STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 32,301–32,400 of 47,868
Matov, J., Mensah, F. K., Cook, F., & Reilly, S. (2018) · International Journal of Language & Communication Disorders · doi:10.1111/1460-6984.12378 · Cited by 11
Egekvist, A. G., Forman, A., Riiskjær, M., Kesmodel, U. S., Mathiasen, M., & Seyer‐Hansen, M. (2018) · Acta Obstetricia Et Gynecologica Scandinavica · doi:10.1111/aogs.13343 · Cited by 9
A comparison of manual counting of rabbit reticulocytes with ADVIA 2120i analyzer counting
Kaufhold, A. E., Hirschberger, J., Reese, S., Foerster, G., & Hein, J. (2018) · Journal of Veterinary Diagnostic Investigation · doi:10.1177/1040638717750428 · Cited by 8
Ramos‐Jiménez, A., Hernández‐Torres, R. P., Villalobos‐Molina, R., & Urquídez-Romero, R. (2018) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2018.04.006 · Cited by 8
Smith, A. D., Duffy, C. J., & Goodman, A. D. (2018) · Multiple Sclerosis Journal - Experimental Translational and Clinical · doi:10.1177/2055217318767458 · Cited by 8
Two-Point Method for Measuring the Temporal Modulation Transfer Function
Morimoto, T., Irino, T., Harada, K., Nakaichi, T., Okamoto, Y., Kanno, A., Kanzaki, S., & Ogawa, K. (2018) · Ear and Hearing · doi:10.1097/aud.0000000000000590 · Cited by 8
Teefy, P. J., Bagur, R., Phillips, C., Karimi-Shahri, K., Teefy, J., Sule, R., Dempsey, A. A., & Norozi, K. (2018) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2018.04.040 · Cited by 10
Venter, F., Chersich, M., Majam, M., Akpomiemie, G., Arulappan, N., Moorhouse, M. A., Mashabane, N., & Glencross, D. K. (2018) · International Journal of STD & AIDS · doi:10.1177/0956462418771768 · Cited by 8
Jędrusik, P., Symonides, B., & Gaciong, Z. A. (2018) · Journal of the American Society of Hypertension · doi:10.1016/j.jash.2018.03.010 · Cited by 8
Retinal microcirculation and leukocyte telomere length in the general population
Martens, D. S., Wei, F., Cox, B., Plusquin, M., Thijs, L., Winckelmans, E., Zhang, Z., Nawrot, T. S., & Staessen, J. A. (2018) · Scientific Reports · doi:10.1038/s41598-018-25165-6 · Cited by 11
Kallen, M. A., Cook, K. F., Amtmann, D., Dworak, E. M., & Gershon, R. C. (2018) · Quality of Life Research · doi:10.1007/s11136-018-1870-z · Cited by 10
McLean, R. M., Williams, S., Morenga, L. T., & Mann, J. I. (2018) · European Journal of Clinical Nutrition · doi:10.1038/s41430-018-0176-0 · Cited by 10
Mader, M. M.-D., Leidorf, A., Hecker, A., Heimann, A., Mayr, P., Kempski, O. S., Alessandri, B., & Wöbker, G. (2018) · Neurocritical Care · doi:10.1007/s12028-018-0541-9 · Cited by 8
Appiah-Dwomoh, E. K., Müller, S., & Mayer, F. (2018) · Rehabilitation Research and Practice · doi:10.1155/2018/8438350 · Cited by 8
Step oximetry test: a validation study
Fox, B. D., Sheffy, N., Vainshelboim, B., Fuks, L., & Kramer, M. R. (2018) · BMJ Open Respiratory Research · doi:10.1136/bmjresp-2018-000320 · Cited by 8
Analysing blood from intraosseous access: a systematic review
Jousi, M., Laukkanen‐Nevala, P., & Nurmi, J. O. (2018) · European Journal of Emergency Medicine · doi:10.1097/mej.0000000000000569 · Cited by 8
