STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 35,001–35,100 of 47,868
Liu, N. T., Kramer, G. C., Khan, M. N., Kinsky, M. P., & Salinas, J. (2015) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/ta.0000000000000573 · Cited by 6
Shuai, W., Wang, X., Hong, K., Peng, Q., Li, J., Li, P., Cheng, X., & Su, H. (2016) · International Journal of Cardiology · doi:10.1016/j.ijcard.2016.08.091 · Cited by 6
The Essential Aspects of Multivariate Calibration Transfer
Workman, J. (2015) · ACS symposium series · doi:10.1021/bk-2015-1199.ch011 · Cited by 6
Maloni, R., de Albuquerque, A. L. P., Jaeger, T., de Carvalho, C. R. R., & Caruso, P. (2017) · Respiratory Care · doi:10.4187/respcare.04849 · Cited by 7
Boer, P. (2016) · Journal of Intellectual Disability Research · doi:10.1111/jir.12345 · Cited by 6
Using consumer-grade devices for multi-imager non-contact imaging photoplethysmography
Blackford, E. B., & Estepp, J. R. (2017) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2253409 · Cited by 6
(2006) · Nutrition & Food Science · doi:10.1108/nfs.2006.01736aab.005 · Cited by 7
Validity of Deuterium Oxide Dilution for the Measurement of Body Fat among Singaporeans
Deurenberg‐Yap, M., & Deurenberg, P. (2002) · Food and Nutrition Bulletin · doi:10.1177/15648265020233s106 · Cited by 8
Soncini, M., Manfredi, G., Redaelli, A. C. L., Attanasio, A., Tosoni, A., Venturino, M., & Susini, G. (2002) · Journal of Clinical Monitoring and Computing · doi:10.1023/a:1016303524970 · Cited by 6
Refinement and revalidation of the Equine Acute Abdominal Pain Scale (EAAPS).
Sutton, G. A., & Bar, L. (2016) · Israel journal of veterinary medicine · Cited by 6
Robinson, Y., Cristancho, E., & Boning, D. G. (2004) · PubMed · Cited by 6
Morgan, J. A. (2014) · Scholarship@Western (Western University) · Cited by 13
An Introduction to High-Throughput Bioinformatics Data
Baggerly, K., Coombes, K. R., & Morris, J. S. (2006) · Cambridge University Press eBooks · doi:10.1017/cbo9780511584589.002 · Cited by 6
A Small-Angled Thin Edge of the Placenta Predicts Abnormal Placentation at Delivery
Shukunami, K., Nishijima, K., Kurokawa, T., Tajima, K., KAMITANI, N., Yoshida, Y., & Kotsuji, F. (2005) · Journal of Ultrasound in Medicine · doi:10.7863/jum.2005.24.3.331 · Cited by 8
JOINT HOMEOSTASIS IN TISSUE ENGINEERING FOR CARTILAGE REPAIR
Saris, D. B. F. (2002) · Utrecht University Repository (Utrecht University) · Cited by 6
Martin, C. B., Shaw, A., Gal, J., Aravindan, N., Murphy, F., Royston, D., & Riedel, B. (2005) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2005.03.003 · Cited by 6
Validity of rapid estimation of erythrocyte volume in the diagnosis of polycytemia vera
Nielsen, S., & R�dbro, P. (1989) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/bf00253596 · Cited by 6
Palka, P., Lange, A., Ferrington, C., & Fox, K. A. A. (2000) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(00)90020-8 · Cited by 6
Vancomycin Assay Performance in Patients with End‐Stage Renal Disease Receiving Hemodialysis
Kingery, J. R., Sowinski, K. M., Kraus, M. A., Klaunig, J. E., & Mueller, B. A. (2000) · Pharmacotherapy The Journal of Human Pharmacology and Drug Therapy · doi:10.1592/phco.20.7.653.35177 · Cited by 6
