STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 32,401–32,500 of 47,868
Borai, A., Livingstone, C., Shafi, S., Zarif, H., & Ferns, G. A. (2010) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365510903544585 · Cited by 9
A comparison of a new transtelephonic portable spirometer with a laboratory spirometer
Izbicki, G., Abboud, S., Jordan, P., Perruchoud, A. P., & Bolliger, C. T. (1999) · European Respiratory Journal · doi:10.1034/j.1399-3003.1999.14a35.x · Cited by 8
Total-body-water measurement with 18O-labeled water in short-bowel patients with an ileostomy
Chambrier, C., Normand, S., Écochard, R., Pachiaudi, C., Laville, M., & Boulátreau, P. (2001) · Nutrition · doi:10.1016/s0899-9007(00)00506-2 · Cited by 8
Ma, W., Chiang, L., Yen, W., Huang, L., & Tsai, T.-W. (2011) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2011.06.005 · Cited by 8
Barreto, M., Rennerová, Z., Montesano, M., Alterio, A., Trubacova, D., Ronchetti, R., & Villa, M. P. (2008) · Journal of Asthma · doi:10.1080/02770900802040035 · Cited by 8
Petrikovsky, B. M., Oleschuk, C., Lesser, M., Gelertner, N., & Gross, B. (1997) · Journal of Clinical Ultrasound · doi:10.1002/(sici)1097-0096(199709)25:7<378::aid-jcu5>3.0.co;2-7 · Cited by 81
The size of the treatment effect: do patients and proxies agree?
van der Linden, F. A. H., Kragt, J. J., Hobart, J. C., Klein, M., Thompson, A. J., van der Ploeg, H. M., Polman, C. H., & Uitdehaag, B. M. J. (2009) · BMC Neurology · doi:10.1186/1471-2377-9-12 · Cited by 8
Sunnergren, O., Broström, A., & Svanborg, E. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.05.002 · Cited by 8
Sihan, K., Botha, C. P., Post, F. H., de Winter, S., Gonzalo, N., Regar, E. S., Serruys, P. W. J. C., Hamers, R., & Bruining, N. (2011) · EuroIntervention · doi:10.4244/eijv6i9a191 · Cited by 8
Yeo, S., Ronis, D. L., Antonakos, C. L., Roberts, K., & Hayashi, R. (2005) · Journal of Nursing Measurement · doi:10.1891/106137405780954424 · Cited by 8
Schnapauff, D., Dübel, H.-P., Scholze, J., Baumann, G., Hamm, B., & Dewey, M. (2007) · European Radiology · doi:10.1007/s00330-006-0540-7 · Cited by 8
Hingorani, P., Karnad, D. R., Panicker, G. K., Deshmukh, S., Kothari, S., & Narula, D. D. (2008) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2008.02.026 · Cited by 8
The Narcotrend™ Monitor and the Electroencephalogram in Propofol-Induced Sedation
Doenicke, Α., Kugler, J., Kochs, E. F., Rau, J., Mückter, H., Hoernecke, R., Conzen, P. F., Bromber, H., & Schneider, G. H. (2007) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000281145.46541.de · Cited by 8
Chen, J., Meyers, G. D., & Bennett, M. J. (2014) · Journal of Chromatography B · doi:10.1016/j.jchromb.2014.03.029 · Cited by 8
Quantitative Ultrasound Assessment of the Facet Joint in the Lumbar Spine: A Feasibility Study
Liu, D., Huang, Y., Tian, D., & Yin, J. (2015) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2014.12.025 · Cited by 8
Liu, D., Huang, Y., Tian, D., Yin, J., & Deng, L.-J. (2015) · Journal of Ultrasound in Medicine · doi:10.7863/ultra.35.5.759 · Cited by 8
Rotter, M., Sanders, P., Jaı̈s, P., Hocini, M., Takahashi, Y., Hsu, L.-F., Sacher, F., Rostock, T., & Haı̈ssaguerre, M. (2006) · Heart · doi:10.1136/hrt.2005.064295 · Cited by 8
