STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 38,801–38,900 of 47,868
Characterization and Comparison of the 10-2 SITA-Standard and Fast Algorithms
Barkana, Y., Bakshi, E., Goldich, Y., Morad, Y., Kaplan, A., Avni, I., & Zadok, D. (2012) · The Scientific World JOURNAL · doi:10.1100/2012/821802 · Cited by 3
Lee, C. G., Park, J. W., Moon, J. S., Kim, N. S., & Kim, K. H. (2011) · Journal of the Korean Society of Hypertension · doi:10.5646/jksh.2011.17.3.114 · Cited by 3
Li, Z., Feng, Z., Yan, C., & Yan, R. (2010) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.20422 · Cited by 3
Statistics in medicine: Citations of papers in the first ten years
Campbell, M. J., & Julious, S. A. (1994) · Statistics in Medicine · doi:10.1002/sim.4780130103 · Cited by 3
Flat Panel Volume Computed Tomography of the Coronary Arteries
Knollmann, F. D., Wieltsch, A., Peters, S., Mahlke, A., Niederberger, S., & Kertesz, T. (2009) · Academic Radiology · doi:10.1016/j.acra.2009.05.015 · Cited by 3
The feasibility for dicrotic augmentation index to replace tidal augmentation index
Su, Y., Zhang, Y., Jin, Y., Yao, Y., Zhang, R., Jiang, Y., & Xu, L. (2014) · IEEE International Conference on Information and Automation (ICIA) · doi:10.1109/icinfa.2014.6932787 · Cited by 3
Baulcomb, S., & Watson, R. A. (2003) · Clinical Effectiveness in Nursing · doi:10.1016/s1361-9004(03)00095-5 · Cited by 3
Coronary risk area measurement by intracardiac echocardiography and ultrasound contrast
Bissing, J. W., Ryan, A. J., & Kerber, R. E. (2001) · Journal of the American Society of Echocardiography · doi:10.1067/mje.2001.113160 · Cited by 3
Bitarafan, A., & Rajabi, H. (2008) · Annals of Nuclear Medicine · doi:10.1007/s12149-008-0161-0 · Cited by 3
Automatic polyp detection and measurement with computed tomographic colonography: A phantom study
Virmani, S., Lev-Toaff, A., & Ciancibello, L. M. (2009) · Biomedical Imaging and Intervention Journal · doi:10.2349/biij.5.3.e15 · Cited by 3
BHAMBHANI, Y. N., Kennedy, M. D., & Maikala, R. V. (2009) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2009.10.004 · Cited by 6
DeVoe, D. E. (2004) · Perceptual and Motor Skills · doi:10.2466/pms.99.2.545-546 · Cited by 3
de Araújo, O. R., Diegues, A. R., da Silva, D. C. B., Albertoni, A. D. C. S., Louzada, M. E. R., Cabral, E. A. F., Arkader, R., & Afonso, M. R. (2007) · Revista Brasileira de Terapia Intensiva · doi:10.1590/s0103-507x2007000300009 · Cited by 3
Intégration de connaissances et modélisation en imagerie médicale
Clarysse, P., Frouin, F., Garreau, M., Lalande, A., Rousseau, J., Sarrut, D., & Vasseur, C. P. A. (2004) · ITBM-RBM · doi:10.1016/j.rbmret.2004.07.002 · Cited by 3
Verberne, H. J., Fleury, E., Righetti, A., & Somsen, G. A. (2006) · Nuclear Medicine Communications · doi:10.1097/mnm.0b013e328013dc23 · Cited by 3
Rodrigues, M. N., Vanfraechem, J. H.-P., & Farinatti, P. (2007) · Arquivos Brasileiros de Cardiologia · doi:10.1590/s0066-782x2007000100013 · Cited by 3
Voon, W., Huang, C., Lin, T., Chu, C., Chen, H.-H., & Sheu, S. (2002) · Journal of the American Society of Echocardiography · doi:10.1067/mje.2002.126168 · Cited by 3
Measurement of oxygen uptake: Validation of a “mask-free” method
Corazza, I., Fabbiani, L., & Zannoli, R. (2007) · Physica Medica · doi:10.1016/j.ejmp.2007.02.002 · Cited by 3
