STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 34,901–35,000 of 47,868
Clinical Evaluation of the Dynamic Observing Tonometer
Morgan, A. J., Hosking, S. L., & Salmon, J. F. (2002) · Journal of Glaucoma · doi:10.1097/00061198-200208000-00010 · Cited by 6
Shors, S. M., Cotts, W., Pavlovic-Surjancev, B., Gheorghiade, M., Carr, J., McCarthy, R. M., Pereles, S., & Finn, J. P. (2005) · Heart Failure Reviews · doi:10.1007/s10741-005-7540-6 · Cited by 7
The Acidic Probe LysoSensor™is not Useful for Acrosome Evaluation of Cryopreserved Ram Spermatozoa
Castro-González, D., Alvarez, M., Muro, J., Esteso, M., de Paz, P., Anel, L., & Martínez‐Pastor, F. (2009) · Reproduction in Domestic Animals · doi:10.1111/j.1439-0531.2008.01333.x · Cited by 6
Kanagasundaram, N. S., Larive, A. B., & Paganini, E. P. (2000) · Kidney International · doi:10.1046/j.1523-1755.2000.00444.x · Cited by 6
Lambertz, H., Flachskampf, F. A., Heiliger, R., Krebs, W., Behrens, B., & Schmitz, E. (1989) · International journal of cardiac imaging · doi:10.1007/bf01745231 · Cited by 6
Reflex Tear Ascorbate in Hong Kong Chinese Subjects: Method Comparison and Biological Variation
Choy, C. K. M., Cho, P., Chung, W.-Y., & Benzie, I. F. F. (2003) · Optometry and Vision Science · doi:10.1097/00006324-200309000-00007 · Cited by 6
Characterization of the Upper Limb Arterial Properties during Reactive Hyperemia
Dobson, G. M., Chong, M., Walker, M., Petrasek, P. F., Johnston, C. R., Tyberg, J. V., & Karamanoglu, M. (2007) · Cardiovascular Engineering An International Journal · doi:10.1007/s10558-007-9032-x · Cited by 6
Estimation of extracellular space and blood volume using bioelectrical impedance measurements
Miholic, J., Reilmann, L., Meyer, H. J., K�rber, H., Dieckelmann, A., & Pichlmayrl, R. (1992) · Journal of Molecular Medicine · doi:10.1007/bf00184802 · Cited by 7
Verification of the vertex powers of varifocal rigid contact lenses
Woods, C. A. (2003) · Contact Lens and Anterior Eye · doi:10.1016/s1367-0484(03)00050-x · Cited by 6
Shimada, S., Harada, K., Toyono, M., Tamura, M., & Takada, G. (2007) · Circulation Journal · doi:10.1253/circj.71.1912 · Cited by 6
Hannequin, P., Weinmann, P., Mas, J. L., & Vinot, S. (2001) · Journal of Nuclear Cardiology · doi:10.1067/mnc.2001.111799 · Cited by 6
Strain-gauge fontanometry-an advance in non-invasive intracranial pressure measurement
Pairaudeau, P., Smith, S. L., Hames, T. K., & Hall, M. A. (1990) · Clinical Physics and Physiological Measurement · doi:10.1088/0143-0815/11/2/002 · Cited by 6
Assessing Levels of Agreement between Two Commonly Used Oral Health‐Related Quality of Life Measures
Bernabé, E., de Oliveira, C. M., Sheiham, A., & Tsakos, G. (2009) · Journal of Public Health Dentistry · doi:10.1111/j.1752-7325.2008.00112.x · Cited by 6
Benchmarking a computerized test of immediate verbal memory
Tractenberg, R. E., & Freas, C. E. (2007) · Behavior Research Methods · doi:10.3758/bf03192980 · Cited by 7
Kargın, R., Esen, Ö., Akçakoyun, M., Pala, S., Candan, Ö., Omaygenç, M. O., Doğan, C., Barutçu, İ., Esen, A. M., & Özdemir, N. (2010) · PubMed · Cited by 6
Murase, K., Kitamura, A., Tachibana, A., Kusakabe, Y., Matsuura, R., & Miyazaki, S. (2009) · European Journal of Radiology · doi:10.1016/j.ejrad.2009.03.006 · Cited by 6
Retest Variability of Human Infant Contrast Sensitivity: How Many Tests Are Sufficient?