Wadduwage, D. N., Kay, J. E., Singh, V. R., Kiraly, O., Sukup-Jackson, M. R., Rajapakse, J. C., Engelward, B. P., & So, P. T. C. (2018) · Scientific Reports · doi:10.1038/s41598-018-30557-9 · Cited by 8
Chemtob, R. A., & Møller‐Sørensen, H. (2018) · Scandinavian Journal of Trauma Resuscitation and Emergency Medicine · doi:10.1186/s13049-018-0537-7 · Cited by 8
Reliability of an ice hockey-specific complex test
Schwesig, R., Lauenroth, A., Schulze, S. D., Laudner, K. G., Bartels, T., Delank, K. S., Reinhardt, L., Kurz, E., & Hermassi, S. (2018) · Sportverletzung · Sportschaden · doi:10.1055/a-0648-8874 · Cited by 8
Reliability of Submaximal Yo-Yo Tests in 9- to 16-Year-Old Untrained Schoolchildren
Póvoas, S. C. A., Krustrup, P., Castagna, C., da Silva, P. M. R., Coelho-e-Silva, M. J., Pereira, R., & Larsen, M. N. (2018) · Pediatric Exercise Science · doi:10.1123/pes.2017-0139 · Cited by 11
Tolusso, D. V., Dobbs, W. C., & Esco, M. R. (2018) · International journal of exercise science · doi:10.70252/gvcv6208 · Cited by 8
Vainshelboim, B., MYERS, J. N., de Oliveira, J. J. F., Izhakian, S., Unterman, A., & Kramer, M. R. (2018) · Journal of Cardiopulmonary Rehabilitation and Prevention · doi:10.1097/hcr.0000000000000362 · Cited by 8
Estève, É., Maccari, F., Delavierre, D., Vicariot, C., Charles, B., Marty, M., & Lespessailles, É. (2018) · Medicine · doi:10.1097/md.0000000000012807 · Cited by 9
Knešaurek, K., Tuli, A., Pasik, S. D., Heiba, S., & Kostakoğlu, L. (2018) · European Journal of Radiology · doi:10.1016/j.ejrad.2018.10.015 · Cited by 10
Comparison of Anorectal Manometry Testing in Left Lateral and Lithotomy Positions
Halani, P. K., Pahwa, A. K., Koelper, N., Arya, L. A., Sammel, M. D., & Andy, U. U. (2018) · Urogynecology · doi:10.1097/spv.0000000000000620 · Cited by 8
Gupta, L. C., Waisbourd, M., Sanvicente, C., Hsieh, M., Wizov, S. S., Spaeth, E., Richman, J., & Spaeth, G. L. (2018) · Japanese Journal of Ophthalmology · doi:10.1007/s10384-018-0640-3 · Cited by 8
McLester, C. N., Nickerson, B. S., Kliszczewicz, B. M., Hicks, C. S., Williamson, C. M., Bechke, E. E., & McLester, J. R. (2018) · PLoS ONE · doi:10.1371/journal.pone.0206866 · Cited by 8
Ruddick-Collins, L. C., Byrne, N. M., & King, N. A. (2018) · Physiology & Behavior · doi:10.1016/j.physbeh.2018.11.015 · Cited by 9
Rauh, S. P., Heymans, M. W., van der Maaden, T., Mehr, D. R., Kruse, R. L., de Vet, H. C. W., & van der Steen, J. T. (2018) · The Journals of Gerontology Series A · doi:10.1093/gerona/gly260 · Cited by 9
Reproducibility of Blood Lactate Concentration Rate under Isokinetic Force Loads
Nitzsche, N., Baumgärtel, L., Maiwald, C., & Schulz, H. (2018) · Sports · doi:10.3390/sports6040150 · Cited by 10
Protein measurements in venous plasma, earlobe capillary plasma and in plasma stored on filter paper
Siart, B., de Oliveira, F. M. S., Shen, Q., Björkesten, J., Pekar, T., Steinborn, R., Nimmerichter, A., Kamali‐Moghaddam, M., & Wallner, B. (2018) · Analytical Biochemistry · doi:10.1016/j.ab.2018.11.016 · Cited by 8
Technical challenges in generalizing calibration techniques for breast density measurements
Fowler, E. E. E., Smallwood, A., Khan, N., Kilpatrick, K., Sellers, T. A., & Heine, J. (2018) · Medical Physics · doi:10.1002/mp.13325 · Cited by 8
