STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 32,001–32,100 of 47,868
Zheng, W., Zhou, L., Chai, Q.-W., Xu, J., & Liu, S. (2022) · Electronics · doi:10.3390/electronics11071093 · Cited by 8
Song, Y., Zöllner, H. J., Hui, S. C. N., Hupfeld, K. E., Oeltzschner, G., Prisciandaro, J. J., & Edden, R. A. E. (2022) · Frontiers in Psychiatry · doi:10.3389/fpsyt.2022.872403 · Cited by 8
Analytical Approaches for the Segmentation of the Zebrafish Brain Vasculature
Kugler, E., Rampun, A., Chico, T., & Armitage, P. A. (2022) · Current Protocols · doi:10.1002/cpz1.443 · Cited by 9
Giannetto, C., Pietro, S. D., Pennisi, M. G., Acri, G., Piccione, G. G., & Giudice, E. (2022) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2022.103281 · Cited by 8
Two-Step Validation of a New Wireless Inertial Sensor System: Application in the Squat Motion
Blandeau, M., Guichard, R., Hubaut, R., & Leteneur, S. (2022) · Technologies · doi:10.3390/technologies10030072 · Cited by 9
Sugg, M. M., Runkle, J. D., Dow, K. M., Barnes, J., Stevens, S. E., Pearce, J. L., Bossak, B. H., & Curtis, S. (2022) · International Journal of Biometeorology · doi:10.1007/s00484-022-02309-y · Cited by 12
de Barros, D. P. M., Ribeiro, E. C. D. O., do Nascimento, J. J. C., Neto, E. J. D. S., & Araújo-Neto, S. A. (2022) · World Neurosurgery · doi:10.1016/j.wneu.2022.06.108 · Cited by 8
Großfeld, R., Pable, J., Jakop, U., Simmet, C., & Schulze, M. (2022) · Scientific Reports · doi:10.1038/s41598-022-16280-6 · Cited by 8
Bučan, A., Wiinholt, A., Dalaei, F., Gerke, O., Hansen, C. R., & Sørensen, J. A. (2022) · Scientific Reports · doi:10.1038/s41598-022-16311-2 · Cited by 8
D’Hondt, J., Waterplas, J., Chapelle, L., Clarys, P., & D’Hondt, E. (2022) · Applied Sciences · doi:10.3390/app12157686 · Cited by 12
Validating the accuracy of multispectral metal artifact suppressed diffusion‐weighted imaging
Neri, J. P., Koff, M. F., Koch, K. M., & Tan, E. T. (2022) · Medical Physics · doi:10.1002/mp.15925 · Cited by 9
The Body Adiposity Index is not applicable to the Brazilian adult population
da Costa, J. R. R., da Costa, R. F., Gonçalves, C. A. M., Borges, M. V. D. O., de Almeida‐Neto, P. F., de Assis, G. G., Cabral, B. G. D. A. T., & Dantas, P. M. S. (2022) · Frontiers in Nutrition · doi:10.3389/fnut.2022.888507 · Cited by 8
Monte Carlo-based independent dose verification of radiosurgery HyperArc plans
Calvo-Ortega, J. F., Moragues-Femenía, S., Laosa-Bello, C., Hermida‐López, M., Pozo-Massó, M., & Zamora-Pérez, A. (2022) · Physica Medica · doi:10.1016/j.ejmp.2022.08.016 · Cited by 8
Validation of high concentrated thrombin time assay for unfractionated heparin monitoring
Apipongrat, D., Police, P., Lamool, R., Butthep, P., & Chantkran, W. (2022) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.24695 · Cited by 9
Análisis microbiológico del pulpo rojo en puertos pesqueros de Campeche, México
Estrella-Gómez, N., Escalante-Réndiz, D., González-Burgos, A., Cordero, D. M. S., & Rojas-Herrera, R. A. (2016) · Salud Pública de México · doi:10.21149/spm.v58i4.8026 · Cited by 8
Marcos‐Lorenzo, D., Frett, T., Gil‐Martínez, A., Speer, M., Swanenburg, J., & Green, D. A. (2022) · BMC Sports Science Medicine and Rehabilitation · doi:10.1186/s13102-022-00575-2 · Cited by 8
Plaza, E. M., López‐Miguel, A., la Rosa, A. L., & Maldonado, M. J. (2022) · International Ophthalmology · doi:10.1007/s10792-022-02546-5 · Cited by 8