Rosier, S., Launey, Y., Bleichner, J. P., Laviolle, B., Jouve, A., Mallédant, Y., & Séguin, P. (2013) · Respiratory Care · doi:10.4187/respcare.02726 · Cited by 8
Oral hygiene reinforcement in the simplified periodontal treatment of 1 hour
Apatzidou, D. A., Zygogianni, P., Sakellari, D., & Konstantinidis, A. (2013) · Journal Of Clinical Periodontology · doi:10.1111/jcpe.12200 · Cited by 12
Lama, N., Boracchi, P., & Biganzoli, E. M. (2008) · Computational Statistics & Data Analysis · doi:10.1016/j.csda.2008.11.026 · Cited by 8
An efficient framework for estimation of muscle fiber orientation using ultrasonography
Ling, S., Chen, B., Zhou, Y., Yang, W.-Z., Zhao, Y.-Q., Wang, L., & Zheng, Y. (2013) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-12-98 · Cited by 8
Cling film as a barrier against CJD in Goldmann‐type applanation tonometry
Davies, L. N., Bartlett, H. E., & Dunne, M. C. M. (2003) · Ophthalmic and Physiological Optics · doi:10.1046/j.1475-1313.2003.00161.x · Cited by 9
Comparability of Eight Immunoassay Procedures for the Determination of CA 15-3 and Related Markers
Stern, P., Bartos, V., Vávrová, J., Springer, D., Pechová, M., Uhrová, J., Friedecky, B., Šprongl, L., Zima, T., & Palička, V. (2003) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2003.168 · Cited by 8
Tests of spinal mobility and muscle strength in the young: Reliability and normative values
Oksanen, A., & Salminen, J. J. (1996) · Physiotherapy Theory and Practice · doi:10.3109/09593989609036431 · Cited by 8
Comparison of clinical data based on limits of agreement
Grilo, L. M., & Grilo, H. L. (2012) · Biometrical Letters · doi:10.2478/bile-2013-0003 · Cited by 8
Reliability of indices of neuromuscular leg performance in end-stage renal failure
Gleeson, N., Naish, P., Wilcock, J., & Mercer, T. H. (2002) · Journal of Rehabilitation Medicine · doi:10.1080/165019702760390365 · Cited by 8
Kandarakis, A. S., Soumplis, V., Pitsas, C., Kandarakis, S., Halikias, J., & Karagiannis, D. A. (2010) · Canadian Journal of Ophthalmology · doi:10.3129/i10-035 · Cited by 8
Suominen, P. K., Stayer, S. A., Wang, W., & Chang, A. C. (2007) · ASAIO Journal · doi:10.1097/mat.0b013e3181569bf3 · Cited by 8
Yamamoto, K., Kodama, K., Masuyama, T., Hirayama, A., Nanto, S., Mishima, M., Kitabatake, A., & Kamada, T. (1992) · International Journal of Cardiology · doi:10.1016/0167-5273(92)90150-2 · Cited by 9
The Work Rate Corresponding to Ventilatory Threshold During Steady-State and Ramp Exercise
Faude, O., Meyer, T., & Kindermann, W. (2006) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.1.3.222 · Cited by 8
Reliability and Validity of the VmaxST Portable Metabolic Analyzer
Perkins, C. D., Pivarnik, J., & Green, M. R. (2004) · Journal of Physical Activity and Health · doi:10.1123/jpah.1.4.413 · Cited by 12
Influence of age, site, and degenerative state on the speed of sound in equine articular cartilage
Brommer, H., Laasanen, M. S., Brama, P. A. J., van Weeren, P. R., Barneveld, A., Helminen, H. J., & Jurvelin, J. S. (2005) · American Journal of Veterinary Research · doi:10.2460/ajvr.2005.66.1175 · Cited by 8
Lee, E.-J., Kim, D.-K., Yoo, S., Kim, K., & Lee, S. (2010) · Korean Journal of Family Medicine · doi:10.4082/kjfm.2010.31.3.190 · Cited by 13