Drake, H., Smith, M., Corfield, D. R., & Treasure, T. (1989) · Intensive Care Medicine · doi:10.1007/bf00255600 · Cited by 6
Rehm, M., Haller, M., Brechtelsbauer, H., Akbulut, C., & FINSTERER, U. (1998) · Transfusion Medicine and Hemotherapy · doi:10.1159/000053428 · Cited by 6
Kannisto, S., Vanninen, E. J., Remes, K., & Korppi, M. O. (1999) · Pediatric Allergy and Immunology · doi:10.1034/j.1399-3038.1999.00037.x · Cited by 6
The effect of a time delay on the measurement of capillary blood gases
Bird, C. M., Revill, S. M., Vara, D. D., & Morgan, M. D. L. (1996) · Respiratory Medicine · doi:10.1016/s0954-6111(96)90207-3 · Cited by 6
Predicting Peak Oxygen Uptake Among Older Patients With Chronic Illness
Dominick, K. L., Gullette, E. C. D., Babyak, M. A., Mallow, K. L., Sherwood, A., WAUGH, R. A., Chilikuri, M., Keefe, F. J., & Blumenthal, J. A. (1999) · Journal of Cardiopulmonary Rehabilitation · doi:10.1097/00008483-199903000-00001 · Cited by 6
The effect of hypothermia on calculated values using saline and automated air tonometry
Chapman, M., Woolf, R. L., Bennett-Guerrero, E., & Mythen, M. G. (2002) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/jcan.2002.124138 · Cited by 6
Noninvasive measurements of cardiac output in sheep: an improved thermometry method
Serikov, V. B., & Jerome, E. H. (1997) · Medical Engineering & Physics · doi:10.1016/s1350-4533(97)00021-0 · Cited by 6
Vickers, A. J., & McCarney, R. (2003) · Controlled Clinical Trials · doi:10.1016/j.cct.2003.10.001 · Cited by 6
Teragaki, M., Takeuchi, K., Toda, I., Muro, T., Watanabe, H., Tani, T., Akioka, K., & Yoshikawa, J. (1999) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(99)70035-0 · Cited by 6
Direct intra-abdominal pressure monitoring via piezoresistive pressure measurement: a technical note
Otto, J., Kämmer, D., Binnebösel, M., Jansen, M., Dembinski, R., Schumpelick, V., & Schachtrupp, A. (2009) · BMC Surgery · doi:10.1186/1471-2482-9-5 · Cited by 6
Boyle, M., Jacobs, S., Torda, T. A., & Shehabi, Y. (1997) · Australian Critical Care · doi:10.1016/s1036-7314(97)70380-1 · Cited by 6
A simple, reliable method of assessing exercise capacity in patients with chronic heart failure
Asakuma, S., Fujiwara, M., Ohyanagi, M., & Iwasaki, T. (1999) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199901000-00010 · Cited by 6
Kimura, S., Iyama, S., Yamaguchi, Y., & Kanakura, Y. (2001) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.1044 · Cited by 6
Theophylline in Oral Mucosal Transudate: A Practical Method for Monitoring Outpatient Therapy
Holden, W. E., Bartos, F., Theime, T., Green, T. R., & Fitchen, J. H. (1993) · American Review of Respiratory Disease · doi:10.1164/ajrccm/147.3.739 · Cited by 6
Borrmann, S., Oyakhirome, S., Esser, G., Trinkle, C., Issifou, S., Grobusch, M. P., Krishna, S., & Kremsner, P. G. (2004) · American Journal of Tropical Medicine and Hygiene · doi:10.4269/ajtmh.2004.71.691 · Cited by 6
Shiota, T., Omoto, R., Cobanoglu, A. M., Kyo, S., Rice, M. J., Sandhu, S., Smith, L. S., & Sahn, D. J. (1997) · The American Journal of Cardiology · doi:10.1016/s0002-9149(97)00618-8 · Cited by 6
Bladbjerg, E., Overgaard, K., Gram, J., & Jespersen, J. (1995) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365519509089623 · Cited by 6
Primary care drug therapy training: the solution for phc nurses?
