STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 35,801–35,900 of 47,868
Evaluation of a novel metric for personalized opioid prescribing after hospitalization
Iverson, N. R., Lau, C. Y., Abe‐Jones, Y., Fang, M. C., Kangelaris, K. N., Prasad, P. A., Shah, S. J., & Najafi, N. (2020) · PLoS ONE · doi:10.1371/journal.pone.0244735 · Cited by 5
Uçak, T. (2021) · Beyoglu Eye Journal · doi:10.14744/bej.2021.17894 · Cited by 5
Zakari, F. O., & Ayo, J. O. (2021) · International Journal of Biometeorology · doi:10.1007/s00484-021-02087-z · Cited by 5
Baroncelli, S., Galluzzo, C. M., Liotta, G., Andreotti, M., Jere, H., Luhanga, R., Sagno, J. B., Ciccacci, F., Orlando, S., Amici, R., et al. (2021) · Journal of Immunological Methods · doi:10.1016/j.jim.2021.113019 · Cited by 5
Agreement Between the TEG 6s and TEG 5000 Analyzers in Extracorporeal Membrane Oxygenation
Chandel, A., Desai, M., King, C. S., Patolia, S., Raja, A., Singh, R., & Dalton, H. J. (2021) · ASAIO Journal · doi:10.1097/mat.0000000000001398 · Cited by 5
Osuna‐Padilla, I. A. (2021) · Revista Médica del Instituto Mexicano del Seguro Social · doi:10.24875/rmimss.m20000016 · Cited by 6
Pattankar, S., Roy, R., Warade, A., & Desai, K. I. (2021) · Journal of Neurosciences in Rural Practice · doi:10.1055/s-0041-1723100 · Cited by 5
Employing multiple synchronous outcome samples per subject to improve study efficiency
A’Hern, R. (2021) · BMC Medical Research Methodology · doi:10.1186/s12874-021-01414-7 · Cited by 5
Lee, S., You, S., Yang, S., & Park, D.-S. (2021) · Physical therapy rehabilitation science · doi:10.14474/ptrs.2021.10.1.40 · Cited by 5
Nourrisson, C., Moniot, M., Poirier, P., & Sterkers, Y. (2021) · Journal of Molecular Diagnostics · doi:10.1016/j.jmoldx.2021.04.004 · Cited by 5
Tecchio, P., Monte, A., & Zamparo, P. (2021) · European Journal of Translational Myology · doi:10.4081/ejtm.2021.9735 · Cited by 6
de Castro, M., & Galea, M. (2021) · Quality Engineering · doi:10.1080/08982112.2021.1931317 · Cited by 5
Evaluation of an electronic system for monitoring dairy cow rumination in a grazing-based system
Kappes, R., Knob, D. A., Scheid, A. L., Bessani, D. T. D. C., Schaitz, L. H., Perazzoli, L., Alessio, D. R. M., & Neto, A. T. (2021) · Tropical Animal Health and Production · doi:10.1007/s11250-021-02833-w · Cited by 5
Blood pressure measurement: Should technique define targets?
