STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 39,901–40,000 of 47,868
Examination of Resistance Settings Based on Body Weight for the 3-Minute All-Out Critical Power Test
Schulte, M. J., Clasey, J. L., Fleenor, B. S., & Bergstrom, H. C. (2018) · International journal of exercise science · doi:10.70252/duli6564 · Cited by 2
Huhle, R., Siegert, J., Wonka, F., Schindler, C., de Abreu, M. G., Koch, T., Morgenstern, U., & Theilen, H. (2016) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt-2015-0001 · Cited by 2
The accuracy of retrospectively measured range of motion in knee arthroplasty.
Babazadeh, S., Dowsey, M. M., Stone, J. D., & Choong, P. (2012) · PubMed · Cited by 2
Myocardial Blood Flow Measurement
Schindler, T. H., Valenta, I., & Schelbert, H. R. (2010) · Elsevier eBooks · doi:10.1016/b978-0-323-05796-7.00065-5 · Cited by 3
THE MICROSPHERE METHOD FOR INVESTIGATING BONE BLOOD FLOW
Anetzberger, H., & Birkenmaier, C. (2016) · WORLD SCIENTIFIC eBooks · doi:10.1142/9789814713764_0003 · Cited by 2
Parametric Methods for Dynamic 11C-Phenytoin PET Studies
Mansor, S., Yaqub, M. M., Boellaard, R., Froklage, F. E., de Vries, A., Bakker, E. D. M., Voskuyl, R. A., Eriksson, J., Schwarte, L. A., Verbeek, J., et al. (2016) · Journal of Nuclear Medicine · doi:10.2967/jnumed.116.178707 · Cited by 2
Felumlee, A. E., Marolf, A. J., Randall, E. K., Bachand, A. M., & Quimby, J. M. (2016) · Veterinary Radiology & Ultrasound · doi:10.1111/vru.12435 · Cited by 2
Validation of a Non-Transmitting Memory Belt for Measuring Heart Rate Variability
Sammito, S., & Böckelmann, I. (2015) · Cited by 3
Forte, L. D. M., Manchado-Gobatto, F. D. B., Rodrigues, R. C. M., Gallani, M. C. B. J., & Gobatto, C. A. (2017) · Journal of sport and health science/Journal of Sport and Health Science · doi:10.1016/j.jshs.2017.02.001 · Cited by 2
Díaz–González, C. D. L. M., la Rosa-Hormiga, M. D., Ramal-López, J. M., González, J. J., & Marrero‐Morales, M. S. (2017) · Journal of Clinical Nursing · doi:10.1111/jocn.14012 · Cited by 2
A Weight Estimation Strategy for Preterm and Full-Term Infants
Abdel‐Rahman, S. M., Paul, I. M., Delmore, P., James, L. P., Fearn, L., Atz, A. M., Poindexter, B. B., Al-Uzri, A. Y., Lewandowski, A., Harper, B., et al. (2017) · Global Pediatric Health · doi:10.1177/2333794x17748775 · Cited by 2
The statistical properties of raw and preprocessed ToF mass spectra
Thacker, N. A., Tar, P., Seepujak, A., & Gilmour, J. D. (2018) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2018.03.005 · Cited by 2
Chiu, C., Pease, D. L., Fawkner, S. G., Dunn, M., & Sanders, R. H. (2018) · Computer Methods in Biomechanics and Biomedical Engineering Imaging & Visualization · doi:10.1080/21681163.2018.1492971 · Cited by 2
Gómez-Lombardi, A., Valeria Álvarez, N., Allison López, R., & Rodrigo Neira, M. (2018) · Revista de otorrinolaringología y cirugía de cabeza y cuello · doi:10.4067/s0717-75262018000300267 · Cited by 2
Chen, L., Zhan, Q., Peng, W., Song, T., Liu, Q., & Lu, J. (2018) · BMC Medical Imaging · doi:10.1186/s12880-018-0293-1 · Cited by 2
Examining the Reliability of Scores From a Performance Assessment of Practice-Based Competencies
Roberts, M. R., Alves, C., Werther, K., & Bahry, L. M. (2018) · Journal of Psychoeducational Assessment · doi:10.1177/0734282918816849 · Cited by 2
