. K., Gogarty, M., Greenan, L., Veale, D. J., FitzGerald, O., Dayer, J., & Bresnihan, B. (2009) · Rheumatology International · doi:10.1007/s00296-009-1191-1 · Cited by 10
Selleri, P., & Girolamo, N. D. (2014) · Journal of the American Animal Hospital Association · doi:10.5326/jaaha-ms-6114 · Cited by 9
Corchia, C., Balata, A., Soletta, G., Mastroni, P., & Meloni, T. (1994) · Early Human Development · doi:10.1016/0378-3782(94)90220-8 · Cited by 9
Sim, M., Kim, M. J., Jeong, I., Park, S., Yong, S. J., Kim, W. H., & Yoon, H. (2013) · Sensors · doi:10.3390/s131115846 · Cited by 9
Richards, D. R., Gilliland, Y. E., Bernal, J. A., Smart, F. W., Stapleton, D. D., Ventura, H. O., & Cheirif, J. B. (1998) · American Heart Journal · doi:10.1016/s0002-8703(98)70280-7 · Cited by 9
Furber, A., Lethimonnier, F., Jeune, J. L., Balzer, P., JALLET, P., Tadeï, A., & Geslin, P. (1999) · The American Journal of Cardiology · doi:10.1016/s0002-9149(99)00186-1 · Cited by 9
ANTIBODY ARRAY–BASED IMMUNOSENSOR FOR DETECTING CARDIOVASCULAR DISEASE RISK MARKERS
Timuçin, A. C., Gül, Ö., Kütük, Ö., & Başağa, H. (2012) · Journal of Immunoassay and Immunochemistry · doi:10.1080/15321819.2011.638407 · Cited by 9
Treadmill Adaptation and Verification of Self-Selected Walking Speed: A Protocol for Children
Amorim, P. R. D. S., Hills, A. P., & Byrne, N. M. (2009) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2009.10599574 · Cited by 11
Onorati, P., Martolini, D., Ora, J., Valli, G., Fedeli, A., & Palange, P. (2008) · European Journal of Applied Physiology · doi:10.1007/s00421-008-0777-8 · Cited by 9
Bruder, O., Jochims, M., Hunold, P., Jensen, C. J., Forsting, M., Sabin, G. V., Barkhausen, J., & Schlosser, T. W. (2009) · Acta Radiologica · doi:10.1080/02841850902902540 · Cited by 9
Sullivan, C. M., Chakraverty, J. K., Foley, K., Narayanaswamy, S., & Kamath, S. (2013) · Acta Radiologica · doi:10.1177/0284185113481592 · Cited by 9
Caterino, M., Casadei, G. M., Arvonio, R., Francia, S. D., Pirro, E., Piccione, F. M., Pane, F., & Ruoppolo, M. (2012) · International Journal of Peptide Research and Therapeutics · doi:10.1007/s10989-012-9321-0 · Cited by 9
Newborn infant characteristics and risk of future rheumatoid arthritis: a twin-control study
Svendsen, A. J., Kyvik, K. O., Houen, G., Nielsen, C., Holst, R., Skytthe, A., & Junker, P. (2013) · Rheumatology International · doi:10.1007/s00296-013-2886-x · Cited by 9
Boddu, K., Siebachmeyer, M., Lakkol, S., Rajayogeswaran, B., Kavarthapu, V., & Li, P. L. S. (2013) · The Journal of Arthroplasty · doi:10.1016/j.arth.2013.12.017 · Cited by 9
Uritani, D. (2013) · Journal of Physical Therapy Science · doi:10.1589/jpts.25.1181 · Cited by 9
Ribeiro, M. S. M., Pereira, C. A. C., Nery, L. E., Beppu, O. S., & Silva, C. O. S. (2008) · Allergy · doi:10.1111/j.1398-9995.2007.01589.x · Cited by 9
Pascuala Urrejola, N., María Isabel Hernández, C., Icaza, G., Velandia, S., Reyes, M. L., & B, M. I. H. (2011) · Revista chilena de pediatría · doi:10.4067/s0370-41062011000600004 · Cited by 9
