STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 35,901–36,000 of 47,868
Aoki, M., Harada, K., Tamura, M., Toyono, M., & Takada, G. (2004) · Pediatric Cardiology · doi:10.1007/s00246-004-0648-y · Cited by 5
Willems, H. P. J., den Heijer, M., Lindemans, J. W., Berenschot, H. W., Gerrits, W. B. J., Bos, G. M. J., & Blom, H. J. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2004.040634 · Cited by 5
Wang, Z., Chia, J. M., Ahmed, S., & Rollins, N. K. (2014) · Medical Physics · doi:10.1118/1.4893195 · Cited by 5
Atheromatous Plaques: Quantitative Analysis of the Echogenicity of Different Layers
Craiem, D. O., Chironi, G. N., Graf, S., Denarié, N., Armentano, R. L., & Simon, A. C. (2009) · Revista Española de Cardiología (English Edition) · doi:10.1016/s1885-5857(09)73264-5 · Cited by 5
Mellone, S., Tacconi, C., & Chiari, L. (2011) · Gait & Posture · doi:10.1016/j.gaitpost.2010.10.060 · Cited by 5
Homar, J., Abadal, J. M., Llompart-Pou, J. A., Pérez‐Bárcena, J., & Ibáñez, J. (2007) · Neurocirugía · doi:10.1016/s1130-1473(07)70284-1 · Cited by 5
Determination of Extracellular Fluid Volume in Healthy and Azotemic Cats
Finch, N., Heiene, R., Elliott, J., Syme, H. M., & Peters, A. M. (2014) · Journal of Veterinary Internal Medicine · doi:10.1111/jvim.12506 · Cited by 5
Eilertsen, H., & Hagve, T. (2014) · American Journal of Clinical Pathology · doi:10.1309/ajcp4v4exyffoell · Cited by 6
Thway, T. M., Wang, J., Brunner, L., Gu, W., Magana, I., Padbury, G. E., & Ma, M. (2011) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2011.09.004 · Cited by 5
Forte, P., Ogborn, M. R., & Lilley-Chan, T. (2006) · Pediatric Research · doi:10.1203/01.pdr.0000214880.15623.84 · Cited by 5
Berg, W., Bechler, R., & Laube, N. (2009) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2009.099 · Cited by 5
Yé, Y., Sauerborn, R., Séraphin, S., & Hoshen, M. B. (2007) · Annals of Tropical Medicine and Parasitology · doi:10.1179/136485907x176490 · Cited by 5
Lundqvist, K., Neovius, M., Grigorenko, A., Nordenström, J., & Rössner, S. (2008) · Radiography · doi:10.1016/j.radi.2008.02.006 · Cited by 8
Fiabilité et survie du cathéter artériel : réponse dynamique optimale
Riachy, M. A., Riachy, E., Sleilaty, G., Dabar, G., Yazigi, A. G., & Khayat, G. (2006) · Annales Françaises d Anesthésie et de Réanimation · doi:10.1016/j.annfar.2006.11.008 · Cited by 5
Urinary 17α‐hydroxyprogesterone in management of 21 ‐hydroxylase deficiency
LIM, Y. J., YONG, A. B. W., Warne, G. L., & Montalto, J. (1995) · Journal of Paediatrics and Child Health · doi:10.1111/j.1440-1754.1995.tb02913.x · Cited by 5
Hernández-Mocholí, M. A., Adsuar, J. C., Romero, C. D., Prieto, J. P., Domínguez‐Muñoz, F. J., & Olivares, P. R. (2013) · Rehabilitación · doi:10.1016/j.rh.2013.02.004 · Cited by 5
A portable device to assess underwater changes of cardio dynamic variables by impedance cardiography
Tocco, F., Crisafulli, A., Marongiu, E., Milia, R., Kalb, A., & Concu, A. (2012) · Journal of Physics Conference Series · doi:10.1088/1742-6596/407/1/012026 · Cited by 5
Analysis of five glucometers available in India
Kumar, V., Indukuri, D., & Bhat, N. (2014) · International Journal of Diabetes in Developing Countries · doi:10.1007/s13410-014-0216-9 · Cited by 6
Arias-Rivera, S., Alonso, P. C., Izquierdo, R. S., Granell, C. G., Pérez-Cejuela, J. A. M. D. L. T., Castro, M. E. O., Berlanga, M. L., Durán, T. P., Compari, F. O., & de la Cal, M. A. (2004) · Enfermería Intensiva · doi:10.1016/s1130-2399(04)78153-5 · Cited by 5
VALIDAÇÃO DE QUESTIONÁRIOS DE FREQUÊNCIA ALIMENTAR: UMA REVISÃO SISTEMÁTICA
Ataide‐Silva, T., & Vasconcelos, S. M. L. (2013) · DEMETRA Alimentação Nutrição & Saúde · doi:10.12957/demetra.2013.5892 · Cited by 6
Evaluation of two methods to calculate p50 from a single blood sample
Ekeløf, N. P., Eriksen, J., & Kancir, C. B. (2001) · Acta Anaesthesiologica Scandinavica · doi:10.1034/j.1399-6576.2001.045005550.x · Cited by 5
Should we replace the mercury in glass thermometer with the tympanic thermometer?