Rothmann, J. C., & Gerber, J. J. (2000) · Curationis · doi:10.4102/curationis.v23i1.592 · Cited by 6
Predictive accuracy of bioelectrical impedance equations corrected for fat‐free body size
Wilson, W. L., Heyward, V. H., Cook, K. L., Hicks, V. L., Jenkins, K. A., Quatrochi, J. A., & Colville, B. C. (1992) · American Journal of Human Biology · doi:10.1002/ajhb.1310040307 · Cited by 6
Aksakal, E., Kaya, A., Bakırcı, E. M., Kurt, M., Tanboğa, İ. H., Sevimli, S., & Açıkel, M. (2012) · The Anatolian Journal of Cardiology · doi:10.5152/akd.2012.153 · Cited by 6
Measurement of cardiac output-transtracheal Doppler versus thermodilution
Froese, N. R., & Friesen, R. M. (1991) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03036977 · Cited by 6
Precision and quantitation in capillary electrophoresis
Ross, G. A. (1997) · Springer eBooks · doi:10.1007/978-94-009-1561-9_4 · Cited by 6
Noncontact Extraction of Human Arterial Pulse with a Commercial Digital Color Video Camera
Davila, M. I. (2012) · Figshare · Cited by 6
Development of Novel Technologies for Improved Natural Illumination of High Rise Office Buildings
Greenup, P. (2004) · Cited by 6
Analysis of Total Hip Replacements Using Active Ellipses
Stuart Kerrigan, A., McKenna, S. J., Ricketts, I. W., & Wigderowitz, C. A. (2003) · Worcester Research and Publications (University of Worcester) · Cited by 6
Premature discharge from military service : Risk factors and preventive interventions
Larsson, H. (2009) · Figshare · Cited by 10
Mobile systems for monitoring Parkinson's disease
Memedi, M. (2014) · Dalarna University College Electronic Archive · doi:10.13140/rg.2.1.4656.2644 · Cited by 16
Bohlin‐Nizzetto, P. (2010) · Gothenburg University Publications Electronic Archive (Gothenburg University) · Cited by 7
Schwid, H. A., & Rooke, G. A. (2000) · Journal of Clinical Monitoring and Computing · doi:10.1023/a:1009933029279 · Cited by 6
Limited Linear Range of the Abbott AxSYM Serum and Erythrocyte Folate Methods
Manzella, S. M., Gronowski, A. M., Ladenson, J. H., & Scott, M. G. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.4.582 · Cited by 6
Bevilacqua, M. T., Vago, T., Baldi, G., Norbiato, G., Masson, S., & Latini, R. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.12.2439 · Cited by 6
Blood pressure measurement using oscillometric finger cuffs in children and young adults
Lyew, M. A., & Jamieson, J. (1994) · Anaesthesia · doi:10.1111/j.1365-2044.1994.tb04270.x · Cited by 6
Francq, B., & Govaerts, B. G. (2014) · RePEc: Research Papers in Economics · Cited by 6
The reproducibility of colour-coded duplex scanning in measuring arterial wall dimensions
Ellis, M. J., Cuming, R., Laing, S., Vashisht, R., Franks, P. J., Greenhalgh, R. M., & O’Malley, M. K. (1992) · European Journal of Vascular Surgery · doi:10.1016/s0950-821x(05)80284-1 · Cited by 6
Lim, R., Dyke, L., Thomas, J., & Dymond, D. S. (1993) · Heart · doi:10.1136/hrt.70.3.226 · Cited by 6
Effect of residual noise level on reproducibility of the signal-averaged ECG
Christiansen, E. H., Frost, L., Mølgaard, H., Nielsen, T. T., & Pedersen, A. K. (1996) · Journal of Electrocardiology · doi:10.1016/s0022-0736(96)80086-0 · Cited by 6
Stoel, B. C., Parr, D. G., Bakker, E. M., Putter, H., & Stolk, J. N. (2008) · Radiology · doi:10.1148/radiol.2471071608 · Cited by 6
Clinical performance of the LCx® HCV RNA quantitative assay
Bertuzis, R., Hardie, A., Hottenträger, B., Izopet, J., Jilg, W., Kaesdorf, B. A., Leckie, G. W., Leete, J. K., Perrin, L. H., Qiu, C., et al. (2004) · Journal of Virological Methods · doi:10.1016/j.jviromet.2004.09.020 · Cited by 6