Idema, D. L., Wang, Y., Biehl, M. L., Horvatovich, P. L., & Hak, E. (2018) · PLoS ONE · doi:10.1371/journal.pone.0208389 · Cited by 10
Vaganée, D., de Borne, S. V., Fransén, E., Voorham, J. C., der Zalm, P. V., & Wachter, S. D. (2019) · Neurourology and Urodynamics · doi:10.1002/nau.23925 · Cited by 8
Manthong, N., Wilairat, P., Nacapricha, D., & Chaneam, S. (2019) · Analytical Sciences · doi:10.2116/analsci.18p512 · Cited by 9
Sivieri, E. M., Wolfson, M. R., & Abbasi, S. (2019) · Journal of Neonatal-Perinatal Medicine · doi:10.3233/npm-1869 · Cited by 8
Wearable Wireless Body Area Nodes for Remote Physiological Signal Monitoring System
Srinivasa, M. G., & Pandian, P. S. (2019) · Journal of Biomedical Science and Engineering · doi:10.4236/jbise.2019.122011 · Cited by 8
A Formula for Estimating the Appropriate Tube Depth for Intubation
Yao, K., Goto, K., Nishimura, A., Shimazu, R., Tachikawa, S., & Iijima, T. (2019) · Anesthesia Progress · doi:10.2344/anpr-65-04-04 · Cited by 8
TMIS : a new image‐based software application for the measurement of tear meniscus height
Yang, J., Zhu, X., Liu, Y., Jiang, X., Fu, J., Ren, X., Li, K., Qiu, W., Li, X., & Yao, J. P. (2019) · Acta Ophthalmologica · doi:10.1111/aos.14107 · Cited by 8
Vaidya, G. N., Salgado, B. C., Badar, F., John, A. G., & Stoddard, M. F. (2019) · Echocardiography · doi:10.1111/echo.14362 · Cited by 10
Zhang, C., Colquitt, G., Miller, F., Shen, Y., & Modlesky, C. M. (2019) · Clinical Nutrition · doi:10.1016/j.clnu.2019.06.020 · Cited by 9
Otey, J., Torres, M. J. A., Contero, M., & Camba, J. D. (2019) · Universal Access in the Information Society · doi:10.1007/s10209-019-00686-7 · Cited by 8
Tsakiridis, I. G., Dagklis, T., Mamopoulos, A. M., Gerede, A., & Athanasiadis, A. P. (2019) · Journal of Perinatal Medicine · doi:10.1515/jpm-2019-0139 · Cited by 8
van Velthoven, M. H., Adjei, F., Vavoulis, D. V., Wells, G., Brindley, D. A., & Kardos, A. (2019) · BMJ Open · doi:10.1136/bmjopen-2018-028219 · Cited by 8
Tang, D., Mitchell, P. L. R., Liew, G., Burlutsky, G., Flood, V. M., & Gopinath, B. (2019) · Nutrients · doi:10.3390/nu11123031 · Cited by 9
Pagani, C. H. F., Funken, J., Heinrich, K., Ellermann, A., Schmidt‐Wiethoff, R., & Potthast, W. (2019) · The Knee · doi:10.1016/j.knee.2019.08.003 · Cited by 8
Vítečková, S., Krupička, R., Dušek, P., Čejka, V., Kutílek, P., Novák, J. M., Szabo, Z., & Růžička, E. (2019) · Journal of Applied Biomedicine · doi:10.1016/j.bbe.2019.12.001 · Cited by 10
Zakeri, V., Tavakolian, K., Blaber, A. P., Bauer, E. P., Dehkordi, P., & Khosrow-Khavar, F. (2020) · Physiological Measurement · doi:10.1088/1361-6579/ab6f53 · Cited by 9
Olatunji, O. P., Olawoye, O. O., & Ajayi, B. (2020) · Journal of Glaucoma · doi:10.1097/ijg.0000000000001493 · Cited by 9
Assessment of White Matter Integrity after Pediatric Traumatic Brain Injury
Wright, K. L., Hopkins, R. O., Robertson, F. E., Bigler, E. D., Taylor, H. G., Rubin, K. H., Vannatta, K. A., Stancin, T., & Yeates, K. O. (2020) · Journal of Neurotrauma · doi:10.1089/neu.2019.6691 · Cited by 9
Riojas, A. E., Valenzuela, J. R., McFarlin, B. K., Vingren, J. L., & Hill, D. W. (2020) · International journal of exercise science · doi:10.70252/uvur7625 · Cited by 8