The Evaluation of Wearable Cuff-less Blood Pressure Measuring Devices
Yan, I. R. F., & Zhang, Y. (2007) · IEEE International Conference on Information Technology and Applications in Biomedicine · doi:10.1109/itab.2007.4407417 · Cited by 3
Intérêt de l’auto-réfractomètre et de l’orbscan pour la mesure du diamètre pupillaire
Allouch, C., Touzeau, O., Kopito, R., Borderie, V. M., & Laroche, L. (2006) · Journal Français d Ophtalmologie · doi:10.1016/s0181-5512(06)77695-1 · Cited by 3
Enzymatic assay for total plasma Cys
Han, Q., & Hoffman, R. M. (2008) · Nature Protocols · doi:10.1038/nprot.2008.178 · Cited by 3
Staal, E. M., Baan, J., Jukema, J. W., van der Wall, E. E., & Paul Steendijk, A. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/2/013 · Cited by 3
The repeatability of Stewart’s parameters and anion gap in a cohort of critically ill adult patients
Mallat, J., Barrailler, S., Lemyze, M., Benzidi, Y., Pepy, F., Gasan, G., Tronchon, L., & Thévenin, D. (2012) · Intensive Care Medicine · doi:10.1007/s00134-012-2679-9 · Cited by 3
Measurements of the Periocular Facial Area with Web-Based Software
González, F., Castro, A. F., Schneider, K., & Lozano, M. (2005) · Journal of Telemedicine and Telecare · doi:10.1177/1357633x0501100705 · Cited by 3
Bonnemains, L., Mandry, D., Menini, A., Stos, B., Felblinger, J., Marie, P., & Vuissoz, P. (2013) · European Radiology · doi:10.1007/s00330-013-2851-9 · Cited by 3
Baglioni, S., Cassinelli, C., Bongini, G., Cenni, I., Graziani, N., Landini, M., Tanturli, G., Brabec, M., & Bavazzano, P. (2006) · International Archives of Occupational and Environmental Health · doi:10.1007/s00420-006-0122-7 · Cited by 3
Speed of Blood Withdrawal and Accurate Measurement of Oxygen Content in Mixed Venous Blood
Jaschke, K., Brown, D., Clark, A., Doull, S., English, A., Hoover, N. E., Jones, P., Klamm, D., Odom, C., Primrose, B., et al. (2014) · American Journal of Critical Care · doi:10.4037/ajcc2014309 · Cited by 3
Quigley, M. G., Patel, V. R., Dubé, P., Wittich, W., & Harasymowycz, P. J. (2008) · Journal of Glaucoma · doi:10.1097/ijg.0b013e31816224ec · Cited by 3
Validity of real-time measures of stuttering frequency
O’Brian, S., Jones, M., Lincoln, M., Harrison, E., Packman, A., Menzies, R. G., & Onslow, M. (2013) · Speech Language and Hearing · doi:10.1179/2050571x13z.00000000015 · Cited by 3
Previtali, M., Cannizzaro, G., Lanzarini, L. F., Calsamiglia, G., Poli, A., & Fetiveau, R. (1999) · International journal of cardiac imaging · doi:10.1023/a:1006169601499 · Cited by 3
Eppenga, W. L., van Luin, M., Richter, C., Derijks, H. J., Smet, P. A. G. M. D., & Wensing, M. (2013) · Journal of Nephrology · doi:10.1007/s40620-013-0012-5 · Cited by 4
Çıkırıkçıoğlu, M., Cikirikcioglu, Y. B., Khabiri, E., Djebaili, M. K., Kalangos, A., & Walpoth, B. H. (2005) · The Heart Surgery Forum · doi:10.1532/hsf98.20051031 · Cited by 3
Changes in height and inclination of the articular eminence during the growth period
Choi, D., Jang, I., & Cha, B. (2010) · The Korean Journal of Orthodontics · doi:10.4041/kjod.2010.40.6.411 · Cited by 3
Duarte, P. C., Souza, R. F., de Almeida, R. M., Balsamão, G. M., Ferraz, G. D. C., & Neto, A. R. T. (2014) · Comparative Clinical Pathology · doi:10.1007/s00580-014-1900-3 · Cited by 3