岡橋, 典., Watanabe, N., Yamaura, Y., Wada, N., Neishi, Y., Kawamoto, T., Toyota, E., Okura, H., Ogasawara, Y., & Yoshida, K. (2007) · Journal of Echocardiography · doi:10.2303/jecho.5.32 · Cited by 6
Bilge, A. R., Stein, P. K., Domitrovich, P. P., Gérard, P., Rottman, J. N., Kleiger, R. E., KULBERTUS, H. E., & Piérard, L. (1999) · International Journal of Cardiology · doi:10.1016/s0167-5273(99)00085-6 · Cited by 6
Automated blood pressure measurement in atrial fibrillation
Cheng, H., Tufănaru, C., Pearson, A., & Chen, C. H. (2012) · Journal of Hypertension · doi:10.1097/hjh.0b013e32835ae9a3 · Cited by 6
Marcus, M. A., Wang, J., Pi-Sunyer, X., Thornton, J. C., Kofopoulou, I., & Pierson, R. N. (1998) · American Journal of Human Biology · doi:10.1002/(sici)1520-6300(1998)10:3<351::aid-ajhb10>3.0.co;2-7 · Cited by 6
A Proficiency Score for Assessing the Reliability of Self Blood Glucose Monitoring
Pollard, R. H., Bridgman, J. F., North, M., & Reid, J. M. (1988) · Diabetic Medicine · doi:10.1111/j.1464-5491.1988.tb01033.x · Cited by 6
Use of electronic callipers for radiological and clinical measurements
Solanki, G. A., Tammam, A. G., Crockard, H. A., & Stevens, J. (1996) · The Lancet · doi:10.1016/s0140-6736(96)90902-2 · Cited by 6
Preliminary clinical trial of an ex vivo arterial blood gas monitor
McKinley, B. A., & Parmley, C. L. (1997) · Journal of Critical Care · doi:10.1016/s0883-9441(97)90035-6 · Cited by 6
Gaujoux, T., Borderie, V. M., Yousfi, H., Bourcier, T., Touzeau, O., & Laroche, L. (2007) · Cornea · doi:10.1097/01.ico.0000248387.62637.12 · Cited by 6
Reilly, J. J., Murray, L. A., Wilson, J. W., & Durnin, J. V. G. A. (1994) · Annals of Human Biology · doi:10.1080/03014469400003622 · Cited by 6
Bardsley, M., VENNING, P. M., CHAM, C. W., Hasan, T. S., & Neal, D. E. (1992) · British Journal of Urology · doi:10.1111/j.1464-410x.1992.tb15562.x · Cited by 6
Feldman, B. M., & Pullaneyagum, E. (2014) · Haemophilia · doi:10.1111/hae.12587 · Cited by 6
Measurement of oxygen uptake in newborn infants during assisted and spontaneous ventilation
Rozé, J., Chambille, B., Dehan, M., & Gaultier, C. (1994) · Respiration Physiology · doi:10.1016/0034-5687(94)00056-5 · Cited by 6
Pai, R. G., & Stoletniy, L. N. (1998) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(98)70039-2 · Cited by 6
Todino, V., Rubini, G., & Cuocolo, A. (1999) · Journal of Nuclear Cardiology · doi:10.1016/s1071-3581(99)90097-1 · Cited by 6
Another portable quantitative capnometer
Maleck, W. H., Petroianu, G. A., Toomes, L. M., Jatzko, A., & Rufer, R. (1998) · The American Journal of Emergency Medicine · doi:10.1016/s0735-6757(98)90139-5 · Cited by 6
Nicolson, S. C., Jobes, D. R., Steven, J. M., Hillyer, P., & Handrahan, J. V. (1989) · Journal of Cardiothoracic Anesthesia · doi:10.1016/s0888-6296(89)95002-3 · Cited by 6
Renal transplantation in tuberous sclerosis.
Pirson, Y. (1992) · BMJ · doi:10.1136/bmj.305.6848.313-a · Cited by 6
Application of Color Doppler Flow Mapping to Calculate Orifice Area of St Jude Mitral Valve
Leung, D. Y., Wong, J., Rodríguez, L., Pu, M., Vandervoort, P. M., & Thomas, J. D. (1998) · Circulation · doi:10.1161/01.cir.98.12.1205 · Cited by 6
Sources of Variability in Posterior Rhinomanometry
James, D. S., Lambert, W. E., Stidley, C. A., Chick, T. W., Mermier, C. M., & Samet, J. M. (1993) · Annals of Otology Rhinology & Laryngology · doi:10.1177/000348949310200812 · Cited by 6
Response to letter by Werner et al.