Lo, S., Lau, L., Law, I., & Yip, A. W. C. (2003) · Annals of the College of Surgeons Hong Kong · doi:10.1046/j.1442-2034.2003.00156.x · Cited by 5
Repeatability of sound-evoked triceps myogenic potentials
Brooke, R. E., Herbert, N. C., & Thyer, N. J. (2014) · International Journal of Audiology · doi:10.3109/14992027.2014.938780 · Cited by 6
Izquierdo, J. A., Leiva, A., Jäger, E. C., Buades, A. P., Castell, M. C. M., Fiol, A. S., & Esteva, M. (2011) · Atención Primaria · doi:10.1016/j.aprim.2011.03.008 · Cited by 7
DeCroos, F. C., Stinnett, S. S., Heydary, C. S., Burns, R. E., & Jaffe, G. J. (2013) · Translational Vision Science & Technology · doi:10.1167/tvst.2.7.7 · Cited by 6
Nieuwenhuis, L. L., de Vaate, M. B., Hehenkamp, W. J. K., Heymans, M. W., van Baal, M., Brölmann, H. A. M., & Huirne, J. A. F. (2014) · European Journal of Obstetrics & Gynecology and Reproductive Biology · doi:10.1016/j.ejogrb.2014.05.010 · Cited by 5
Corrias, M. V., Pistorio, A., Cangemi, G., Tripodi, G., Carlini, B., Scaruffi, P., Fardin, P., Garaventa, A., Pistoia, V., & Haupt, R. (2010) · Pediatric Blood & Cancer · doi:10.1002/pbc.22498 · Cited by 5
dos Santos, L. J., Balbinotti, L., Marques, A. Y. C., Alscher, S., & Vieira, S. R. R. (2009) · Revista Brasileira de Terapia Intensiva · doi:10.1590/s0103-507x2009000200003 · Cited by 8
Matar, K. M. (2014) · Journal of Chromatography B · doi:10.1016/j.jchromb.2014.05.017 · Cited by 5
Does choice of estimators influence conclusions from true metabolizable energy feeding trials?