Comparison of small-volume tubes with vacuum blood tubes for complete blood count
Ünal, K. (2019) · International journal of medical biochemistry/International journal of medical biochemistry : · doi:10.14744/ijmb.2019.69188 · Cited by 2
Repeatability and Agreement of Various High-Speed Macrotexture Measurement Devices
Bongioanni, V. I., Maeger, K., Katicha, S. W., Izeppi, E. D. L., & Flintsch, G. W. (2019) · Transportation Research Record Journal of the Transportation Research Board · doi:10.1177/0361198119830309 · Cited by 2
Burk, K. M., Kück, K., & Orr, J. A. (2019) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-019-00264-5 · Cited by 2
Yamamoto, K., Irino, T., Matsui, T., Araki, S., Kinoshita, K., & Nakatani, T. (2019) · Nippon Onkyo Gakkaishi/Acoustical science and technology/Nihon Onkyo Gakkaishi · doi:10.1250/ast.40.84 · Cited by 2
Takegami, Y., Seki, T., Higuchi, Y., Osawa, Y., & Ishiguro, N. (2019) · Modern Rheumatology · doi:10.1080/14397595.2019.1592799 · Cited by 2
Fujino, K., Ohno, K., Fujiwara, K., Yokota, A., & Neo, M. (2019) · Journal of Medical Ultrasonics · doi:10.1007/s10396-019-00945-3 · Cited by 2
Lamrabat, S., Lyagoubi, A., Bouayadi, O., Elmalki, J., Kouche, K. E., Bensalah, M., & Choukri, M. A. (2019) · Practical Laboratory Medicine · doi:10.1016/j.plabm.2019.e00121 · Cited by 2
Yoon, J., Yoon, S. H., & Hahn, S. (2019) · BMC Medical Research Methodology · doi:10.1186/s12874-019-0727-7 · Cited by 2
Escribano‐Serrano, J., Casto-Jarillo, C., Berruguilla-Pérez, E., González-Borrachero, M. L., Santotoribio, J. D., Cañavate-Solano, C., Calero‐Ruiz, M. M., & Doña, A. M. (2019) · Medicina de Familia SEMERGEN · doi:10.1016/j.semerg.2019.02.012 · Cited by 2
Servant, D., Drumez, É., Raynal, S., Demarty, A.-L., Salembier, A., Deschepper, M. H., Bizet, M. A., Pisanu-Zimny, A., Culem, J. B., Labreuche, J., et al. (2019) · Revue d Épidémiologie et de Santé Publique · doi:10.1016/j.respe.2019.05.011 · Cited by 8
Pleural fluid glucose testing using a finger stick glucometer: a novel bedside test
Abdo, T., Bhardwaj, H., Ishaq, M., Keddissi, J. I., & Youness, H. A. (2019) · Journal of Thoracic Disease · doi:10.21037/jtd.2019.09.04 · Cited by 2
Borissov, R. S., Espeland, S., & Iversen, M. H. (2019) · Fish Physiology and Biochemistry · doi:10.1007/s10695-019-00638-1 · Cited by 2
Janulevičienė, I., & Šiaudvytytė, L. (2019) · Modeling and simulation in science, engineering & technology · doi:10.1007/978-3-030-25886-3_20 · Cited by 2
Gufler, H., Wagner, S., Niefeldt, S., Klopsch, C., Brill, R., Wohlgemuth, W. A., & Yerebakan, C. (2019) · Acta Radiologica · doi:10.1177/0284185119886318 · Cited by 2
Horstmann, H., Medico, P., Lasch, F., Krutsch, W., & Weber-Spickschen, T. S. (2020) · Open Access Journal of Sports Medicine · doi:10.2147/oajsm.s214598 · Cited by 2
Moissenet, F., Naaïm, A., Ornetti, P., Bourredjem, A., Binquet, C., Morisset, C., Gouteron, A., Maillefert, J.-F., & Laroche, D. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2019.00457 · Cited by 4
Validity of Fitbit Flex® consumer device on the sleep evaluation
López-Flores, M., Fernandez, A. R., Villa-Vicente, J., Iglesias, D. S., & Marroyo, J. A. R. (2020) · Cultura Ciencia y Deporte · doi:10.12800/ccd.v15i43.1397 · Cited by 2