Comparação de técnicas não invasivas para medir a pressão arterial em recém-nascidos
Ribeiro, M. A. D. S., Fiori, H. H., Luz, J. H., Piva, J. P., Ribeiro, N. M. E., & Fiori, R. M. (2011) · Jornal de Pediatria · doi:10.1590/s0021-75572011000100010 · Cited by 9
Vadikolias, Κ., Artemis, N., Mitsias, P. D., Heliopoulos, J., Trιpsianis, G., Vadikolia, C. M., Proios, H. S., Serdari, A., Piperidou, C., & Milonas, I. A. (2007) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/sj.jcbfm.9600484 · Cited by 9
Erb, T. O., Craig, D. M., Gaskin, P. M., Cheifetz, I. M., Bengur, A. R., & Sanders, S. P. (2002) · Critical Care Medicine · doi:10.1097/00003246-200211000-00022 · Cited by 9
Ho, W. M., Yang, N. C., Wong, K. C., & Hwang, K. L. (2004) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000139344.61634.ef · Cited by 9
Díaz, J. R., Ferrando, A. D. G., Payá, J. J. M., & Aledo, M. E. D. B. (2010) · Reumatología Clínica · doi:10.1016/j.reuma.2010.01.008 · Cited by 9
Gowrishankar, M., VanderPluym, C. J., Robert, C., Bamforth, F. J., Gilmour, S. M., & Senthilselvan, A. (2014) · Pediatric Transplantation · doi:10.1111/petr.12381 · Cited by 12
Koch, W., Süßmair, C., Tatsch, K., & Pöpperl, G. (2011) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-011-1737-9 · Cited by 11
Respiratory mechanics in sedated and nonsedated adult llamas
Lascola, K. M., Hoffman, A. M., Mazan, M. R., & Bedenice, D. (2007) · American Journal of Veterinary Research · doi:10.2460/ajvr.68.6.676 · Cited by 9
Lal, B. K., Cerveira, J. J., Seidman, C. S., Haser, P. B., Kubicka, R., Jamil, Z., Padberg, F. T., Hobson, R. W., & Pappas, P. J. (2004) · Annals of Vascular Surgery · doi:10.1007/s10016-004-0102-x · Cited by 9
A technique to assess body composition and sarcopenia using DXA: application for an obese population
Evans, E. M., Misic, M. M., & Mallard, D. M. (2009) · European Journal of Clinical Nutrition · doi:10.1038/ejcn.2009.128 · Cited by 10
One- and two-step non-competitive avidin-biotin immunoassays for monomeric and heterodimeric antigen
Vilja, P. J. (1991) · Journal of Immunological Methods · doi:10.1016/0022-1759(91)90252-b · Cited by 9
Arnold, P. A., Ellerbrock, E. R., Bowman, L., & Loucks, A. B. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.09.005 · Cited by 9
Antegrade late diastolic arterial blood flow in the fetus: insight into fetal atrial function
Howley, L. W., Yamamoto, Y., Sonesson, S., Sekar, P., Jain, V., Motan, T., Savard, W., Wagner, B. D., Trines, J., & Hornberger, L. K. (2013) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2013.02.053 · Cited by 9
A comparison of methodologies for measuring glucose concentrations in the horse
Slough, T. L., Gunkel, C. D., Murray, L. W., & Drouillard, J. S. (2011) · The Professional Animal Scientist · doi:10.15232/s1080-7446(15)30475-7 · Cited by 9
Moura, C., Fontes-Sousa, A. P., Teixeira-Pinto, A. M., Areias, J. C., & Leite-Moreira, A. F. (2009) · American Journal of Veterinary Research · doi:10.2460/ajvr.70.4.464 · Cited by 9