Lin, H.-S., Lu, H., Chen, Y., Lu, T., & Huang, Y.-D. (2015) · Journal of Dental Sciences · doi:10.1016/j.jds.2014.08.003 · Cited by 3
Abacı, A., Oğuzhan, A., Ünal, Ş., Kıranatlı, B., Eryol, N. K., Başar, E., Ergin, A., & Çetin, S. (2002) · Cardiology · doi:10.1159/000064675 · Cited by 3
Predicting 30-minute postdialysis blood urea concentrations using the stop dialysate flow method
Traynor, J. P., Geddes, C., Ferguson, C., & MACTIER, R. A. (2002) · American Journal of Kidney Diseases · doi:10.1053/ajkd.2002.30550 · Cited by 3
Reproducibilidad de los análisis de proteína C reactiva
Llorca, J., Quirós, M. G., Sampedro, I., García‐Unzueta, M. T., & de Berrazueta, J. R. (2002) · Revista Española de Cardiología · doi:10.1016/s0300-8932(02)76764-x · Cited by 3
Spirometer‐dependence of vital capacity in ALS: Validation of a portable device in 52 patients
Couratier, P., Vincent, F., Torny, F., Lacoste, M., Melloni, B., Lemaire, F., & Antonini, M.-T. (2005) · Amyotrophic Lateral Sclerosis · doi:10.1080/14660820510043244 · Cited by 3
Vergara, F. V., Bustos, E. D., Lydia Lera, M., Vásquez, L., Anziani, A., & Argote, R. B. (2014) · Nutrition · doi:10.1016/j.nut.2013.09.002 · Cited by 3
Matrix-dependent bias in total thyroxine measurement on the Beckman Access
Dietzen, D. J., Queen, S. F., & Solomon, S. S. (2002) · Clinica Chimica Acta · doi:10.1016/s0009-8981(01)00723-9 · Cited by 3
Timed Response to Inhaled Nitric Oxide in Pulmonary Hypertension
Hunt, J. M., Risbano, M. G., Messenger, J. C., Carroll, J. D., Badesch, D. B., Lowes, B. D., Casserly, I. P., Kay, J., & Bull, T. M. (2014) · Pulmonary Circulation · doi:10.1086/674880 · Cited by 4
Miguel, M. M., & Vicente, R. H. (2002) · Hipertensión y Riesgo Vascular · doi:10.1016/s1889-1837(02)71258-0 · Cited by 3
Hu, Z., Follmann, D. A., Qin, J., Dewar, R. L., & Sangweni, P. (2008) · Statistics in Medicine · doi:10.1002/sim.3298 · Cited by 3
Reliability and repeatability of the shuttle walk test in patients with chronic low back pain
Armstrong, M., McDonough, S., & Baxter, D. G. (2005) · International Journal of Therapy and Rehabilitation · doi:10.12968/ijtr.2005.12.10.24531 · Cited by 3
Measurement of cystatin C in capillary blood samples in pediatric patients
van Deutekom, A. W., Zur, B., van Wijk, J. A. E., Bouman, A. A., & Bökenkamp, A. (2009) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2009.09.021 · Cited by 3
Wall Motion Velocities of Abdominal Aorta Measured by Tissue Doppler Imaging in Normal Children
Yasuoka, K., & Harada, K. (2005) · Pediatric Cardiology · doi:10.1007/s00246-004-0476-0 · Cited by 3
Segaren, N., Abdul-Jabar, H. B., & Hashemi-Nejad, A. (2014) · The Bone & Joint Journal · doi:10.1302/0301-620x.96b8.33322 · Cited by 3
Smith, S. J., Samani, N. J., Sammons, E. L., Rathbone, W. E., Potter, J. F., Bentley, S., & Panerai, R. B. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e3282f06e9c · Cited by 3
Portable maximum respiratory pressure measurement—A comparison with laboratory techniques
Carroll, N., Clague, J. E., Pollard, M., Horan, M. A., Edwards, R. H. T., & Calverley, P. M. A. (1992) · Journal of Medical Engineering & Technology · doi:10.3109/03091909209021965 · Cited by 3
Performance of a tonometer for arterial pressure measurement during anesthesia in the elderly