Sugizaki, C. S. D. A., Braga, C. C., Freitas, A. T. V. D. S., & Peixoto, M. D. R. G. (2020) · Brazilian Journal of Nephrology · doi:10.1590/2175-8239-jbn-2019-0151 · Cited by 2
A field tool for the aerobic power evaluation of middle-aged female recreational runners
Bonet, J. B., Magalhães, J., Viscor, G., Pagés, T., Javierre, C. F., & Torrella, J. R. (2020) · Women & Health · doi:10.1080/03630242.2020.1746953 · Cited by 2
Francescato, M., Canciani, M., & Cettolo, V. (2020) · European Journal of Applied Physiology · doi:10.1007/s00421-020-04374-w · Cited by 1
Buldt, A. K., Munteanu, S. E., Allan, J. J., Tan, J. M., Auhl, M., Landorf, K. B., Roddy, E., & Menz, H. B. (2020) · Arthritis Care & Research · doi:10.1002/acr.24227 · Cited by 2
Energy expenditure estimation of a moderate-intensity strength training session
João, G. A., Rodríguez, D., Tavares, L. D., Rica, R. L., Júnior, N. C., Reis, V. M., Pontes, F. L., Baker, J. S., Bocalini, D. S., & Júnior, A. J. F. (2020) · Cogent Medicine · doi:10.1080/2331205x.2020.1794500 · Cited by 3
Rathnayake, N., Alwis, G., Lenora, J., & Lekamwasam, S. (2020) · Journal of Obesity · doi:10.1155/2020/2087346 · Cited by 5
Reliability of 3 Strategies of Orbital Tumor Volume Measurement Using Phantom Modeling
Tooley, A. A., Maher, M. D., Cooper, C., Godfrey, K. J., Tran, A. Q., & Kazim, M. (2020) · Ophthalmic Plastic and Reconstructive Surgery · doi:10.1097/iop.0000000000001785 · Cited by 2
Wang, Y., Liu, L., Lakin, R., Polidovitch, N., Liu, G., Yang, H., Yu, M., Yan, M., Zhao, D., Backx, P. H., et al. (2020) · BMC Cardiovascular Disorders · doi:10.1186/s12872-020-01632-9 · Cited by 2
Fuzzy Set Similarity for Feature Selection in Classification
Cross, V. V., Zmuda, M. A., Paul, R., & Hall, L. (2020) · IEEE International Conference on Fuzzy Systems (FUZZ-IEEE) · doi:10.1109/fuzz48607.2020.9177820 · Cited by 2
Šperling, D., Karembé, H., Zouharová, M., & Nedbalcová, K. (2020) · Veterinární Medicína · doi:10.17221/111/2020-vetmed · Cited by 3
Measuring nested frequency of plants from digital images with SampleFreq
Cox, S. E., Booth, D. T., & Berryman, R. D. (2020) · Ecological Indicators · doi:10.1016/j.ecolind.2020.106946 · Cited by 2
The Failure of Plate Diagrams in Estimating Individualized Offered Portion Size: An enable Study
Ott, A., Voigt, M., Sieber, C. C., & Volkert, D. (2020) · Journal of the American Medical Directors Association · doi:10.1016/j.jamda.2020.11.012 · Cited by 4
Andrade, L. S., Silva, M. R., Schaun, G. Z., Rodrigues, S. N., Gomes, M. B., David, G. B., Pinto, S. S., & Alberton, C. L. (2021) · Revista Brasileira de Fisiologia do Exercício · doi:10.33233/rbfex.v19i6.4202 · Cited by 3
Validity and reliability of the Child Perceptions Questionnaire 11–14 for Colombian school children
García, A., Pineda, J. L., Chaparro, D., Duque, J. A. R., & Rodríguez, M. J. (2021) · European Archives of Paediatric Dentistry · doi:10.1007/s40368-020-00587-x · Cited by 4
Franco, C. S., Sexton, C. T., Flores‐Mir, C., & Healey, D. L. (2021) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2020.09.022 · Cited by 3
White, S. J., Butlin, M., Brown, A. M., & White, R. S. (2021) · Australian Journal of Primary Health · doi:10.1071/py20214 · Cited by 2