Wilson, S., O'Brien, C., Harris, M., & Masters, I. B. (1998) · European Respiratory Journal · doi:10.1183/09031936.98.12051186 · Cited by 8
Virga, G., Milia, V. L., Russo, R., Bonfante, L., Cara, M., & Nordio, M. (2009) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfp391 · Cited by 8
Koh, K. H., & Yu, C. W. (2016) · Journal of Neonatal Nursing · doi:10.1016/j.jnn.2016.01.003 · Cited by 8
Comparability of Computer-Supported Concurrent Voice Analysis
Hanschmann, H., Gärtner, S., & Berger, R. (2015) · Folia Phoniatrica et Logopaedica · doi:10.1159/000381094 · Cited by 8
Hands, B. P., & McIntyre, F. (2015) · UiTM Institutional Repositories (Universiti Teknologi MARA) · Cited by 8
Validation of an enzyme-linked immunosorbent assay for measurement of feline haptoglobin
Stiller, J., Jasensky, A., Hennies, M., Einspanier, R., & Kohn, B. (2016) · Journal of Veterinary Diagnostic Investigation · doi:10.1177/1040638716634397 · Cited by 10
Berghmans, D. D. P., Lenssen, A. F., Bastiaenen, C. H. G., Ilhan, M., Uszko‐Lencer, N. H. M. K., & Roox, G. M. (2012) · European Journal of Preventive Cardiology · doi:10.1177/2047487312437038 · Cited by 10
Fischer, M.-O., Rebet, O., Guinot, P., Lemétayer, C., Saplacan, V., Gérard, J., Fellahi, J.-L., Hanouz, J., & Lorne, E. (2016) · Anaesthesia Critical Care & Pain Medicine · doi:10.1016/j.accpm.2015.12.010 · Cited by 8
Tree-Encoded Conditional Random Fields for Image Synthesis
Jog, A., Carass, A., Pham, D. L., & Prince, J. L. (2015) · Lecture notes in computer science · doi:10.1007/978-3-319-19992-4_58 · Cited by 8
Evaluation of physiological strain in hot work areas using thermal imagery
Holm, C. A., Pahler, L. F., Thiese, M. S., & Handy, R. G. (2016) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2016.07.013 · Cited by 10
The Accuracy of Anthropometric Equations to Assess Body Fat in Adults with Down Syndrome
Rossato, M. F., Dellagrana, R. A., da Costa, R. M., Bezerra, E. D. S., dos Santos, J. O. L., & Rech, C. R. (2016) · Journal of Applied Research in Intellectual Disabilities · doi:10.1111/jar.12290 · Cited by 9
Caballeros, M., Leal, P. B., González, Ó. F., Greiser, A., del Barrio, L. G., Pueyo, J. C., & Bastarrika, G. (2016) · Acta Radiologica · doi:10.1177/0284185116674501 · Cited by 8
Short-Term Test-Retest Reliability of Respiratory Sinus Arrhythmia (RSA) in Young Adults
Borges, C., Mathewson, K. J., & Schmidt, L. A. (2017) · Journal of Psychophysiology · doi:10.1027/0269-8803/a000187 · Cited by 10
Jones, J. H., Singh, N. S., Nidecker, A. E., Li, C., & Fishman, S. M. (2017) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000001839 · Cited by 9
de Sousa, T. M., Maioli, T. U., dos Santos, A. L. S., & dos Santos, L. C. (2017) · Nutrition · doi:10.1016/j.nut.2017.02.009 · Cited by 8
Campo, A., Dudzik, G., Apostolakis, J., Wąż, A., Nauleau, P., Abramski, K. M., Dirckx, J., & Konofagou, E. E. (2017) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2017.05.013 · Cited by 8
Salas, J. D. Z., & Murray, A. L. (2017) · American Journal of Human Biology · doi:10.1002/ajhb.23028 · Cited by 12
Therapeutic drug monitoring of caffeine in preterm infants: Could saliva be an alternative to serum?