Harasawa, K., Yamane, M., Morimoto, Y., & Kemmotsu, O. (2004) · Journal of Anesthesia · doi:10.1007/s00540-004-0261-5 · Cited by 3
García, G. C., Secchi, J. D., & Arcuri, C. R. (2014) · Revista Andaluza de Medicina del Deporte · doi:10.1016/s1888-7546(14)70061-9 · Cited by 3
Resting metabolic rate of Vietnamese adolescents
Nhung, B. T., Khan, N. C., Hop, L. T., Lâm, N. T., Khanh, N. L. B., Lien, D. T. K., Nakamori, M., HIEN, V. T. T., Kassu, A., & Yamamoto, S. (2007) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1602629 · Cited by 4
McGrady, M., Thanyasiri, P., Bailey, B. P., Celermajer, D. S., & Adams, M. R. (2008) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.21375 · Cited by 3
Sloth, E., Pedersen, E. M., Egeblad, H., Hasenkam, J. M., & Juhl, B. (1997) · Cardiovascular Research · doi:10.1016/s0008-6363(97)00080-1 · Cited by 3
Confiabilidade do Perfil de Saúde de Nottingham após acidente vascular encefálico
Cabral, D. L., Damascena, C. G., Teixeira‐Salmela, L. F., & Laurentino, G. E. C. (2012) · Ciência & Saúde Coletiva · doi:10.1590/s1413-81232012000500025 · Cited by 11
Gloi, A. M., McCourt, S., Zuge, C., Goettler, A. M., Schlise, S., & Cooley, G. (2008) · Medical dosimetry · doi:10.1016/j.meddos.2008.01.001 · Cited by 3
Repeatability of Static Posturography on the Follow-up of Vestibular Rehabilitation
Jáuregui‐Renaud, K., Cruz-Gómez, N. S., & Villanueva-Padrón, L. A. (2013) · Archives of Medical Research · doi:10.1016/j.arcmed.2012.12.008 · Cited by 3
Haskova, J. E., Palmer, G., & Jones, S. P. (2008) · Journal of Orthodontics · doi:10.1179/146531207225022527 · Cited by 3
Monitoring of tobramycin levels in patients with cystic fibrosis by finger-prick sampling: Figure 1–
Jones, A. M., Beisty, J., McKenna, D., Clough, D., Webb, A. K., Morris, J., & Keevil, B. G. (2012) · European Respiratory Journal · doi:10.1183/09031936.00176611 · Cited by 3
Pallett, E. J., Rentowl, P., & Hanning, C. D. (2009) · Journal of Pain and Symptom Management · doi:10.1016/j.jpainsymman.2008.11.015 · Cited by 3
Observer variation in vascular CT measurements of the abdominal aorta
England, A., Butterfield, J. S., & Ashleigh, R. (2007) · Radiography · doi:10.1016/j.radi.2007.10.002 · Cited by 3
Jokubkiene, L., Sladkevicius, P., & Valentin, L. (2007) · Obstetrical & Gynecological Survey · doi:10.1097/01.ogx.0000261651.84161.92 · Cited by 3
Groth, M., Bannas, P., Regier, M., Buhk, J., Müllerleile, K., Adam, G., & Henes, F. O. (2012) · European Radiology · doi:10.1007/s00330-012-2752-3 · Cited by 3
The Reliability of the Constant–Murley Shoulder Scoring System
Yasin, M. N., Naqui, S. Z., & Muir, L. (2010) · Shoulder & Elbow · doi:10.1111/j.1758-5740.2010.00082.x · Cited by 3
Coronary artery calcium quantification with non-ECG-gated low-dose CT of the chest
Bastarrika, G., Alonso, A., Saiz-Mendiguren, R., Arias, J., & Cosín, O. (2010) · Radiología (English Edition) · doi:10.1016/s2173-5107(10)70003-3 · Cited by 3
Kisanuki, A., Yuasa, T., Kuwahara, E., Takasaki, K., Yoshifuku, S., Otsuji, Y., Minagoe, S., & Tei, C. (2004) · Japanese Heart Journal · doi:10.1536/jhj.45.461 · Cited by 3
Mosahebi, N., & Ricketts, D. N. J. (2002) · Community Dentistry And Oral Epidemiology · doi:10.1034/j.1600-0528.2002.300301.x · Cited by 3