Adams, R. J., Courage, M. L., & Drover, J. R. (2000) · Optometry and Vision Science · doi:10.1002/j.1538-9235.2000.tb01038.x · Cited by 6
Otsuji, Y., Kisanuki, A., Toyonaga, K., Hamasaki, S., Arima, S., Nakao, S., Okino, H., Toda, H., Akiba, S., & Tanaka, H. (1996) · The American Journal of Cardiology · doi:10.1016/s0002-9149(96)00281-0 · Cited by 6
Comparison of monitoring performance of bioreactance versus esophageal Doppler in pediatric patients
Dubost, C., Bouglé, A., Hallynck, C., Dorze, M. L., Roulleau, P., Baujard, C., & Benhamou, D. (2015) · Indian Journal of Critical Care Medicine · doi:10.4103/0972-5229.148630 · Cited by 6
Simplified approach to MR image quantification of the rheumatoid wrist: a pilot study
Kamishima, T., Tanimura, K., Aoki, Y., Kosaka, N., Shimizu, M., Matsuhashi, M., Fukae, J., Kon, Y., Terae, S., & Shirato, H. (2010) · Skeletal Radiology · doi:10.1007/s00256-010-0935-z · Cited by 6
Consistency and Agreement of Two Devices for Running Speed
Hovsepian, D. G., Meardon, S. A., & Kernozek, T. W. (2014) · Athletic Training & Sports Health Care · doi:10.3928/19425864-20140306-02 · Cited by 6
Schaefer, C., Lerner, M. R., & Biber, B. (1995) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.1995.tb05591.x · Cited by 6
Sombolos, K., Tsakiris, D., Boletis, J., Vlahakos, D., Siamopoulos, K. C., Vargemezis, V. A., Nikolaidis, P., Iatrou, C., Dafnis, E., Xynos, K., et al. (2014) · PLoS ONE · doi:10.1371/journal.pone.0112767 · Cited by 6
Schafer, M. A., Goss, F. L., Robertson, R. J., Nagle-Stilley, E. F., & Kim, K. (2013) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2012-0446 · Cited by 10
Cisplatin-induced autonomic neuropathy: does it really exist?
Vandertop, W. P., de Vries, W. B., Notermans, N. C., Nijsen, M., Wildt, D. J. D., Tulleken, C. A. F., & Gispen, W. H. (1996) · Journal of Neuro-Oncology · doi:10.1007/bf00146084 · Cited by 6
Two-hour post-dose cyclosporine monitoring does not fit all in kidney transplantation
Cattaneo, D., Gaspari, F., Zenoni, S., Baldelli, S., Gotti, E., Perna, A., Perico, N., & Remuzzi, G. (2005) · Therapy · doi:10.1586/14750708.2.1.95 · Cited by 6
Smith, A. W., & Wong, D. P. (2012) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2012.06.001 · Cited by 6
Heaney, L. G., Leggett, P. L., Maxwell, P., Bharucha, H., & Ennis, M. (1997) · Allergy · doi:10.1111/j.1398-9995.1997.tb02155.x · Cited by 6
Comparison of sputum induction using inhaled methacholine or hypertonic saline
JAMES, A. L., Maxwell, P. S., & Elliot, J. (2005) · Respirology · doi:10.1111/j.1440-1843.2005.00632.x · Cited by 6
Ho, W. ‐., Hung, W. T., Wu, C. C., Shen, C., Yang, N.-C., Hwang, K. L., & Wong, K. C. (2005) · Anaesthesia · doi:10.1111/j.1365-2044.2005.04280.x · Cited by 6
Pellerin, D., Cohen, L., Larrazet, F. S., Extramiana, F., Witchitz, S., & Veyrat, C. (2003) · European Journal of Echocardiography · doi:10.1053/euje.2002.0624 · Cited by 6
Predictable nitrous oxide uptake enables simple oxygen uptake monitoring during low flow anaesthesia
Bengtson, J. P., Bengtsson, A., & Stenqvist, O. (1994) · Anaesthesia · doi:10.1111/j.1365-2044.1994.tb03308.x · Cited by 6