Hiremath, S. S., Ramsay, T., & Ruzicka, M. (2021) · Journal of Clinical Hypertension · doi:10.1111/jch.14324 · Cited by 6
Tiba, M. H., McCracken, B. M., Leander, D. C., Colmenero, C. I., Greer, N. L., Picton, P., Williamson, C. A., & Ward, K. R. (2021) · Neurocritical Care · doi:10.1007/s12028-021-01272-7 · Cited by 5
Congruence of pain perceptions between Black cancer patients and their family caregivers
Yeager, K. A., Lee, H., Bai, J., Paul, S., Johnson, K. B., & Waldrop, D. G. (2021) · Supportive Care in Cancer · doi:10.1007/s00520-021-06448-7 · Cited by 5
Hong, J., Jeong, B.-G., Chun, J., Lee, J., & Hyun, T. H. (2021) · Journal of Food Composition and Analysis · doi:10.1016/j.jfca.2021.104088 · Cited by 5
Estimation of pulmonary artery pressure with transesophageal echocardiography
Mora, B., Roth, D., Bernardi, M. H., Base, E., & Weber, U. (2021) · Medicine · doi:10.1097/md.0000000000026988 · Cited by 5
Repp, K., Radke, D., Ittermann, T., Albers, M., Markus, M. R. P., Helena, E. T. D. S., Friedrich, N., Bülow, R., & Völzke, H. (2021) · British Journal Of Nutrition · doi:10.1017/s0007114521003123 · Cited by 6
Igwesi-Chidobe, C. N., Sorinola, I. O., & Godfrey, E. L. (2021) · Journal of Patient-Reported Outcomes · doi:10.1186/s41687-021-00367-1 · Cited by 7
Koirala, N., & McLennan, G. (2021) · Diagnostics · doi:10.3390/diagnostics11101771 · Cited by 5
Test‐retest Repeatability of the Ohio Contrast Cards
Osman, M., Njeru, S. M., Hopkins, G. R., & Brown, A. M. (2021) · Optometry and Vision Science · doi:10.1097/opx.0000000000001771 · Cited by 5
Szalai, E., & Csutak, A. (2021) · International Ophthalmology · doi:10.1007/s10792-021-02036-0 · Cited by 5
García‐Medina, J. J., Rotolo, M., Rubio-Velázquez, E., Pinazo-Duran, M. D., & del‐Río‐Vellosillo, M. (2021) · Journal of Clinical Medicine · doi:10.3390/jcm10215009 · Cited by 5
Estimating exercise Pa CO 2 in patients with heart failure with preserved ejection fraction
Balmain, B. N., Tomlinson, A. R., MacNamara, J. P., Sarma, S., Levine, B. D., Hynan, L. S., & Babb, T. G. (2021) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00474.2021 · Cited by 6
Reproducibility of an Intraoperative Pressure Sensor in Total Knee Replacement
Fary, C., McKenzie, D. P., & de Steiger, R. N. (2021) · Sensors · doi:10.3390/s21227679 · Cited by 6
Brännström, K. J., Karjalainen, S., Sahlén, B. S., Andersson, K., Åhlander, V. L., & Christensson, J. (2021) · Child Language Teaching and Therapy · doi:10.1177/02656590211050868 · Cited by 5
Louka, K., Cox, J., Tan, I., Avolio, A. P., O’Rourke, M. F., & Butlin, M. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9630063 · Cited by 5
Ylikauma, L. A., Lanning, K. M., Erkinaro, T. M., Ohtonen, P. P., Vakkala, M. A., Liisanantti, J. H., Juvonen, T. S., & Kaakinen, T. I. (2021) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2021.11.039 · Cited by 6
Accuracy of body composition measurement techniques across the age span
Rose, G. L., Farley, M. J., Ward, L. C., Slater, G., Skinner, T. L., Keating, S. E., & Schaumberg, M. A. (2022) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2021-0587 · Cited by 7
Cao, X., Xu, X., Treves, S. T., Drubach, L. A., Kwatra, N. S., Zhang, M., Fahey, F. H., Diamond, D. A., & Voss, S. D. (2022) · Pediatric Nephrology · doi:10.1007/s00467-022-05446-z · Cited by 7