Single-beat determination of global longitudinal speckle strain in patients with atrial fibrillation
Yamaguchi, K., Yoshitomi, H., Ito, S., Adachi, T., Takahashi, N., & Tanabe, K. (2012) · Journal of Echocardiography · doi:10.1007/s12574-012-0135-z · Cited by 3
Urine calcium and urine sodium concentrations are not related, after adjustment for urine magnesium
Stein, Flicker, Scherer, Mead, Walton, Chick, Carlantonio, D., Zajac, & Wark (2000) · Clinical Endocrinology · doi:10.1046/j.1365-2265.2000.01066.x · Cited by 3
MRI of Right Atrial Function after Catheter Ablation of Atrial Flutter
Özgün, M., Kirchhof, P. F., Bunck, A. C., Heindel, W. L., Eckardt, L., & Maintz, D. C. (2010) · Academic Radiology · doi:10.1016/j.acra.2010.03.015 · Cited by 4
Ganter, C. C., Buser, C., Hænggi, M., Mattes, H., Takala, J. A., & Jakob, S. M. (2009) · Shock · doi:10.1097/shk.0b013e318194c73a · Cited by 3
Stahmann, F., Gauly, M., Holtz, W., & von Borstel, U. K. (2013) · Journal of Dairy Science · doi:10.3168/jds.2013-6734 · Cited by 3
Predição da massa corporal magra de adultos brasileiros através da área muscular do braço
Kanope, T., Nogueira, F. D. S., & Pompeu, F. A. M. S. (2014) · Revista Brasileira de Medicina do Esporte · doi:10.1590/1517-86922014200301839 · Cited by 4
Lacoste, C., Granizo, J. J., & Gómez‐Barrena, E. (2007) · The Knee · doi:10.1016/j.knee.2007.04.009 · Cited by 5
Zheng, J., Hu, S., Xin, S., & Crabtree, V. (2008) · Journal of Medical Engineering & Technology · doi:10.1080/03091900701453990 · Cited by 3
Katayama, M., Sasaki, A., Takayasu, M., SHIMAMURA, S., UZUKA, Y., Murayama, I., Satoh, H., & Furuhama, K. (2013) · Journal of Feline Medicine and Surgery · doi:10.1177/1098612x13492165 · Cited by 3
Proposition d’une nouvelle structure de référence mandibulaire
Curien, R., Marchal, F., & Dutour, O. (2007) · Revue d Orthopédie Dento-Faciale · doi:10.1051/odf:20074120141 · Cited by 3
Hill, K. D., Janssen, D., Ohmstede, D. P., & Doyle, T. P. (2009) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.22084 · Cited by 3
Evaluation of calcium loss after transcatheter aortic valve implantation
Nguyen‐Kim, T. D. L., Sahin, A., Sündermann, S., Winklehner, A., Grünenfelder, J., Emmert, M. Y., Maier, W., Altwegg, L., Frauenfelder, T., Falk, V., et al. (2013) · Interactive Cardiovascular and Thoracic Surgery · doi:10.1093/icvts/ivt432 · Cited by 3
Haematoxylin and eosin staining in the diagnosis of Hodgkin's disease in Uganda
Tumwine, L. K., Wabinga, H. R., & Odida, M. (2004) · East African Medical Journal · doi:10.4314/eamj.v80i3.8679 · Cited by 3
Wheeler, S., & Twist, C. (2010) · European Physical Education Review · doi:10.1177/1356336x10372698 · Cited by 3
Screening for type 2 diabetes in primary care using a stepwise protocol: The Diabscreen study
Woolthuis, E. P. K., de Grauw, W. J. C., van Gerwen, W. H. E. M., van den Hoogen, H. J. M., van de Lisdonk, E. H., Metsemakers, J. F. M., & van Weel, C. (2007) · Primary care diabetes · doi:10.1016/j.pcd.2007.09.002 · Cited by 3
Muecke, S., Bersten, A. D., & Plummer, J. (2009) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-009-9215-7 · Cited by 3
Golding, P. H. (2014) · SpringerPlus · doi:10.1186/2193-1801-3-441 · Cited by 3
Can the Tono-Pen replace the Schi tz tonometer in general practice?