Chaabane, A., Chioukh, F. Z., Chadli, Z., Fredj, N. B., Ameur, K. B., Hmida, H. B., Boughattas, N. A., Monastiri, K., & Aouam, K. (2017) · Therapies · doi:10.1016/j.therap.2017.06.004 · Cited by 8
Rodrigues, A. M. D. S., Costa, A. B. P., Campos, D. L., Silva, M. P. S., Cândido, A. L., dos Santos, L. C., & Ferreira, A. V. M. (2017) · Journal of Human Nutrition and Dietetics · doi:10.1111/jhn.12498 · Cited by 10
Solid Phase Immunoassay for the Detection of Anticardiolipin Antibodies
Willis, R., Papalardo, E., & Harris, E. N. (2017) · Methods in molecular biology · doi:10.1007/978-1-4939-7196-1_16 · Cited by 8
Gagnon, D. H., Cunha, J. D., Boyer-Delestre, M., Bosquet, L., & Duclos, C. (2017) · Gait & Posture · doi:10.1016/j.gaitpost.2017.08.027 · Cited by 8
The PerPot Simulated Anaerobic Threshold - A Comparison to Typical Lactate-based Thresholds
Endler, S., Hoffmann, S., Sterzing, B., Simon, P. D., & Pfeiffer, M. (2017) · International journal of human movement and sports sciences · doi:10.13189/saj.2017.050102 · Cited by 9
Karasu, A., Šrámek, A., Rosendaal, F. R., van der Geest, R. J., & Vlieg, A. V. H. (2017) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.13880 · Cited by 8
Rosenblatt, A. J., Scrivani, P. V., Boisclair, Y. R., Reeves, A. P., Ramos-Nieves, J. M., Xie, Y., & Erb, H. N. (2017) · The Veterinary Journal · doi:10.1016/j.tvjl.2017.10.012 · Cited by 10
Volz, T., Schwaiger, R., Wang, J., & Weygand, S. M. (2017) · IOP Conference Series Materials Science and Engineering · doi:10.1088/1757-899x/257/1/012013 · Cited by 8
Zambrano, M. B., Félix, T. M., & de Mello, E. D. (2017) · Annals of Nutrition and Metabolism · doi:10.1159/000481918 · Cited by 8
Ramos, R. D. A., Guimarães, F. S., Dionyssiotis, Y., Tsekoura, D., Papathanasiou, J. V., & Ferreira, A. D. S. (2018) · Journal of Bodywork and Movement Therapies · doi:10.1016/j.jbmt.2018.01.010 · Cited by 9
Stubberud, A., Omland, P. M., Tronvik, E., Olsen, A., Sand, T., & Linde, M. (2018) · JMIR Biomedical Engineering · doi:10.2196/biomedeng.9062 · Cited by 8
Smith, S. K., & Astell, A. J. (2018) · Technologies · doi:10.3390/technologies6010033 · Cited by 11
Langenfeld, A., Bastiaenen, C. H. G., Sieben, J. M., & Swanenburg, J. (2018) · Musculoskeletal Science and Practice · doi:10.1016/j.msksp.2018.04.004 · Cited by 9
Validation of a Cross-cultural Adaptation of the Hair Specific Skindex-29 Scale to Spanish
Guerra‐Tapia, A., Buendía‐Eisman, A., & Ferrando, J. (2018) · Actas Dermo-Sifiliográficas · doi:10.1016/j.adengl.2018.04.013 · Cited by 8
Mahajan, P. B., & Mukherjee, S. (2018) · Journal of Drug Assessment · doi:10.1080/21556660.2018.1487446 · Cited by 11
'Boden Food Plate': Novel Interactive Web-based Method for the Assessment of Dietary Intake
Meroni, A., Jualim, N., & Fuller, N. R. (2018) · Journal of Visualized Experiments · doi:10.3791/57923 · Cited by 8
Roach, L. A., Russell, K. G., Lambert, K., Holt, J. L., & Meyer, B. J. (2018) · Nutrition & Dietetics · doi:10.1111/1747-0080.12483 · Cited by 8