Jung, Y., Han, J. H., Choi, H. J., & Lee, J. H. (2022) · Audiology and Speech Research · doi:10.21848/asr.220077 · Cited by 8
Stride frequency derived from GPS speed fluctuations in galloping horses
Pfau, T., Bruce, O. L., Edwards, W. B., & Léguillette, R. (2022) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2022.111364 · Cited by 8
Fujii, R., Pattaro, C., Tsuboi, Y., Ishihara, Y., Melotti, R., Yamada, H., Ando, Y., Ishikawa, H., Ohashi, K., Hashimoto, S., et al. (2022) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2022.10.011 · Cited by 8
Pebley, K., Farage, G., Hare, M. E., Bursac, Z., Andres, A., Chowdhury, S. M. R., Talcott, G. W., & Krukowski, R. A. (2022) · BMC Public Health · doi:10.1186/s12889-022-14457-2 · Cited by 8
Milano, G., Colosio, A., Scaini, A., Motta, M., Raggi, A., Zanoni, F., Galli, S., & Saccomanno, M. F. (2022) · Archives of Orthopaedic and Trauma Surgery · doi:10.1007/s00402-022-04679-9 · Cited by 8
Skendi, M., Liard, R., Besacier, C., Corréas, J.-M., Moussaoui, S., Chastang, J., & Ibañez, G. E. (2022) · POCUS Journal · doi:10.24908/pocus.v7i2.15458 · Cited by 13
Brühschwein, A., Schmitz, B., Zöllner, M., Reese, S., & Meyer‐Lindenberg, A. (2022) · Frontiers in Veterinary Science · doi:10.3389/fvets.2022.1019215 · Cited by 8
Ghat: an R package for identifying adaptive polygenic traits
Mahmoud, M., Tost, M. L., Ha, N.-T., Simianer, H., & Beissinger, T. M. (2022) · G3 Genes Genomes Genetics · doi:10.1093/g3journal/jkac319 · Cited by 10
Parkhurst, J. T., Mach, T. V., Vesco, A. T., Kerns, C. E., & Lavigne, J. V. (2022) · Quality of Life Research · doi:10.1007/s11136-022-03333-6 · Cited by 8
Yang, C.-L., Simpson, L. A., & Eng, J. J. (2023) · American Journal of Occupational Therapy · doi:10.5014/ajot.2023.050020 · Cited by 8
Piroli, F., Boccellino, A., Ingallina, G., Rolando, M., Melillo, F., Ancona, F., Stella, S., Biondi, F., Palmisano, A., Esposito, A., et al. (2023) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jead015 · Cited by 8
Peinado‐Izaguerri, J., Zarzuela, E., McLaughlin, M., Small, A. C., Riva, F. T., McKeegan, D. E. F., Bain, M., Muñoz, J., Bhide, M. R., & Preston, T. (2023) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.9497 · Cited by 8
Kumar, V. S. S., & Shahraz, S. (2023) · Health Services and Outcomes Research Methodology · doi:10.1007/s10742-023-00299-x · Cited by 9
Schading‐Sassenhausen, S., Seif, M., Leutritz, T., Hupp, M., Curt, A. E. P., Weiskopf, N., & Freund, P. (2023) · NeuroImage · doi:10.1016/j.neuroimage.2023.120046 · Cited by 8
The Role of Belgian Airborne Sniffer Measurements in the MARPOL Annex VI Enforcement Chain
Roy, W. V., Merveille, J.-B., Scheldeman, K., Nieuwenhove, A. V., Roozendael, B. V., Schallier, R., & Maes, F. (2023) · Atmosphere · doi:10.3390/atmos14040623 · Cited by 8
Beggs, M. R., Ashkin, A., Larsen, B. K., & Garros, D. (2023) · Pediatric Critical Care Medicine · doi:10.1097/pcc.0000000000003266 · Cited by 9
Schmidt, W., Hoffmeister, T., Wachsmuth, N. B., & Byrnes, W. C. (2023) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2023.2204402 · Cited by 9
Energy Expenditure Estimation for Forestry Workers Moving on Flat and Inclined Ground
Okuda, M., Kawamoto, Y., Tado, H., Fujita, Y., & Inomata, Y. (2023) · Forests · doi:10.3390/f14051038 · Cited by 8
Pi, L., Zheng, Y., Shi, X., Wang, Z., & Zhou, Z. (2023) · Frontiers in Public Health · doi:10.3389/fpubh.2023.1078361 · Cited by 13
Pulse rate variability: An alternative to heart rate variability in adults with spinal cord injury