Putz, F. J., Pfister, K., Bergler, T., Banas, M. C., Jung, E. M., Banas, B., & Schierling, W. (2021) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2021.02.014 · Cited by 2
Fujiwara, Y., Sasaki, T., Muto, Y., Hirano, M., Kamizaki, R., Murakami, K., Miura, N., Fujibuchi, Y., Ohmukai, N., Ueda, N., et al. (2021) · PubMed · doi:10.18926/amo/61897 · Cited by 2
A reliability study of a novel visual ischemic palpation scale in an experimental setting
Margelli, M., Segat, A., Raule, M., Giacchetti, C., Zanoli, G. A., & Pellicciari, L. (2021) · Musculoskeletal Science and Practice · doi:10.1016/j.msksp.2021.102384 · Cited by 2
Comparison of novel DXA system, Shimazu SONIALVISION G4, with GE-Lunar PRODIGY
Takemoto, T., Oguchi, T., & Oda, K. (2021) · Journal of Bone and Mineral Metabolism · doi:10.1007/s00774-021-01241-2 · Cited by 2
Alternative sites of echocardiographic epicardial fat assessment and coronary artery disease
Ferreira, J., Martins, R., Monteiro, S. R., Teixeira, R. P., & Gonçalves, L. M. M. (2021) · Journal of Ultrasound · doi:10.1007/s40477-021-00598-4 · Cited by 4
Mehrabani, G., Gross, D. P., Aminian, S., & Manns, P. J. (2021) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2020-0066 · Cited by 2
van Weely, S. F. E. (2021) · The Journal of Rheumatology · doi:10.3899/jrheum.210822 · Cited by 2
Comparison of 3‐D mandibular surfaces generated by MRI and CT
Maeda, J., Tanikawa, C., Nagata, N., Lim, J., Kreiborg, S., Murakami, S., & Yamashiro, T. (2021) · Orthodontics and Craniofacial Research · doi:10.1111/ocr.12540 · Cited by 2
Comparison of noncontact camera-based methods for measuring pulse-rate of awake infants
Ogawa‐Ochiai, K., Kiyokawa, T., Kiyomitsu, K., Bednarik, R., Mitani, Y., & Tsumura, N. (2021) · Artificial Life and Robotics · doi:10.1007/s10015-021-00701-2 · Cited by 2
Smyth, B. J., Polaski, R. S., Safer, A., Boettcher, F. A., Konrad‐Martin, D., & Gratton, M. A. (2021) · Journal of the American Association for Laboratory Animal Science · doi:10.30802/aalas-jaalas-21-000011 · Cited by 4
Can, M. F., Güven, B., & Tekin, A. (2021) · Indian Journal of Medical Biochemistry · doi:10.5005/jp-journals-10054-0174 · Cited by 2
Xu, Y., Duan, R., Feng, P., Gao, W., Dong, X., & Cheng, G. (2021) · Frontiers in Nutrition · doi:10.3389/fnut.2021.755683 · Cited by 3
The reliability of VO2 kinetics during a 6-minute walking test is influenced by walk speed
Fujita, D., & Kubo, Y. (2021) · Journal of Physical Therapy Science · doi:10.1589/jpts.33.876 · Cited by 2
Onset and Offset Detection of Respiratory EMG Data Based on Energy Operator Signal
Spasojevic, S., Rodrigues, A., Mahdaviani, K., Reid, W. D., Mihailidis, A., & Khan, S. S. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9631101 · Cited by 2
Peller, J. A., McGinnis, C. L., Thompson, K. J., Siddiqui, I., Martinie, J. B., Iannitti, D. A., & Trammell, S. R. (2021) · Open Journal of Medical Imaging · doi:10.4236/ojmi.2021.114011 · Cited by 2
Raschka, C. J., Kwon, O.-S., & Koch, H. J. (2021) · Papers on Anthropology · doi:10.12697/poa.2021.30.2.07 · Cited by 2
Pre-Burn Health-Related Quality of Life: Patient and Partner Perspectives