Sherfy, M. H., Kirkpatrick, R. L., & Webb, K. E. (2005) · Journal für Ornithologie · doi:10.1007/s10336-005-0094-5 · Cited by 5
Lee, K. H., Kang, M. G., Lim, H., Kim, C. Y., & Kim, N. R. (2012) · Korean Journal of Ophthalmology · doi:10.3341/kjo.2012.26.5.369 · Cited by 5
The attitude of Greek student nurses toward euthanasia
Bakalis, N., Filippia, N., Maria, N., & Kiekkas, P. (2013) · Journal of Nursing Education and Practice · doi:10.5430/jnep.v4n1p237 · Cited by 5
Reliability of Urinary 6-sulfatoxymelatonin as a Biomarker in Breast Cancer
Barba, M., Cavalleri, A., Schünemann, H. J., Krogh, V., Evangelista, A., Secreto, G., Micheli, A., Zhou, Q., Fuhrman, B. J., Teter, B. E., et al. (2006) · The International Journal of Biological Markers · doi:10.1177/172460080602100408 · Cited by 5
Chaudhury, B., Goldgof, D. B., Hall, L., Gatenby, R. A., Gillies, R. J., & Drukteinis, J. S. (2015) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/smc.2015.378 · Cited by 5
Ahmed, I., Nuri, M. M. H., An, Z., Sm, A., & Ahmed, M. (2016) · PubMed · Cited by 5
Yoshida, C., Nakamae, H., Fletcher, L., Koga, D., Sogabe, T., Matsumura, I., Kanakura, Y., Branford, S., & Naoe, T. (2016) · SpringerPlus · doi:10.1186/s40064-016-2258-6 · Cited by 5
Dajani, H. R., Hosokawa, K., & Ando, S. (2016) · Journal of Cardiac Failure · doi:10.1016/j.cardfail.2016.05.007 · Cited by 5
Huang, J., Lu, W., Savini, G., Chen, H., Wang, C., Yu, X., Bao, F., & Wang, Q. (2016) · Journal of Ophthalmology · doi:10.1155/2016/6347236 · Cited by 5
Patient and Therapist Agreement on Performance-Rated Ability Using the de Morton Mobility Index
Haas, R., Bowles, K., O’Brien, L., & Haines, T. P. (2016) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2016.07.008 · Cited by 5
A New Gender-Specific Formula to Estimate 24-Hour Urine Protein from Protein to Creatinine Ratio
Mayayo, M., Alonso, M. M., Valdivielso, J. M., & Fernández-Giráldez, E. (2016) · The Nephron journals/Nephron journals · doi:10.1159/000447604 · Cited by 5
Amoore, J., Geake, W. B., & Scott, D. H. T. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1996.646348 · Cited by 5
Single track location Shear Wave Elasticity Imaging of the liver with reduced propagation windows
Hollender, P. J., Palmeri, M. L., & Trahey, G. E. (2016) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2016.7728826 · Cited by 5
Telles, R. W., Costa‐Silva, L., Machado, L. A. C., dos Reis, R. C. P., & Barreto, S. M. (2016) · Revista Brasileira de Reumatologia · doi:10.1016/j.rbr.2016.10.003 · Cited by 5
Human runners exhibit a least variable gait speed
Cher, P. H., Worringham, C. J., & Stewart, I. B. (2016) · Journal of Sports Sciences · doi:10.1080/02640414.2016.1262053 · Cited by 6
Measuring core temperature using the proprietary application and thermo-smartphone adapter
Darocha, T., Majkowski, J., Sanak, T., Podsiadło, P., Kosiński, S., Sałapa, K., Mazur, P. K., Ziętkiewicz, M., Gałązkowski, R., Krzych, Ł. J., et al. (2016) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-016-9968-8 · Cited by 5
Kozuma, K., Kashiwabara, K., Shinozaki, T., Kozuma, K., Oba, K., & Matsuyama, Y. (2017) · International journal of cardiac imaging · doi:10.1007/s10554-017-1068-4 · Cited by 5
Fuest, M., Mamas, N., Walter, P., Mazinani, B. A. E., Roessler, G. F., & Plange, N. (2017) · Current Eye Research · doi:10.1080/02713683.2016.1264608 · Cited by 5
Gayat, É., Imbert, N., Roujansky, A., Lemasle, L., & Fischler, M. (2017) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000001783 · Cited by 5
Hahn, I. K., Kim, J. Y., Kim, M. J., Tchah, H., & Moon, C. H. (2017) · Korean Journal of Ophthalmology · doi:10.3341/kjo.2017.31.1.44 · Cited by 5
Murayama, M., Mikami, T., Kaga, S., Okada, K., Hioka, T., Masauzi, N., Nakabachi, M., Nishino, H., Yokoyama, S., Nishida, M., et al. (2017) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2017.01.006 · Cited by 5
Market research in India: does the choice of language cause questionnaire contamination?