Trip, S. A., Schlottmann, P. G., JONES, S. J., Kallis, C., Altmann, D. R., Garway‐Heath, D. F., Thompson, A. J., Plant, G. T., & Miller, D. H. (2010) · Journal of Neuro-Ophthalmology · doi:10.1097/wno.0b013e3181dbfeac · Cited by 9
An improved sequencing-based strategy to estimate locus-specific DNA methylation
Brisotto, G., di Gennaro, A., Damiano, V., Armellin, M., Perin, T., Maestro, R., & Santarosa, M. (2015) · BMC Cancer · doi:10.1186/s12885-015-1646-6 · Cited by 11
Proyección de Rosenberg en la evaluación radiológica de la osteoartrosis de rodilla
Fontboté, C. A., Nemtala, F., Óscar Contreras, O., & Guerrero, R. (2008) · Revista médica de Chile · doi:10.4067/s0034-98872008000700009 · Cited by 9
Resende, M., Venturini, C., Penido, M., Bicalho, L., Peixoto, G., & Chagas, M. (2006) · Brazilian Journal of Physical Therapy · doi:10.1590/s1413-35552006000200010 · Cited by 9
Dynamics of interpedicular widening in spinal burst fractures: an in vitro investigation
Brandolini, N., Kapur, N., & Hall, R. M. (2014) · The Spine Journal · doi:10.1016/j.spinee.2014.01.058 · Cited by 9
Heydenreich, J., Otto, C., Mayer, F., & Carlsohn, A. (2014) · Journal of Nutrition and Metabolism · doi:10.1155/2014/478324 · Cited by 9
The assessment of flow-mediated dilation (FMD) of the brachial artery
Bianchini, E., Faita, F., Gemignani, V., Giannoni, M. F., & Demi, M. (2006) · Cited by 9
Persico, N., Fabietti, I., Baffero, G. M., Fedele, L., & Nicolaides, K. H. (2013) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.13192 · Cited by 9
Manouras, A., Shala, A., Nyktari, E. G., Shahgaldi, K., Winter, R., Vardas, P., Brodin, L., & Nowak, J. (2009) · Cardiovascular Ultrasound · doi:10.1186/1476-7120-7-29 · Cited by 9
Quality Control of the Ambulatory Polygraphy Using Automatic Analysis
LÓPEZ, F. J., Fernández-Suarez, B., Guardiola-Martínez, J., Lahuerta, I. V., Latour-Pérez, J., & Cruz, M. L. (2008) · CHEST Journal · doi:10.1378/chest.08-0165 · Cited by 10
Ueda, Y., Hozumi, T., Yoshida, K., Watanabe, H., Akasaka, T., Takagi, T., Yamamuro, A., Homma, S., & Yoshikawa, J. (2002) · Heart · doi:10.1136/heart.88.3.278 · Cited by 9
Effect of inhaled carbon dioxide on laryngeal abduction
Cheetham, J., Jones, A. K., & Martin‐Flores, M. (2014) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00469.2014 · Cited by 9
Suprasternal Doppler ultrasound for assessment of stroke distance
Childs, C., Goldring, S., Tann, W., & Hillier, V. F. (1998) · Archives of Disease in Childhood · doi:10.1136/adc.79.3.251 · Cited by 9
Smeets, R., & van Soest, M. (2009) · Disability and Rehabilitation · doi:10.3109/09638280902874162 · Cited by 9
Endothelial barrier dysfunction in diabetic conduit arteries: a novel method to quantify filtration
Lu, X., Huxley, V. H., & Kassab, G. S. (2012) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00550.2012 · Cited by 9
Visual Acuity Testing Using a Random Method Visual Acuity Application
Rhiu, S., Lee, H. J., Goo, Y. S., Cho, K.-R., & Kim, J.-H. (2015) · Telemedicine Journal and e-Health · doi:10.1089/tmj.2015.0073 · Cited by 9
Filho, J. C. J., Cyrino, E. S., Gurjão, A. L. D., Braz, I. A., Gonçalves, R., & Gobbi, S. (2010) · Revista Brasileira de Medicina do Esporte · doi:10.1590/s1517-86922010000100002 · Cited by 19