Ebbers, S. C., Kunnen, B., van Nierop, B. J., Bemelmans, J. L. M. M., Krijger, G. C., Lam, M. G. E. H., & Braat, A. J. A. T. (2020) · CardioVascular and Interventional Radiology · doi:10.1007/s00270-020-02504-7 · Cited by 8
Blaise, S., Constans, J., Pellegrini, L., Senet, P., Lazareth, I., Cracowski, J., & Carpentier, P. (2020) · Microvascular Research · doi:10.1016/j.mvr.2020.104029 · Cited by 8
Arigliani, M., Zheng, S. L., Ruiz, G., Chakravorty, S., Bossley, C. J., Rees, D. C., & Gupta, A. K. (2020) · BMJ Paediatrics Open · doi:10.1136/bmjpo-2020-000690 · Cited by 8
Mapping the Contrast Sensitivity of the Visual Field With Bayesian Adaptive qVFM
Xu, P., Lesmes, L. A., Yu, D., & Lu, Z. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00665 · Cited by 11
Zhang, W., Li, J., Zhao, L., Zhang, J., She, H., Meng, Y., Peng, Y., Shang, K., Zhang, Y., Gu, X., et al. (2020) · Journal of Hypertension · doi:10.1097/hjh.0000000000002509 · Cited by 8
Abad, S. K. G., Akhbari, B., Salavati, M., Saeedi, A., Seydi, M., & Shakoorianfard, M. A. (2020) · Journal of Family Medicine and Primary Care · doi:10.4103/jfmpc.jfmpc_194_20 · Cited by 8
Development and Validation of the Persian Version of the Mnread Acuity Chart
Elham, R., & Jafarzadepur, E. (2020) · Journal of Current Ophthalmology · doi:10.4103/joco.joco_80_20 · Cited by 8
Chandler, A. J., Cintineo, H. P., SANDERS, D. J., McFadden, B. A., Arent, M. A., Monaco, R., & Arent, S. M. (2020) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000002489 · Cited by 8
Comparison of Omegawave Device and an Ambulatory ECG for RR Interval Measurement at rest
Orellana, J. N., Ruso-Álvarez, J. F., & Rojo‐Álvarez, J. L. (2020) · International Journal of Sports Medicine · doi:10.1055/a-1157-9220 · Cited by 9
Athavale, O. N., Paskaranandavadivel, N., Angeli, T. R., Avci, R., & Cheng, L. K. (2020) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc44109.2020.9175843 · Cited by 9
Daugirdas, J. T. (2020) · Journal of Renal Nutrition · doi:10.1053/j.jrn.2020.03.003 · Cited by 8
Inadequate energy and protein intake in geriatric outpatients with mobility problems
Yeung, S. S. Y., Trappenburg, M. C., Meskers, C. G. M., Maier, A. B., & Reijnierse, E. M. (2020) · Nutrition Research · doi:10.1016/j.nutres.2020.09.007 · Cited by 8
Zuo, Y., López, J. E., Smith, T. W., Foster, C. C., Carson, R. E., Badawi, R. D., & Wang, G. (2021) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ac15a6 · Cited by 8
Construct Validity and Reliability of the Japanese Version of the Lumbar Stiffness Disability Index
Furuya, H., Ito, T., Hirohata, K., Mitomo, S., Yamasaki, K., Igarashi, H., Omori, K., Hoshino, M., & Hart, R. A. (2020) · Spine · doi:10.1097/brs.0000000000003772 · Cited by 8
Quinn, K., Cox, A. J., Roberts, L. A., Briskey, D. R., & MINAHAN, C. L. (2020) · Journal of Sports Sciences · doi:10.1080/02640414.2020.1840755 · Cited by 11
Gallicchio, R., Scapicchio, D., Nardelli, A., Pellegrino, T., Prisco, M. R., Mainenti, P. P., Sirignano, C., Pedicini, P., & Storto, G. (2020) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2020.3042118 · Cited by 35
Johnston, H. E., de Crom, T. O. E., Hargrave, C., Adhyaru, P., Woodward, A. J., Pang, S., Ali, A., Coombes, J. S., Keating, S. E., McLean, K., et al. (2020) · Clinical Transplantation · doi:10.1111/ctr.14185 · Cited by 8