Coronary Sinus Visualization by 3-dimensional Real-time Echocardiography
Conca, C., Faletra, F. F., Chioncel, O. D., Sorgente, A., Pasotti, E., Pedrazzini, G. B., Moccetti, T., & Auricchio, A. (2007) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2007.05.036 · Cited by 6
Analysis of the quality of wrist movement during a simple tracking task
Notley, S. V., Turk, R., Pickering, R. M., Simpson, D. M., & Burridge, J. H. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/8/011 · Cited by 6
Detection of physiological changes after exercise via a remote optophysiological imaging system
Sun, Y., Hu, S., Azorin-Peris, V., Zheng, J., Greenwald, S. E., Chambers, J. A., & Zhu, Y. (2011) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.872723 · Cited by 6
Moladoust, H., Mokhtari‐Dizaji, M., Ojaghi‐Haghighi, Z., Khaledifar, A., & Khajavi, A. (2009) · Echocardiography · doi:10.1111/j.1540-8175.2008.00822.x · Cited by 6
Sleutjes, B. T. H. M., Kemps, H., Thijssen, E. J. M., van de Vosse, F. N., Schep, G., Peters, C., & Wijn, P. F. F. (2007) · European Journal of Applied Physiology · doi:10.1007/s00421-007-0597-2 · Cited by 6
MEDIAN NERVE LATENCY MEASUREMENT AGREEMENT BETWEEN PORTABLE AND CONVENTIONAL METHODS
ATROSHI, I., Gummesson, C., Johnsson, R., Ornstein, E., & Rosén, I. (2000) · Journal of Hand Surgery (European Volume) · doi:10.1054/jhsb.1999.0316 · Cited by 6
Visualising disease progression on multiple variables with vector plots and path plots
Lazic, S. E., Mason, S., Michell, A. W., & Barker, R. A. (2009) · BMC Medical Research Methodology · doi:10.1186/1471-2288-9-32 · Cited by 6
Adequacy, Nutrition and Outcome in Peritoneal Dialysis; Is There a Link?
Gokal, R. (1997) · Seminars in Dialysis · doi:10.1111/j.1525-139x.1997.tb00862.x · Cited by 6
David, D., Lang, R. M., Marcus, R. H., Neumann, A., Spencer, K. T., Feldman, T. E., Carroll, J. D., Sareli, P., & Borow, K. M. (1991) · The American Journal of Cardiology · doi:10.1016/0002-9149(91)90889-s · Cited by 6
Vinyoles, E., Ribera, E. P., de la Figuera, M., Tajada, C., Montero, P., & García, D. (2005) · Medicina Clínica · doi:10.1157/13071766 · Cited by 6
Limited sampling strategies for sirolimus after pediatric renal transplantation
Forbes, N., Schachter, A. D., Yasin, A., Sharma, A. P., & Filler, G. (2008) · Pediatric Transplantation · doi:10.1111/j.1399-3046.2008.01110.x · Cited by 6
Abdissa, A., Wiesner, L., McIlleron, H., Friis, H., Andersen, Å. B., & Kæstel, P. (2014) · Journal of the International AIDS Society · doi:10.7448/ias.17.1.18979 · Cited by 6
Zhu, C., Patterson, A. J., Thomas, O., Sadat, U., Graves, M. J., & Gillard, J. H. (2012) · International journal of cardiac imaging · doi:10.1007/s10554-012-0148-8 · Cited by 6
Stephan, E., Delanaud, S., Bisch, C., Libert, J., & Telliez, F. (2006) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2006.07.006 · Cited by 6
Reutershan, J., Ressel, M., Wagner, T., Schröder, T., Dietz, K., & Fretschner, R. (2003) · Journal of Medical Engineering & Technology · doi:10.1080/0309190031000096667 · Cited by 6