Magodoro, I. M., Albano, A. J., Muthalaly, R. G., Koplan, B. A., North, C. M., Vořechovská, D., Downey, J., Kraemer, J. D., Vaglio, M., Badilini, F., et al. (2019) · Global Heart · doi:10.1016/j.gheart.2018.11.002 · Cited by 10
Barrera, C. A., Khrichenko, D., Serai, S. D., Hartung, H. D., Biko, D. M., & Otero, H. J. (2019) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26735 · Cited by 8
New life for an old idea: Assessing tonic heat pain by means of participant controlled temperature
Jutzeler, C. R., Sirucek, L., Scheuren, P. S., Tong, B., Anenberg, E., Ortiz, O., Rösner, J., Hubli, M., & Kramer, J. L. K. (2019) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.04.003 · Cited by 9
Alberton, C. L., Andrade, L. S., Pinheiro, R. M., & Pinto, S. S. (2019) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000003161 · Cited by 9
Abuna, F., Kinuthia, J., Lagat, H., Mugwanya, K. K., Dettinger, J. C., Begnel, E. R., Sila, J., Baeten, J. M., John-Stewart, G. C., & Pintye, J. C. (2019) · JAIDS Journal of Acquired Immune Deficiency Syndromes · doi:10.1097/qai.0000000000002109 · Cited by 8
McLean, R. M., Petersen, K. S., Arcand, J., Malta, D., Rae, S., Thout, S. R., Trieu, K., Johnson, C., & Campbell, N. R. C. (2019) · Journal of Clinical Hypertension · doi:10.1111/jch.13611 · Cited by 9
Long‐Term Care Quality‐of‐Life Scale utility in community home care
McDonald, T., & Russell, F. (2019) · Nursing and Health Sciences · doi:10.1111/nhs.12628 · Cited by 9
Veneroni, C., Dahl, M. J., Lavizzari, A., Dawson, E., Rebentisch, A., Studstill, S., Bowen, S., Albertine, K. H., & Dellacà, R. L. (2019) · Physiological Measurement · doi:10.1088/1361-6579/ab3493 · Cited by 8
Segundo, E. S., & Skarnitzl, R. (2019) · Journal of Voice · doi:10.1016/j.jvoice.2019.10.007 · Cited by 10
Kuerten, D., Attar, M. H. Z., Plange, N., Walter, P., & Fuest, M. (2019) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-019-04536-3 · Cited by 8
Sex Differences in Recovery From Sprint Interval Exercise
Forsyth, J. J., & Burt, D. (2019) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000003460 · Cited by 10
Huang, T.-S., Chen, W.-J., Du, W.-Y., & Lin, J. (2020) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2020.01.069 · Cited by 8
Stokes, E. (2011) · Elsevier eBooks · doi:10.1016/b978-0-443-06915-4.00004-8 · Cited by 8
Deans, S., Kirk, A. F., McGarry, A., & Rowe, D. A. (2020) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2019-0045 · Cited by 8
A Non-contact Spirometer with Time-of-Flight Sensor for Assessment of Pulmonary Function
Sakamoto, H., Takamoto, H., Matsui, T., Kirimoto, T., & Sun, G.-H. (2020) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/embc44109.2020.9176606 · Cited by 8
Romanowski, K. L., Fradkin, A. J., Dixon, C. B., & Andreacci, J. L. (2015) · Journal of Sports Science · doi:10.17265/2332-7839/2015.04.003 · Cited by 8
Nentwich, M. M., & ULBIG, M. W. (2010) · Der Diabetologe · doi:10.1007/s11428-010-0605-8 · Cited by 17