Rajagopalan, K., Alexander, M., Naik, S., Patil, N. U., Mehta, S., Leu, C., Bhosale, R. A., Mathad, J. S., Caulfield, L. E., Gupta, A., et al. (2020) · British Journal Of Nutrition · doi:10.1017/s0007114520005188 · Cited by 8
D’Cunha, P., Pinho, D. F., Nwachukwu, C., Xi, Y., Frame, R., & Albuquerque, K. (2021) · Practical Radiation Oncology · doi:10.1016/j.prro.2020.12.004 · Cited by 8
Vijayram, R., Damaraju, N., Xavier, A., Desiraju, B. K., Thiruvengadam, R., Misra, S., Chopra, S., Khurana, A., Wadhwa, N., GARBH-Ini Study Group, et al. (2021) · BMC Pregnancy and Childbirth · doi:10.1186/s12884-021-03807-4 · Cited by 9
Validation of the FRESH Austin food frequency questionnaire using multiple 24-h dietary recalls
Jovanovic, C. E. S., Whitefield, J., Hoelscher, D. M., Chen, B., Ranjit, N., & van den Berg, A. E. (2021) · Public Health Nutrition · doi:10.1017/s1368980021002214 · Cited by 8
Terjesen, T., & Horn, J. (2021) · Journal of Pediatric Orthopaedics · doi:10.1097/bpo.0000000000001875 · Cited by 8
Assessing Sciatic Nerve Excursion and Strain with Ultrasound Imaging during Forward Bending
Ellis, R. F., Richards, N., Archer, L., Whittington, C., & Mawston, G. A. (2021) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2021.05.018 · Cited by 10
Ruggiero, L., Bruce, C. D., Streight, H., & McNeil, C. J. (2021) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00211.2021 · Cited by 10
Eriksson, J. S., Olsson, K. S. E., Rosdahl, H. G., & Schantz, P. (2021) · Frontiers in Physiology · doi:10.3389/fphys.2021.687566 · Cited by 8
Sato, H., Kuniyasu, K., Kobara, K., Okada, Y., Kawashima, T., Shinonaga, A., Yamamoto, S., Yasunaga, M., & Hanayama, K. (2018) · Japanese Journal of Comprehensive Rehabilitation Science · doi:10.11336/jjcrs.9.66 · Cited by 13
Banasiuk, M., Dobrowolska, M., Skowrońska, B., Konys, J., & Banaszkiewicz, A. (2021) · Digestive Diseases · doi:10.1159/000518357 · Cited by 8
Modest decrease in severity of obesity in adolescence associates with low arterial stiffness
Saner, C. C. S., Laitinen, T. T., Nuotio, J., Arnup, S. J., Harcourt, B. E., Bekkering, S., McCallum, Z., Kao, K., Janner, M., Magnussen, C. G., et al. (2021) · Atherosclerosis · doi:10.1016/j.atherosclerosis.2021.09.013 · Cited by 8
Okabe, T., Savona, S. J., Matto, F., Ward, C. C., Singh, P., Afzal, M. R., Kalbfleisch, S. J., Weiss, R., Houmsse, M., Augostini, R. S., et al. (2021) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.15249 · Cited by 8
Franco, D. C., Farias, G. S., Pelegrini, A., Júnior, J. S. V., & de Sousa, T. F. (2021) · Revista Brasileira de Atividade Física & Saúde · doi:10.12820/rbafs.26e0223 · Cited by 17
Barr, R. G., Cestone, A., & SILVESTRI, A. D. (2021) · Journal of Ultrasound in Medicine · doi:10.1002/jum.15870 · Cited by 10
Comparison of Three Assays for Total and Free PSA Using Hybritech and WHO Calibrations
Garrido, M. M., Marta, J. C., Ribeiro, R. M., Pinheiro, L. C., Holdenrieder, S., & Guimarães, J. T. (2021) · In Vivo · doi:10.21873/invivo.12643 · Cited by 8