Factors Affecting Prostate Volume Estimation in Computed Tomography Images
Yang, C.-H., Wang, S., Lin, A. T., & Lin, C. (2010) · Medical dosimetry · doi:10.1016/j.meddos.2010.01.002 · Cited by 6
Brix, T. H., Kyvik, K. O., & Hegedűs, L. D. (2002) · Twin Research · doi:10.1375/twin.5.4.308 · Cited by 6
Magota, K., Hattori, N., Manabe, O., Naya, M., Oyama‐Manabe, N., Shiga, T., Kuge, Y., YAMADA, S., Sakakibara, M., Yoshinaga, K., et al. (2013) · Annals of Nuclear Medicine · doi:10.1007/s12149-013-0795-4 · Cited by 6
How to ensure your paper is rejected by the statistical reviewer
STRATTON, I. M., & Neil, A. (2005) · Diabetic Medicine · doi:10.1111/j.1464-5491.2004.01443.x · Cited by 6
Bastarrika, G., Gavira, J. J., Abizanda, G., Alonso‐Burgos, A., Ilzarbe, M., & Prósper, F. (2009) · Radiología · doi:10.1016/j.rx.2008.02.001 · Cited by 6
Evaluation of BD Vacutainer SST™ II plus tubes for special proteins testing
Li, Z., Yan, C., Yan, R., Zheng, X., & Feng, Z. (2011) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.20458 · Cited by 6
Intra-arterial haemodynamic changes during cerebral three-dimensional rotational angiography
Waldenberger, P., Chemelli, A., & Mallouhi, A. (2008) · European Radiology · doi:10.1007/s00330-008-1161-0 · Cited by 6
Quantification of regional pulmonary flow with99mTc-MAA SPECT and cine phase contrast MR imaging
Osada, H., Machida, K., & Honda, N. (2002) · Annals of Nuclear Medicine · doi:10.1007/bf02990082 · Cited by 6
Liang, R.-I., Prapas, N., Detti, L., Cosmi, E., Copel, J. A., & Mari, G. C. (2002) · Journal of Ultrasound in Medicine · doi:10.7863/jum.2002.21.1.31 · Cited by 6
James, G., & Scott, C. (2012) · Manual Therapy · doi:10.1016/j.math.2012.02.009 · Cited by 6
Tympanic measurement of body temperature in stroke patients "turned on its ear"
Rampen, A. J. J. (2005) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp.2004.058149 · Cited by 6
Morlet, N., Maloof, A. G., Wingate, N. A., & Lindsay, P. (1998) · British Journal of Ophthalmology · doi:10.1136/bjo.82.1.35 · Cited by 6
Dynamic contour tonometry over silicone hydrogel contact lens
Lam, A. K. C., & Tse, J. S.-H. (2013) · Journal of Optometry · doi:10.1016/j.optom.2013.07.005 · Cited by 6
Bland-Altman Analysis for Determining Agreement Between Two Methods
Eken, C. (2008) · Journal of Emergency Medicine · doi:10.1016/j.jemermed.2008.01.033 · Cited by 6
Tanaka, K., & Zelenitsky, D. K. (2014) · Canadian Journal of Zoology · doi:10.1139/cjz-2014-0078 · Cited by 7
Broka, S. M., Ducart, A. R., Jamart, J., Collard, E. L., Fournet, X., Chevalier, S., Marchandise, B. A., & Joucken, K. L. (1998) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1016/s1053-0770(98)90051-9 · Cited by 6
Palmieri, V. (2004) · European Journal of Echocardiography · doi:10.1016/j.euje.2004.01.008 · Cited by 6
RELIABILITY OF TORQUE MEASUREMENTS DURING PASSIVE ISOKINETIC KNEE MOVEMENTS IN HEALTHY SUBJECTS
Nuyens, W. D. W. G. (2000) · Scandinavian Journal of Rehabilitation Medicine · doi:10.1080/003655000750045569 · Cited by 6
Sewell, A., Heil, M., Blieke, A., Mosandl, A., & Böhles, H. J. (2000) · Clinical Chemistry · doi:10.1093/clinchem/46.9.1444 · Cited by 6