Dunne, A., O’Neill, C., Warrington, G. D., Rackard, G., & Cullen, S. (2022) · Sport Sciences for Health · doi:10.1007/s11332-022-00896-2 · Cited by 6
Toms, A. P., Rifai, T., Whitehouse, C. E., & McNamara, I. (2022) · European Radiology · doi:10.1007/s00330-021-08483-8 · Cited by 5
Psychometric Evaluation of the German Version of the Social Functioning in Dementia Scale (SF-DEM)
Grothe, J., Luppa, M., Dietzel, J., Schomerus, G., Sommerlad, A., Riedel-Heller, S. G., & Röhr, S. (2022) · Journal of Alzheimer s Disease · doi:10.3233/jad-215557 · Cited by 5
Machine learning based analysis of stroke lesions on mouse tissue sections
Damigos, G., Zacharaki, E. I., Zerva, N., Pavlopoulos, A., Chatzikyrkou, K., Koumenti, A., Moustakas, K., Pantos, C. I., Mourouzis, I., & Lourbopoulos, A. (2022) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1177/0271678x221083387 · Cited by 5
Castagna, C., Krustrup, P., & Póvoas, S. C. A. (2022) · European Journal of Applied Physiology · doi:10.1007/s00421-022-04928-0 · Cited by 7
Chiu, E., Wang, Y., Huang, S., Hsueh, I., Chiang, H.-Y. A., & Hsieh, C. (2022) · Disability and Rehabilitation · doi:10.1080/09638288.2022.2060334 · Cited by 5
Rezaei, Z., Pourabbas, B., Kühne, V., Pourabbas, P., & Büscher, P. (2022) · Journal of Tropical Medicine · doi:10.1155/2022/3569704 · Cited by 5
Measuring Rectal Cancer Tumor Height: Concordance Between Clinical Examination and MRI
Navarro, S. M., Chen, S., & Farkas, L. M. (2021) · Diseases of the Colon & Rectum · doi:10.1097/dcr.0000000000002282 · Cited by 5
Calibration and Cross-validation of Accelerometry in Children and Adolescents with Cystic Fibrosis
Bianchim, M. S., McNarry, M. A., Evans, R., Thia, L. P., BARKER, A. R., Williams, C. A., Denford, S., & Mackintosh, K. A. (2022) · Measurement in Physical Education and Exercise Science · doi:10.1080/1091367x.2022.2065919 · Cited by 6
Sant’Anna, R. T., Roberts, S., Moore, L. J., Kraak, W. J., & Stokes, K. (2022) · International Journal of Sports Science & Coaching · doi:10.1177/17479541221078280 · Cited by 7
Nève, G., Bur, L., Lampert, L., Höchsmann, C., Brombach, C., Steinemann, N., & Schmidt‐Trucksäss, A. (2022) · Frontiers in Nutrition · doi:10.3389/fnut.2022.844156 · Cited by 6
Murata, S., Iwasaki, H., Oka, H., Hashizume, H., Yukawa, Y., Minamide, A., Tsutsui, S., Takami, M., Nagata, K., Taiji, R., et al. (2022) · BMC Medical Imaging · doi:10.1186/s12880-022-00792-8 · Cited by 5
Crowe, L. A., Genecand, L., Hachulla, A.-L., Noble, S., Beghetti, M., Vallée, J., & Lador, F. (2022) · Journal of Clinical Medicine · doi:10.3390/jcm11102717 · Cited by 6
Dimov, I. P., Tous, C., Li, N., Barat, M., Bomberna, T., Debbaut, C., Jin, N., Moran, G. R., Tang, A., & Soulez, G. (2022) · European Radiology · doi:10.1007/s00330-022-08890-5 · Cited by 5
Conditions for Textile Electrode Sensors to Monitor Cardiac Activity in Daily Life
Kim, J. K., Park, S., Cho, H.-S., Yang, J.-H., Lee, S.-H., & Lee, J. (2022) · Journal of Electrical Engineering and Technology · doi:10.1007/s42835-022-01156-6 · Cited by 5
A Comparative Analysis of Agile Teamwork Quality Measurement Models
da Silva, M. M., Perkusich, M., Freire, A., Albuquerque, D. W., Gorgônio, K., de Almeida, H. O., Perkusich, Â., & Guimarães, E. T. (2022) · Journal of Communications Software and Systems · doi:10.24138/jcomss-2021-0177 · Cited by 6