Schoffl, J., Pozzato, I., Rodrigues, D., Arora, M., & Craig, A. R. (2023) · Psychophysiology · doi:10.1111/psyp.14356 · Cited by 8
New Food Frequency Questionnaire to Estimate Vitamin K Intake in a Mediterranean Population
Pinto, E. A. M., Viegas, C., Martins, P. V., Nascimento, T., Schurgers, L. J., & Simes, D. C. (2023) · Nutrients · doi:10.3390/nu15133012 · Cited by 9
Schwärzler, A., Lettner, S., Nemec, M., Rank, C., Schedle, A., & Jonke, E. (2023) · Dental Materials · doi:10.1016/j.dental.2023.07.003 · Cited by 10
Rinderknecht, M. D., Zanon, M., Boonstra, T. A., Angelini, L., Stanev, D., Chan, G. G., Bunn, L. M., Dondelinger, F., Hosking, R., Freeman, J. A., et al. (2023) · Digital Health · doi:10.1177/20552076231205284 · Cited by 14
Pieroni, C., Grassi, A., Pantoli, M., Berretti, M., Messina, S., Giovannini, C., Lubas, G., & Diamanti, D. (2023) · Veterinary Medicine International · doi:10.1155/2023/9965095 · Cited by 8
Silva, J. C., Santos, C., Dinis-Ribeiro, M. J., & Libânio, D. (2023) · European Journal of Gastroenterology & Hepatology · doi:10.1097/meg.0000000000002671 · Cited by 8
Simonet, A., Delafontaine, A., Fourcade, P., & Yiou, É. (2024) · Sensors · doi:10.3390/s24041302 · Cited by 15
Comparison of Optic Disc Parameters Measured by RTVue-100 FDOCT Versus HRT-II
Mesiwala, N. K., Pekmezci, M., Huang, J., Porco, T. C., & Lin, S. C. (2011) · Journal of Glaucoma · doi:10.1097/ijg.0b013e3182253e58 · Cited by 8
Pinero, D. P., Camps, V. J., Ramón, M. L., Mateo, V., & Pérez-Cambrodí, R. J. (2015) · Indian Journal of Ophthalmology · doi:10.4103/0301-4738.159882 · Cited by 8
Akkurt, M. Ö., Yavuz, A., Akkurt, İ., Karakoç, G., & Sezi̇k, M. (2015) · Journal of Perinatal Medicine · doi:10.1515/jpm-2015-0147 · Cited by 8
Haibel, H., Niewerth, M., Brandt, J., Rudwaleit, M., Listing, J., Sieper, J., & Braun, J. (2004) · Zeitschrift für Rheumatologie · doi:10.1007/s00393-004-0604-5 · Cited by 8
Sensibilidade e especificidade no diagnóstico de hipertensão por diferentes métodos
Nascimento, L. R., Coelli, A. P., Cadê, N. V., Mill, J. G., & Molina, M. D. C. B. (2011) · Revista de Saúde Pública · doi:10.1590/s0034-89102011005000063 · Cited by 13
Mohan, H. K., Livieratos, L., Gallagher, S., Bailey, D. L., Chambers, J. B., & Fogelman, I. (2004) · International Journal of Clinical Practice · doi:10.1111/j.1742-1241.2004.00215.x · Cited by 8
A longitudinal study of normal fetal femur volume
Ioannou, C., Sarris, I., Napolitano, R., Ohuma, E. O., Javaid, M. K., & Papageorghiou, A. T. (2013) · Prenatal Diagnosis · doi:10.1002/pd.4203 · Cited by 8
Atrium electromechanical interval in left ventricular diastolic dysfunction
Chao, T., Wang, K., Chuang, C., Chen, S., & Yu, W. (2011) · European Journal of Clinical Investigation · doi:10.1111/j.1365-2362.2011.02564.x · Cited by 8
Mazzoni, L. N., Belli, G., Ginestroni, A., Pratesi, A., Agnoloni, S., Diciotti, S., & Mascalchi, M. (2009) · La radiologia medica · doi:10.1007/s11547-009-0408-4 · Cited by 8
Enhanced automatic lung segmentation using graph cut for Interstitial Lung Disease
Ming, J. T. C., Noor, N. M., Rijal, O. M., Kassim, R. M., & Yunus, A. (2014) · IEEE-EMBS Conference on Biomedical Engineering and Sciences · doi:10.1109/iecbes.2014.7047479 · Cited by 8
Arterial tension time reflects subclinical atherosclerosis, arterial stiffness and stroke volume
Koivistoinen, T., Kööbi, T., Moilanen, L., Jula, A., Lehtimäki, T. J., Hyttinen, J., & Kähönen, M. A. P. (2011) · Clinical Physiology and Functional Imaging · doi:10.1111/j.1475-097x.2011.01042.x · Cited by 9