Saito, S., Nakajima, K., Edenbrandt, L., Enqvist, O., Ulén, J., & Kinuya, S. (2021) · EJNMMI Research · doi:10.1186/s13550-021-00847-x · Cited by 9
Experimental Bone Biopsies Using Two Bone Biopsy Needles
Park, E., Hong, S. H., Kim, K. G., Choi, J., Shin, C. S., & Kang, H. S. (2009) · Academic Radiology · doi:10.1016/j.acra.2008.09.006 · Cited by 8
Alburquerque‐Sendín, F., Martín‐Vallejo, J., García-Talavera, P., Gómez, E. M. M., & del Rey, M. S. (2010) · European Journal of Anatomy · Cited by 10
Campos, J. G. S., Gómez, S. C., Guerra, J. F., Armengol, M. A. S., Gil, F. C., & Gómez, J. C. (1996) · Archivos de Bronconeumología · doi:10.1016/s0300-2896(15)30739-0 · Cited by 8
Karakitsos, D., Patrianakos, A. P., Paraskevopoulos, A. P., Parthenakis, F., Tzenakis, N., Fourtounas, C., Daphnis, E. K., & Vardas, P. E. (2006) · The International Journal of Artificial Organs · doi:10.1177/039139880602900604 · Cited by 8
Baba, R., Tsuyuki, K., Yano, H., Ninomiya, K., & Ebine, K. (2010) · PubMed Central · doi:10.18999/nagjms.72.1-2.83 · Cited by 8
High Fidelity Correction of Pressure Signals From Fluid-Filled Systems by Harmonic Analysis
Wellnhofer, E., Combé, V., Oswald, H., & Fleck, E. (1999) · Journal of Clinical Monitoring and Computing · doi:10.1023/a:1009947819352 · Cited by 8
Knaack, L., Blum, H.-C., Hohenhorst, W., Ryba, J., Guilleminault, C., & Stoohs, R. A. (2005) · Somnologie - Schlafforschung und Schlafmedizin · doi:10.1111/j.1439-054x.2005.00059.x · Cited by 8
Bendjelid, K., Schütz, N., Suter, P. M., & Romand, J. A. (2004) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03018404 · Cited by 8
Determination of Total Plasma Homocysteine: Comparison of a New Enzyme Immunoassay and a HPLC Method
Mazzola, G., D’Angelo, A., Paroni, R. C., & Fermo, I. (2000) · Thrombosis and Haemostasis · doi:10.1055/s-0037-1613955 · Cited by 8
Evaluating test methods by estimating total error
Chinchilli, V. M., & Miller, W. G. (1994) · Clinical Chemistry · doi:10.1093/clinchem/40.3.464 · Cited by 8
R wave duration as a measure of body position changes during sleep
Shinar, Z., Baharav, A., & AKSELROD, S. (2003) · Computers in cardiology · doi:10.1109/cic.1999.825903 · Cited by 8
Measuring bone mass accumulation
Heaney, R. P. (2004) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/79.2.341 · Cited by 8
Prior Knowledge of Obstetric Gestational Age and Possible Bias of Ballard Score
Smith, L. N., Dayal, V., & Monga, M. (1999) · Obstetrics and Gynecology · doi:10.1016/s0029-7844(98)00530-4 · Cited by 8
Nuclear Morphometry in Differential Diagnosis of Renal Oncocytoma and Renal Cell Carcinoma
Castren, J. P., Kuopio, T., Nurmi, M., & Collan, Y. U. (1995) · The Journal of Urology · doi:10.1016/s0022-5347(01)66843-5 · Cited by 8
Reproducibility of Blood Pressure Response to Hydrochlorothiazide
Finkielman, J. D., Schwartz, G. L., Chapman, A. B., Boerwinkle, E., & Turner, S. T. (2002) · Journal of Clinical Hypertension · doi:10.1111/j.1524-6175.2002.00965.x · Cited by 9
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.