Visual function thresholds in children
Simmers, A. J., Gray, L. S., & Winn, B. (2000) · Current Eye Research · doi:10.1076/0271-3683(200008)2121-vft616 · Cited by 6
Design and Application of Noncontinuously Binding Probes Used for Haplotyping and Genotyping
Pont-Kingdon, G. A., Margraf, R. L., Sumner, K. L., Millson, A., Lyon, E., & Schütz, E. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.100487 · Cited by 6
Analysis of the double occlusion which provides four pressure gradients
Hakim, T., Sugimori, K., & Ferrario, L. (1996) · European Respiratory Journal · doi:10.1183/09031936.96.09122578 · Cited by 6
Benninger, E., Laschke, M. W., Cardell, M., Holstein, J. H., Seifert, B., Keel, M. J. B., Trentz, O., Menger, M. D., & Meier, C. (2009) · Journal of Surgical Research · doi:10.1016/j.jss.2008.11.849 · Cited by 6
Murray, I. J., Parry, N. R. A., Ritchie, S. I. M., Bremner, R. E., Brahma, A. K., Ikram, K., & Tahir, H. J. (2008) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2007.11.043 · Cited by 6
Early diastolic filling dynamics in diastolic dysfunction
King, G., Foley, J. B., Al-Mane, F., Crean, P., & Walsh, M. J. (2003) · Cardiovascular Ultrasound · doi:10.1186/1476-7120-1-9 · Cited by 6
Yao, G., Li, F., Zhang, C., Zhang, P.-F., Zhang, M., Zhao, Y.-X., Li, X.-N., Ding, S., Zhong, L., & Zhang, Y. (2007) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2007.04.013 · Cited by 6
Özlü, O., & Öcal, T. (1999) · Pediatric Anesthesia · doi:10.1046/j.1460-9592.1999.00393.x · Cited by 6
Deurenberg, P., van Malkenhorst, E., & Schoen, T. (1995) · American Journal of Human Biology · doi:10.1002/ajhb.1310070110 · Cited by 8
Espahbodi, S., Humphries, K. N., Doré, C. J., McCarthy, I. D., Standfield, N. J., Cosgrove, D. O., & Hughes, S. P. F. (2006) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2005.11.006 · Cited by 6
The agreement between two diagnostic methods in binary cases: a proposal
Renzo, J. C. A. (2002) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365510260296555 · Cited by 6
Hermanson, M. H., Moss, D. J., Monosmith, C. L., & Keeler, G. J. (2007) · Journal of Geophysical Research Atmospheres · doi:10.1029/2006jd007346 · Cited by 6
Light scatter changes due to corneal oedema and contact lens wear
Mitchell, S., & Elliott, D. B. (1991) · Journal of The British Contact Lens Association · doi:10.1016/0141-7037(91)80018-h · Cited by 6
Jordanoglou, J. B., Koulouris, N. G., Kyroussis, D., Rapakoulias, P., Vassalos, P., & Madianos, J. (1995) · Thorax · doi:10.1136/thx.50.3.240 · Cited by 8
Comparison of chlorzoxazone one-sample methods to estimate CYP2E1 activity in humans
Kramer, I., Dalhoff, K., Clemmesen, J. O., Loft, S. H., & Poulsen, H. E. (2003) · European Journal of Clinical Pharmacology · doi:10.1007/s00228-003-0695-y · Cited by 6
Liu, Y.-H., Fernando, G. P., & Sinusas, A. J. (2006) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2006.879823 · Cited by 6
Moseley, L., Jentjens, R. L. P. G., Waring, R. H., Harris, R. M., Harding, L. K., & Jeukendrup, A. E. (2005) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00423.2004 · Cited by 11