Gerbino, M., Parodi, S., Ballarini, M., & Paladini, D. (2022) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.26033 · Cited by 5
Inline dual‐echo T2 quantification in brain using a fast mapping reconstruction technique
Snyder, J., Seres, P., Stobbe, R., Grenier, J. G., Smyth, P. S., Blevins, G., & Wilman, A. H. (2022) · NMR in Biomedicine · doi:10.1002/nbm.4811 · Cited by 5
Reichert, J. C., Hofer, A., Matziolis, G., & Wassilew, G. I. (2022) · Journal of Clinical Medicine · doi:10.3390/jcm11164817 · Cited by 5
Validity of the peak velocity to detect physical training improvements in athymic mice
Kraemer, M. B., da Silva, K. C., Kraemer, C. D. C. F., Pereira, J. S., dos Reis, I. G. M., Priolli, D. G., & Messias, L. H. D. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2022.943498 · Cited by 5
Crook‐Rumsey, M., Musa, A. M., Iniesta, R., Drakakis, E. M., Boutelle, M. G., Shaw, C. E., & Bashford, J. (2022) · Muscle & Nerve · doi:10.1002/mus.27701 · Cited by 5
Steenhorst, J. J., Hirsch, A., van den Berg, L. E. M., Kamphuis, L. S. J., Merkus, D., Boersma, E. H., & Helbing, W. A. (2022) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12784 · Cited by 5
Bursais, A. K., Gentles, J. A., Albujulaya, N., & Stone, M. H. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2022.942954 · Cited by 6
Boccardo, L., Vizio, A. D., Galli, G., Naroo, S. A., Fratini, A., Tavazzi, S., Gurioli, M., & Zeri, F. (2022) · Journal of Optometry · doi:10.1016/j.optom.2022.08.004 · Cited by 5
Wang, L., Zhang, X., Qin, Y., Wang, F., Cui, M., Shi, Y., & Chen, Y. (2022) · The Journal of Vascular Access · doi:10.1177/11297298221118742 · Cited by 6
Heeman, F., Visser, D., Yaqub, M. M., Verfaillie, S. C. J., Timmers, T., Pijnenburg, Y. A. L., van der Flier, W. M., van Berckel, B. N. M., Boellaard, R., Lammertsma, A. A., et al. (2022) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1177/0271678x221135270 · Cited by 5
Alter, S. E., & Arroyave, J. (2022) · Metabarcoding and Metagenomics · doi:10.3897/mbmg.6.89857 · Cited by 5
Yanmaz, L. E., Okur, S., Ersöz, U., Şenocak, M. G., & Turgut, F. (2022) · Journal of the American Veterinary Medical Association · doi:10.2460/javma.22.08.0357 · Cited by 7
Telephone cognitive screening with older Aboriginal Australians: A preliminary study
Veinovic, M., Hill, T. Y., Lavrencic, L. M., Broe, G. A., Delbaere, K., Donovan, T., Draper, B., Lasschuit, D., Mann, R. L., Sullivan, K., et al. (2022) · Australian Journal on Ageing · doi:10.1111/ajag.13147 · Cited by 5
Wu, C.-Y., Huang, S., Lin, Y.-H., Hsieh, H., Chu, L. W. L., Yang, H., Chiu, S., & Peng, S. (2022) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-022-01048-w · Cited by 5
Sun, S., Shao, K., Lu, J., An, H., Shi, H., Zhou, P., & Chen, B. Y. (2022) · The Journal of Clinical Pharmacology · doi:10.1002/jcph.2176 · Cited by 5
Validation of the DYOP visual acuity test
Gantz, L., Paritzky, D., Wunch, I., Kageyama, A. H., Wolf, N., Cherny, C., & Rosenfield, M. (2022) · Journal of Optometry · doi:10.1016/j.optom.2022.09.006 · Cited by 5
Atlas-Based Segmentation in Extraction of Knee Joint Bone Structures from CT and MR
Zarychta, P. (2022) · Sensors · doi:10.3390/s22228960 · Cited by 5