Messner, W. (2017) · Journal of Indian Business Research · doi:10.1108/jibr-09-2016-0100 · Cited by 6
Inability of Open-Field Autorefraction to Eliminate Accommodation in Preschoolers
Kara, C., & Petriçli, İ. S. (2017) · Journal of Pediatric Ophthalmology & Strabismus · doi:10.3928/01913913-20170329-01 · Cited by 5
Sarma, M. K., Nagarajan, R., Iqbal, Z., Macey, P. M., & Thomas, M. A. (2017) · Scientific Reports · doi:10.1038/s41598-017-03121-0 · Cited by 5
Biagi, L., Bertachi, A. H., Conget, I., Quirós, C., Giménez, M., Ampudia‐Blasco, F. J., Rossetti, P., Bondía, J., & Vehí, J. (2017) · Journal of Diabetes Science and Technology · doi:10.1177/1932296817714272 · Cited by 6
Difference in the QT Intervals between Automated and Manual Measurements
Yoshinaga, M., & Nagashima, M. (2013) · Japanese Journal of Electrocardiology · doi:10.5105/jse.32.427 · Cited by 5
Derbyshire, B., & Barkatali, B. M. (2017) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2017.06.005 · Cited by 5
Essa’a, V. J., Dimodi, H. T., Ntsama, P. M., & Medoua, G. N. (2017) · Nutrire · doi:10.1186/s41110-017-0045-y · Cited by 6
Stevens, K. N., Asher, L., Griffin, K., Friel, M., O’Connell, N. E., & Collins, L. (2017) · Applied Animal Behaviour Science · doi:10.1016/j.applanim.2017.08.002 · Cited by 7
Freeman, V. L., Boylan, E. E., Pugach, O., McLafferty, S., Tossas, K. Y., Watson, K. S., & Winn, R. A. (2017) · Cancer Causes & Control · doi:10.1007/s10552-017-0941-8 · Cited by 5
New Objective Refraction Metric Based on Sphere Fitting to the Wavefront
Jaskulski, M., Martínez-Finkelshtein, A., & López‐Gil, N. (2017) · Journal of Ophthalmology · doi:10.1155/2017/1909348 · Cited by 7
Baumstark, A., Jendrike, N. R. M., Pleus, S., Liebing, C., Haug, C., & Freckmann, G. (2017) · Journal of Diabetes Science and Technology · doi:10.1177/1932296817730380 · Cited by 5
Comparison between resting metabolic rate and indirect calorimetry in postmenopausal women
Carteri, R. B., Feldmann, M., Gross, J. S., Krüger, R. L., LOPES, A. L., & Reischak-Oliveira, Á. (2017) · Revista de Nutrição · doi:10.1590/1678-98652017000500004 · Cited by 7
Estimation of Arm Adipose Tissue Quotient Using Segmental Bioimpedance Spectroscopy
Buendía, R., Essex, T., Kilbreath, S. L., Czerniec, S. A., Dylke, E. S., & Ward, L. C. (2017) · Lymphatic Research and Biology · doi:10.1089/lrb.2017.0050 · Cited by 5
Vieira, M. S., Henningsson, M., Dedieu, N., Vassiliou, V. S., Bell, A., Mathur, S., Pushparajah, K., Figueroa, C. A., Hussain, T., Botnar, R. M., et al. (2018) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2017.12.023 · Cited by 6
A boka-kar index oszcillometriás elven működő meghatározásának helye a klinikai gyakorlatban
Járai, Z., Kolossváry, E., Szabó, I., Kiss, I., Farsang, C., & Farkas, K. (2018) · Orvosi Hetilap · doi:10.1556/650.2018.30957 · Cited by 5
Inter‐ and intra‐rater reliability and agreement in determining subcutaneous tumour margins in dogs
Ranganathan, B., Milovancev, M., Leeper, H. J., Townsend, K. L., Bracha, S., & Curran, K. M. (2018) · Veterinary and Comparative Oncology · doi:10.1111/vco.12394 · Cited by 5
Sato, H., Kusayanagi, K., Kondo, Y., Kamide, N., Shiba, Y., & Takashima, A. (2018) · Geriatrics and gerontology international/Geriatrics & gerontology international · doi:10.1111/ggi.13299 · Cited by 5
Krishna, B. V., Das, S. K., & Sen, S. (2018) · Indian Pediatrics · doi:10.1007/s13312-018-1271-y · Cited by 5
Verkhovsky, A., Smit, M., Levin, A. I., & Coetzee, J. F. (2018) · Southern African Journal of Anaesthesia and Analgesia · doi:10.1080/22201181.2018.1461323 · Cited by 5
Takigawa, R., Inayama, T., Yamada, K., Muraoka, Y., & Ohkawara, K. (2018) · The Journal of Physical Fitness and Sports Medicine · doi:10.7600/jpfsm.7.193 · Cited by 5
Postload Glycated Albumin as an Alternate Measure for Diabetes Screening in a Chinese Population
Su, H., Tang, J., Ma, X., He, X., Ying, L., Wang, Y., Bao, Y., & Zhou, J. (2018) · Journal of Diabetes Research · doi:10.1155/2018/7932528 · Cited by 5
Diagnostic performance of hepatitis E virus antigen assay in hepatitis E virus acute infection.