Schulze, R. K. W., Weinheimer, O., Brüllmann, D. D., Roder, F. L., D'Hoedt, B., & Schömer, E. (2005) · Dentomaxillofacial Radiology · doi:10.1259/dmfr/56357032 · Cited by 6
Early or Delayed Surgical Treatment of Supracondylar Humeral Fractures in Children
Mellor, S., & Patel, V. (2002) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-200206000-00028 · Cited by 6
Specific diving training-induced arterial circulation changes
Gole, Y., Louge, P., & Boussuges, A. (2007) · British Journal of Sports Medicine · doi:10.1136/bjsm.2007.043364 · Cited by 6
Fraser, L., Zasiadczyk, Ł., Lecewicz, M., & Kordan, W. (2011) · Cited by 6
Molina, C., Rodríguez, V., de Celis, E. M. R., Rodríguez, E. B., Ávila, G. G., & Ruiz, C. E. C. (2006) · Medicina Interna de México · Cited by 6
Zbar, A. P., & Beer-Gabel, M. (2006) · Springer eBooks · doi:10.1007/88-470-0507-8_22 · Cited by 6
Automated Blood Pressure Recording in Pregnancy
Brown, M., & Adsett, D. (1991) · Clinical and Experimental Hypertension Part B Hypertension in Pregnancy · doi:10.3109/10641959109079464 · Cited by 6
Itti, E., Rosso, J., Hammami, H., Benayoun, S., Thirion, J., & Meignan, M. A. (2001) · PubMed · Cited by 6
Reliability of the Q Force; a mobile instrument for measuring isometric quadriceps muscle strength
Douma, K. W., Regterschot, G. R. H., Krijnen, W. P., Slager, G. E. C., van der Schans, C. P., & Zijlstra, W. (2016) · BMC Sports Science Medicine and Rehabilitation · doi:10.1186/s13102-016-0029-x · Cited by 6
Marino, P. N., Barbieri, E., Prioli, M. A., & Zardini, P. (1997) · Journal of Cardiovascular Pharmacology · doi:10.1097/00005344-199702000-00006 · Cited by 6
Duncan, M. J., & Hankey, J. (2010) · Medicina Sportiva · doi:10.2478/v10036-010-0019-0 · Cited by 6
Balzer, J. C., Böring, Y. C., Mollus, S., Schmidt, M., Hellhammer, K., Kröpil, P., Westenfeld, R., Zeus, T., Antoch, G., Linke, A. H.-P., et al. (2014) · EuroIntervention · doi:10.4244/eijv10i3a60 · Cited by 6
Gerber, T. C., Schmermund, A., Reed, J. E., Rumberger, J. A., Sheedy, P. F., Gibbons, R. J., Holmes, D. R., & Behrenbeck, T. (2001) · Investigative Radiology · doi:10.1097/00004424-200104000-00001 · Cited by 6
Estimation of Total Daily Creatinine Clearance in Capd from Serum Creatinine Concentration
Jones, C. H., Newstead, C. G., & Will, E. J. (1997) · Peritoneal Dialysis International · doi:10.1177/089686089701700307 · Cited by 6
Intraoperative Assessment of the Lawrence 3000 Doppler Cardiac Output Monitor
Stein, M., Barratt, S. M., & Purcell, G. J. (1991) · Anaesthesia and Intensive Care · doi:10.1177/0310057x9101900219 · Cited by 6
Foucher, K., Toulon, P. A., Schved, J., & Polack, B. (2004) · Thrombosis and Haemostasis · doi:10.1055/s-0037-1614283 · Cited by 6
Tzamaloukas, A. H., Dombros, N., Murata, G. H., Nicolopoulou, N., Dimitriadis, A., Kakavas, J., Malhotra, S. D., Antoniou, S., Balaskas, E. V., & Voudiklaris, S. (1996) · Peritoneal Dialysis International · doi:10.1177/089686089601600209 · Cited by 6
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.