Dam, E. B.-V., Hofland, H. W. C., de Jong, A. E. E., & Loey, N. E. E. V. (2022) · European Burn Journal · doi:10.3390/ebj3010011 · Cited by 2
Desprez, I., Pelchat, J., Beaufrère, H., Beazley, S. G., & Duke‐Novakovski, T. (2022) · Veterinary Anaesthesia and Analgesia · doi:10.1016/j.vaa.2022.03.004 · Cited by 2
Wu, L., Ye, Z., Zhang, X., Zheng, A., Zhang, X., Chen, L., Ouyang, D., Zheng, L., & Liu, X. (2022) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2022.114756 · Cited by 2
Mathematical Arterialization of Capillary Blood for Blood Gas Analysis in Critically Ill Patients
Daher, A., Veelken, J., & Müller, T. (2022) · Respiration · doi:10.1159/000524491 · Cited by 2
Pinto, A. D. A., Bim, M. A., Moreno, Y. M. F., de Lima, L. R. A., Silva, A. M., & Pelegrini, A. (2022) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2021.2007211 · Cited by 2
Keiller, A. C., Holmén, A., Hansson, C., Ricksten, S., Bragadottir, G., & Bagge, R. O. (2022) · Perfusion · doi:10.1177/02676591221093201 · Cited by 2
Chen, C., Cheng, L.-Y., Hsu, S.-W., Liao, M., Ku, P., & Liu, Y. (2022) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2022.898086 · Cited by 3
Kirkland, D., Whitwell, J., Smith, R., Hashimoto, K., Ji, Z., Kenny, J. D., Koyama, N., Lovell, D. P., Martus, H., Meurer, K., et al. (2022) · Mutation Research/Genetic Toxicology and Environmental Mutagenesis · doi:10.1016/j.mrgentox.2022.503503 · Cited by 5
McMahon, N. F., Brooker, P. G., Kadach, S., Pavey, T., & LEVERITT, M. D. (2022) · Journal of Human Nutrition and Dietetics · doi:10.1111/jhn.13048 · Cited by 4
Aggarwal, M., Garg, N. M., Agrawal, A., & Sardana, V. (2022) · The Indian Journal of Pediatrics · doi:10.1007/s12098-022-04176-2 · Cited by 2
Alves, M. M., Dressel, H., & Radtke, T. (2022) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2022.103940 · Cited by 3
[Variability of hemoglobin and hematocrit determined in blood gas equipment].
Santos-Martínez, L. E., Cortés-Ruiz, J. R., Vázquez-Tecpanecatl, O., Ordoñez-Reyna, A., & Quevedo-Paredes, J. (2022) · PubMed Central · Cited by 2
Wingood, M., Jones, S. M. W., Gell, N., Brach, J. S., & Peters, D. M. (2022) · Journal of Physical Activity and Health · doi:10.1123/jpah.2021-0821 · Cited by 2
Pineau, J. (2022) · Gazzetta Medica Italiana Archivio per le Scienze Mediche · doi:10.23736/s0393-3660.20.04422-8 · Cited by 2
VEP visual acuity in children with cortical visual impairment
Mackay, A. M. (2022) · International Journal of Clinical and Experimental Ophthalmology · doi:10.29328/journal.ijceo.1001047 · Cited by 3
Mwau, M., Schaffer, S., Kimani, H., Kasiano, P., Ogolla, F., Ajema, E., ADOYO-, S. K. M. L. T.-H. M., Nyairo, E. K., Saleri, N., & Nair, S. V. (2022) · PLoS ONE · doi:10.1371/journal.pone.0269838 · Cited by 2
Damaraju, V., Nath, A., Sehgal, I. S., Muthu, V., Prasad, K. T., Dhooria, S., Aggarwal, A. N., & Agarwal, R. (2022) · Lung India · doi:10.4103/lungindia.lungindia_223_22 · Cited by 2
Khimani, K. S., Ordonez, A., & Pandit, R. T. (2022) · Journal of Cataract & Refractive Surgery · doi:10.1097/j.jcrs.0000000000001045 · Cited by 2
Predicting energy intake in adults who are dieting and exercising
Gerving, C., Lasater, R., Starling, J. K., Ostendorf, D. M., Redman, L. M., Estabrooks, C., Cummiskey, K., Antonetti, V. W., & Thomas, D. M. (2022) · International Journal of Obesity · doi:10.1038/s41366-022-01205-0 · Cited by 2