Transcutaneous Renal Function Monitor: Precision During Unsteady Hemodynamics
Bauman, L. A., Watson, N. E., Scuderi, P. E., & Peters, A. M. (1998) · Journal of Clinical Monitoring and Computing · doi:10.1023/a:1009992308204 · Cited by 8
Rech, C. R., & Glaner, M. F. (2011) · Brazilian Journal of Kinanthropometry and Human Performance · doi:10.5007/1980-0037.2011v13n2p100 · Cited by 9
Scully, C. G., Gomatam, S. V., Forrest, S., & Strauss, D. G. (2015) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-015-9749-9 · Cited by 8
Brown, T., Luby, M. L., Shah, J., Giannakidis, D., & Latour, L. L. (2015) · Journal of Stroke and Cerebrovascular Diseases · doi:10.1016/j.jstrokecerebrovasdis.2015.04.012 · Cited by 8
The Effect of Sampling Time on Blood Lactate Concentration ([Bla]) in Trained Rowers
Kass, L. S., & Carpenter, R. (2009) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.4.2.218 · Cited by 9
Casciaro, M. E., Batti, S. E., Chironi, G. N., Simon, A. C., Mousseaux, É., Armentano, R. L., Alsac, J.-M., & Craiem, D. O. (2015) · Annals of Biomedical Engineering · doi:10.1007/s10439-015-1446-9 · Cited by 8
Neveu, P., Priot, A.-E., Philippe, M., Fuchs, P., & Roumes, C. (2015) · Clinical and Experimental Optometry · doi:10.1111/cxo.12311 · Cited by 10
Assessing fullness of asthma patients' aerosol inhalers.
Rickenbach, M. A., & Julious, S. A. (1994) · Europe PMC (PubMed Central) · Cited by 8
Schmidt, M., Spengler, H., Lambrecht, B., Hourfar, M. K., Seifried, E., & Tonn, T. (2009) · Transfusion · doi:10.1111/j.1537-2995.2009.02326.x · Cited by 8
Application criteria for infrared ear thermometers in pediatric surgery
Saxena, A. K., S, S. T., Heinecke, A., & Willital, G. H. (2001) · Technology and Health Care · doi:10.3233/thc-2001-9305 · Cited by 8
Granger, L., Armbrust, L. J., Rankin, D. C., Ghering, R., Bello, N. M., & Alexander, K. (2011) · Veterinary Radiology & Ultrasound · doi:10.1111/j.1740-8261.2011.01899.x · Cited by 8
Clinical Analysis of Macular Edema with New Software for SD-OCT Imaging
Azzolini, C., Sansoni, G., Donati, S., Parodi, M. B., Oum, M. A., Vinciguerra, R., Tartaglia, V., Semeraro, F., & Virgili, G. (2013) · European Journal of Ophthalmology · doi:10.5301/ejo.5000329 · Cited by 8
Respiratory function parameters in infants using inductive plethysmography
Selbie, R. D., Fletcher, M. E., Arestis, N., White, R., Duncan, A. L., Helms, P. J. B., & Duffty, P. (1997) · Medical Engineering & Physics · doi:10.1016/s1350-4533(97)00024-6 · Cited by 8
Anatomic m-mode, a pertinent tool for the daily practice of transthoracic echocardiography
Donal, E., Coisne, D., Pham, B., Ragot, S., Herpin, D., & Thomas, J. D. (2004) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2004.05.009 · Cited by 8
A shift in the epidemiology of low body mass index in Brazilian adults
Hallal, P. C., Wells, J. C. K., Bertoldi, A. D., Gazalle, F. K., da Silva, M. C., Domingues, M. R., Carret, M. L. V., Araújo, C. L., & Gigante, D. P. (2005) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1602204 · Cited by 8
Assessment of accuracy of Cockcroft-Gault and MDRD formulae in critically ill Indian patients
Todi, S. K., Majumdar, A., Kharbanda, M., & Basu, S. (2013) · Indian Journal of Critical Care Medicine · doi:10.4103/0972-5229.114820 · Cited by 8
Measuring Stress Velocity Index Using Mean Blood Pressure: Simple yet Accurate?