Moreno, M.-V., Ribbe, E., Rebeyrol, J., Vannicatte, A., & Krief, L. (2015) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1305-8 · Cited by 9
A nomogram to calculate the maximum dose of local anaesthetic in a paediatric dental setting
Walker, J. D., Summers, A., & Williams, D. J. (2015) · BDJ · doi:10.1038/sj.bdj.2015.297 · Cited by 9
Huber, S., Muthupillai, R., Mojibian, H. R., Cheong, B., Kouwenhoven, M., & Flamm, S. D. (2008) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2008.01.027 · Cited by 9
Mazonakis, M., Pagonidis, K., Schlosser, T. W., Hunold, P., Damilakis, J. E., Barkhausen, J., & Gourtsoyiannis, N. (2008) · European Radiology · doi:10.1007/s00330-008-0901-5 · Cited by 9
Dynamic updating in DIAS-NIDDM and DIAS causal probabilistic networks
Hovorka, R., Tudor, R. S., Southerden, D., Meeking, D. R., Andreassen, S., Hejlesen, O. K., & Cavan, D. A. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.740878 · Cited by 11
Thunberg, P., Emilsson, K., Rask, P., & Kähäri, A. (2008) · Acta Radiologica · doi:10.1080/02841850802415544 · Cited by 9
Fountoulakis, K. Ν., Siamouli, M., Magiria, S., Panagiotidis, P. T., Kantartzis, S., Terzoglou, V. A., & Oral, T. (2011) · Annals of General Psychiatry · doi:10.1186/1744-859x-10-19 · Cited by 9
Yelland, L. N., Gialamas, A., Laurence, C., Willson, K. J., Ryan, P., & Beilby, J. (2010) · Pathology · doi:10.3109/00313020903494045 · Cited by 9
Continuous blood pressure monitor with wireless interface
Dai, H., D’Angelo, L., & Lueth, T. C. (2010) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio.2010.5723299 · Cited by 9
Accuracy of medical and ambulance record restraint and crash data information for child occupants
Bilston, L. E., & Brown, J. K. (2008) · Injury Prevention · doi:10.1136/ip.2007.017616 · Cited by 9
Soardi, C. M., Clozza, E., Turco, G., Biasotto, M., Engebretson, S. P., Wang, H., & Zaffe, D. (2013) · Clinical Oral Implants Research · doi:10.1111/clr.12225 · Cited by 9
Draijer, M. J., Hondebrink, E., van Leeuwen, T. G. J. M., & Steenbergen, W. (2009) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-009-0537-x · Cited by 9
Dunlop, K. M., Ruxton, G. D., Scott, E. M., & Bailey, D. M. (2015) · Journal of Experimental Marine Biology and Ecology · doi:10.1016/j.jembe.2015.07.010 · Cited by 9
Baseline Correction in Parallel Thorough QT Studies
Zhang, J., Dang, Q., & Malík, M. (2013) · Drug Safety · doi:10.1007/s40264-013-0040-z · Cited by 9
Knutsson, L., Lind, E., Ahlgren, A., van Osch, M. J. P., Bloch, K. M., Surova, Y., Ståhlberg, F., van Westen, D., & Wirestam, R. (2014) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24621 · Cited by 9
Barbieri, C., Cecatti, J. G., Souza, C. E., Marussi, E. F., & Costa, J. V. (2008) · Reproductive Health · doi:10.1186/1742-4755-5-5 · Cited by 9
Quinn, S. D., Vedelago, J., Regan, L., & Gedroyc, W. M. W. (2013) · Journal of Therapeutic Ultrasound · doi:10.1186/2050-5736-1-20 · Cited by 9
Reliability of a Holter-based methodology for evaluation of sleep apnoea syndrome