Jansson, A. K., Lubans, D. R., Duncan, M. J., Smith, J. J., Bauman, A. E., Attia, J. R., & Plotnikoff, R. C. (2022) · PLoS ONE · doi:10.1371/journal.pone.0278374 · Cited by 8
Babačić, H., Galardi, S., Umer, H. M., Hellström, M., Uhrbom, L., Maturi, N., Cardinali, D., Pellegatta, S., Michienzi, A., Trevisi, G., et al. (2023) · Molecular Oncology · doi:10.1002/1878-0261.13355 · Cited by 7
Analytical evaluation and quality assessment of the ARKRAY ADAMS A1c HA-8190V for Hb A1c
Urrechaga, E. (2023) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2023.2167231 · Cited by 6
Reliability of the Coimbra Reactive Agility Soccer Test (CRAST)
Nóbrega, A., Sarmento, H., Vaz, V., Gouveia, V., Barrera, J. I., Martins, A., Santos, T., & Duarte, J. P. (2023) · Journal of Functional Morphology and Kinesiology · doi:10.3390/jfmk8010011 · Cited by 7
De, A. (2023) · Statistics in Biopharmaceutical Research · doi:10.1080/19466315.2023.2169752 · Cited by 6
Komanek, T., Rabis, M., Omer, S., Peters, J., & Frey, U. H. (2023) · BMC Anesthesiology · doi:10.1186/s12871-023-02025-z · Cited by 5
Italian translation and validation of the Contact Lens Dry Eye Questionnaire-8 (CLDEQ-8)
Zeri, F., Tavazzi, S., Naroo, S. A., Recchioni, A., Menduni, F., Ponzini, E., Chalmers, R. L., & Desiato, A. (2023) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2023.101842 · Cited by 5
Farahmand, M., Bodwell, E., D’Souza, G. A., Herbertson, L. H., & Scully, C. G. (2023) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2023.106979 · Cited by 5
Lefaucheur, J., Nguyen, J., Delmas, A., Croci, S., Bredoux, L., & Hodaj, H. (2023) · Neuromodulation Technology at the Neural Interface · doi:10.1016/j.neurom.2023.04.470 · Cited by 5
Bronchodilator response by interrupter technique to guide management of preschool wheeze
Seddon, P. C., Willson, R., Olden, C., Symes, E., Lombardi, E., & Beydon, N. (2023) · Archives of Disease in Childhood · doi:10.1136/archdischild-2022-324496 · Cited by 5
Kaestner, L., Streb, L., Hetjens, S., Buergy, D., Sihono, D. S. K., Fleckenstein, J., Kalisch, I., Eckl, M., Giordano, F. A., Lohr, F., et al. (2023) · Physics and Imaging in Radiation Oncology · doi:10.1016/j.phro.2023.100455 · Cited by 5
Coppadoro, A., Bellani, G., & Foti, G. (2023) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-023-01034-0 · Cited by 5
Mengi, A., Vallely, L. M., Laman, M., Jally, E., Kulimbao, J., Warel, S., Enman, R., Aipit, J., Low, N. N., & Riddell, M. A. (2023) · PLOS Global Public Health · doi:10.1371/journal.pgph.0001924 · Cited by 5
Min, J., & Min, K. (2023) · Sensors · doi:10.3390/s23136026 · Cited by 6
Johansson, L. M., Lingfors, H., Golsäter, M., Rolander, B., & Fransson, E. I. (2023) · BMC Sports Science Medicine and Rehabilitation · doi:10.1186/s13102-023-00690-8 · Cited by 6
Huang, C., Nihey, F., Fukushi, K., Kajitani, H., Nozaki, Y., & Nakahara, K. (2023) · IEEE Sensors Letters · doi:10.1109/lsens.2023.3297797 · Cited by 5
Kosilek, R. P., Ittermann, T., Radke, D., Schipf, S., Nauck, M. A., Friedrich, N., & Völzke, H. (2023) · Diagnostics · doi:10.3390/diagnostics13152594 · Cited by 5
Tinsley, G. M., LaValle, C., Rodriguez, C., Siedler, M. R., & Heymsfield, S. B. (2023) · European Journal of Clinical Nutrition · doi:10.1038/s41430-023-01331-6 · Cited by 5