Lapa, D., Brega, C., Mammone, A., Zaccarelli, M., Capobianchi, M. R., & Garbuglia, A. R. (2016) · PubMed · Cited by 5
Panday, S., Kathard, H., Pillay, M., & Wilson, W. J. (2018) · South African Journal of Communication Disorders · doi:10.4102/sajcd.v65i1.556 · Cited by 5
Placental tissue metabolome analysis by GC-MS: Oven-drying is a viable sample preparation method
Troisi, J., Symes, S. J. K., Adair, D. C., Colucci, A., Prisco, S. E., Aquino, C. I., Vivone, I., Guida, M., & Richards, S. M. (2018) · Preparative Biochemistry & Biotechnology · doi:10.1080/10826068.2018.1466151 · Cited by 5
Rousseau, G., Asmolov, R., Auvet, A., Grammatico‐Guillon, L., & Guillon, A. (2018) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2017-1132 · Cited by 6
Accuracy of three-dimensional cephalograms generated using a biplanar imaging system
Park, H.-Y., Lee, J.-S., Cho, J., Hwang, H., & Lee, K. C. (2018) · The Korean Journal of Orthodontics · doi:10.4041/kjod.2018.48.5.292 · Cited by 5
Costela, F. M., Saunders, D. R., Kajtezovic, S., Rose, D. J., & Woods, R. L. (2018) · Translational Vision Science & Technology · doi:10.1167/tvst.7.4.13 · Cited by 5
Nyström, C. D., Söderström, E., Henriksson, P., Henriksson, H., Poortvliet, E., & Löf, M. (2018) · British Journal Of Nutrition · doi:10.1017/s0007114518002064 · Cited by 5
Predicting Lung Function Following Lobectomy: A New Method to Adjust for Inherent Selection Bias
Ontiveros, N., Eapen-John, D., Osorio, N., Song, J., Li, L., Sheshadri, A., Tiang, X., Ghosh, N., Vaporciyan, A. A., Correa, A. M., et al. (2018) · Respiration · doi:10.1159/000490258 · Cited by 5
Al-Hadabi, B., & Sassi, R. H. (2018) · Science & Sports · doi:10.1016/j.scispo.2018.04.013 · Cited by 7
Aguilera, L. G., Gallart, L., Álvarez, J. C., Vallés, J., & Gea, J. (2018) · Respiratory Research · doi:10.1186/s12931-018-0897-6 · Cited by 5
Match analysis of wheelchair padel players of different functional level
Sanz, D. N., Ramon-Llin, J. A., & Veiga, S. (2018) · Journal of Human Sport and Exercise · doi:10.14198/jhse.2018.134.18 · Cited by 5
Midorikawa, T., Hikihara, Y., Ohta, M., Ando, T., Torii, S., Sakamoto, S., & Tanaka, S. (2018) · European Journal of Clinical Nutrition · doi:10.1038/s41430-018-0344-2 · Cited by 6
The missing segment of the autopod 1st ray: new insights from a morphometric study of the human hand
Pazzaglia, U. E., Sibilia, V., Casati, L., Salvi, A. G., Minini, A., & Reguzzoni, M. (2018) · Journal of Anatomy · doi:10.1111/joa.12883 · Cited by 6
The reliability of remembered pre-operative patient-rated wrist and hand evaluation (PRWHE) scores
Finsen, V., Hillesund, S., & Fromreide, I. (2018) · Orthopedic Reviews · doi:10.4081/or.2018.7682 · Cited by 5
Sorrell, L., Mcardle, N., Becque, T., Payne, H., Stuart, B. L., Turner, S., & Wyatt, J. C. (2018) · BMJ Open · doi:10.1136/bmjopen-2018-022547 · Cited by 8