Szyszko, A., Franceschini, C., & González‐Zuelgaray, J. (2008) · EP Europace · doi:10.1093/europace/eun285 · Cited by 9
Tartière, J., Logeart, D., Tartière-Kesri, L., & Solal, A. C. (2007) · European Journal of Echocardiography · doi:10.1016/j.euje.2007.03.036 · Cited by 9
Williams, D. A., Roush, J. R., Davies, G. J., Ellenbecker, T. S., & Rauh, M. J. (2009) · Europe PMC (PubMed Central) · Cited by 9
Comparison of peripheral and core temperatures in anaesthetized hypovolaemic sheep
Mansel, J. C., Shaw, D. J., STRACHAN, F. A., Gray, A. R., & Clutton, R. E. (2007) · Veterinary Anaesthesia and Analgesia · doi:10.1111/j.1467-2995.2007.00358.x · Cited by 9
Spirometric reference values for children and adolescents from Kazakhstan
Facchini, F., Fiori, G., Bedogni, G., Galletti, L., Ismagulov, O., Ismagulova, A., Sharmanov, T., Tsoy, I., Belcastro, M. G., Rizzoli, S., et al. (2007) · Annals of Human Biology · doi:10.1080/03014460701556346 · Cited by 9
VMO-VL reflex latency difference in osteoarthritic knees and controls
Dixon, J., Howe, T. E., Kent, J. R., & Whittaker, V. (2004) · Advances in Physiotherapy · doi:10.1080/14038190410020809 · Cited by 10
Goubard, A., Marzouk, M., Canouï‐Poitrine, F., Launay, S., Thuaut, A. L., & Legrand, P. (2011) · Journal of Clinical Pathology · doi:10.1136/jcp.2010.084285 · Cited by 9
Olsen, L. H., Kristensen, A. T., Qvortrup, K., & Pedersen, H. D. (2004) · Journal of Veterinary Diagnostic Investigation · doi:10.1177/104063870401600215 · Cited by 9
Validation of the Actical and Actiheart monitor in ambulatory children with Spina Bifida
de Groot, J. F., de Jong, A. S., Visser, T., & Takken, T. (2013) · Journal of Pediatric Rehabilitation Medicine · doi:10.3233/prm-130244 · Cited by 9
Wertheim, D. F., & Gillmore, G. K. (2014) · Journal of Microscopy · doi:10.1111/jmi.12114 · Cited by 9
Chia, M., & Lim, J. M. (2008) · Annals of the Academy of Medicine Singapore · doi:10.47102/annals-acadmedsg.v37n4p279 · Cited by 9
Neukamm, C., Try, K., Norgård, G., & Brun, H. (2013) · Congenital Heart Disease · doi:10.1111/chd.12146 · Cited by 13
Kruger, I. M., Kruger, M., Doak, C. M., & Kruger, A. (2012) · Journal of Endocrinology Metabolism and Diabetes of South Africa · doi:10.1080/22201009.2012.10872281 · Cited by 9
On the propagation analysis of electrohysterographic signals
Rabotti, C., Mischi, M., van Laar, J. O. E. H., Oei, S. G., & Bergmans, J. W. M. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4650054 · Cited by 9
Cephalometric evaluation of the changes in mandibular symphysis after 7 years of denture wearing
Karkazis, H. C., Lambadakis, J., & Tsichlakis, K. (1997) · Gerodontology · doi:10.1111/j.1741-2358.1997.00101.x · Cited by 9
Heesterman, B. L., Verbist, B. M., van der Mey, A. G. L., Bayley, J., Corssmit, E. P. M., Hes, F. J., & Jansen, J. C. (2015) · Clinical Otolaryngology · doi:10.1111/coa.12562 · Cited by 9
Estimation of daily dietary fluoride intake: 3-d food diaryv. 2-d duplicate plate
Omid, N., Maguire, A., O’Hare, W. T., & Zohoori, F. V. (2015) · British Journal Of Nutrition · doi:10.1017/s0007114515003906 · Cited by 18