Rubio, K., Müller, J. M., Mehta, A., Watermann, I., Olchers, T., Koch, I., Wessels, S., Schneider, M. A., Araujo-Ramos, T., Singh, I., et al. (2023) · Discover Oncology · doi:10.1007/s12672-023-00799-9 · Cited by 6
Georg, S., Genser, B., Fischer, J. E., Sachse, S., & Bock, F. D. (2023) · BMC Pediatrics · doi:10.1186/s12887-023-04334-1 · Cited by 9
Plug-and-Play Microphones for Recording Speech and Voice with Smart Devices
Noffs, G., Cobler-Lichter, M., Perera, T., Kolbe, S. C., Butzkueven, H., Boonstra, F. M. C., van der Walt, A., & Vogel, A. P. (2024) · Folia Phoniatrica et Logopaedica · doi:10.1159/000535152 · Cited by 5
Rho, G., Rienzo, F. D., Marinai, C., Giannetti, F., Arcarisi, L., Bufano, P., Zanoletti, M., Righetti, F., Vallati, C., Laurino, M., et al. (2024) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-031-49062-0_3 · Cited by 8
Beech, A. S., & Singh, D. (2024) · European Respiratory Society eBooks · doi:10.1183/2312508x.10007023 · Cited by 8
Topsakal, O., Sawyer, P., Akıncı, T. Ç., Topsakal, E., & Çelikoyar, M. M. (2024) · BioMedInformatics · doi:10.3390/biomedinformatics4010038 · Cited by 5
de Moura, A. C. R., Rocha, R. D. O., de Araújo, A. K. D. S., de Castro, S. S., Moreira, M. A., & do Nascimento, S. L. (2024) · Disability and Rehabilitation · doi:10.1080/09638288.2024.2327479 · Cited by 5
Oh, Y., Kim, D. K., Ryu, D. K., & Choi, J. W. (2024) · Journal of Anesthesia · doi:10.1007/s00540-024-03317-5 · Cited by 5
Murawa, M., Krakowiak, W., & Kabaciński, J. (2024) · Applied Sciences · doi:10.3390/app14114843 · Cited by 5
Nottin, S., Walther, G., Vinet, A., Dauzat, M., Beck, L., MESSNER-PELLENC, P., & Obert, P. (2006) · PubMed · Cited by 5
Computerized Segmentation of Organs by Means of Geodesic Active-Contour Level-Set Algorithm
Suzuki, K. (2011) · Springer eBooks · doi:10.1007/978-1-4419-8195-0_4 · Cited by 5
Strategies for Protein Separation
Salvato, F., de Carvalho, M. C. D. C. G., & Leite, A. D. L. (2012) · InTech eBooks · doi:10.5772/29363 · Cited by 10
The anatomy and function of the equine thoracolumbar Longissimus dorsi muscle
von Scheven, C. (2010) · Cited by 6
Time points for obtaining representative values of 24-hour blood pressure in chronic kidney disease
Ryu, J., Cha, R., Kim, D. K., Lee, J. H., Yoon, S. A., Ryu, D., Oh, J., Kim, S., Han, S. Y., Lee, E. Y., et al. (2015) · The Korean Journal of Internal Medicine · doi:10.3904/kjim.2015.30.5.665 · Cited by 5
Reyhan, M. L., Kim, H. J., Brown, M. S., & Ennis, D. B. (2013) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24162 · Cited by 5
Comparison of Office, Home, and Ambulatory Blood Pressure in Heart Transplant Recipients
Aquilante, C. L., Page, R. L., II, Vu, A., Roscoe, N., Wolfel, E. E., & Lindenfeld, J. A. (2014) · Journal of Cardiac Failure · doi:10.1016/j.cardfail.2014.05.005 · Cited by 5
Efeito temporal sobre a resposta da percepção subjetiva do esforço
Pedro, R. E., Oliveira, R. S., Vasconcelos, P. S. D. S., Júnior, R. P., & Milanez, V. F. (2014) · Revista Brasileira de Medicina do Esporte · doi:10.1590/1517-86922014200501302 · Cited by 5
Brazilian reference values for MPS II screening in dried blood spots — A fluorimetric assay
de Rezende, M. M., Müller, K. B., Pereira, V. G., & D’Almeida, V. (2014) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2014.06.010 · Cited by 5
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.