Geber, C., Treede, R., & Magerl, W. (2012) · Pain · doi:10.1016/j.pain.2012.10.012 · Cited by 7
Within‐clinic Reagent Strip Lipid Measurement
Neil, H. A. W., Alberti, K. G. M. M., Cassidy, D. M., & Laker, M. F. (1989) · Diabetic Medicine · doi:10.1111/j.1464-5491.1989.tb01289.x · Cited by 6
A laboratory assessment of the miles glucometer elite blood glucose meter
MacLinnon, D. T., & Henderson, A. R. (1994) · Clinical Biochemistry · doi:10.1016/0009-9120(94)00057-3 · Cited by 6
Spoeck, A., Bonatti, J. O., Friedrich, G. J., Schachner, T., Bonaros, N. E., & Feuchtner, G. M. (2008) · The Heart Surgery Forum · doi:10.1532/hsf98.20081046 · Cited by 6
Twitchett, E. A. (2009) · Wolverhampton Intellectual Repository and E-Theses (University of Wolverhampton) · Cited by 21
An automated algorithm for analysis of 2-D echocardiographic short-axis images: a brief overview
Wilson, D. C., Geiser, E. A., Conetta, D. A., Murphy, J. M., & Wang, D. (1996) · IEEE Workshop on Mathematical Methods in Biomedical Image Analysis (MMBIA) · doi:10.1109/mmbia.1996.534074 · Cited by 6
Leakage and absorption of isoflurane by different types of anaesthetic circuit and monitoring tubing
Smith, C. V., Flynn, C., Wardall, G. J., & Broome, I. J. (2002) · Anaesthesia · doi:10.1046/j.1365-2044.2002.02614.x · Cited by 6
Gaihede, M. L., Felding, J. U., & Elbrønd, O. (1995) · Acta Oto-Laryngologica · doi:10.3109/00016489509139340 · Cited by 6
Elia, M., Fuller, N. J., Fotherby, K., & Allwood, M. C. (1987) · Clinical Nutrition · doi:10.1016/0261-5614(87)90042-2 · Cited by 6
Inventaire des échelles évaluant le statut fonctionnel des cervicalgiques
Demaille-Wlodyka, S. (2004) · Revue du Rhumatisme · doi:10.1016/j.rhum.2004.06.001 · Cited by 6
Noninvasive assessment of great cardiac vein flow by Doppler echocardiography: A validation study
Watanabe, N., Akasaka, T., Yamaura, Y., Kamiyama, N., Akiyama, M., Koyama, Y., Neishi, Y., & Yoshida, K. (2002) · Journal of the American Society of Echocardiography · doi:10.1067/mje.2002.119788 · Cited by 6
Takemoto, Y., Tanabe, K., Chandrasekaran, K., Ballman, K. V., Seward, J. B., & Belohlavek, M. (2003) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(03)00003-8 · Cited by 6
Kau, N., GÜNTHER, M., Fahnenstich, H., Kowalewski, S., & Bartmann, P. (1995) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.1995.tb04343.x · Cited by 6
Kabal, J., & Lagerman, B. K. (2003) · Journal of Clinical Monitoring and Computing · doi:10.1023/b:jocm.0000042917.59182.c5 · Cited by 6
Point-of-Care Measurements on a Neonatal Intensive Care Unit Using the OMNI-S Blood Gas Analyzer
Arthurs, O. J., Dey, P., Pattnayak, S., Bewley, B., MacDonald, A., & Kelsall, W. (2007) · Point of Care The Journal of Near-Patient Testing & Technology · doi:10.1097/01.poc.0000271405.60677.8d · Cited by 6
Kilner, P. J., Shinohara, T., Sampson, C., Mohiaddin, R. H., Firmin, D. N., & Somerville, J. (1996) · Cardiology in the Young · doi:10.1017/s104795110000319x · Cited by 6
Ansell, J. K., de Jode, M. L., & Grahn, M. F. (1997) · Lasers in Medical Science · doi:10.1007/bf02767156 · Cited by 6
Accuracy of Portable Blood Glucose Monitors
Aboezz, R., & Miller, D. R. (2005) · Journal of the American Pharmacists Association · doi:10.1331/1544345054475577 · Cited by 6
Py, M. O., André, C., & de Azevedo, F. S. (2001) · Arquivos de Neuro-Psiquiatria · doi:10.1590/s0004-282x2001000500003 · Cited by 6
Induction of right ventricular hypertrophy with obstructing balloon catheter.
Wernovsky, G., & Colan, S. D. (1994) · Circulation · doi:10.1161/01.cir.89.4.1911 · Cited by 6
Rowlands, A. V., & Eston, R. G. (2000) · KARGER eBooks · doi:10.1159/000061763 · Cited by 6
Paul, A. K., Hasegawa, S., Yoshioka, J., Yamaguchi, H., 辻村, 英., & Nishimura, T. (2000) · Annals of Nuclear Medicine · doi:10.1007/bf02988584 · Cited by 6
Sohn, I. S., Kang, H. S., Kim, S., Choue, C. W., Kim, K. S., Song, J. S., & Bae, J. H. (2005) · Korean Circulation Journal · doi:10.4070/kcj.2005.35.4.315 · Cited by 6
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.