Fabbian, F., Pala, M., Monesi, M., Giorgi, A. D., Menegatti, A. M., Tomasi, F., Portaluppi, F., & Manfredini, R. (2013) · PubMed · Cited by 9
Peng, S., Wang, F., Yang, T.-C., Hsu, J., Wu, Y.-C., & Peng, H. (2015) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2015.12.026 · Cited by 9
Pulmonary Artery Dilation and Right Ventricular Function in Acute Kawasaki Disease
Numano, F., Shimizu, C., Tremoulet, A. H., Dyar, D., Burns, J. C., & Printz, B. F. (2015) · Pediatric Cardiology · doi:10.1007/s00246-015-1303-5 · Cited by 9
Activity Monitors Step Count Accuracy in Community-Dwelling Older Adults
Johnson, M. J. (2015) · Gerontology and Geriatric Medicine · doi:10.1177/2333721415601303 · Cited by 11
Lee, Y. C., Fullerton, G. D., & Goins, B. (2015) · Open Journal of Medical Imaging · doi:10.4236/ojmi.2015.53016 · Cited by 9
Gunes, F., Elmacıoğlu, F., Aktaç, Ş., & Sağlam, D. (2015) · Polish Journal of Food and Nutrition Sciences · doi:10.1515/pjfns-2015-0029 · Cited by 9
Validation of the Korean coefficient for the modification of diet in renal disease study equation
Oh, Y. J., Cha, R., Lee, S., Yu, K. S., Kim, S. E., Kim, H., & Kim, Y. S. (2016) · The Korean Journal of Internal Medicine · doi:10.3904/kjim.2015.227 · Cited by 9
Su, A. T., & Hoe, V. C. W. (2008) · PubMed · Cited by 9
Validity of radiographic assessment of the knee joint space using automatic image analysis
Komatsu, D., Hasegawa, Y., Kojima, T., Seki, T., Ikeuchi, K., Takegami, Y., Amano, T., Higuchi, Y., Kasai, T., & Ishiguro, N. (2015) · Modern Rheumatology · doi:10.3109/14397595.2015.1130679 · Cited by 9
Anderle, H., & Weber, A. (2016) · Journal of Pharmaceutical Sciences · doi:10.1016/j.xphs.2016.01.009 · Cited by 9
Prediction of basal metabolic rate in patients with Prader–Willi syndrome
Lazzer, S., Grugni, G., Tringali, G., & Sartório, A. (2015) · European Journal of Clinical Nutrition · doi:10.1038/ejcn.2015.161 · Cited by 10
Albanese, M., Neofytou, M., Ouarrak, T., Schneider, S., & Schöls, W. H. (2016) · European Journal of Clinical Pharmacology · doi:10.1007/s00228-016-2046-9 · Cited by 9
Shannon, H. E., Fishel, M. L., Xie, J., Gu, D., McCarthy, B. P., Riley, A. K., Sinn, A. L., Silver, J. M., Peterman, K. M., Kelley, M. R., et al. (2014) · Pancreas · doi:10.1097/mpa.0000000000000238 · Cited by 9
Salah, A., Yang, H., Tang, L., Li, X., Liu, Q., & Zhou, S. (2014) · The Anatolian Journal of Cardiology · doi:10.5152/akd.2014.5217 · Cited by 9
Vujosevic, S., Pucci, P., Daniele, A. R., Convento, E., Pilotto, E., Parrozzani, R., Kotsafti, O., Cavarzeran, F., & Midena, E. (2014) · Retina · doi:10.1097/iae.0000000000000262 · Cited by 9
Kennedy, S. J., Ryan, L., Fraser, A., & Clegg, M. (2014) · Journal of Nutritional Science · doi:10.1017/jns.2014.58 · Cited by 9
Zhong, N., Saenger, A. K., Topazian, M. D., Gleeson, F. C., Chari, S. T., Clain, J. E., Levy, M. J., Rajan, E., & Enders, F. (2011) · Pancreas · doi:10.1097/mpa.0b013e318204e89a · Cited by 9
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.