Aggarwal, S. A., Pettersen, M. D., Gurckzynski, J., & L’Ecuyer, T. J. (2007) · Pediatric Cardiology · doi:10.1007/s00246-007-9101-3 · Cited by 8
Waes, O. J. F. V., Jaquet, J.-B., Hop, W. C. J., Morak, M. J. M., IJzermans, J., & Koning, J. (2009) · European Journal of Trauma and Emergency Surgery · doi:10.1007/s00068-008-8121-x · Cited by 8
Allowable Total Error and Limits for Erroneous Results (ATE/LER) zones for agreement measurement
Zhou, Y., Zang, J., Wu, M., Xu, J., & He, J. (2011) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.20437 · Cited by 8
Sorafenib inhibits liver regeneration in rats
Andersen, K. J., Knudsen, A. R., Kannerup, A.-S., Sasanuma, H., Nyengaard, J. R., Hamilton-Dutoit, S. J., Ladekarl, M. B., & Mortensen, F. V. (2013) · HPB · doi:10.1111/hpb.12068 · Cited by 8
Measurement of cone dark adaptation: a comparison of four psychophysical methods
Gaffney, A. J., Binns, A. M., & Margrain, T. H. (2013) · Documenta Ophthalmologica · doi:10.1007/s10633-013-9418-6 · Cited by 8
Derksen, A., Mokkink, L. B., Rietberg, M. B., Knol, D. L., Ostelo, R., & Uitdehaag, B. M. J. (2013) · Quality of Life Research · doi:10.1007/s11136-013-0375-z · Cited by 9
Perometry limb volume measurement: protocol development and reliability
Bulley, C., Coutts, F., & Tan, C.-W. (2013) · European Journal of Physiotherapy · doi:10.3109/21679169.2013.831482 · Cited by 8
Influence of the immunoassay used in measurement of serum vitamin D levels
Pintado, S. G., & Burriel, P. L. E. (2014) · Endocrinología y Nutrición (English Edition) · doi:10.1016/j.endoen.2014.02.012 · Cited by 8
Use of a Combined SpO2/PtcCO2 Sensor in the Delivery Room
Rubortone, S. A., Carolis, M. P. D., Lacerenza, S., Bersani, I., Occhipinti, F., & Romagnoli, C. (2012) · Sensors · doi:10.3390/s120810980 · Cited by 8
Reproducibility of clinical data I: continuous outcomes
Blackman, N. J. (2004) · Pharmaceutical Statistics · doi:10.1002/pst.104 · Cited by 11
Hakulinen, M. A., Borg, H., HÄKKINEN, A. H., Parviainen, T., Kiviranta, I., & Jurvelin, J. S. (2010) · Journal of Clinical Densitometry · doi:10.1016/j.jocd.2010.07.001 · Cited by 8
Åstrand, R., Romner, B., Reinstrup, P., Friis-Hansen, L. J., & Undén, J. (2012) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2011-0639 · Cited by 8
Ramsey, R., Isenring, E. A., & Daniels, L. (2011) · The journal of nutrition health & aging · doi:10.1007/s12603-011-0085-6 · Cited by 11
Smallwood, C. D., & Mehta, N. M. (2013) · Clinical Nutrition · doi:10.1016/j.clnu.2013.03.009 · Cited by 8
Mattos, P., Segenreich, D., Dias, G. M., Nazar, B. P., Saboya, E., & Broad, M. E. (2011) · Archives of Clinical Psychiatry (São Paulo) · doi:10.1590/s0101-60832011000300002 · Cited by 11
DuBose, J. J., Inaba, K., Branco, B. C., Barmparas, G., Lam, L., Teixeira, P. G., Belzberg, H., & Δημητριάδης, Δ. (2012) · Journal of Surgical Research · doi:10.1016/j.jss.2012.04.003 · Cited by 8