Methods for assessment of Vitamin D
Carter, G. D., & Card, D. J. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-813050-6.00003-6 · Cited by 5
Machine Learning Applied to GRBAS Voice Quality Assessment
Xie, Z., Gadepalli, C., Jalalinajafabadi, F., Cheetham, B. M. G., & Homer, J. J. (2018) · Advances in Science Technology and Engineering Systems Journal · doi:10.25046/aj030641 · Cited by 5
Latasa, I., Córdova, A., Quintana‐Ortí, G., Lavilla-Oíz, A., Navallas, J., & Rodríguez-Falces, J. (2019) · Applied Sciences · doi:10.3390/app9030589 · Cited by 6
Test-retest reliability of the ASES-p shoulder scale
Vrotsou, K., Cuéllar, R., Silió, F., Garay, D., Busto, G., & Escobar, A. (2019) · Musculoskeletal Science and Practice · doi:10.1016/j.msksp.2019.02.004 · Cited by 5
Glencross, D. K., & Coetzee, L. M. (2019) · Cytometry Part B Clinical Cytometry · doi:10.1002/cyto.b.21772 · Cited by 5
Inter-day reliability of the Upper Body Test for shoulder and pelvic girdle stability in adults
Fontes, A. D. S., Santos, M. S., de Almeida, M. B., Marin, P. J., da Silva, D. R. P., & Silva‐Grigoletto, M. E. D. (2019) · Brazilian Journal of Physical Therapy · doi:10.1016/j.bjpt.2019.02.009 · Cited by 7
Shoop-Worrall, S. J. W., Hyrich, K. L., Verstappen, S. M. M., Sergeant, J. C., Baildam, E. M., Chieng, A., Davidson, J. E., Foster, H., Ioannou, Y., McErlane, F., et al. (2019) · Arthritis Care & Research · doi:10.1002/acr.23877 · Cited by 5
Arterio-VENouS Intra Subject agreement for blood gases within intensive care: The AVENSIS study
Nanjayya, V. B., McCracken, P., Vallance, S., Jasmin Board, Kelly, P. J., Schneider, H. G., Pilcher, D. V., & Garner, D. J. (2019) · Journal of the Intensive Care Society · doi:10.1177/1751143719840259 · Cited by 6
Yue, D. (2019) · Global Journal of Obesity Diabetes and Metabolic Syndrome · doi:10.17352/2455-8583.000036 · Cited by 5
Raj, R., Selvakumar, J., & Maik, V. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2928643 · Cited by 5
Montoye, A. H. K., Clevenger, K. A., Mackintosh, K. A., McNarry, M. A., & Pfeiffer, K. A. (2019) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2018-0011 · Cited by 5
Hepatitis C Diagnostics Technology Landscape
Ajose, O., Cherise, S., & Timmermans, K. (2019) · Cited by 5
Point-of-care blood analysis of hypotensive patients in the emergency department
Shin, H., Lee, I., Kim, C., & Choi, H. J. (2019) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2019.158363 · Cited by 5
Comparison of Different Methods of Urinary Protein Excretion Measurement: Is the King Really Dead?
Rydzewska–Rosołowska, A., Kakareko, K., Naumnik, B., & Hryszko, T. (2019) · Kidney & Blood Pressure Research · doi:10.1159/000501884 · Cited by 5
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.