Hisano, F., Watanabe, S., Niwa, S., Nakanishi, K., Mawaki, A., Takeno, Y., Murota, K., Honda, I., Fujimoto, E., & Oshima, C. (2022) · Lymphatic Research and Biology · doi:10.1089/lrb.2022.0021 · Cited by 2
Hill, B. G., Holloway, R., Lim, J. T. S., Clifford, K. A., Lesche, S., Letts, J., & Krysa, J. (2022) · Australasian Journal of Ultrasound in Medicine · doi:10.1002/ajum.12319 · Cited by 2
Artificial neural networks for non-linear age correction of diffusion metrics in the brain
Kocar, T. D., Behler, A., Leinert, C., Denkinger, M. D., Ludolph, A. C., Müller, H., & Kassubek, J. (2022) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2022.999787 · Cited by 2
Midorikawa, T., Ohta, M., Hikihara, Y., Torii, S., & Sakamoto, S. (2022) · British Journal Of Nutrition · doi:10.1017/s0007114522003269 · Cited by 3
Langendoen‐Gort, M., Rutters, F., Huijts, D., Elders, P. J. M., Terwee, C. B., & Hugtenburg, J. G. (2022) · Clinical Pharmacology in Drug Development · doi:10.1002/cpdd.1185 · Cited by 3
Busk, H., Marianne, N., Rønne, P. J., Glavin, K. M., Kjær, T. W., Skou, S. T., & Wienecke, T. (2022) · Neuroscience Insights · doi:10.1177/26331055221145002 · Cited by 2
Perceived and calculated diet quality improvements in a randomized mHealth weight loss trial
Cheng, J. S.-C., Costacou, T., Rockette‐Wagner, B., Sereika, S. M., Conroy, M. B., Kriska, A. M., Kariuki, J. K., Klem, M. L., Parmanto, B., & Burke, L. E. (2023) · Behavioral Medicine · doi:10.1080/08964289.2023.2178374 · Cited by 4
Hoffmann, J., Amici, C., Minelli, C., & Borboni, A. (2023) · International Journal of Performance Analysis in Sport · doi:10.1080/24748668.2023.2181563 · Cited by 2
Siafis, S., & Leucht, S. (2023) · European Neuropsychopharmacology · doi:10.1016/j.euroneuro.2023.02.012 · Cited by 2
Díaz–González, C. D. L. M., Mateos-López, N., la Rosa-Hormiga, M. D., & Carballo-Hernández, G. (2023) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph20054665 · Cited by 3
Bim, M. A., Pinto, A. D. A., Gonzaga, I., Marco, J. C. P. D., de Angelo, H. C. C., Claumann, G. S., & Pelegrini, A. (2022) · journal of physical education · doi:10.4025/jphyseduc.v34i1.3403 · Cited by 3
Comparison of Algorithms to Compute Relaxation Time Maps in Magnetic Resonance Imaging
Rodriguez, I., Izquierdo-García, J. L., Yazdanparast, E., Castejón, D., & Ruíz-Cabello, J. (2023) · Applied Sciences · doi:10.3390/app13074083 · Cited by 2
Uzawa, H., Ishii, H. H., Ishida, T., Shida, T., Furuyama, H., & Nishida, Y. (2023) · Journal of Pain Research · doi:10.2147/jpr.s391943 · Cited by 2
Video-driven simulation of lower limb mechanical loading during aquatic exercises
Lauer, J. (2023) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2023.111576 · Cited by 2
Lawrence, E. M., Kieler, M., Cooley, G., Wells, S. A., & Cho, S. Y. (2023) · PLoS ONE · doi:10.1371/journal.pone.0283830 · Cited by 2
Effect of scan duration on CT perfusion values in metastases from renal cell carcinoma
Ng, C. S., Chandler, A. G., Chen, Y., Wei, W., Tannir, N. M., & Hobbs, B. P. (2023) · Research in Diagnostic and Interventional Imaging · doi:10.1016/j.redii.2023.100028 · Cited by 2
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.