Limón‐Miró, A. T., Jackson, C. D., Eslamparast, T., Yamanaka‐Okumura, H., Plank, L. D., Henry, C. J., Madden, A. M., Ferreira, L. G., Kalaitzakis, E., de Frías, C. P., et al. (2022) · Journal of Hepatology · doi:10.1016/j.jhep.2022.01.005 · Cited by 8
Mahinrad, S., Tan, C. O., Ma, Y., Aristova, M., Milstead, A., Lloyd‐Jones, D. M., Schnell, S., Markl, M., & Sorond, F. A. (2022) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.28115 · Cited by 8
Neyton, L., Gröger, F., Rattier, S., & Hirakawa, Y. (2022) · JSES International · doi:10.1016/j.jseint.2022.01.005 · Cited by 9
Assessment of resting energy expenditure in mechanically ventilated patients
Barak, N. (2004) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/79.2.341a · Cited by 8
Ultrasonography for Cervical Length Measurement
Carr, D. B., Smith, K. M., PARSONS, L., Chansky, K., & Shields, L. E. (2000) · Obstetrics and Gynecology · doi:10.1097/00006250-200010000-00014 · Cited by 9
Video Voiding Device for Diagnosing Lower Urinary Tract Dysfunction in Men
Shokoueinejad, M., Alkashgari, R., Mosli, H. A. M., Alothmany, N., Levin, J. M., & Webster, J. G. (2017) · Journal of Medical and Biological Engineering · doi:10.1007/s40846-017-0283-8 · Cited by 8
Borghesi, A., Salvo, D. D., Ciolli, P., Falcone, T., Ravanelli, M., Farina, D., & Carapella, N. (2022) · Journal of Imaging · doi:10.3390/jimaging8060161 · Cited by 8
Bugge, H. F., Guterud, M., Røislien, J., Larsen, K., Ihle‐Hansen, H., Toft, M., Hov, M. R., & Sandset, E. C. (2022) · BMJ Innovations · doi:10.1136/bmjinnov-2022-000968 · Cited by 8
Blay, G. L., Atamaz, F. C., Biot, B., Calmels, P., & Mouilleseaux, B. (2007) · Isokinetics and Exercise Science · doi:10.3233/ies-2007-0267 · Cited by 9
(2016) · doi:10.1128/9781555819071.ch50 · Cited by 8
Stegeman, S. A., de Witte, P. B., Boonstra, S., de Groot, J. H., Nagels, J., Krijnen, P., & Schipper, I. B. (2015) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2015.07.007 · Cited by 8
Echevarría-Uraga, J. J., García-Alonso, I., Plazaola, Insausti, M., Etxebarría, N., Saiz-Lopez, & Fernández-Ruanova, B. (2012) · International Journal of Nanomedicine · doi:10.2147/ijn.s31302 · Cited by 8
Argollo, A. P. B., Faustino, T. N., Faustino, T. N., & Pedreira, L. C. (2010) · Revista Brasileira de Terapia Intensiva · doi:10.1590/s0103-507x2010000400007 · Cited by 8
Accurate data collection for head injury monitoring studies: a data validation methodology
Barnes, J., Chambers, I. R., Piper, I., Citerio, G., Contant, C., Enblad, P., Fiddes, H., Howells, T. P., Kiening, K. L., Nilsson, P., et al. (2005) · Acta neurochirurgica. Supplementum · doi:10.1007/3-211-32318-x_9 · Cited by 8
9 Reliability of measurements in medical research and clinical practice
Downham, D. Y., Holmbäck, A. M., & Lexell, J. E. (2005) · Studies in multidisciplinarity · doi:10.1016/s1571-0831(06)80013-4 · Cited by 8
Filho, M. J. C. D. N. S., Gonçalves, A. V., Viana, M. T., Peixoto, D. M., SARINHO, E. S. C., & Rizzo, J. Â. (2015) · Annals of Allergy Asthma & Immunology · doi:10.1016/j.anai.2015.07.009 · Cited by 11
Analogue and digital electrocardiogram recordings in the assessment of heart rate variability
Simula, Laitinen, & Hartikainen (1998) · Clinical Physiology · doi:10.1046/j.1365-2281.1998.00089.x · Cited by 8
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.