Evaluating the utility of the body adiposity index in adolescent boys and girls
Wickel, E. E. (2013) · Journal of science and medicine in sport · doi:10.1016/j.jsams.2013.06.002 · Cited by 10
Cho, P., & Chan, C. C. H. (2003) · Optometry and Vision Science · doi:10.1002/j.1538-9235.2003.tb01749.x · Cited by 8
A model for left ventricular hypertrophy enabling non-invasive assessment of cardiac function
Lunde, S., Smerup, M., Hasenkam, J. M., & Sloth, E. (2009) · Scandinavian Cardiovascular Journal · doi:10.1080/14017430802647389 · Cited by 8
Alveolar bone measurement precision for phosphor-plate images
Hildebolt, C. F., Couture, R. A., Garcia, N. M., Dixon, D. A., Miley, D. D., Shannon, W. D., Mueller, C., Langenwalter, E. M., Spearie, C. A., & Civitelli, R. (2009) · Oral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology · doi:10.1016/j.tripleo.2009.05.024 · Cited by 8
Method agreement between measuring of boar sperm concentration using Makler chamber and photometer
Janko, M., Kosec, M., Pipan, M. Z., & Zrimšek, P. (2007) · Acta veterinaria · doi:10.2298/avb0706563m · Cited by 8
Single-Point Calibration for Sirolimus Quantification
Taylor, P. J., Forrest, K. K., Salm, P., & Pillans, P. I. (2001) · Therapeutic Drug Monitoring · doi:10.1097/00007691-200112000-00023 · Cited by 8
Francz, M., Égervári, K., Kardos, L., Tóth, J., Nemes, Z., Szántó, J., & Szöllősi, Z. (2009) · Journal of Clinical Pathology · doi:10.1136/jcp.2009.066852 · Cited by 8
Huckle, A., Al‐Qaisieh, B. M., & Bownes, P. J. (2011) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2011.09.022 · Cited by 8
Pan, Y., Rose, C. E., Haber, M., Ma, Y., Carrasco, J. L., Stewart, B., Keitel, W. A., KEYSERLING, H. L., Jacobson, R. M., Poland, G. A., et al. (2013) · The International Journal of Biostatistics · doi:10.1515/ijb-2012-0001 · Cited by 8
Proteomic Profiling of Rat Thyroarytenoid Muscle
Welham, N. V., Marriott, G., & Bless, D. M. (2006) · Journal of Speech Language and Hearing Research · doi:10.1044/1092-4388(2006/049 · Cited by 8
Vogt, R., Rohling, R. G., & Kästner, S. (2007) · American Journal of Veterinary Research · doi:10.2460/ajvr.68.3.265 · Cited by 8
Faria, N., Winship, P., Weiss, D. J., Coles, B. J., Schoenberg, R., Hutchinson, C., Pereira, D. I. A., & Powell, J. J. (2011) · Journal of Analytical Atomic Spectrometry · doi:10.1039/c1ja10103j · Cited by 9
Repeatability indices for the Adams D‐15 test for colour‐normal and colour‐defective adults
Hovis, J. K., Ramaswamy, S., & Anderson, M. (2004) · Clinical and Experimental Optometry · doi:10.1111/j.1444-0938.2004.tb05062.x · Cited by 8
Walker, M. J. P., Campbell, B. R., Azer, K., Tong, C., Fang, K., Cook, J. J., Forrest, M. J., Kempadoo, K., Wright, S. D., Saltzman, J. S., et al. (2008) · Atherosclerosis · doi:10.1016/j.atherosclerosis.2008.09.013 · Cited by 8
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.