Christoffersen, K. H. T. (1999) · Scandinavian Journal of Primary Health Care · doi:10.1080/028134398750003025 · Cited by 3
Williams, J. L., Shusterman, V., & Saba, S. (2006) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2006.00115.x · Cited by 3
Routine axillary temperature monitoring in neonates cared under radiant warmer — is it necessary?
George, G., & Mishra, S. (2009) · The Indian Journal of Pediatrics · doi:10.1007/s12098-009-0234-7 · Cited by 3
Quantitative Assessment of Pulmonary Shunt and Ventilation-Perfusion Mismatch without a Blood Sample
Smith, B. W., Rees, S. E., Karbing, D. S., Kjærgaard, S., & Andreassen, S. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353276 · Cited by 3
Permissible performance limits of regression analyses in method comparisons
Haeckel, R., Wosniok, W., & Shareef, N. A. (2011) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2011.668 · Cited by 3
Sievers, B., Jacobi, L., Sommer, P., Speiser, U., Schoen, S., & Strasser, R. H. (2011) · Acta Radiologica · doi:10.1258/ar.2011.100492 · Cited by 3
Validity of the Step Test for Exercise Prescription: No Extension to a Larger Age Range
Vidoni, E. D., Mattlage, A. E., Mahnken, J. D., Burns, J. M., McDonough, J. A., & Billinger, S. A. (2013) · Journal of Aging and Physical Activity · doi:10.1123/japa.21.4.444 · Cited by 4
Cardiac Power Output during Dobutamine Stress Test in Horses
Sandersen, C., Entee, K. M., Deleuze, S. C., Detilleux, J., & Amory, H. (2009) · Journal of Equine Veterinary Science · doi:10.1016/j.jevs.2009.02.005 · Cited by 3
Saporito, S., Herold, I. H. F., Houthuizen, P., van den Bosch, H. C. M., Korsten, H. H. M., van Assen, H. C., & Mischi, M. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/13/5225 · Cited by 3
Pressure Indices in Peripheral Arterial Disease Assessed by Infrared Photosensors
Emler, C., Jacomella, V., Rufibach, K., Thalhammer, C., Amann-Vesti, B. R., & Husmann, M. J. W. (2012) · Angiology · doi:10.1177/0003319712448248 · Cited by 3
Automatic Assessment of Cardiac Artery Disease by Using DCAD Module
Khalilzad-Sharghi, V., Talebpour, A., Kamali‐Asl, A., & Hendijani, N. (2008) · International Symposium on Symbolic and Numeric Algorithms for Scientific Computing (SYNASC) · doi:10.1109/synasc.2008.57 · Cited by 3
(2011) · Scientific Research and Essays · doi:10.5897/sre11.041 · Cited by 3
Transthoracic electrical bioimpedance: A means of filling the void?
Thom, O., & Taylor, D. M. (2005) · Emergency Medicine Australasia · doi:10.1111/j.1742-6723.2005.00731.x · Cited by 3
Fattorini, A., Pattarini, E., Viganò, S., Crippa, L., & D’Angelo, A. (2012) · Thrombosis Research · doi:10.1016/j.thromres.2012.05.015 · Cited by 3
Armaganidis, A., Diplas, D., Floros, I., & Roussos, C. (2008) · Interactive Cardiovascular and Thoracic Surgery · doi:10.1510/icvts.2008.182261 · Cited by 3
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).